HomeMy WebLinkAboutAPPROVED Well & Septic HD Permit - 7704 pacific aveSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
CONSTRUCTION PERMIT FOR:
APPLICANT: (434 21st Street
OSTDS New
PROPERTY ADDRESS: 7704 Pacific Ave Fort Pierce, FL 34951
LOT: 12 BLOCK: 44 SUBDIVISION: Lakewood Park
PROPERTY ID #: 1301-605-0109-000-8
PERMIT #:56-SF-2240283
APPLICATION # : AP 1629786
DATE PAID:
FEE PAID:
RECEIPT #:
DOCUMENT #: PR1523804
[SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ 900 ] GALLONS / GPD Seotic new CAPACITY
A [ ] GALLONS / GPD N/A CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ]
D [ 500 ] SQUARE FEET Drainfield new SYSTEM
R [ ] SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [X] MOUND
I CONFIGURATION: [ ] TRENCH [X] BED [ ]
N
F LOCATION OF BENCHMARK: Site BM, NiD CL of Rd, center of property
I ELEVATION OF PROPOSED SYSTEM SITE
E BOTTOM OF DRAINFIELD TO BE
L
DE
O
T
H
E
R
[ 3.00 ] [ INCHES FT ] [ ABOVE BELOW BENCHMARK/REFERENCE POINT
[ 4.00 ] [ INCHES FT I( ABOVE BELOW ]BENCHMARK/REFERENCE POINT
ILL REQUIRED: rZS.UU] INCHES EXCAVATION REQUIRED: [ ] INCHES
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of
300 gpd.
SPECIFICATIONS BY: Brian J I ram TITLE:
Environmental Specialist III
APPROVED BY: TITLE: Environmental Specialist III St. Lucie
Brian J ngram
DATE ISSUED: 03/29/2021 EXPIRATION DATE:
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
09/29/2022
CHD
Page 1 of 3
v 1.1.4
AP1629786
SE1488598
NOTICE OF RIGHTS
A party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such
proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department, within twenty-one (21) days from the receipt of this order. The address of the
Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency
Clerk's facsimile number is 850-413-8743.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order will
constitute a waiver of your right to an administrative hearing, and this order shall become a 'final
order'.
Should this order become a final order, a party who is adversely affected by it is entitled
to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are
governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced
by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a
second copy, accompanied by the filing fees required by law, with the Court of Appeal in the
appropriate District Court. The notice must be filed within 30 days of rendition of the final order.
lir
STATE OF FLORIDA PERMIT APPLICATION TO CONSTRUCT, JD �_— �`� U�(� �
_ .._.. REPAIR, 11,10DIFY, OR ABANDON A WELL F'urrit 59-31524
,(k, _
:151�!t'1WC:i! _,L'c•'i$�iILL : t,' Florida Un::we ru— '. _... .. _.._ _... ..-........__._.,..
,:' LiCABLE FIELDS — - -
: Nprthtvr5t t'Denot(as ,',-.,.;;r,. c i i �i" V•lhera :' ,� �;i,;;,hl,, �rrrn - __ ...._._._�.......
ll 9:I uL I:Wn:- r�(?Ua11Pd i84:1, 'llcY,wai
�St .four:•, I A.
S! %'v3It !e lbvft r - .. - '•" rim 5:� U(.(i0 Y{p, L'.1Ciitrrr.;tq;r'd:,
'. tXtill;Np! F it ('rim ratin''7
r 'fifl(f'F.S •' �J .. _ ':;•:
. f '+ (� ( t: ?ram c NumGr..
1r!; ot t...t.
L' ( ! !t ?LrnR:nlCt:• ^;wr t , Y! U;a, `._. .. !J_
` t bcf.)'n;.lur� � _} } {check d G2•�2=rt� 't'es
I 1 t Y lM1`rr �J 4 t (�rc..l`• 1 +\_i �ti ? ��4. t t� {..,\ - t._.7 �t . `, ( t� L� � �..�., t=fir':.i� f. - �•-�C ` �7 �±���. � .� L� : ..
_ o
JL
-
` Crty
is <,U7rtj :oral:'JX q, 1-....._ ... ----..
7_!P
r f
f i.Ar;dsCupe I;ngaiiCtn _•__tir�rtctattttal krir�;,lior, _ _ Sitr. Wontip
Invr:•sG�talion u�
�,x+n y RaC er,fianlarrr. (rncic:Gvr. Lroe3trark
t• u;,sc;ry Irr;gatiwi Tpst
t 1r ltr ti(7n C:crrrmur.,{yl[:)4=='t C')rntnrrcr:rU! ttG, Earm-Coup.ed t. w4f1P.r(wil MAR 2 9 202
i --_Gall Course Irrluatto.; I IL%AC Supply
' ..... ,... ._.. .._ rHVAC Return
Ls<tI S!
j f.,f .J.J. .I
:+� 1.1 •�
`" r "�'' ��( '• � DOH in St Lucie Coo:
LVIRWNMENTAL HEP
t.
i..t%`n '( art:,
�.
