HomeMy WebLinkAboutAPPROVED #30 1/16/2021 Florida Building Code Online
Business & ProfessionalRegulation
BCIS Home ( Log In 1 User Registration j Hot Topics I Submit Surcharge { Stats&Facts t Publications f contact Us ( BCIS Site Map Links j Search
9 fly
4w&rProduct Approval
USER:Public User
CR'l
Product Approval Menu>Product or Application Search>Application List>Application Detail
a FL# FL10450-1113
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Tarco Roofing
Address/Phone/Email One Information Way
Suite 225
Little Rock,AR 72202
(254)913-7750
smohseen@tarcoroofing.com
Authorized Signature Shaik Mohseen
smohseen@tarcoroofing.com
Technical Representative Shaik Mohseen
Address/Phone/Email 2403 Taylors Valley Road
Belton,TX 76513
(254)913-7750
smohseen@tarcoroofing.com
Quality Assurance Representative Shaik Mohseen
Address/Phone/Email 2403 Taylors Valley Road
Belton,TX 78717
(254)939-3775 Ext210
smohseen@tarcoroofing.com
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 09/26/2022
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10450 R13 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D3909 2014
ASTM D4533 2015
ASTM 04798 ZU11
ASTM D4869 2016
ASTM D5035 2011
ASTM 136164 2011
ASTM D6380 2013
FM 4474 2011
www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqudsDrIH614890v%2fSoZ)1/grzyCLUr7kavhktJH3XFXTeA%3d%3d 112
1/1 612 02 1 Florida Building Code Online
FRSA/TRI Sixth Edition 2018
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/19/2020
Date Validated 09126/2020
Date Pending FBC Approval 10/02/2020
Date Approved 12/15/2020
Summary of Products
FL# Model,Number or Name Description
10450.1 Tarco Roof Underlayments Roof underlayments for use in prepared roof assemblies
7 Limits of Use Installation Instructions
Approved for use in HVH2:No FL10450 R13 II 2020 09 18 FINAL ER TARCO UNDERLAYMENTS FL10450-
Approved for use outside HVH2:Yes Rl .pdf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-217.5 Created by Independent Third Party:Yes
Other: 1.)The design pressure herein pertains to Evaluation Reports
one particular bonded underlayment application for FL10450 R13 AE 2020 09 18 FINAL ER TARCO UNDERLAYMENTS FL10450-
use beneath adhesive-set tile systems.Refer to ER R13.pdf
Section 5.6.2 for details,and other bonded Created by Independent Third Party:Yes
underlayment systems.2.)Refer to ER Section 5 for
Limits of Use.
%ae3c tkexY
Contact Us;:2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this
entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,
effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for
official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an
email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
El
Credit Card
Safe
IIII I!
www.floridabuilding.org/pr/pr_app_otl.aspx?param=wGEVXQwtDqudsDrlH6[4890v%2fSoZjVgrzyCLUr7kavhktJH3XFXTeA%3d%3d 2/2
NEMOI etc.
Certificate of Authorization#32455
U( 353 Christian Street, Unit 413
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION .O.
Tarco Roofing Evaluation Report 10880.07.08-R13
One Information Way,Suite 225 FL10450-R13
Little Rock,AR 72202 Date of Issuance:07/11/2008
(254)913-77SO Revision 13:09/18/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 7th Edition(2020) Florida Building Code sections noted herein.
DESCRIPTION: Tarco Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "MEMO(etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 11.
Prepared by: -
t
c :L;;
Robert J.M.Nieminen,P.E. ., r'-`,. The facsimile seal appearing was authorized by Robert
Jc 'rr.'.
Florida Registration No.59166,Florida OCA ANE1983 s r r�,',.a Nieminen,P.E.on 09/18/2020. This does not serve as an
- electronically signed document-
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
2- Robert Nieminen,P-E-does not k---nor w;lt a�qu;��,a financial interest in any company manufacturing or aistnbuting prooucis for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018,NEMO ETC,LLC
ONEMO I etc.
ROOFING COMPONENT EVALUATION
SCOPE:1.
