Loading...
HomeMy WebLinkAboutProject InformationC T. LUCI E WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based,on Section 1525 of the Florida Building Code -!Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1 2 3,4,6,6;7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D Concrete or Clay Tile A; B, D, E Metal Roofs A, B, D 1,23,4,5,67 Wood Shingles and Shakes A, B, D Other As Applicable 1,2 Q.-A 5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description . Specific System Limitations General Limitations -.Applicable Detail Drawings 3. Design Calculations pe"r Chapter 16, or if applicable, RAS 127. or RAS 1281 4. ' Other Component -of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. 1 Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE WORKS Section A (General Information) Master Permit No. Process No. 'Contractors Name: _I r� V ro L -ey n 0,S' O License # C O C l 3 3z S 11 Job Address ,� 0 8 �o r K C' , Fo r-4- P,-Cr c2 , F C- 3 �f 9 F ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles 8Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering .ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 3 SO O Total (SF) 3 V Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. S% LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows 0. 0,00 Zone 1:—" oc @ Lap, # Rows "oc Zone 2:_.._." oc @ Lap, #. Rows @. ".ac Zone 3: oc @ Lap, # Rows ac Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: _ Deck: Type , Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet FastenerMonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer:. Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Number of Fasteners Per Insulation Board:: Zone 1': Zone 1: Zone 2: Zone 3:_ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, "Flashing,:'Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ST. LUCIE WORKS Section D (Steep Slope Roof System) Slri,r•�1�e,S\c� r»�+} Roof System Manufacturer: Z 0 r-,A Us , QS L tJ SG c�,M A T.nC.• C�a..a.�A, Notice of Acceptance Number: (-3 6 3 (10 S(g Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): one one —: SrTzo Deck Type: Sovf tR flow Pam- (on Type Underlay rent: T+� 64k S and - 9- $ R S %� 5�: ck� Roof Slope: 2•S 12 Insulation: Fire Barrier: Ridge Ventilation? Fastener Type & Spading: $'O„'�o' o ecu. 0 %+q o c OL+ %eS S O+ hank hLf Adhesive Type: Type Cap Sheet: Mean Roof Height: Roof Covering: 0.0 Type & Size Drip -z • t "'A .3 -Z Edge: b.,ll n o Ssz