HomeMy WebLinkAboutAPPROVED PRODUCTAPPROVALSM1AMbDAbE
+
M14,Ml-DADE COUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
PRODUCT CONTROL SECTION
11805 Sty' 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.Eov/eeonomv
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Duration®, Duration® Premium, TruDefinition® Duration®, and TruDeffnition®
Duration® Designer Colors Collection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.16-0425.01 and consists of pages 1 through 6.
The submitted documentation was reviewed by Freddy Semino ,..
NOA No.: 17-1211.02
Expiration Date: 07/19/21
Approval Date: 12/27/18
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves a roofing system using Duration®, Durationg Premium, TruDefinition® Duration®, and
TruDefinition® Duration® Designer Colors Collection asphalt shingles manufactured by Owens Corning as
described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Specifications Product Description
Duration® 13 '/4" x 39 3/8"
Manufacturing Locations #l, 2
Duration® Premium; 13 '/4" x 39 3/8"
TruDefinition® Duration®;
TruDefinition® Duration®
Designer Colors Collection
Manufacturing Location #1, 2, 3, 4
Duration®
Manufacturing Location #1, 2, 3
Duration® Premium;
TruDefinition® Duration®;
TruDefinition® Duration®
Designer Colors Collection
Manufacturing Location #1, 2, 3,
4,5,6,7
MANUFACTURING LOCATION
1.
2.
3.
4.
5.
6.
7.
Jacksonville, FL
Memphis, TN
Savannah, GA
Irving, TX
Kearny, NJ
Medina, OH
Brookville, IN
13 1/4" x 39 3/8"
13 '/4" x 39 3/8"
TAS 110 A heavy weight, fiberglass reinforced
four tab asphalt shingle with
continuous bead of sealant.
TAS 110 A heavy weight, fiberglass reinforced
four tab asphalt shingle with large nail
area with continuous bead of sealant.
TAS 110 A heavy weight, fiberglass reinforced
four tab asphalt shingle with dashed
bead of sealant.
TAS 110 A heavy weight, fiberglass reinforced
four tab asphalt shingle with dashed
bead of sealant.
NOA No.: 17-1211.02
N110.M1•DA[)E.GOiJNTY Expiration Date: 07/19/21
Approval Date: 12/27/18
Page 2 of 6
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
PRl Asphalt Technologies, Inc.
OCF-157-02-01
TAS 100
10/26/10
OCF-156-02-01
TAS 100
10/26/10
OCF-163-02-01
TAS 100
12/10/10
OCF-164-02-01
TAS 100
12/10/10
OCF-172-02-01
TAS 100
05/26/11
OCF-179-02-01
TAS 100
02/02/12
OCF-367-02-01
TAS 100
11/08/17
OCF-368-02-01
TAS 107
11/08/17
OCF-371-02-01
TAS 100
11/08/17
OCF-372-02-01
TAS 107
11/08/17
OCF-375-02-01
TAS 100
11/08/17
OCF-376-02-01
TAS 107
11/08/17
Underwriters Laboratories, Inc.
IONK13947
TAS 107
11/12/10
11CA15662
TAS 107
05/27/11
11NB21712
TAS 107
02/18/12
12CA12180
ASTM D3462
03/01/12
R2453
ASTM D3462
10/20/17
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
4.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product Control Approved".
MIAMPEADE COUMTY
® e
NOA No.: 17-1211.02
Expiration Date: 07/19/21
Approval Date: 12/27/18
Page 3 of 6
BUILDING PERMIT REQUIREMENTS
l . Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
L1 •
iC
Fast CO&M
NOA No.: 17-1211.02
N�lAhtt:•t3RtaE.S:0UNTIf Expiration Date: 07/19/21
Approval Date: 12/27/18
Page 4 of 6
u��
(SEALANT MAY BE CONTINUOUS OR DASHED. NOT SHOWN IN THE DETAIL DRAWINGS)
rfir tr: r e'
MAXIMUM SLOPE 21:12
r -
a r r
Exposickin K pulg,
NOA No.: 17-1211.02
Expiration Date: 07/19/21
Approval Date: 12/27/18
Page 5 of 6
SLOPE GREATER THAN 21:12
AFFRO i
NOA No.: 17-1211.02
Expiration Date: 07/19/21
Approval Date: 12/27/18
Page 6 of 6
UL Product i TM
a
TGAM.R2453 - Roof -covering Materials, Impact
Resistance
Roof -covering Materials, Impact Resistance
See General Information for Roof -covering Materials, Impact Resistance
OWENS CORNING ROOFING AND ASPHALT, LLC R2453
One Owens Corning Parkway
Toledo, OH 43659 USA
Class 4 Asphalt glass fiber mat shingles, Model(s) ProEdge FLEX Hip and Ridge, ProEdge STORM Hip and Ridge, TruDefinition Duration Flex,
TruDefinition Duration Storm, TruDefinition WeatherGuard HP, WeatherGuard HP
Last Updated on 2020-04-15
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non -misleading
manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission
from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following
format: "© 2021 UL LLC"
"IAMM
mow
MIAMI-DADE COUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.gov/economy
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Self -Adhered Roof System over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 17-1016.01 and consists of pages 1 through 38.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 19-0311.04
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 1 of 38
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Modified Bitumen
Materials SBS/APP/TPO
Deck Type: Wood
Maximum Design Pressure -112.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Polyanchor 250' x 48" ASTM D 4601, A polymer woven, high performance, synthetic base
Type II sheet.