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Tarco Roof Underlayments,as produced by Tarco Roofing, have demonstrated compliance
with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set
forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind resistance FM 4474 2011
1507.1.1/R905.1.1 Material standard ASTM D226 2009
1507.1.1/R905.1.1 Material standard ASTM D4869 2016
1507.1.1,1507.2.4,1507.2.9.2/R905.1.1, Material standard ASTM D1970 2015
R905.2.8.2
1507.2.9.2,1507.6.5/R905.2.8.2,R905.5.4 Material standard ASTM D3909 2014
1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tear strength ASTM D4533 2015
R905.1.1.1(2&3,Exception),R905.1.1.1(5)
1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tensile strength ASTM D5035 2011
R905.1.1.1(2&3,Exception),R905.1.1.1(5)
1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869 2016
1507.2.9.2,1507.6.5/R905.2.8.2,R905.5.4 Material standard ASTM D6380 2013
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6164 2011
TAS 110 Accelerated Weathering ASTM D4798 2011
1, REFERENCES'
Entity Examination Reference Date Entity Examination Reference Date
ERD(TST6049) D4869,D5035 C30280.12.09 12/11/2009 ERD(TST6049) ASTM D4533 CTR-SC16080.10.17 10/25/2017
ERD(TST6049) FRSA/TRI T33190.08.10 08/06/2010 PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003
ERD(TST6049) ASTM D1970 T32S30.08.10 08/17/2010 PRI(TST5878) ASTM D1970 BRY-017-02-01 08/11/2003
ERD(TST6049) ASTM D4798 C30280.12.09-R2 08/20/2010 PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004
ERD(TST6049) FM 4474 T37610.07.11 06/29/2011 PRI(TST5878) ASTM D226 TOT-015-02-02 05/24f2004
ERD(TST6049) ASTM D3909 T40780.04.12 04/06/2012 PRI(TST5878) ASTM D4869 TOT-009-02-01 09/14/2004
ERD(TST6049) ASTM D6380 T40790.04.12 04/06/2012 PRI(TST5878) ASTM D4869 TOT-009-02-02 09/14/2004
ERD(TST6049) ASTM D6164 T35410.04.12 04/18/2012 PRI(TST5878) ASTM D226 TOT-041-02-01 05/24/2006
ERD(TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013 M-D(CER1592) FBC HVHZ 16-1116.09 01/12/2017
ERD(TST6049) FRSA/TRI T43930.09.13-R2 09/11/2013 NEMO(TST6049) FRSA/TRI TAR-SC8020.06.18 06/05/2018
ERD(TST6049) D226&D4869 SC4950.02.14-R2 06/25/2014 NEMO(TST6049) Tensile adhesion 4S-TAR-18-002.07.18-1 07/20/2018
ERD(TST5049) ASTM D1970 TAR-SC9480.15 07/02/2015 NEMO(TST6049) FRSA/TRI 4S-TAR-18-002.07.18-2 07/20/2018
ERD(TST6049) FM 4474 TAR-SC8020.14 12/03/2015 NEMO(TST6049) TAS 117(B) 4i-CTR-I9-SSCRT-01.A 04/10/2019
ERD(TST6049) FM 4474 TAR-SC5670.03.16 03/21/2016 NEMO(TST6049) ASTM D4798 4j-TAR-I9-SSUDL.01.A 08/27/2019
ERD(TST6049) FM 4474 T6460.06.07-R2 05/26/2017 Tarco Roofing Adhesive comp Affidavit 12/15/2015
ERD(TST6049) A5TM DZZ6 03/17/ZU17 TarCO"onng FBC CroSS-List Listing Agreement 01/20/2020
ERD(TST6049) FBC 1507.1A TAR-SC16115.17 10/02/2017 UL,LLC.(QUA9625) QA Service Confirm(IND) 11/22/2016
ERD(TST6049) FRSA/TRI TAR-SC16115.17 10/02/2017 UL,LLC.(QUA9625) QA Service Confirm(PA) 06/28/2017
UL,LLC.(QUA9625) QA Service Confirm(TX) 08/13/2018
NEMO ETC,LLC Evaluation Report 10880.07.08-1113
Certificate of Authorization F/3Z455 7'"EDITION(ZUZO)FBC NON-HVHZ EVALUATION FL10450-R13
Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020
Page 2 of 11
NNEM10 I etc.
