Loading...
HomeMy WebLinkAboutAPPROVED #30 1/16/2021 Florida Building Code Online Business & ProfessionalRegulation BCIS Home ( Log In 1 User Registration j Hot Topics I Submit Surcharge { Stats&Facts t Publications f contact Us ( BCIS Site Map Links j Search 9 fly 4w&rProduct Approval USER:Public User CR'l Product Approval Menu>Product or Application Search>Application List>Application Detail a FL# FL10450-1113 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Tarco Roofing Address/Phone/Email One Information Way Suite 225 Little Rock,AR 72202 (254)913-7750 smohseen@tarcoroofing.com Authorized Signature Shaik Mohseen smohseen@tarcoroofing.com Technical Representative Shaik Mohseen Address/Phone/Email 2403 Taylors Valley Road Belton,TX 76513 (254)913-7750 smohseen@tarcoroofing.com Quality Assurance Representative Shaik Mohseen Address/Phone/Email 2403 Taylors Valley Road Belton,TX 78717 (254)939-3775 Ext210 smohseen@tarcoroofing.com Category Roofing Subcategory Underiayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/26/2022 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10450 R13 COI 2020 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D3909 2014 ASTM D4533 2015 ASTM 04798 ZU11 ASTM D4869 2016 ASTM D5035 2011 ASTM 136164 2011 ASTM D6380 2013 FM 4474 2011 www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqudsDrIH614890v%2fSoZ)1/grzyCLUr7kavhktJH3XFXTeA%3d%3d 112 1/1 612 02 1 Florida Building Code Online FRSA/TRI Sixth Edition 2018 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/19/2020 Date Validated 09126/2020 Date Pending FBC Approval 10/02/2020 Date Approved 12/15/2020 Summary of Products FL# Model,Number or Name Description 10450.1 Tarco Roof Underlayments Roof underlayments for use in prepared roof assemblies 7 Limits of Use Installation Instructions Approved for use in HVH2:No FL10450 R13 II 2020 09 18 FINAL ER TARCO UNDERLAYMENTS FL10450- Approved for use outside HVH2:Yes Rl .pdf Impact Resistant:N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-217.5 Created by Independent Third Party:Yes Other: 1.)The design pressure herein pertains to Evaluation Reports one particular bonded underlayment application for FL10450 R13 AE 2020 09 18 FINAL ER TARCO UNDERLAYMENTS FL10450- use beneath adhesive-set tile systems.Refer to ER R13.pdf Section 5.6.2 for details,and other bonded Created by Independent Third Party:Yes underlayment systems.2.)Refer to ER Section 5 for Limits of Use. %ae3c tkexY Contact Us;:2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes, effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: El Credit Card Safe IIII I! www.floridabuilding.org/pr/pr_app_otl.aspx?param=wGEVXQwtDqudsDrlH6[4890v%2fSoZjVgrzyCLUr7kavhktJH3XFXTeA%3d%3d 2/2 NEMOI etc. Certificate of Authorization#32455 U( 353 Christian Street, Unit 413 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION .O. Tarco Roofing Evaluation Report 10880.07.08-R13 One Information Way,Suite 225 FL10450-R13 Little Rock,AR 72202 Date of Issuance:07/11/2008 (254)913-77SO Revision 13:09/18/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7th Edition(2020) Florida Building Code sections noted herein. DESCRIPTION: Tarco Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "MEMO(etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 11. Prepared by: - t c :L;; Robert J.M.Nieminen,P.E. ., r'-`,. The facsimile seal appearing was authorized by Robert Jc 'rr.'. Florida Registration No.59166,Florida OCA ANE1983 s r r�,',.a Nieminen,P.E.on 09/18/2020. This does not serve as an - electronically signed document- CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 2- Robert Nieminen,P-E-does not k---nor w;lt a�qu;��,a financial interest in any company manufacturing or aistnbuting prooucis for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 02018,NEMO ETC,LLC ONEMO I etc. ROOFING COMPONENT EVALUATION SCOPE:1. Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Tarco Roof Underlayments,as produced by Tarco Roofing, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1507.1.1/R905.1.1 Material standard ASTM D226 2009 1507.1.1/R905.1.1 Material standard ASTM D4869 2016 1507.1.1,1507.2.4,1507.2.9.2/R905.1.1, Material standard ASTM D1970 2015 R905.2.8.2 1507.2.9.2,1507.6.5/R905.2.8.2,R905.5.4 Material standard ASTM D3909 2014 1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tear strength ASTM D4533 2015 R905.1.1.1(2&3,Exception),R905.1.1.1(5) 1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tensile strength ASTM D5035 2011 R905.1.1.1(2&3,Exception),R905.1.1.1(5) 1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1507.2.9.2,1507.6.5/R905.2.8.2,R905.5.4 Material standard ASTM D6380 2013 1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018 1507.11.2/R905.11.2 Material standard ASTM D6164 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 1, REFERENCES' Entity Examination Reference Date Entity Examination Reference Date ERD(TST6049) D4869,D5035 C30280.12.09 12/11/2009 ERD(TST6049) ASTM D4533 CTR-SC16080.10.17 10/25/2017 ERD(TST6049) FRSA/TRI T33190.08.10 08/06/2010 PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003 ERD(TST6049) ASTM D1970 T32S30.08.10 08/17/2010 PRI(TST5878) ASTM D1970 BRY-017-02-01 08/11/2003 ERD(TST6049) ASTM D4798 C30280.12.09-R2 08/20/2010 PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004 ERD(TST6049) FM 4474 T37610.07.11 06/29/2011 PRI(TST5878) ASTM D226 TOT-015-02-02 05/24f2004 ERD(TST6049) ASTM D3909 T40780.04.12 04/06/2012 PRI(TST5878) ASTM D4869 TOT-009-02-01 09/14/2004 ERD(TST6049) ASTM D6380 T40790.04.12 04/06/2012 PRI(TST5878) ASTM D4869 TOT-009-02-02 09/14/2004 ERD(TST6049) ASTM D6164 T35410.04.12 04/18/2012 PRI(TST5878) ASTM D226 TOT-041-02-01 05/24/2006 ERD(TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013 M-D(CER1592) FBC HVHZ 16-1116.09 01/12/2017 ERD(TST6049) FRSA/TRI T43930.09.13-R2 09/11/2013 NEMO(TST6049) FRSA/TRI TAR-SC8020.06.18 06/05/2018 ERD(TST6049) D226&D4869 SC4950.02.14-R2 06/25/2014 NEMO(TST6049) Tensile adhesion 4S-TAR-18-002.07.18-1 07/20/2018 ERD(TST5049) ASTM D1970 TAR-SC9480.15 07/02/2015 NEMO(TST6049) FRSA/TRI 4S-TAR-18-002.07.18-2 07/20/2018 ERD(TST6049) FM 4474 TAR-SC8020.14 12/03/2015 NEMO(TST6049) TAS 117(B) 4i-CTR-I9-SSCRT-01.A 04/10/2019 ERD(TST6049) FM 4474 TAR-SC5670.03.16 03/21/2016 NEMO(TST6049) ASTM D4798 4j-TAR-I9-SSUDL.01.A 08/27/2019 ERD(TST6049) FM 4474 T6460.06.07-R2 05/26/2017 Tarco Roofing Adhesive comp Affidavit 12/15/2015 ERD(TST6049) A5TM DZZ6 03/17/ZU17 TarCO"onng FBC CroSS-List Listing Agreement 01/20/2020 ERD(TST6049) FBC 1507.1A TAR-SC16115.17 10/02/2017 UL,LLC.(QUA9625) QA Service Confirm(IND) 11/22/2016 ERD(TST6049) FRSA/TRI TAR-SC16115.17 10/02/2017 UL,LLC.(QUA9625) QA Service Confirm(PA) 06/28/2017 UL,LLC.(QUA9625) QA Service Confirm(TX) 08/13/2018 NEMO ETC,LLC Evaluation Report 10880.07.08-1113 Certificate of Authorization F/3Z455 7'"EDITION(ZUZO)FBC NON-HVHZ EVALUATION FL10450-R13 Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020 Page 2 of 11 NNEM10 I etc. 4. PROULICT r • Product Material Standard Plant(s) Description 4.1 LeakBarrier MS300Ice and ASTM D1970 Belton,TX self-adhering,glass mat reinforced,mineral Water Armor Greencastle,PA surfaced,SBS modified roof underlayment 4.2 TopShield Ice&Water G300 ASTM D1970 Belton,TX self-adhering,glass mat reinforced,mineral Greencastle,PA surfaced,SBS modified roof underlayment 4.3 LeakBarrier PS200"T Ice and ASTM D1970 and Belton,TX self-adhering,glass mat reinforced,fabric Water Armor FRSA/TRI 09-18 Greencastle,PA surfaced,SBS modified roof underlayment 4.4 LeakBarrier°PS200mu Ice ASTM D1970 Belton,TX self-adhering,glass mat reinforced,smooth and Water Armor Greencastle,PA poly film surfaced,SBS modified roof underlayment 4.5 LeakBarrier NR600 Ultra Ice ASTM D1970 and Greencastle,PA self-adhering,polyester-fabric surfaced,SBS and Water