Polyglass G2 Base
108' x 36"
ASTM D 4601,
Asphalt -coated fiberglass reinforced base sheet
Type 11
Elastoshield HT
65' 8" x 3' 3-3/8"
ASTM D 6162
SBS modified asphalt coated fiberglass/polyester
reinforced base sheet.
XtraFlex SBS HT
65' 8" x 3' 3-3/8"
ASTM D 6162
SBS modified asphalt coated fiberglass/polyester
Base 650
reinforced base sheet.
Elastobase
65' 2" x 3' 3-3/8"
ASTM D 6163,
SBS modified asphalt coated fiberglass reinforced
Type I
base sheet.
Elastoflex SA V
66' 8" x 3' 3-3/H"
ASTM D 6163,
Self -adhered, fiberglass reinforced, SBS modified
Type I
bitumen membrane with a self -adhering back face and
a smooth top surface.
Elastoflex SA V FR
66' 8" x 3' 3-3/8"
ASTM D 6163,
Self -adhered, fire -rated, fiberglass reinforced, SBS
Type I
modified bitumen membrane with a self -adhering back
face and a smooth top surface.
Elastoflex SA V
66' 8" x 3' 3-3/8"
ASTM D 6163,
Self -adhered, fiberglass reinforced, SBS modified
PLUS
Type I
bitumen membrane with a self -adhering back face and
a smooth top surface.
Elastoflex SA V
66' 8" x 3' 3-3/8"
ASTM D 6163,
Self -adhered, fire -rated, fiberglass reinforced, SBS
PLUS FR
Type I
modified bitumen membrane with a self -adhering back
face and a smooth top surface.
XtraFlex SBS Base
66' 8" x 3' 3 3/s"
ASTM D 6163,
Self -adhered, fiberglass reinforced, SBS modified
SA
Type I
bitumen membrane with a self -adhering back face and
a smooth top surface.
XtraFlex SBS Glass
65' 8" x 3' 3-3/8"
ASTM D 6163,
SBS modified asphalt coated fiberglass reinforced
Base
Type I
base sheet.
Elastobase P
65' 8" x 3' 3-3/8"
ASTM D 6164,
SBS modified asphalt coated polyester reinforced base
Type I
sheet.
Elastoflex SA P 32' 10" x 3' 3-3/8" ASTM D 6164, Self -adhered, fiberglass reinforced, SBS modified
Type I bitumen membrane with a self -adhering back face and
a granule top surface.
rt"WAneCounm NOA No.: 19-0311.04
e Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 2 of 38
Elastoflex SA P FR 32' 10" x 3' 3-3/8"
ASTM D 6164,
Self -adhered, fire -rated, polyester reinforced, SBS
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface.
Polyfresko G SBS SA 32' 10" x 3' 3 14"
ASTM D 6164,
Self -adhered, fiberglass reinforced, SBS modified
Type I
bitumen membrane with a self -adhering back face and
a granule top surface.
Polyfresko G SBS SA 32' 10" x 3' 3 3/8"
ASTM D 6164,
Self -adhered, fire -rated, fiberglass reinforced, SBS
FR
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface.
Polyreflect 32' 10" x 3' 33/8"
ASTM D 6164,
Self -adhered, polymer, SBS modified bitumen
Type I
membrane with a self -adhering back face and a smooth
top surface.
XtraFlex SBS G SA 32' 10" x 3' 3-3/8"
ASTM D 6164,
Self -adhered, fire -rated, polyester reinforced, SBS
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface.
Polybond 32' 10" x 3' 3-3/8"
ASTM D 6222
Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
Polyflex 32' 10" x 3' 3-3/8"
ASTM D 6222
Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
XtraFlex APP S 32' 10" x 3' 3-3/8"
ASTM D 6222
Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
PolyKool 32' 10" x 3' 33/8"
ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
Type I
bitumen membrane with a self -adhering back face and
a white film laminate on the top surface.