4. PROULICT r •
Product Material Standard Plant(s) Description
4.1 LeakBarrier MS300Ice and ASTM D1970 Belton,TX self-adhering,glass mat reinforced,mineral
Water Armor Greencastle,PA surfaced,SBS modified roof underlayment
4.2 TopShield Ice&Water G300 ASTM D1970 Belton,TX self-adhering,glass mat reinforced,mineral
Greencastle,PA surfaced,SBS modified roof underlayment
4.3 LeakBarrier PS200"T Ice and ASTM D1970 and Belton,TX self-adhering,glass mat reinforced,fabric
Water Armor FRSA/TRI 09-18 Greencastle,PA surfaced,SBS modified roof underlayment
4.4 LeakBarrier°PS200mu Ice ASTM D1970 Belton,TX self-adhering,glass mat reinforced,smooth
and Water Armor Greencastle,PA poly film surfaced,SBS modified roof
underlayment
4.5 LeakBarrier NR600 Ultra Ice ASTM D1970 and Greencastle,PA self-adhering,polyester-fabric surfaced,SBS
and Water Armor FRSA/TRI 09-18 modified roof underlayment
4.6 LeakBarrier®SS400 Ice and ASTM D1970 Belton,TX self-adhering,fiberglass reinforced,smooth
Water Armor Greencastle,PA surfaced modified underlayment
4.7 Tarco 30 ASTM D226,Type II Belton,TX asphalt-saturated organic felt
Greencastle,PA
4.8 LeakBarrier EasyLay ASTM D226,Type it Belton,TX asphalt-coated polyester fabric roof
Greencastle,PA underlayment
4.9 Fiberglass Mineral Surfaced ASTM D3909 Greencastle,PA glass-fiber-reinforced,asphalt-coated,granule
Roll Roofing surfaced underlayment used as a valley liner
4.10 ASTM Organic Mineral ASTM D6380,Class M Greencastle,PA asphalt-saturated organic roll roofing sheet
Surface Tile Underlayment
4.11 LeakBarrier EasyMop'"SBS FRSA/TRI April 09-18 Greencastle,PA polyester reinforced,SBS modified bitumen
roofing underlayment
4.12 LeakBarrier EasyLay UDL 1507.1.1.1(2&3, Gujarat,India woven-polymeric scrim with a textured fabric
15 Exception),1507.1.1.1(5)/ on the top surface
R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
4.13 LeakBarrier EasyLay UDL 1507.1.1.1(2&3, Gujarat,India woven-polymeric scrim with a textured fabric
30 Exception),1507.1.1.1(5)/ on the top surface
R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
15. •
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-Dade
Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning
the use of foam plastic insulation.
NEMO ETC,LLC Evaluation Report 10880.07.08-Ri3
Certificate ofAathorizatioh N3Z455 7T"EDITION(ZOZO)FBC NON-HVHZ EVALUATION FL10450-1113
Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020
Page 3 of 11
ONEMO I etc.
5.5 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request maybe made to the Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Clay and Concrete Tile Slate or
Asphalt (1507.3) Metal Slate-Type wood
Underlayment Shingles
(15oz2) Mechanical Adhesive- Panels Shingles Shingles Shingles Shakes(1507.9)
Attach Set (150Z4) (150Z5) (150Z7) (1507.8)
Yes Yes
LeakBarrier MS300 Yes No No No No Yes
(joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R%)5.1.1.3)
TopShield Ice&Water Yes Yes
G300 Yes No No No No Yes
(joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Yes Yes
LeakBarrier PS200HT Yes Yes Yes (No (No Yes Yes
See 5.6.1 copper copper or Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
or zinc) zinc) /R905.1.1.3) /R905.1.1.3)
Yes Yes
LeakBarrier PS200mu Yes No No (No (No Yes Yes
copper copper or Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
or zinc) zinc) /R905.1.1.3) /R905.1.1.3)
Yes Yes
Yes (No (No Yes Yes
LeakBarrier NR600 Ultra Yes Yes Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
See 5.6.1 copper copper or /R905.1.1.3) /R905.1.1.3)
or zinc) zinc)
Yes Yes
LeakBarrier S5400 Yes No No No No Yes
(joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /11905.1.1.3)
LeakBarrier EasyLay Yes Yes Yes No No Yes No No
See 5.6.2 See 5.6.2
LeakBarrier EasyLay UDL
15 or LeakBarrier EasyLay Yes Yes Yes Yes Yes Yes No No
See 5.6.2 See 5.6.2
UDL 30
Tarco 30 Yes Yes Yes Yes Yes Yes Yes Yes
See 5.6.2 See 5.6.2
Fiberglass Mineral Yes
Surfaced Roll Roofing (Valley No No No No No No No
Liner)
ASTM Organic Mineral Yes Yes Yes
Surface Tile (Valley (Cap Sheet in (Cap Sheet in No No No No No
Underlayment Liner) 2-ply system) 2-ply system)
See 5.6.1
Yes Yes
LeakBarrier EasyMop SBS No (Cap Sheet in (Cap Sheet in No No No No No
2-ply System) 2-ply system)
See 5.6.1
NEMO ETC,LLC Evaluation Report 10880.07.09-R13
c rtrf�wre ajAatharrzatran rrsZ4ss 7'"EDITION(ZOZU)FBC NON-HVHZ EVALUATION FL10450-1113
Tarco Roof Underlayment5;(254)913-7750 Revision 13:09/18/2020
Page 4 of 11
ON EMO I etc.
