HomeMy WebLinkAboutProduct Approval (2) S Pr
• s
BCIS Home Login ' User Registration Hot Topics Submit Surcharge Stats&Facts ,Publications fi Contact Us BCIS Site Map V Links I Search i
bolida
d - r
itQ
Product Approval
USER:Public:User
Product Aooroval'Menu>Application Detail
FL# FL2569-R21
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Soprema,Inc.(Canada)
Address/Phone/Email 1640 rue.Haggarty
Drummondville,NO*US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@so prema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00006
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888), 11-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M.Nierninen
Evaluation Report
Florida License PE-59166
Quality'Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W.Knezevich,PE
4 d Validation Checklist-Hardcopy'Received
Certificate of Independence FL2569 R21 COI 2020 01 COL NIEMINEN pdf
3
s
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D4798 2011 j
ASTM D6163 2015
FM 4474 2011
i
FRSA/TRI Sixth Edition 2018 1
UL1897 2015 ?
k
f
1
Equivalence of Product Standards
Certified By.
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/16/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Date Revised 04/19/2021
Summary of Products
del,Number or Name Descri tion
2569.1 Soprema Roof Underlayments Self adhering roof underlayments
'Limits of Use Installation Instructions
Approved for use In HVHZ:No FL2569 R21 II 2020 12 16 FINAL ER SOPREMA FL2569-
Approved for use outside HVHZ:Yes R21.pdf
Impact Resistant:N/A Verified By: Robert Nieminen,P.E.PE-59166
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes
Other:1.)Refer to ER Section 5 for Limits of Use.2.)The Evaluation Reports
design pressure noted herein pertains to underlayment systems FL2569 R21 AE 2020 12 16 FINAL ER SOPREMA FL2569-
used beneath adhesive-set the systems. Refer to ER Section R21.Ddf
5.8.3 for details. Created by Independent Third Party:Yes
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your.e-mail.address released In response to a public-retards request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1995.*Pursuant to Section 455.275(1),
Florida Statutes,effective'October 1,2012,licensees licensed under Chapter 455,F.S.must.provide the Department with an email address if they have one,The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,ES,please click here.
Product Approval Accepts:
® heck
Credit Card
Safe
NEW etc.
Certii lcate of Authorization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(208)262-9245
ENGINEER EVALUATE TEST CONSULT
.O.
Soprema,Inca Evaluation Report S18010.06.09-1119
1640 rue Haggerty FL2569-1121
Drummbndvllle,.QudbeGJ2C 5P8 Canada ' Date of Issuance:46/1512009
(819)478-2400 Revision 19'-12/16/2020
SCOPE:
This-Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been,reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code. The,product described herein has been evaluated for
compliance with the 7th Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Soprem&,Roof Underlayments,:
LABELING:•Labeling,shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED,COMPUANCE:This Evaluation Report is valid until such time as the named product(s)changesi the referenced
Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval.Number(FL#)-preceded by the words"NEMOI etc. Evaluated"maybe
displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its
entirety.
INSPECTION:Upon request,a copy-of this,entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for'inspection at the job site at the request.of the Building Official.
This Evaluation Report consists of pages'l through 9.
Prepared by:
Robert J:M:Nieminen,P.E. ='a�a n ,a+,ag• The facsimile-seal appearing was authorized by Robert
,S�iD�� Nieminen,P.E.on 12/16/2020.This does not serve as
FlondaRegistrationNo.59166,FloridaDCAANE1983 y ��n�.°«' an electronically signed document.
CERTIFICATION bF INDEPENDENCE:
1.. 'NEMO.ETC,LLC does not have,nor does it intend to acquire or will it acquire;a financial interest in,any comps ly'manufacturing,or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert,Nieminen;P.E.does not have nor will acquire,a financial interest in any'company manufacturingor distributing products for
which the evaluation reports are being issued.
4. Rob6tvNieminen,P.E.does not have,nor will acquire,a financial interest in any.other entity involved in the approval processof the
product.
5. This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained i
specifically for that purpose.
02019 NEMO ETC,LLC
i
t
's
3
NEMO 1'etC.
ROOFING COMPONENT EVALUATION: Ur .
e•
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Soprema Roof Underlayments,as produced by Soprema,have demonstrated compliance
with the following sections of the 7th.Edition(2020)Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use
set forth herein.
STANDARDS:
Section Pro a Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/R905.1:1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6163 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
Enti Examination Reference Date
ERD(TST6049) Wind Resistance 2778.07.05 .07115/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.10-1-111 04/07/2010,
ERD(TST6049) FRSA/TRI 04712(OH) S11156.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) S37210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/16/2014
ERE(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH), S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04:14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-91 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 45-SOPC-18-002:05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p=DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(TST6049) Peel,adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-20-SSUDL-01 12/16/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01, 12/03/2013
Soprema,Inc..(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,.LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
NEMO ETC,LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization&32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/1S/2020
Page 2 of 9
f
ONEMOjeft.