XtraFlex Kool APP S 32' 10" x 3' 33/8"
ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
SA
Type 1
bitumen membrane with a self -adhering back face and
a white film laminate on the top surface.
Polyflex SA P 32' 10" x 3' 33/8"
ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
Type I
bitumen membrane with a self -adhering back face and
a granule top surface.
Polyflex SA P FR 32' 10" x 3' 3-'/8"
ASTM D 6222,
Self -adhered, fire -rated, polyester reinforced, APP
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface.
Polyfresko G APP SA 32' 10" x 3' 33/8"
ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
Type I
bitumen membrane with a self -adhering back face and
a granule top surface.
Polyfresko G APP SA 32' 10" x 3' 3-;/8"
ASTM D 6222,
Self -adhered, fire -rated, polyester reinforced, APP
FR
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface
XtraFlex APP G SA 32' 10" x 3' 33/8"
ASTM D 6222,
Self -adhered, fire -rated, polyester reinforced, APP
Type I
modified bitumen membrane with a self -adhering back
face and a granule top surface.
IRIMIRL
r�uahtFnaoe a 5UNW-M
NOA No.: 19-0311.04
•now
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 3 of 38
Polyglass APP Base
65' 8" x 3' 3 3/A"
ASTM D 6509,
APP modified asphalt coated fiberglass reinforced
Type I
base sheet.
PG 100
1, 3, 5, 50, 55 gal,
ASTM D41
A penetrating solution of solvent and a blend of
tube or 17 oz. spray
selected asphalts used to promote adhesion.
can
PG 350
1, 3, 5, 50, 55 gal. or
ASTM D3019
A fibered rubberized adhesive designed for use with
tube
Type III
modified bitumen membranes.
PG 400
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use in
tube
ASTM D3409
dry or damp conditions.
PG 425
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use in
tube
ASTM D3409
dry or damp conditions.
PG 450
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement.
tube
PG 500
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use
tube
with modified bitumen membranes.
POLYPLUS 35
1, 3, 5, 50, 55 gal. or
ASTM D3019
A fibered rubberized adhesive designed for use with
tube
Type III
modified bitumen membranes.
POLYPLUS 45
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement.
tube
POLYPLUS 50
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use
tube
with modified bitumen membranes.
XtraFlex 10
1, 3, 5, 50, 55 gal,
ASTM D41
A penetrating solution of solvent and a blend of
tube or 17 oz. spray
selected asphalts used to promote adhesion.
can
XtraFlex 35
1, 3, 5, 50, 55 gal. or
ASTM D3019
A fibered rubberized adhesive designed for use with
tube
Type III
modified bitumen membranes.
XtraFlex 50 Premium
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use
Modified Wet/Dry
tube
with modified bitumen membranes.
Cement
WB-3000
5 gallon pail
Proprietary
A low-VOC, water -based acrylic primer to enhance
adhesion of self -adhered membranes.
Immak
Mu►rtFOEwE cour�rY NOA No.: 19-0311.04
"' a Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 4 of 38
APPROVED INSULATIONS:
TABLE 2
Product Name
Product Description
Manufacturer
(With Current NOA)
Polytherm-H
Polyisocyanurate foam insulation
Polyglass USA, Inc.
Polytherm
Polyisocyanurate foam insulation
Polyglass USA, Inc.
Polytherm G
Polyisocyanurate foam insulation
Polyglass USA, Inc.
XtraFlex Polyiso
Polyisocyanurate foam insulation
Polyglass USA, Inc.
XtraFlex Polyiso G
Polyisocyanurate foam insulation
Polyglass USA, Inc.
ACFoam-II
Polyisocyanurate foam insulation
Atlas Roofing Corp
ACFoam-III
Polyisocyanurate foam insulation
Atlas Roofing Corp
Structodek High Density Fiberboard Roof
Wood fiber insulation board
Blue Ridge Fiberboard, Inc.
Insulation
DensDeck, DensDeck Prime
Gypsum insulation board
Georgia-Pacific Gypsum LLC
H-Shield
Polyisocyanurate foam insulation
Hunter Panels, LLC
H-Shield CG
Polyisocyanurate/perlite composite insulation
Hunter Panels, LLC
ENRGY-3
Polyisocyanurate foam insulation
Johns Manville Corp.
Fesco Board
Expanded mineral fiber
Johns Manville Corp.
Multi -Max FA-3
Polyisocyanurate foam insulation
Rmax Operating, LLC.