Armor FRSA/TRI 09-18 modified roof underlayment 4.6 LeakBarrier®SS400 Ice and ASTM D1970 Belton,TX self-adhering,fiberglass reinforced,smooth Water Armor Greencastle,PA surfaced modified underlayment 4.7 Tarco 30 ASTM D226,Type II Belton,TX asphalt-saturated organic felt Greencastle,PA 4.8 LeakBarrier EasyLay ASTM D226,Type it Belton,TX asphalt-coated polyester fabric roof Greencastle,PA underlayment 4.9 Fiberglass Mineral Surfaced ASTM D3909 Greencastle,PA glass-fiber-reinforced,asphalt-coated,granule Roll Roofing surfaced underlayment used as a valley liner 4.10 ASTM Organic Mineral ASTM D6380,Class M Greencastle,PA asphalt-saturated organic roll roofing sheet Surface Tile Underlayment 4.11 LeakBarrier EasyMop'"SBS FRSA/TRI April 09-18 Greencastle,PA polyester reinforced,SBS modified bitumen roofing underlayment 4.12 LeakBarrier EasyLay UDL 1507.1.1.1(2&3, Gujarat,India woven-polymeric scrim with a textured fabric 15 Exception),1507.1.1.1(5)/ on the top surface R905.1.1.1(2&3, Exception),R905.1.1.1(5) 4.13 LeakBarrier EasyLay UDL 1507.1.1.1(2&3, Gujarat,India woven-polymeric scrim with a textured fabric 30 Exception),1507.1.1.1(5)/ on the top surface R905.1.1.1(2&3, Exception),R905.1.1.1(5) 15. • 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. NEMO ETC,LLC Evaluation Report 10880.07.08-Ri3 Certificate ofAathorizatioh N3Z455 7T"EDITION(ZOZO)FBC NON-HVHZ EVALUATION FL10450-1113 Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020 Page 3 of 11 ONEMO I etc. 5.5 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request maybe made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Clay and Concrete Tile Slate or Asphalt (1507.3) Metal Slate-Type wood Underlayment Shingles (15oz2) Mechanical Adhesive- Panels Shingles Shingles Shingles Shakes(1507.9) Attach Set (150Z4) (150Z5) (150Z7) (1507.8) Yes Yes LeakBarrier MS300 Yes No No No No Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3 /R905.1.1.3) /R%)5.1.1.3) TopShield Ice&Water Yes Yes G300 Yes No No No No Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3 /R905.1.1.3) /R905.1.1.3) Yes Yes LeakBarrier PS200HT Yes Yes Yes (No (No Yes Yes See 5.6.1 copper copper or Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3 or zinc) zinc) /R905.1.1.3) /R905.1.1.3) Yes Yes LeakBarrier PS200mu Yes No No (No (No Yes Yes copper copper or Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3 or zinc) zinc) /R905.1.1.3) /R905.1.1.3) Yes Yes Yes (No (No Yes Yes LeakBarrier NR600 Ultra Yes Yes Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3 See 5.6.1 copper copper or /R905.1.1.3) /R905.1.1.3) or zinc) zinc) Yes Yes LeakBarrier S5400 Yes No No No No Yes (joint strips,1507.1.1.3 (joint strips,1507.1.1.3 /R905.1.1.3) /11905.1.1.3) LeakBarrier EasyLay Yes Yes Yes No No Yes No No See 5.6.2 See 5.6.2 LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay Yes Yes Yes Yes Yes Yes No No See 5.6.2 See 5.6.2 UDL 30 Tarco 30 Yes Yes Yes Yes Yes Yes Yes Yes See 5.6.2 See 5.6.2 Fiberglass Mineral Yes Surfaced Roll Roofing (Valley No No No No No No No Liner) ASTM Organic Mineral Yes Yes Yes Surface Tile (Valley (Cap Sheet in (Cap Sheet in No No No No No Underlayment Liner) 2-ply system) 2-ply system) See 5.6.1 Yes Yes LeakBarrier EasyMop SBS No (Cap Sheet in (Cap Sheet in No No No No No 2-ply System) 2-ply system) See 5.6.1 NEMO ETC,LLC Evaluation Report 10880.07.09-R13 c rtrf�wre ajAatharrzatran rrsZ4ss 7'"EDITION(ZOZU)FBC NON-HVHZ EVALUATION FL10450-1113 Tarco Roof Underlayment5;(254)913-7750 Revision 13:09/18/2020 Page 4 of 11 ON EMO I etc. 5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations. TABLE ILA:ALLOWABLE UNDERLAYMENT TILE-ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval LeakBarrier pS200"T Dupont"Tile Bond-Roof Tile Adhesive" FL22525 LeakBarrier PS200HT,LeakBarrier NR600 Ultra,ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier ICP Adhesives and Sealants"Polyset®AH-160" FL6332 