5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations.
TABLE ILA:ALLOWABLE UNDERLAYMENT TILE-ADHESIVE COMBINATIONS'
Underlayment Adhesive Florida Product Approval
LeakBarrier pS200"T Dupont"Tile Bond-Roof Tile Adhesive" FL22525
LeakBarrier PS200HT,LeakBarrier NR600 Ultra,ASTM
Organic Mineral Surface Tile Underlayment or LeakBarrier ICP Adhesives and Sealants"Polyset®AH-160" FL6332
EasyMop SBS
LeakBarrier PS200HT ICP Adhesives and Sealants"Polyset®RTA-1" FL6276
5.6.2 Tarco 30, EasyLay, LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30 may be used as a mechanically
attached anchor sheet followed by an asphalt-applied ASTM Organic Mineral Surface Tile Underlayment or
LeakBarrier EasyMop SBS.
5.7 Allowable Substrates:
TABLE 2' SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Primer Substrates
LeakBarrier MS300
TopShield Ice&Water G300
LeakBarrier P5200HT (Optional)
self-adhering plywood;OSB or structural concrete
LeakBarrier PS200mu ASTM D41
LeakBarrier NR600 Ultra
LeakBarrier SS400
LeakBarrier MS300
TopShield Ice&Water G300
LeakBarrier PS200HT ASTM D226 Type II felt;ASTM D4869 Type III or
self-adhering none IV felt;LeakBarrier EasyLay,LeakBarrier
LeakBarrier PS200mu EasyLay UDL 15 or LeakBarrier EasyLay UDL 30
LeakBarrier NR600 Ultra
LeakBarrier SS400
LeakBarrier MS300
TopShield Ice&Water G300
LeakBarrier PS200HT
self-adhering ASTM D41 metal(flashing metal,valley metal,etc.)
LeakBarrier PS200mu
LeakBarrier NR600 Ultra
LeakBarrier SS400
ASTM Organic Mineral Surface Tile Underlayment
hot asphalt ASTM D41 structural concrete
LeakBarrier EasyMop SBS
ASTM Organic Mineral Surface Tile Underlayment hot asphalt None ASTM D226 Type li felt,ASTM D4601 base
LeakBarrier EasyMop SBS sheet
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC,LLC Evaluation Report 10880.07.08-R33
Certificate of authorization##32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10450-R13
Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020
Page 5 of 11
"NEMO,etc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions, but—for mechanically attached underlayments or base sheets- not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table
1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical
(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-75.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction
Primer: (Optional)ASTM D41
Base Ply: (Optional)LeakBarrier PS200mu,self-adhered.
Underlayment: LeakBarrier PS200"T,self-adhered.
#2 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction
Primer: (Optional)ASTM D41
Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200mu or LeakBarrier
EasyBase,rolled into place to create continuous bond
Base Ply: (Optional) LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
#3 _Maximum Design Pressure=-217.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)ASTM D41
Base Ply: (Optional)LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
#4 All other direct-deck,adhered underlayment systems beneath the roof systems carry a Maximum Design Pressure
of-45 psf.