SECUROCK Gypsum -Fiber Roof Board
Fiber reinforced coverboard
United States Gypsum
Corporation
IffMIAMMADE CONOA No.: 19-0311.04
' "o ►UNTY Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 5 of 38
APPROVED FASTENERS:
Fastener
Number
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
17
18
TABLE 3
Product
Product
Name
Descrimtion
Dekfast DF-#12-PH3
Insulation fastener for wood,
steel and concrete decks
Dekfast DF-#14-PH3
Insulation fastener for wood,
steel and concrete decks
Dekfast DF-# 15-PH3
Insulation fastener for wood,
steel and concrete decks
Dekfast PLT-H-2-7/8
Galvalume hex stress plate.
#14 Roofgrip
Insulation and membrane
fastener
Flat Bottom Metal Plate
A2-SS aluminized steel plate
Trufast #14 HD Fastener
Insulation fastener for steel and
wood decks
Trufast 3" Metal Insulation
Round Galvalume AZ50 steel
Plate
plate
Polygrip Fasteners #12
Insulation fastener for wood,
steel and concrete decks
Polygrip Fastener #14
Insulation fastener for wood,
steel and concrete decks
Polygrip Fastener 415
Insulation fastener for wood,
steel and concrete decks
Polygrip Hex Plates
Galvalume hex stress plate.
OMG 3 in. Ribbed
Galvalume stress plate.
Galvalume Plate (Flat)
OMG 3" Galvalume Steel
Galvalume stress plate.
Plate
Dekfast PLT-R-3
Galvalume stress plate.
Millennium One -Step
A two component, low rise,
Foamable Adhesive
polyurethane foam adhesive
Millennium One Step Green
A two component, low rise,
Foamable Insulation
polyurethane foam adhesive
Adhesive
Millennium PG-1 Pump
A two component, low rise,
Grade Adhesive
polyurethane foam adhesive
APPROVED
Manufacturer
Dimensions (With Current NOA)
SFS Group USA, Inc.
Various SFS Group USA, Inc.
Various SFS Group USA, Inc.
2 7/8" x SFS Group USA, Inc.
3 '/4"
Various OMG, Inc.
3" square OMG, Inc.
Altenloh, Brinck & Co.
U.S., Inc.
3.23 round Altenloh, Brinck & Co.
3" round U.S., Inc.
Various Polyglass USA, Inc
Various Polyglass USA, Inc.
Various Polyglass USA, Inc.
2 7/8" x
Polyglass USA, Inc
3 '/4"
3" round
OMG, Inc.
3" round
OMG, Inc.
3" round
SFS Group USA, Inc.
Adco Products, Inc. dba
Royal Adhesives &
Sealants
Adco Products, Inc. dba
Royal Adhesives &
Sealants
Adco Products, Inc. dba
Royal Adhesives &
Sealants
NOA No.: 19-0311.04
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 6 of 38
APPROVED SURFACING:
TABLE 4
Chosen components must be applied according to manufacturer's
application instructions.
Number Product
Product
Application
Specification
Manufacturer
Name
Description
Rate
1. Gravel
To be installed in a flood coat
400 lbs/sq
N/A
Generic
of approved asphalt at 60 lbs/sq
2. Slag
To be installed in a flood coat
300 lbs/sq
N/A
Generic
of approved asphalt at 60 lbs/sq
3. KM Acryl 15
A premium white or tinted
1-1 %2 gal/sq
ASTM D6083
Polyglass USA,
elastomeric acrylic based roof
Inc.
coating (water -based). A
polyester fabric may be used
for reinforcement with this
coating.
4. KM Acryl 15 QS
A premium white or tinted
quick setting, elastomeric
acrylic based roof coating
(water -based). A polyester
fabric may be used for
reinforcement with this
coating.
1-1'/2 gal/sq ASTM D6083 Polyglass USA,
Inc.
5. KM Acryl 25
A premium white or tinted
l-1'/2 gal/sq
ASTM D6083 Polyglass USA,
elastomeric acrylic based roof
Inc.
coating (water -based). A
polyester fabric may be used
for reinforcement with this
coating.
6. KM Acryl 25 QS
A premium white or tinted
1-1'/2 gal/sq
ASTM D6083 Polyglass USA,
quick setting, elastomeric
Inc.
acrylic based roof coating
(water -based). A polyester
fabric may be used for
reinforcement with this
coating.
7. KM -PS 4220
A single component, solvent,
1.25 gaUsq
ASTM D6694 Polyglass USA,
white or tinted, silicone
Inc.
coating.
8. KM -PS #250
A premium grade high solids,
1.25 gaUsq
ASTM D6694 Polyglass USA,
white or tinted, single
Inc.
component, moisture cure,
fluid applied silicone coating
APPROVED
NOA No.: 19-0311.04
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 7 of 38
APPROVED SURFACING:
TABLE 4
Chosen components must be applied according to manufacturer's application instructions.