Yf. ,•}:.nl': .raft'
c. a n ) Pttmaty i,di inc, G,Jr,,s cl � r r-lulo. flair, To
S
t
:; tr P _....
r •,•,uri.tt F�rd� r:;t ttrjftat-t by Al�j,tu.r�,t s, r , 1
Rolivy
;., :,tar(tC r f' n•,-,ry. S%�orxirn'y. an ; .. -': ,, ... _.. _ .___ _.. .
To _ 6,� i dra!r•'tit@ ,,a rats s
er
.`•' "V.aft r'fv^j, . 1 r tf
)ar
SEi1CJ,`tt,: Cement- Other_ ... .
Be:u<;rnte v:_;aI Camera - OtPer, . -. .
SI' Ltst r)urr,Ut:r ,:I •r; r e+ c.x):. •n.f uru> t 'netla .irt site , Ff
on t}tfr Op h f'<i �Urt t;r�uQU3 Orclp At?y cUvQ.req (1rt(f$rr1 co iln imptive1water Use Pemtli (CVr1,v1: If, 1
Yt, fl yes no , titN fC!Iglaii:q GUP/NUP Vt) District Weil If) No.
_._.......... _..
a;tEr) c"five VUGS
$d
i 1 I t r: ':C. Ji l,rI,r. r r r t'•n: t...r . t )jJ PQ
. c�.!.,;77?�<�a�'�XY.ra'd(�:.".'r!14..B'^!.c'z�,a'.,.:n'-"k;.••!�1+••„'2+.,ytaa��twasxr,.orn�..s=r.... �, :.» �.� � _- _ -_- - _ 'U:IIC
"` ' �F(',:ii )iE F ;ESkt•t7r\T"; Q7 !- i HE kh.'AD or\ r)ht ELATED AU T H*014, i+
u...o......,.- r� .':, %•ll_;. - E t. I ur l r',(, .:(.'..,_; ,,�•.. tit.:�•; HE:PAtR �.i;J;,):Y(CAr'�U�J, GKABAr,GG!•1htEN1 ACTNITIES
0
TH
St. Lucie County Health Department
5150 NW Milner Dr Port Saint Lucie FL 34983
PAYING ON: #.56-SF-2240283 BILL DOC #:56-BID-5180804 CONSTRUCTION APPLICATION #: AP1629786
RECEIVED FROM: Pedro Quiiada AMOUNT PAID: $ 660.00
PAYMENT FORM: CREDIT CARD 05845J PAYMENT DATE: 02/11/2021
MA I L TO: (434 21 st Street LLC)
FACILITY NAME:
PROPERTY LOCATION:
7704 Pacific Ave
Fort Pierce, FL 34951
12 44
Lot: Block:
Property ID: 1301-605-0109-000-8
EXPLANATION or DESCRIPTION:
QUANTITY
FEE
128 - OSTDS Construction System Inspection Research Fee
1
$
5.00
-1 - Surcharge (All)
1
$
45.00
-1 - OSTDS New Permit Surcharge
1
$
100.00
-1 - OSTDS Construction Application and Plan Review,New
1
$
100.00
123 - OSTDS Construction Site Evaluation
1
$
115.00
126 - OSTDS Construction Permit (New or Mod, Amendment)
1
$
55.00
127 - OSTDS Construction System Inspection
1
$
75.00
133 - OSTDS Construction Reinspection
1
$
50.00
-1 - Well Construction
1
$
115.00
RECEIVED BY: WhighamJL AUDIT CONTROL NO. 56-PID-4884245
Note: 59-31524
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
PERMIT NO. �3'
DATE PAID:
FEE PAID: ( A(p . cro
RECEIPT #:
[V/] New System [ ] Existing System [ ] Holding Tank [ ] Innovative
[ ] Repair [ ] Abandonment [ ] Temporary [ I
APPLICANT: 434 21ST STREET LLC
AGENT: Pedro Quijada TELEPHONE: 954-850-0618
MAILING ADDRESS: 9111 E Bay Harbor Dr 6f, Miami FL 33154
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST HE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (NM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
PROPERTY INFORMATION
LOT: 12 BLOCK: 44 SUBDIVISION: LAKEWOOD PARK -UNIT 5 PLATTED:
PROPERTY ID # : 1301-605-0109-000-8 ZONING: RS4 I/M OR EQUIVALENT: !, ] a
PROPERTY SIZE: 027 ACRES WATER SUPPLY: [,(] PRIVATE PUBLIC [ ]<-2000GPD [ ]>2000GPD
IS SEWER AVAILASI.E AS PER 381.0065, FS? [ }�e��D DISTANCE TO SEWER: FT
PROPERTY ADDRESS: 7704 PACIFIC AVE, Fort Pierce FL 34951
DIRECTIONS TO PROPERTY: See attached lot location.