EasyMop SBS LeakBarrier PS200HT ICP Adhesives and Sealants"Polyset®RTA-1" FL6276 5.6.2 Tarco 30, EasyLay, LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30 may be used as a mechanically attached anchor sheet followed by an asphalt-applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS. 5.7 Allowable Substrates: TABLE 2' SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Primer Substrates LeakBarrier MS300 TopShield Ice&Water G300 LeakBarrier P5200HT (Optional) self-adhering plywood;OSB or structural concrete LeakBarrier PS200mu ASTM D41 LeakBarrier NR600 Ultra LeakBarrier SS400 LeakBarrier MS300 TopShield Ice&Water G300 LeakBarrier PS200HT ASTM D226 Type II felt;ASTM D4869 Type III or self-adhering none IV felt;LeakBarrier EasyLay,LeakBarrier LeakBarrier PS200mu EasyLay UDL 15 or LeakBarrier EasyLay UDL 30 LeakBarrier NR600 Ultra LeakBarrier SS400 LeakBarrier MS300 TopShield Ice&Water G300 LeakBarrier PS200HT self-adhering ASTM D41 metal(flashing metal,valley metal,etc.) LeakBarrier PS200mu LeakBarrier NR600 Ultra LeakBarrier SS400 ASTM Organic Mineral Surface Tile Underlayment hot asphalt ASTM D41 structural concrete LeakBarrier EasyMop SBS ASTM Organic Mineral Surface Tile Underlayment hot asphalt None ASTM D226 Type li felt,ASTM D4601 base LeakBarrier EasyMop SBS sheet 'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. MEMO ETC,LLC Evaluation Report 10880.07.08-R33 Certificate of authorization##32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10450-R13 Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020 Page 5 of 11 "NEMO,etc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with the manufacturer's installation instructions, but—for mechanically attached underlayments or base sheets- not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but—for mechanically attached base sheets-not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein(for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure=-75.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: (Optional)ASTM D41 Base Ply: (Optional)LeakBarrier PS200mu,self-adhered. Underlayment: LeakBarrier PS200"T,self-adhered. #2 Maximum Design Pressure=-120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: (Optional)ASTM D41 Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200mu or LeakBarrier EasyBase,rolled into place to create continuous bond Base Ply: (Optional) LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. #3 _Maximum Design Pressure=-217.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM D41 Base Ply: (Optional)LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. #4 All other direct-deck,adhered underlayment systems beneath the roof systems carry a Maximum Design Pressure of-45 psf. NEMO ETC,LLC Evaluation Report 10880.07.08-R13 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10450-R13 Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020 Page 6 of 11 (NNEMOJetc. 5.8.3.2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for enhancements. #5 Maximum Design Pressure=-45.0 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30(48"wide rolls). Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6"o.c.at the 4-inch wide side laps and 8"o.c.at three(3)equally spaced,staggered center rows. Base Ply: (Optional)LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier P5200"T,self-adhered. #6 Maximum Design Pressure=-45.0 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30(48"wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c.at the 4-inch wide side laps and 8"o.c.at three(3)equally spaced,staggered center rows. Primer: ASTM D41 primer at tin-caps. Base Ply: (Optional)LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier NR600 Ultra,self-adhered. #7 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 7"o.c.at the 4-inch wide side laps and 7"o.c.at three(3)equally spaced,staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200111 self-adhered. #8 Maximum Design Pressure=-60.