Number Product Product
Application
Specification
Manufacturer
Name Description
Rate
9. PG 300 An asphalt cutback fibered roof
1 %2-2 gal/sq
ASTM D4479
Polyglass USA,
coating. May be applied by
Inc
brush or spray equipment to
rejuvenate aged BUR
10. PG 600 Non-fibered aluminum roof
%2-1 gal/sq
ASTM D2824
Polyglass USA,
coating.
Type I
Inc
11. PG 650
12. PG 700
13. PG 700 QS
14. PG 800
15. PolyBrite 70
16. PolyBrite 70 QS
17. PolyBrite 90
APPROVED
Fibered aluminum roof coating. 1 %2-2 gal/sq
A premium white or tinted
elastomeric acrylic based roof
coating (water -based). A
polyester fabric may be used
for reinforcement with this
coating.
A premium white or tinted
quick setting, elastomeric
acrylic based roof coating
(water -based). A polyester
fabric may be used for
reinforcement with this
coating.
An asphalt based, non-fibered
clay emulsion
A premium white or tinted
elastomeric acrylic based roof
coating (water -based). A
polyester fabric may be used
for reinforcement with this
coating.
A premium white or tinted
quick setting, elastomeric
acrylic based roof coating
(water -based). A polyester
fabric may be used for
reinforcement with this
coating.
A premium grade high solids,
white or tinted, single
component, moisture cure,
fluid applied silicone coating
1-1'/z gal/sq
1-1 % gal/sq
ASTM D2824 Polyglass USA,
Type III Inc.
ASTM D6083 Polyglass USA,
Inc.
ASTM D6083 Polyglass USA,
Inc.
3 gal/sq in two ASTM D1227 Polyglass USA,
coats Inc.
1-1 %2 gal/sq ASTM D6083 Polyglass USA,
Inc.
1-1'/2 gal/sq ASTM D6083 Polyglass USA,
Inc.
1.25 gal/sq ASTM D6694 Polyglass USA,
Inc.
NOA No.: 19-0311.04
Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 8 of 38
APPROVED SURFACING:
TABLE 4
Chosen components
must be applied according to manufacturer's
application instructions.
Number
Product
Product
Application
Specification
Manufacturer
Name
Description
Rate
18.
PolyBrite 95
A single component, white or
1.25 gaUsq
ASTM D6694
Polyglass USA,
tinted, solvent, moisture cure
Inc
silicone coating.
19.
POLYPLUS 60
Non-fibered aluminum roof
%2-1 gal/sq
ASTM D2824
Polyglass USA,
coating.
Type I
Inc.
20.
POLYPLUS 65
Fibered aluminum roof coating.
1 %2-2 gal/sq
ASTM D2824
Polyglass USA,
Type III
Inc.
21.
XtraFlex 60 Aluminum
Non-fibered aluminum roof
t/2-1 gal/sq
ASTM D2824
Polyglass USA,
Roof Coating
coating.
Type I
Inc.
22.
XtraFlex 65 Aluminum
Fibered aluminum roof coating.
1'h-2 gal/sq
ASTM D2824
Polyglass USA,
Roof Coating Fibered
Type III
Inc.
23.
XtraFlex 70 Premium
A premium white or tinted
1-1 %2 gal/sq
ASTM D6083
Polyglass USA,
Acrylic FR Roof
elastomeric acrylic based roof
Inc.
Coating
coating (water -based). A
polyester fabric may be used
for reinforcement with this
coating.
24.
XtraFlex 80 Emulsion
An asphalt based, non-fibered
3 gal/sq in two
ASTM D1227
Polyglass USA,
Roof Coating
clay emulsion
coats
Inc.
25.
XtraFlex 30
An asphalt cutback fibered roof
1 %2-2 gal/sq
ASTM D4479
Polyglass USA,
Bituminous Roof
coating. May be applied by
Inc.
Coating Fibered
brush or spray equipment to
rejuvenate aged BUR
26.
XtraFlex SRC 8000
A single component, white or
1.25 gaUsq
ASTM D6694
Polyglass USA,
tinted, solvent, moisture cure
Inc
silicone coating.
27.
XtraFlex SRC 9600
A premium grade high solids,
1.25 gaUsq
ASTM D6694
Polyglass USA,
white or tinted, single
Inc
component, moisture cure,
fluid applied silicone coating
monk
arwrrFaEwe courm NOA No.: 19-0311.04
I Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 9 of 38
EVIDENCE SUBMITTED:
Test Agency
Test Name/Report
Report No.