BUILDING INFORMATION [,/] RESIDENTIAL [ ] COMMERCIAL
Unit Type of No. of Building Commercial/Institutional System Design
No Establishment Bedrocros Area Safi Table 1, Chapter 64E-6, PAC
1 Single -Family 3 2264 N/A
2 /��Y IR
3
4
[ ] Floor/Equipment Drains [ J Other (Specify)
SIGNATURE: t DATE:
DH 4015, 08/09 (Obsoletes previous editions which may not be used)
Incorporated 64E-6.001, FAC Page 1 of 4
AUTHORIZED SEWAGE FLOW:
UNOBSTRUCTED AREA AVAILABLE
BENCHMARK/REFERENCE POINT LOCATION
ELEVATION OF PROPOSED SYSTEM SITE
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATION
APPLICANT: 434 21 st Street LLC
CONTRACTOR / AGENT: Pedro Quijada
LOT: 12 BLOCK: 44
APPLICATION # AP1629786
PERMIT # 56-SF-2240283
DOCUMENT # SF-1488598
SUBDIVISION: Lakewood Park ID#: 1301-605-0109-000-8
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE
REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN:
TOTAL ESTIMATED SEWAGE FLOW: 300
404.99
750.00
[X]YES [ ]NO NET USABLE AREA AVAILABLE: 0.27 ACRES
GALLONS PER DAY [ RESIDENCES -TABLET/ OTHER -TABLE 2 ]
GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ]
SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT
Site BM, NiD CL of Rd, center of property
3.00 [ INCHES / FT ] [ ABOVE /
] BENCHMARK/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED
SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: FT
DITCHES/SWALES: 15
FT NORMALLY WET: [ ]YES
[X]NO
WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 75 FT NON -POTABLE:
87 FT
BUILDING FOUNDATIONS: 5 FT
PROPERTY LINES:
5 FT POTABLE WATER LINES:
55 FT
SITE SUBJECT TO FREQUENT FLOODING?
[ ]YES [X]NO
10 YEAR FLOODING? [ ]YES
[X]NO]
10 YEAR FLOOD ELEVATION FOR SITE:
FT[ MSL / NGVD ]
SITE ELEVATION: FT [ MSL / NGVD
SOIL PROFILE TNFORMATTON STTE 1
SOTL
PROFTLF. TNFORMATTON STTF. 2
USDA SOIL SERIES:
Munsell #/Color
Texture
Depth
10YR 4/1
Sand
0 To 10
10YR 5/1
Sand
10 To 24
10YR 6/1
Sand
20 To 25
10YR 411
Loamy Sand
25 To 28
10YR 4/1
Sand
28 To 39
10YR 5/1
Sand
39 To 57
10YR 5/3
Sand
57 To 65
HOLE CAVING
Refusal
65 To 72
USDA SOIL SERIES:
Munsell #/Color
Texture
Depth
10YR 4/1
Sand
0 To 15
10YR 5/1
Sand
15 To 32
10YR 6/1
Sand
17 To 33
1OYR 4/2
Loamy Sand
33 To 37
10YR 5/2
Sand
37 To 52
10YR 5/3
Sand
52 To 63
HOLE CAVING
Refusal
63 To 72
OBSERVED WATER TABLE: 40.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ]
ESTIMATED WET SEASON WATER TABLE ELEVATION: 17 INCHES [ ABOVE / BELOW ] EXISTING GRADE
HIGH WATER TABLE VEGETATION: [ ]YES [X]NO MOTTLING: [X]YES [ ]NO DEPTH: 17 nn INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Loamy Sand/0.60 DEPTH OF EXCAVATION:
DRAINFIELD CONFIGURATION: [ ] TRENCH [XI BED [ ] OTHER (SPECIFY)
FREMARKS/ADDITIONAL CRITERIA
WSWT determined using USDA WSS and soil borings.
10YR6/1 stripping in 10YR5/1 matrix >10% with diffuse boundaries starting at 17" in SB2.
SB1 and SB2 3" below BM.
SITE EVALUATED BY:
Ingram, Briaif (Title: Environmental Specialist III) (ENVIRONMENTAL HEALTH)
DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC
INCHES
DATE: 03/08/2021
Page 3 of 4
AP1629786 EID2240283 v 1.0.2
aAiS 30N31d IMOJ
•
ir
LL
Q)