Loading...
HomeMy WebLinkAboutcompaction test Creekside lot 38o���NTr� • cForFti e zA Universal w m 02ci_ _ G 9`S TESTING'\N=ems ornpany • UES Project No: 3360.1800067.0000 Workorder No: 224751-1 Report Date: 06/21/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In -Place Density Test Report Client: D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician: Mark Rogers 1430 Culver Drive, NE Date Tested: 02/10/2021 Palm Bay, FL 32907 Project: 18-5043.03 CREEKSIDE Yorktown Drive & Okeechobee Road, Fort Pierce, County, FL Type of Test: Area Tested: Lot 38: 3342 Trinity Circle Permit # 2011- Field: ASTM D-6938 Nuclear Gauge Method 0179 Material: Backfill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Top of Pipe The tests below meet the 95% minimum compaction requirement. Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail 1 Northeast corner of lot 0-1 ft 118.6 10.8 116.1 10.4 98 Pass 2 Southwest corner of lot 0-1 ft 118.6 10.8 115.8 10.3 98 Pass 3 Center of lot 0-1 ft 118.6 10.8 114.E 10.4 97 Pass Remarks: Above stripped surface 1-2, 2-3' HCP=60+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil. Permit # 2011-0179 Reviewed By GFA International, Inc FBPE Registry No.4930 OMINIC ;. �PS.......... o: _ * N. 84146 - .k _ '' S`��ONA1- fit,,• Digitally signed by Thomas D Monta no:A01410000000 17818498DCD000019A3 Date: 2021.06.21 12:10:32-04'00' Thomas Dominic Montano Branch Manager STATE OF FLORIDA Professional Engineer No. 84146 This item has been digitally signed and sealed by Thomas Dominic Montano on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. The in -place density tests were performed within the foundation/building pad footprint of the referenced residential lot. The test results either meet or exceed the requirements of the FHA/HUD manual and the current edition of the Florida Building Code for soil compaction. The Contractor is responsible for maintaining the tested soil subgrade in the same condition that existed at the time GFA performed the referenced density tests. GFA is not responsible if the tested area is altered from the approved condition at the time of testing. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1