Date
Factory Mutual Research
4470
2W7A7.AM
08.04.94
Corporation
4450
2D5A9.AM
06.22.99
4470
3000857
01.12.00
4470
3004091
01.12.00
4470
3001334
02.15.00
4470
3014692
08.05.03
4450
3014751
08.27.03
4450
3019317
06.30.04
4470
3024311
11.01.06
4470
3012321
07.29.07
4470
3036182
07.31.09
4470
RR202591
10.22.15
Trinity ERD
TAS 114
11752.09.99-1
02.08.00
TAS 114
11751.05.03
05,30.03
TAS 117(B)-ASTM D903
020841.06.04
06.02.04
TAS 114
02762.03.05
03.30.05
TAS 114
02764.09.05
09.09.05
TAS 114
P1739.01.07
01.23.07
TAS 114
P1734.07.06-R1
02.27.07
TAS 117(B)-ASTM D6862
C8500SC.11.07
11.30.07
TAS 114 & FM 4470
P7864SC.11.07
11.30.07
TAS 114(D) — ASTM D1876
P10070.10.08
10.09.08
TAS 114 (H)
P13760.09.09
09.10.09
FM 4470 & TAS 114
P33970.03.11
03.15.11
ASTM D6163 / ASTM D 4601
P33960.03.11
03.15.11
ASTM D6163
P37590.03.13-2-R1
02.05.13
ASTM D6164
P37590.03.13-3A
03.06.13
TAS 114
P1738.02.07-R2
04.29.13
TAS 114 & TAS 117 (B)
11757.04.01-1-R1
04.30.13
ASTM D6509
P37590.03.13-1-R1
06.26.13
ASTM D6222
P37590.03.13-5-R1
07.01.13
ASTM D6164
P37590.07.13-1
07.02.13
TAS 114 & FM 4474
P41630.08.13
08.06.13
ASTM D4601 / TAS 117
P45940.09.13
09.04.13
ASTM D6222
P37590.09.13
09.12.13
ASTM D4601 / TAS 117
P45970.05.14
05.12.14
ASTM D6162
SC5170.05.15
05.08.15
ASTM D6162
SC5170.12.15-1
12.29.15
TAS 114 & FM 4474
PLYG-SC8905.05.16-1
05.17.16
TAS 114 & TAS 117 (B)
11757.12.00-1-R2
04.05.17
PRI Construction Materials
ASTM D6222
PUSA-061-02-02
01.28.08
Technologies
ASTM D6163
PUSA-064-02-02
02.27.08
ASTM D6222
PUSA-062-02-02
12.04.08
ASTM D6694
PUSA-134-02-01
05.16.14
MIAMI-DADE COuf+rt r NOA No.: 19-0311.04
mmlEmmmOr Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 10 of 38
EVIDENCE SUBMITTED:
Test Agency Test Name/Report
Report No.
Date
ASTM D6694
PUSA-135-02-01
05.16.14
TAS 117(B)
PUSA-202-02-01
05.08.17
FM 4470 & TAS 114
PUSA-202-02-02
05.23.17
mmakh
MIAr1aDEwE cOurmr NOA No.: 19-0311.04
"a o Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 11 of 38
Membrane Type: SBS/APP
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24" spans with 8d common nails at 4" o.c.
or 48 wood screws at 6" o.c.
System Type E(1): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Elastobase, Elastobase P, Elastoshield HT, Polyanchor, XtraFlex SBS Glass Base
or XtraFlex SBS HT Base 650 fastened to the deck as described below:
Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8" diameter tin caps spaced 8"
o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet.
Ply Sheet: ` One or mare plies of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex
SA V PLUS FR or XtraFlex SBS Base SA self -adhered.
Membrane: One ply of Elastoflex SA P,LElastoflex SA P FR, Polyflex SA P, Polyflex SA P FR, Polyfresko
G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Polyfresko G SBS SA FR,
PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA or XtraFlex SBS G SA
self -adhered.
5swurLuing,Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) ' required fire classification.
Maximum Design
Pressure: -52.5 psf, (See General limitation 47.).
MtWtbADE C6UNTY NOA No.: 19-0311.04
"' • Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 30 of 38
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the
top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be Tx T maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using
spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one
at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener
spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing
Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OFT IS ACCEPTANCE
rnUUManaue Couner7r NOA No.: 19-0311.04
UJUNU19e Expiration Date: 10/11/22
Approval Date: 03/21/19
Page 38 of 38
Base Sheet: — One or more layers "Duflex", "XtraFlex APP S" or "Polyflex", heat fused or mechanically fastened; or one or
more layers "Elastobase", "Elastobase Vented Base", "XtraFlex SBS Glass Base", "ElastoFlex V", "XtraFlex SB5 Glass Interply"
or "ElastoFlex V-C", hot mopped or heat fused; or Type G2, hot mopped or mechanically fastened.