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base sheet: LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30(48"wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6"o.c.at the 4-inch wide side laps and 6"o.c.at four(4)equally spaced,staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200HT,self-adhered. NEMO ETC,LLC Evaluation Report 10890.07.08-Ri3 Certificate ofAuthoriration##32455 fH EDITION(2020)FBC NON-HVHZ EVALUATION F1.10450-1113 Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020 Page 7 of 11 ON EM®`etc. #9 Maximum Design Pressure=-60.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30(48"wide rolls). Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c.at the 4-inch wide side laps and 6" o.c.at four(4)equally spaced,staggered center rows. Primer: ASTM D41 primer at tin-caps. Base Ply: (Optional) LeakBarrier PS200Mu,self-adhered Underlayment: LeakBarrier NR600 Ultra,self-adhered and back nailed using 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps spaced 12"o.c.within the self-adhering side laps. #10 Maximum Design Pressure=-82.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: Simplex MAXX Cap Fasteners Spacing: 8"o.c.at the 4-inch wide side laps and 8"o.c.at four(4)equally spaced,staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier PS200"T,self-adhered. #11 Maximum Design Pressure=-120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 4"o.c.at the 4-inch wide side laps and 4"o.c.at four(4)equally spaced,staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu,self-adhered Underlayment: LeakBarrier P5200"T,self-adhered. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Maximum Installation Type Exposure(days) LeakBarrier PS200"T,LeakBarrier NR600 Ultra,ASTM Organic Mineral Surface Tile Adhesive-set tile roof system 180 Underlayment or LeakBarrier EasyMop SBS or mechanically attached LeakBarrier EasyLay Mechanically attached 180 LeakBarrier EasyLay UDL 30 Mechanically attached 180 LeakBarrier MS300,PS200111,SS400 or TopShield Ice&Water G300 Mechanically attached 30 LeakBarrier EasyLay UDL 15 Mechanically attached 30 Tarco 30 Mechanically attached 1 NEMO ETC,LLC Evaluation Report 109R0.07.09-R13 Ceroficate UfAutnorr UMB#JZ455 7—EDITION(2020)FBC NON-HVHZ EVALUATION F1.10450-1113 Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020 Page 8 of 11 ut4 NEMO I etc, 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment* Tile Profile Staging Method Maximum Slope Flat 10-tile stack**or 6-tile stack(4 over 2) 6:12 LeakBarrier PS200"r Lugged 6-tile stack(4 over 2) 6:12 LeakBarrier NR600 Ultra Flat or Lugged 6-tile stack(4 over 2) 6:12 ASTM Organic Mineral Surface Flat 6-tile stack(4 over 2) 5:12 Tile Underlayment or LeakBarrier EasyMop SBS Lugged 6-tile stack(4 over 2) 6:12 Notes: *Tarco Roofing specifies a minimum 48 cure-time after the installation of self-adhering membranes and before loading of roofing tiles. **lf tiles are to be left in a staged condition for more than 30 days,Tarco Roofing requires tiles be staged two tiles perpendicular to slope,four tiles on top,parallel to slope,regardless of the allowances noted above INSTALLATION'6. 6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco Roofing installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Tarco 30: 6.3.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226,Type II)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.3.2 Tile Applications: Tarco 30 is limited to use as a mechanically attached base sheet in the"TWO-PLY SYSTEM" from FRSA/TRi Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,followed by ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS applied in hot asphalt, or other FBC Approved hot-asphalt applied cap sheet. Refer to FRSA/TRI,Sixth Edition,Appendix A,Table 1 for attachment requirements. 6.4 LeakBarrier EasyLay: 6.4.