4. PRODUCT DESCRIPTION:
'Material
Product, Plarlt(sp Description
Standard
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
FRSA/TRI 49-18 surfaced,SBS modified bitumen roof
underlayment
4.2 Tri-BuiltS/A HTTU ASTM D1970 and Gulfport,Ms self-adhering,non-woven polyester fabric
Underlayment FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.3 Lastobond Shield ASTM 01970 Drummondville,QC self-adhering,woven polyethylene surfaced,.SBS
modified bitumen.roof underlayment available in
two widths;-36 and 45'inch
4.4 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering;woven polyethylene surfaced,SBS
40 modified bitumen foof underlayment
4.5. Lastobond Shield HT ASTM,D1970. Drummondville,QC' self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.6 Lastobond Pro HT-N ASTM 01970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
mollified bitumen roof underlayment available in
two widths,36and 45-inch
4.7 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.8 EnviroShield ASTM D1910 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.9 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
'Wadsworth,OR surfaced,SBS modified bitumen roof
underlayment
4.10 Lastobond Eaves ASTM D1970 Gulfport,MS self adhering,glass-mat reinforced,sand-
Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.11 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,.glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.12 'Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,.film-
HT Wadsworth,OH surfaced,SBS modified.bitumen roof
underlayment
4:13 Tri-Built Smooth HTS/A ASTM D1970 Gulfport,M5 self:adherin&glass-mat reinforced,film-
Underlayment Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.14 PrimeSource Grip-Rite ASTM Di970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth;OH surfaced,SB'S modified bitumen roof
underlayment
4.15 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,.glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
- d I
Q-16: TTRI-SU1LTSand-RSA ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Shingle Underlayment Gulfport,MS surfaced,SB5modified bitumen roof j
Wadsworth,OH underlayment l
NEMO ETC LLC
Evaluation Report S3f3030.06,09-Ri9
Cenificote ofAuthorization A32455 7TM EDITION(2020)FSC NON-HVHZ EVALUATION FL2569-R21 �
Soprema Roof Underlayments Revision 19:12/15/2020 €
Page 3 of 9
;I
ONEMO.Jetc.
Material
Product Standard ' Plant(s) Description ,
4.17 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Eave&Valley Protector Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.18 SRSTopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.19 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS.modified bitumen roof
Wadsworth,OH I underlayment
4.20 Colphene FR GR ASTM D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
5.1 This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in anyway,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction..
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC,approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1:'ROOF,COVER OPTIONS
FBCSection: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&1507.9
Clay and Concrete Tile. Metal Slate or
Asphalt Wood Shakes or
Underlayment ', Mechanical.: -Adhesive- Slate-Type
Shingles Attach Set Panels Shingles Shingles Shingles
Lastobond TU HT,Tri-Built S/A HT TU Yes yes
Underlayment Yes Yes tee 5.6.1 Yes Yes Yes Qoint strips,15DZL1.3/
_ 11905.1.1.3)
Lastobond Shield,Pro,HT-N,RESISTO SA Yes
SMOOTH PLY40 Yes No No No No Yes Uoint strips,1507.1.1.3/
R905.L1.3)
Yes
Lastobond Shield HT,Pro HT-S Yes No No Yes Yes Yes Goint strips,sso7.1.1.3/
R905.L1.3)
Yes
Enviroshield Yes No No Yes Yes Yes (joint stripe,1507.1.1.3/
R905.1.1.3)
Lastobond.Eaves Protection Sheet, Yes
Lastobond195: Yes No No No No Yes (jointstrips,1507.L1.3/
-- R905.1.L3)
MEMO ETC,LLC Evaluation Report S18010.06.09419
Cerocate of Authorization#32455 7-EDITION(2020)FBC NON4IV`HZ EVALUATION FL2569•RZl
Soprema Roof Underiayments Revision 19:W15%2020
Page 4 of 9
ONEMOjetc.
ABLE 1 A6&t,COVER OPTIONS '
FBCSection: 1507.2 150Z3 1507.4k 15075 1507.7, 1507.8&1507.R
Cla
y-y and Concrete Tile, Metal-
'. Slate or
Underla merit Asphalt Wood Shakes or
Y Mec
hanical-' Adhesive- Slate-Type
Shingles M '. Shingles
Panels Shingles
Attach Set Shingles,
Lastobond ECO.RF.$ISTn fi6�23fatlgL -
BUILTSand-RSAShineleUnderl— ev`nt� Yes
Gri e Eave&Valley Protector, Yes No No No No Yes
Quints;tips,1507.1.L3/
TopShield ICE&WATER DEFENDER, R90s.1.1a)
RESISTO LB1244
Lastobond Smooth Seal HT,TrhBuilt Yes
Smooth HTS/A Underlayment,Grip-Rite Yes No No Yes Yes Yes Qoint strips,1507.1.1.3/
Smooth Seal HT R90s.1.1.3)
Yes
Colphene FR GR Yes Yes No No No Yes Qafm strips,1s07.1.1.3/
R§011.1.$)
5.6.1 Ad hesive-set ti leis lien ited use of the following Approved underlayment/tile-adhesive combinations.
j.