Ply Sheet (Optional):— One or more layers "Duflex", "XtraFlex APP S" or "Polyflex", heat fused; or one or more layers
"Elastobase", "Elastobase Vented Base", "XtraFlex SBS Glass Base", "ElastoFlex V% "XtraFlex SBS Glass Interply" or
"ElastoFlex V-C", hot mopped or heat fused; or one or more layers Type G2, hot mopped or mechanically fastened.
Membrane: — "Duflex G FR", "XtraFlex APP Dual", "Polyfresko G FR", "XtraFlex APR G FR% "XtraFlex APP G HP" or
"Polyflex G FR" (modified bitumen), heat fused.
18. Deck C-15/32 incline: 1/2
insulation: — Polyisocyanurate (2-in. thick minimum), Glass fiber (15/16-in. thick minimum), perlite/polyisocyanurate
composite, perlite/urethane composite (2-in. thick minimum).
Base Sheet — One or more layers "Duflex", "XtraFlex APP S" or "Polyflex", heat fused or mechanically fastened; or one or
more layers "Elastobase", "Elastobase Vented Base", "XtraFlex SBS Glass Base", "ElastoFlex V", "XtraFlex SBS Glass Interply"
or Type G2, hot mopped or mechanically fastened.
Ply Sheet (Optional): — One or more layers "Duflex", "XtraFlex APP S" or "Polyflex", heat fused; or one or more layers
"Elastobase", "Elastobase Vented Base", "XtraFlex SBS Glass Base", "ElastoFlex W, "XtraFlex SBS Glass Interply", "ElastoFlex
V-C" or Type G2, hot mopped or mechanically fastened.
Membrane: — "ElastoFlex S6 G", "ElastoFlex S6 G-C" or "Polyfresko G SBS" (modified bitumen), hot mopped.
19. Deck C-15/32 incline: 1
Insulation: — Minimum 1/4 in- thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Primee
Roofboard" or "DensDeck DuraGuardTM' Roofboard", or 1-in. thick perlite, wood fiber or Glass fiber, mechanically fastened.
Ply Sheet: — Type G2, mechanically fastened.
Membrane: — "Polyflex" or "XtraFlex APP S", heat welded.
Surfacing: — Monsey Products "Endure Aluminum Roof Coating", "Weather Check" or "Pro -Grade Aluminum Roof
Coating" applied at 1-1/2 gal./100-ftz; or Brewer Co "Fortress 5001 Asphalt Emulsion" applied at 4-gal./100-ftz., followed
by "PolyFlus 60", applied at 3/4 to 1 gal./100-ft2
20. Deck C-15/32 Incline: 2-1/2
Barrier Board: — Minimum 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDecke Roofboard" or "DensDeck Primee
Roofboard" or "DensDeck DuraGuard'`"' Roofboard" with all buttjoints staggered a minimum of 6-in. from the plywood
roof deck joints.
Base Sheet — Type G2, mechanically fastened-
embrane: — "Polyflex G FR", "XtraFlex APP G HP", "XtraFlex APP G FR" or "Polyfresko G FR", heat fused.
21. Deck C-15/32 Incline: 2
insulation (Optional): — Polyisocyanu rate, perlite, wood fiber or polyisocyanurate/perlite board, any thickness.
Barrier Board: — Minimum 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDecke Roofboard" or "DensDeck Primee
Roofboard" or "DensDeck DuraGuard-1 Roofboard", mechanically fastened with all butt joints staggered a minimum of
6-in. from the plywood roof deck joints.
Base Sheet: — "Elastobase", "XtraFlex SBS Glass Base" (poly/sand), mechanically fastened or "ElastoFlex SA V Plus FR",
"ElastoFlex SA V FR" or "ElastoFlex SA V FR Base Vent" (self -adhered).
Ply Sheet (Optional): — "Elastobase", "XtraFlex SBS Glass Base"(poly/sand), heat fused or mechanically fastened, or
"ElastoFlex SA V Pius FR", "ElastoFlex SA V FR" or "ElastoFlex SA V FR Base Vent", (self -adhered).
Membrane: — "Polyflex SA P FR", "Polyfresko G SA P FR", "ElastoFlex SA P FR", "Polyfresko G SBS $A P FR", "ElastoFlex SA
V FR HT', (self -adhered) or "Polyflex G FR", "XtraFlex APP G HP", "XtraFlex APP G FR", "Polyfresko G FR", "Duflex
Flex SBS
"XtraFlex APP Dual", "ElastoFlex S6 G FR% "Polyfresko G SBS FR% "ElastoFlex VG FR', "XtraFlex SBS POLY G", "
POLY G T', "XtraFlex SBS Glass G", "XtraFlex SBS Glass GT" or "Elastoshield TS G FR", heat fused.
