Loading...
HomeMy WebLinkAboutAPPROVED Site Plan HD Approved - 7808 Hamilton Averevisions no. date CALCULATIONS AIR CONDITIONED AREAS PLAN 1694 SF 1694 SF NON CONDITIONED AREAS PORCH 42 SF GARAGE 419 SF LANAI 109 SF 570 SF GROSS AREA GROSS AREA 2264 SF FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for OSTDS & Well Date: Reviewer. WINDOW SCHEDULE MARK TYPE STYLE SIZE P. NOTES H +D. 001 SH26 SINGLE HUNG T-1" 64' 32.01 34.85 EGRESS 002 PICTURE PICTURE 3'-0" 4'-0" 32.64 35.48 003 PICTURE PICTURE 3'-0" 4'-0" 32.64 35.48 OPAQUE/TEMP. 004 PICTURE PICTURE 3'-0" 2'-0" 33.52 36.36 TEMPERED 005 SH25 SINGLE HUNG 3'-l" 5'-3" 32.01 34.85 EGRESS 006 SH25 SINGLE HUNG 3'-1" 5'-3" 32.01 34.85 EGRESS 007 SH25 SINGLE HUNG T-1" 5'-3" 32.01 1 34.85 008 SH25 SINGLE HUNG 3'-1" 5'-3" 32.01 34.85 009 SH25 SINGLE HUNG 3'-1" 5'-3" 32.01 34.85 010 SH25 SINGLE HUNG T-l" 5'-3" 32.01 34.85 011 SH25 SINGLE HUNG 3'-1" 5-3" 32.01 34.85 1 EGRESS DOOR SCHEDULE MARK STYLE DOOR D.P. NOTES WD HGT + - 001 SINGLE EXTERIOR 3'-0" 8'-0" 31.53 34.35 NOTE #5 002 SINGLE 2'-8" 8'-0" 003 SLIDING DOUBLE 5'-0" 8'-0" 004 SINGLE 2'-8" 8'-0" 005 SINGLE 2'-8" 1'-0" 006 SINGLE 2'-8" 8'-0" 007 SINGLE 2'-8" 8'-0" 006 SINGLE 2'-6" 8'-0" 009 SINGLE 2'-6" 8'-0" 010 BIFOLD 1'-6" 8'-0" 011 SLIDING DOUBLE EXTERIOR 6'-0" 8'-0" 30.02 32.86 012 SINGLE 2'-0" 8'-0" 013 SINGLE 2'-6" 8'-0" 014 SINGLE 2'-8" 8'-0" 015 BIFOLD 2'-4" 1'-0" 016 SINGLE 2'4" 8'-0" LOUVERED 017 SINGLE 2'-8" 8'-0" NOTE #2 018 OVERHEAD 16'-0" 7'-0" 28.20 34.24 NOTES I. ALL MINDOH , DOOR 64A2IN5 TO BE IOYFE: NON IMPAOT - (WAGT OP IONAL) 2. 6ARA6E EMR1' DOOR SFWl BE 50L10 YOOD DOOR NOT Less MAT I-51W IN TNWIESS, SOILID OR VIOIEYOOHBCC><tE 57F DOOR NOT L.E55 THAN I-5/5' MILK OR 20 MIN FIRE FATED DOOR, EOUIPPtD HIM SHF- OLOSIN6 DEVIOE. PER 1`5G-R!023.1 5. VERIFY ALL OPENING MM TO MARrAONRINS ""'OH , DOORS. 4. ALL E RIOR HALL 01 E 1N65 IN EVILDIN55 (ODORS, DOORS' MILL BE FU1Y PROT = MIM IMPACT RESISTANT OOIERIN55-SWITER5. 5. K.FESS DOOR YAM ALRIIN.H TRE"W. DE516MA FF17t6ENOT k£AI6 OF ESCAPE PER FB.O 20n. -d- 0P 1.aDulgn Preavurs Produn R,l.d D,al n a, , (W ... Model N..w, Pmtlucr -I Number -TaI cla„ T Marhad olNbchmeni Wind.w. 55.0 65.0 CGI SH41DDA FL2335e.2 Lami Flange Frame Mullion 90.0 90.0 CGI Series Clipped 1M129.08 FNed Cu- 55.0 65.0 CGI PW4120A FL26095.2 Lami Flange Frame Block cane, skyllAhi, .a- Giaaa boon 55.0 fi5.0 CGI SGD4110A 1121111.2 Lami Flange Frame s- T IMen 50.0 50.0 Therma-To. Smooth Star FL20468.6 Lami French Deen Gore a Oaon Hurricane Prol.cilon Root Vonou.non N)A NIA 0Magi, Clanked Veni 19-0109.02 Reoana M.