NEMO ETC,LLC Evaluation Report 10880.07.08-R13
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10450-R13
Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020
Page 6 of 11
(NNEMOJetc.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical
(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for enhancements.
#5 Maximum Design Pressure=-45.0 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30(48"wide rolls).
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6"o.c.at the 4-inch wide side laps and 8"o.c.at three(3)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier P5200"T,self-adhered.
#6 Maximum Design Pressure=-45.0 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30(48"wide rolls).
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6" o.c.at the 4-inch wide side laps and 8"o.c.at three(3)equally spaced,staggered center rows.
Primer: ASTM D41 primer at tin-caps.
Base Ply: (Optional)LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier NR600 Ultra,self-adhered.
#7 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 7"o.c.at the 4-inch wide side laps and 7"o.c.at three(3)equally spaced,staggered center rows.
Base Ply: (Optional) LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier PS200111 self-adhered.
#8 Maximum Design Pressure=-60.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base sheet: LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30(48"wide rolls).
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6"o.c.at the 4-inch wide side laps and 6"o.c.at four(4)equally spaced,staggered center rows.
Base Ply: (Optional) LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier PS200HT,self-adhered.
NEMO ETC,LLC Evaluation Report 10890.07.08-Ri3
Certificate ofAuthoriration##32455 fH EDITION(2020)FBC NON-HVHZ EVALUATION F1.10450-1113
Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020
Page 7 of 11
ON EM®`etc.
#9 Maximum Design Pressure=-60.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30(48"wide rolls).
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6" o.c.at the 4-inch wide side laps and 6" o.c.at four(4)equally spaced,staggered center rows.
Primer: ASTM D41 primer at tin-caps.
Base Ply: (Optional) LeakBarrier PS200Mu,self-adhered
Underlayment: LeakBarrier NR600 Ultra,self-adhered and back nailed using 12 ga.x 1.25-inch long x 3/8-inch head
diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps spaced 12"o.c.within
the self-adhering side laps.
#10 Maximum Design Pressure=-82.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8"o.c.at the 4-inch wide side laps and 8"o.c.at four(4)equally spaced,staggered center rows.
Base Ply: (Optional) LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
#11 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction,
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 4"o.c.at the 4-inch wide side laps and 4"o.c.at four(4)equally spaced,staggered center rows.
Base Ply: (Optional) LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier P5200"T,self-adhered.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Maximum
Installation Type Exposure(days)
LeakBarrier PS200"T,LeakBarrier NR600 Ultra,ASTM Organic Mineral Surface Tile Adhesive-set tile roof system 180
Underlayment or LeakBarrier EasyMop SBS or mechanically attached
LeakBarrier EasyLay Mechanically attached 180
LeakBarrier EasyLay UDL 30 Mechanically attached 180
LeakBarrier MS300,PS200111,SS400 or TopShield Ice&Water G300 Mechanically attached 30
LeakBarrier EasyLay UDL 15 Mechanically attached 30
Tarco 30 Mechanically attached 1
NEMO ETC,LLC Evaluation Report 109R0.07.09-R13
Ceroficate UfAutnorr UMB#JZ455 7—EDITION(2020)FBC NON-HVHZ EVALUATION F1.10450-1113
Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020
Page 8 of 11
ut4
NEMO I etc,
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment* Tile Profile Staging Method Maximum Slope
Flat 10-tile stack**or 6-tile stack(4 over 2) 6:12
LeakBarrier PS200"r
Lugged 6-tile stack(4 over 2) 6:12
LeakBarrier NR600 Ultra Flat or Lugged 6-tile stack(4 over 2) 6:12
ASTM Organic Mineral Surface Flat 6-tile stack(4 over 2) 5:12
Tile Underlayment or
LeakBarrier EasyMop SBS Lugged 6-tile stack(4 over 2) 6:12
Notes: *Tarco Roofing specifies a minimum 48 cure-time after the installation of self-adhering membranes and before loading of
roofing tiles.
**lf tiles are to be left in a staged condition for more than 30 days,Tarco Roofing requires tiles be staged two tiles
perpendicular to slope,four tiles on top,parallel to slope,regardless of the allowances noted above
INSTALLATION'6.