Incline: 1/2
22. Deck C-15/32
Insulation (Optional):— Polyisocyanurate 1-1/2 in. thick (minimum) with all joints staggered 6-in. (minimum) from the
plywood joints.
Base Sheet —Type G2, mechanically fastened followed by "Elastobase", "Elastobase Vented Base" or "XtraFlex SBS Glass
Base", mechanically fastened.
Ply Sh (Optiona — "ElastoFlex SA V Plus FR", "ElastoFlex SA V FR" or "ElastoFlex SA V FR Base Vent", (self -adhered).
Membrane: — "Polyflex SA P FR", "Polyfresko G SATTZ7, "ElastoFlex SA P FR", "Polyfresko G SBS SA P FR", or "Duflex G
FR", "XtraFlex APP Dual", "Polyflex G FR", "XtraFlex APP G HP", "XtraFlex APP G FR", "ElastoFlex S6 G FR", "Polyfresko G
SBS FR", "ElastoFlex VG FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T", "XtraFlex SBS Glass G", "XtraFlex SBS Glass
GT" or "Elastoshield TS G FR", heat fused.
23. Deck NC Incline: 2
insulation (Optionap: — "Polytherm ® " or Atlas Roofing Corp. "ACFoam iII" or "ACFoam II" or Hunter Panels "H-Shield",
any thickness.
Base Sheet — "Elastobase", "XtraFlex SBS Glass Base"(poly/sand), heat fused or mechanically fastened or "ElastoFlex SA
V FR", "ElastoFlex SA V Pius FR" or "ElastoFlex SA V FR Base Vent", (self -adhered).
Membrane: — " Polyflex SA P FR", "Polyfresko G SA P FR", "ElastoFlex SA P FR", "Polyfresko G SBS SA P FR% "ElastoFlex SA
V FR HT", (self -adhered) or "Polyflex G FR% "XtraFlex APP G HP% "XtraFlex APP G FR", "Polyfresko G FR", "XtraFlex APP
Dual", "Duflex G FR% "ElastoFlex S6 G FR", "Polyfresko G SBS FR", "ElastoFlex VG FR", "XtraFlex SBS POLY G", "XtraFlex SBS
POLY G 7, "XtraFlex SBS Glass G", "XtraFlex SBS Glass GT" or " Elastoshield TS G FR", heat fused.
24. Deck C-15/32 Incline: 3
Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or polyisocyanurate/perlite board, any thickness.
Barrier Board: — Minimum 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime®
Roofboard" or "DensDeck DuraGuardT"` Roofboard", mechanically fastened with all buttjoints staggered a minimum of
6-in. from the plywood roof deckjoints.
Sam Sheet — "Elastobase", "XtraFlex SBS Glass Base" (poly/sand), mechanically fastened.
Ply Sheet (Optional): —' ElastoFlex SA V Pius FR", "ElastoFlex SA V FR" or "ElastoFlex SA V FR Base Vent", (self -adhered).
Membrane: — "ElastoFlex S6 G FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T" or "Polyfresko G SBS FR", heat fused.
25. Deck NC Incline: 3
Insulation (Optional): — "Polytherm" or Atlas Roofing Corp. "ACFoam III" or "ACFoam 11" or Hunter Panels "H-Shield",
any thickness.
Barrier Board (Optional): — Minimum 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck
Prime® Roofboard" or "DensDeck DuraGuard' Roofboard", mechanically fastened.
Base Sheet — "ElastoFlex SA V Plus FR", "ElastoFlex SA V FR" or "ElastoFlex SA V FR Base Vent" (self -adhered).
Membrane: — "Polyflex SA P FR", "Polyfresko G $A P FR% "ElastoFlex SA P FR" or "Polyfresko G SBS SA P FR" (self -
adhered).
26. Deck NC incline: 1/2
Base Sheet: — Type Gi or Type G2, mechanically fastened.
Membrane: — "Polyflex G", "XtraFlex APP G HP TOR", "XtraFlex APP G" or "Polybond G", heat fused.
27. Deck NC Incline: 3
Membrane: — "Polyflex SA P FR", "Polyfresko G SA P FR% "Polyfresko G SBS SA P FR"or "ElastoFlex SA P FR" (self -
adhered).
28. Decic NC Incline: 1
insulation (Optional): — Polyisocyanurate, any thickness.
Barrier Board (Optional): — Minimuml/2 in. thick gypsum board or minimum 1/4 in. thick Georgia-Pacific Gypsum LLC
"DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuardTM Roofboard" or minimum 1/4-in.
thickUnited States Gypsum Co. "SECUROCKTM Roof Board Type FRX-G".