-I.1 N/A N/A GAF Asphalt Shin FL10124-R27 Fasteners Revised 07/22/2014 I have re. ic,red the above con, ponenIs or cladding and 1 h- at,p,,-d (heir use to this structure. Thee products urevlde adeilnot e resistance to the n roll loads and fore-pecified by current code provisions. D'g ay y dby xois O k I D l ,,,.Ine, Scott Disher Signatare: {ylY DN 5 ifllake,l i D a 6H Architect AR 11586 s/nrzo e 1- d hi ar,i d,n, Des!,,. Praf: Ccn No. Date: u5 Da :2020.099.tb 1I3I:43 designed sw project mgr. vNv checked 5817 date PERHIT_122120 scale v4' • ro moNA job no. 20DIPSF-21't Scott Blakeslee Disher W U Z W 0 U) W J_ C CJ C J a 11 LU W _J U) Z N U) project ARCHITECTURAL Architecture Planning 300 A,-, of Champions Sal, 269 Pdm 8tuh Gaff, florid, 33418 Phony 561.202.6990 F. 56Ln6.2494 nahladi ft- drawing FLOOR PLAN sheet A-1 c 0 U) Q m N 0 0 0 w 2 TREE SCHEDULE PNT TREE DIA. 21010 CAB PALM 21036 OAK 21" 21037 OAK 31" LJ 0 0 0 0 W a O O O SEPTIC SEPTIC LOT 15 LOT 14 (OCCUPIED) (OCCUPIED) FFE: 22.06' FFE: 23.07' (BEARING BASIS) - — S & °51 .%'1-(C�- — FND 1/2" IR I FND 4"x4"? (NO ID)� �� ey— (NO ID) PROPOSED SEPTIC 500 SQ FT / DRAINFIELD � 750 SQ FT./ UNOBSTRUCTED AREA /I 3U LOT 8 (OCCUPIED) / ... FFE:21.89' O / O 0 SEPTIC w O O FND 3/4" (NO A) 3. x x o ui n • �" BENCHMARK A I� SET MAG NAIL AND WASHER 0 N:1166678.82" aI E:849178.34" C)x EL: 20.07' C'3 7 a N89"51'56"W 651.00' �-+ o o UTILITIES: ALL WELLS AND SEPTICS ON ADJACENT PROPERTIES NOT SHOWN WERE EITHER BEYOND 75' OR COULD NOT BE LOCATED. 1 OHW O rn I 1C � B L iC C K 4 I \ I ,-LANAI 1 29.72'_ J 1 LOT 9 (VA *T) M r 30.11' 10 L�9,, 4 o 0 67' � 21.33' PROPOSED RESIDENCE FFE:* 0 ,O N89.51'56"W(C > 75.00'(P);(C) p 0 lb� 0 o ti Ja OJ ncj * FINISHED FLOOR ELEVATION TO BE DETERMINED BY SAINT LUCIE COUNTY HEALTH DEPARTMENT w LOT 13 (OCCUPIED) a FFE:21.59' 0 0 CATV LJ 0 7 10. 28' a o O O O ` \ LOT 10 \ (OCCUPIED) 'F�E: 21.08' U x�1 \ o ' O \ I O V -L SET 5/8" IRC (LB8098) FND 1 /2" IR x (NO ID) �0 1.05' S 0 0.38' W Ln n FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for OSTDs .SFZ2-967-95 & Well #53-31SZ6 P1-4-- flIA on.-2 ) — C,c�(70J00'' R GHT-OF-WAY) _ ^ 'HAMILT N VE. BENCHMARK SET MAG NAIL WASHER N:1166678.94' E: 849287.57' EL: 20.08' ( IN FEET ) 1 inch = 30 ft. SYMBOL 8, APPREV►ATION LEGEND: E EAST/EASTING SITE ST. LUCIE COUNTY, FLORIDA VICINITY MAP NO SCALE RIGHT OF W BENCHMARK (BM) (D MONITORING WELL QQ - AY YYYY EL./ELEV ELEVATION CONTROL NORTH AMERICAN SIGN CATV ❑ CABLE RISER (M) FIELD MEASURED NAVD88 VERTICAL DATUM TOPOGRAPHIC (C) CALCULATED F.F.E. FINISHED FLOOR OF 1988 OFFICIAL RECORDS X 0.0 DATA (SOFT CL CENTERLINE ELEVATION O.R.B. BOOK SURFACE) CLF CHAIN LINK FENCE FND FOUND OHW OVER HEAD WIRES TOPOGRAPHIC CONC CONCRETE SQ FT. SQUARE FEET PG PAGE X 0.00 DATA (HARD ACE) CM CONCRETE INV INVERT P.B. PLAT BOOK W WEST MONUMENT IP IRON PIPE (P) PLAT DATA CPP ®CONCRETE POWER POLE IR IRON ROD P.U* & PUBLIC UTILITY WF WOOD FENCE (CPP) IR/C IRON ROD AND D.E.EASEMENT AND DRAINAGE ca.) WOOD POWER POLE CMP CORRUGATED CAP METAL PIPE PK/D PARKER-KALON R RADIUS P.U. & PUBLIC UTILITY (D) DEED NAIL & DISK REINFORCED D.E. AND DRAINAGE EASEMENT 0 DIAMETER (DIA.) MAG/D MAG NAIL MAG R CP CONCRETE PIPE BRAND NAIL R/W RIGHT-OF-WAY DRAINAGE nM O MANHOLE MAILBOX 0 PROPERTY CORNER DIP DUCTILE IRON PIPE LEGAL DESCRIPTION LOT 9, BLOCK 47, LAKEWOOD PARK UNIT NO. 5, ACCORDING TO THE MAP OR PLAT THEREOF AS RECORDED IN PLAT BOOK 11, PAGE 5, PUBLIC RECORDS LUCIE COUNTY, RVEYORS NOTES AND SURVEYORS REPORT: 1. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS, BY OTHER THAN THE SIGNING SURVEYOR IS PROHIBITED, WITHOUT CONSENT OF THE SIGNING SURVEYOR. 2. THE LAST DATE OF FIELD WORK WAS JANUARY 14, 2021. 3. PARCEL CONTAINS 0.23 ACRES, MORE OR LESS. 4. CURRENT DESCRIPTIONS SHOWN HEREON PROVIDED BY THE CLIENT AND/OR THEIR AGENTS. LANDS SHOWN HEREON WERE NOT ABSTRACTED BY THIS OFFICE FOR RIGHT-OF-WAYS, RESERVATIONS, AGREEMENTS, AND/OR EASEMENTS OF RECORD. SUCH INFORMATION SHOULD BE OBTAINED AND CONFIRMED BY OTHERS THROUGH APPROPRIATE TITLE VERIFICATION, 5. UNDERGROUND UTILITIES, UTILITY SERVICES, FOUNDATIONS AND IMPROVEMENTS WERE NOT LOCATED AS A PART OF THIS SURVEY. 6. BEARINGS SHOWN HERON ARE BASED UPON THE PLAT OF LAKEWOOD PARK UNIT NO. 5, PER THE LINE LABELED HEREON AS (BEARING BASIS) AND ALL OTHER BEARINGS ARE RELATIVE THERETO. DISTANCES ARE IN U.S. SURVEY FEET AND DECIMAL PARTS THEREOF. 7. ELEVATIONS SHOWN HEREON ARE BASED UPON THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD'88). THE PRIMARY BENCHMARK IS CITY OF SAINT LUCIE COUNTY BENCHMARK "TONIC," HAVING AN ELEVATION OF 19.68 FEET NAVD 1988. 8. THE GPS SOFTWARE USED FOR THIS PROJECT: TDS SURVEY PRO, VERSION 4.95. /REALTIME PROCESSING IS BASED ON THE RTKLINK NETWORK. THE PROCEDURES AND NETWORK DESIGN MEETS THE GEODETIC ACCURACY STANDARDS AND SPECIFICATIONS FOR USING GPS RELATED POSITIONING AS SET FORTH BY THE FEDERAL GEODETIC CONTROL COMMITTEE IN THE MOST CURRENT PUBLICATION FOR 3RD ORDER CLASS ONE FOR HORIZONTAL CONTROL SURVEYS. 9. IN SOME INSTANCES, GRAPHIC REPRESENTATIONS AND SYMBOLS SHOWN HAVE BEEN EXAGGERATED TO MORE CLEARLY ILLUSTRATE THE RELATIONSHIP BETWEEN PHYSICAL IMPROVEMENTS AND/OR LOT LINES. THE DIMENSIONS SHOWN SHALL CONTROL THE LOCATION, OF THE IMPROVEMENTS, OVER THE SCALED POSITIONS. 10. THIS PROPERTY LIES IN FLOOD ZONE "X," ACCORDING TO FEMA FLOOD INSURANCE RATE MAP 12111CO070J, EFFECTIVE DATE FEBRUARY 15, 2012. 11. REVISIONS SHOWN HEREON DO NOT REPRESENT A "FIELD SURVEY UPDATE" UNLESS OTHERWISE NOTED. H L0 z 00 zw 0z ' 0 Q J U-) E i LL Lo.0 10:O U 0 Y W cV ._- a � V NwQ < =) °0 ° o (L-.1 ItQ w W F- f-- LL U 0 1-- � v w J ui v 0 a o0 (L o N 0 T 0 � W 0 LU z ar�,,=W;LL �� zo v 0 z � Q a >~ >U �� zz Q J Q> ¢w J = J U �a 0 m 0 �J w� 1-�. 0- L-0 W LL OU) i- DRAWN BY: FS CHECKED BY: MTO PROJECT: 21-119 DATE: 01 /14/2021 SCALE: AS SHOWN Michael T. Owen Digitally signed by Michael T. Owen Date: 2021.03.23 13:19:50-04'00' MICHAEL T. OWEN PROFESSIONAL SURVEYOR AND MAPPER SIGNATURE DATE: SHEET FLORIDA REGISTRATION #5556 1 OF 1