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached Underlayment (ASTM D226,Type 11)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions_ NEMO ETC,LLC Evaluation Report 10880.07.084i13 Certificate of Authorization#t32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10450-R13 Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020 Page 9 of 11 NNEMO I etc.. 6.4.2 Tile Applications: LeakBarrier EasyLay is limited to use as a mechanically attached base sheet in the"TWO-PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition • When LeakBarrier EasyLay is followed by ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS applied in hot asphalt,or other FBC Approved hot-asphalt applied cap sheet,refer to FRSA/TRI, Sixth Edition,Appendix A,Table 1 for attachment requirements. • When LeakBarrier EasyLay is followed by LeakBarrier PS200"T, refer to Section 5.8.3.2 herein for attachment requirements. 6.5 LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay UDL 30. 6.5.1 Non-Tile Applications: Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3,Exception)or 1507.1.1.1(5)or FBC Residential R905.1.1.1(2,Exception),R905.1.1.1(3,Exception)or R905.1.1.1(5) for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5.2 Tile Applications: LeakBarrier EasyLay UDL 15 and LeakBarrier EasyLay UDL 30 are limited to use as a mechanically attached base sheet in the"TWO-PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition, followed by LeakBarrier PS2001TI self-adhered. Refer to Section 5.8.3.2 herein for attachment requirements. 6.6 LeakBarrier" MS300, LeakBarrier® PS2001u,LeakBarrler®SS400 Ice and Water Armor or TopShield Ice&Water G300: 6.6.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt or ASTM D4869,Type III or IV felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.6.2 Multi-Ply Underlayment Systems: LeakBarrier®SS400 Ice and Water Armor followed by LeakBarrier®SS400 Ice and Water Armor is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a multi-ply underlayment system is desired. 6.7 LeakBarrier®PS200HT or LeakBarrier®NR600 Ultra: 6.7.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt or ASTM D4869,Type III or IV felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.7.2 Tile Applications: Shall be installed in compliance with requirements for a Self-Adhered Membrane in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,and the manufacturer's installation instructions. Refer to Section 5.8.2 for attachment Iimitation5. Refer to Table 4 for tile staging limitations. NEMO ETC,LLC Evaluation Report 10880.07.08-1113 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10450-1113 Tarco Roof Underlayments;(254)913-77SO Revision 13:09/18/2020 Page 10of11 (NNEMOjetc. 6.9 ASTM Organic Mineral Surface Tile Underlayment and LeakBarrieem EasyMop SBS: 6.8.1 Tile Applications: ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier'" EasyMop SBS are limited to use as the Hot Asphalt applied "Cap Sheet" in the "TWO-PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. Refer to Section 5.8.2 for attachment limitations. Refer to Table 4 for tile staging limitations. 6.9 Fiberglass Mineral Surface Roll Roofing and ASTM Organic Mineral Surface Tile Underlayment: 6.9.1 Fiberglass Mineral Surface Roll Roofing and ASTM Organic Mineral Surface Tile Underlayment are limited to use as a valley liner in accordance with FBC 1507.2.9.2 or FBC Residential R905.2.8.2. Installation shall be in accordance with the manufacturer's instructions before applying shingles. REQUIREMENTS.7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS. Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. --QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409; Karen.buchmann@ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 10880.07.08-R13 Certificate ofAuthorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10450-1113 Tarco Roof Underlayments;(254)913-7750 Revision 13:09/18/2020 Page 11 of 11