6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco Roofing installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Tarco 30:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM
D226,Type II)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.3.2 Tile Applications:
Tarco 30 is limited to use as a mechanically attached base sheet in the"TWO-PLY SYSTEM" from FRSA/TRi Florida
High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,followed by ASTM Organic Mineral Surface
Tile Underlayment or LeakBarrier EasyMop SBS applied in hot asphalt, or other FBC Approved hot-asphalt applied
cap sheet. Refer to FRSA/TRI,Sixth Edition,Appendix A,Table 1 for attachment requirements.
6.4 LeakBarrier EasyLay:
6.4.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached Underlayment (ASTM
D226,Type 11)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions_
NEMO ETC,LLC Evaluation Report 10880.07.084i13
Certificate of Authorization#t32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10450-R13
Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020
Page 9 of 11
NNEMO I etc..
6.4.2 Tile Applications:
LeakBarrier EasyLay is limited to use as a mechanically attached base sheet in the"TWO-PLY SYSTEM"from FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition
• When LeakBarrier EasyLay is followed by ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier
EasyMop SBS applied in hot asphalt,or other FBC Approved hot-asphalt applied cap sheet,refer to FRSA/TRI,
Sixth Edition,Appendix A,Table 1 for attachment requirements.
• When LeakBarrier EasyLay is followed by LeakBarrier PS200"T, refer to Section 5.8.3.2 herein for attachment
requirements.
6.5 LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30.
6.5.1 Non-Tile Applications:
Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception),
1507.1.1.1(3,Exception)or 1507.1.1.1(5)or FBC Residential R905.1.1.1(2,Exception),R905.1.1.1(3,Exception)or
R905.1.1.1(5) for the type of prepared roof covering to be installed,and the manufacturer's installation instructions.
FBC requirements take precedence over the manufacturer's installation instructions.
6.5.2 Tile Applications:
LeakBarrier EasyLay UDL 15 and LeakBarrier EasyLay UDL 30 are limited to use as a mechanically attached base sheet
in the"TWO-PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth
Edition, followed by LeakBarrier PS2001TI self-adhered. Refer to Section 5.8.3.2 herein for attachment
requirements.
6.6 LeakBarrier" MS300, LeakBarrier® PS2001u,LeakBarrler®SS400 Ice and Water Armor or TopShield Ice&Water
G300:
6.6.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to
be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt or ASTM D4869,Type III or IV
felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.6.2 Multi-Ply Underlayment Systems:
LeakBarrier®SS400 Ice and Water Armor followed by LeakBarrier®SS400 Ice and Water Armor is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material.
This is not a requirement, but is allowable if a multi-ply underlayment system is desired.
6.7 LeakBarrier®PS200HT or LeakBarrier®NR600 Ultra:
6.7.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to
be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt or ASTM D4869,Type III or IV
felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.7.2 Tile Applications:
Shall be installed in compliance with requirements for a Self-Adhered Membrane in the FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth Edition,and the manufacturer's installation instructions.
Refer to Section 5.8.2 for attachment Iimitation5.
Refer to Table 4 for tile staging limitations.
NEMO ETC,LLC Evaluation Report 10880.07.08-1113
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10450-1113
Tarco Roof Underlayments;(254)913-77SO Revision 13:09/18/2020
Page 10of11
(NNEMOjetc.
6.9 ASTM Organic Mineral Surface Tile Underlayment and LeakBarrieem EasyMop SBS:
6.8.1 Tile Applications:
ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier'" EasyMop SBS are limited to use as the Hot
Asphalt applied "Cap Sheet" in the "TWO-PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Clay Roof
Tile Installation Manual,Sixth Edition.
Refer to Section 5.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
6.9 Fiberglass Mineral Surface Roll Roofing and ASTM Organic Mineral Surface Tile Underlayment:
6.9.1 Fiberglass Mineral Surface Roll Roofing and ASTM Organic Mineral Surface Tile Underlayment are limited to use as
a valley liner in accordance with FBC 1507.2.9.2 or FBC Residential R905.2.8.2. Installation shall be in accordance
with the manufacturer's instructions before applying shingles.
REQUIREMENTS.7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS.
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. --QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409; Karen.buchmann@ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 10880.07.08-R13
Certificate ofAuthorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10450-1113
Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020
Page 11 of 11