?-, TABLE 1A ALL'OWABC TILE ADHESIVE-�-UNDERLAYMENT COMBINATIONSh
Underlayment :`: _ ' Adhesive " ' Florida Product Approval
Lastobond TU HT,Tri-BuiltS/A. Dupont"Tile Bond 'Roof Tile Adhesive" FL22525
HTTU Underlayment ICP Adhesives and Sealants"Polyset®AH-160 FL6332
5.7 Allowable Substrates:
'TABLE 2:A SUBSTRATE OPTIONS FOR ADHERED:UNDERLAYMENTS';-
' Substrates(designed,to meet wind loads for projeci)
Underlayment Application',
Type Primer' Materials)
Lastobond Shield,'Lastobond Pro (Optional)ASTM q0S;lyW;o:od�,)SB.or Southern Yellow Pine
HT-N,RESISTO SA SMOOTH PLY Deck/ D41,Elastocol Stick,
40jastobond Shield HT, sheathing Elastocol Stick Zero
Lastobond Pro HT--S, ASTM D41 structural concrete
Er1Vlr0$hl/A HT TU Insulation Lastobond TU HT,
Tri-Built S/A (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Underlays ent,Lastobond.Eaves Stick Zero fiber Roof Board
Protection Sheet,Lastobond 195,. !e"-
rLa bond ECO;RESISTO LB123 dhering
TRI-BUILT Sand-R S
nderlayment rip-Rite Eave&
Valley Protector,TopShield ICE& (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
WATER DEFENDER,RESISTO Base Sheet Stick Zero G
LB1244,Lastobond Smooth Seal
HT;Tri-Built Smooth HT S/A
Underlayment or Grip-Rite
Smooth Seal HT
Deck/ (Optional)ASTM Plywood
sheathing
self- ASTM D41. structural concrete
Colphene FIR GR adhering Insulation Yp(Optional)Elastocol Dens Deck,Prime or SECUROCK Gypsum-
, Stick-Zero Fiber Roof Board
Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified-Sopra-
Stick Zero G
t Refer to Tile Manufacturers orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report.S18010.06.09-R19
Certijlcate'gjAuthorization#32455 7TM EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21 I
Soprema Roof UndePlayrnents Revision M,12/15/2020
Page 5 of 9
4
N_Enno�etc.
TABLE•2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application
Substrates(designed to meet wind.loads for project)
Type Primer Material(s)
Lastobond TU HT,Tri-Built S/A.HT
TU Underlayment,RESISTO
LB1236,TRI-BUILT Sand-R SA self- Existing RESISTO EXTERIOR Existing sand-surfaced,glass-fiber surfaced,
Shingle Underlayment,Grip-Rite adhering substrate PRIMER mineral-surfaced or film-surfaced roof
Eave&Valley Protector or underlayment*
TopShield ICE&WATER
DEFENDER
*Final acceptance of any existing substrate in a re.roof(tear-ofji installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT,Tri-Built S/A HT
TU Underlayment,RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE&
WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER'if'the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not.less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof.Tile Installation Manual, Sixth Edition,Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1. Maximum Design Pressure=-45:0 usf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
eertifcate of Authorization#32455 7-EDMON(2020)FBC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 6 of 9
ONEMOletc.
#3 Maximum Design Pressure 120.0 Dsf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA'SMOOTH PLY 40,self-adhered.
Underlayment: Lastobond.TO HT;Tri-BuiltS/A HTTU Underlayment,self-adhered.
#4 Maximum Design Pressure=-156.0.Dsf:
Deck: Min.15/32=inch APA-rated BCX plywood(may be installed C-side up)to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TO HT,Tri-Built S/A HTTU Underlayment,self-adhered.
#5 All other direct-deck, adhered uriderlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
5.8.3.2 Mechanically-Attached.Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High.Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter,3.
Alternatively,the maximum design pressure for the selected assembly.shall meet or exceed at least the.Zone 1
design pressure:determined in accordance with FBC 1609 or FBC Residential Chapter 3.. Elevated pressure zones
shall employ.an-attachment density.designed.by a qualified design professionat-to'resist the elevated pressure
criteria. Commonly used methods"are ANSI/SRRI WD1,FM Loss Prevention.Data Sheet 1-29,,Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure=-60.0-Dsf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction,of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-
inch o.c.at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT Tri-Built S/A HT TU Underlayment,self-adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings,underlayment
attachment shall be in accordance with the manufacturer's-Installation instructions and attachment of the
insulation or:coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3 EXPOSURELTNIITATIONS
Underlayment Prepared Roof Cover £" Maximum
Installation Type Exposure'(days)
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB1236,TRI- Mechanically
BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector,TopSh)eld ICE 30
&WATER DEFENDER or RESISTO LB1244 attached
Lastobond TO HT,Tri-Built S/A HT TO Underlayment Adhesive-set the roof 30
system
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Mechanically
Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A attached 90
Underlayment or Grip-Rite Smooth Seal HT
Lastobond TO HT,Tri-Built S/A HT TU Underlayment or Colphene FR GR Mechanically 180'
attached
i
I
I
t
t
c
NEMO ETC,LLC Evaluation Report 518010.05.60-R19 i
Certijltate ojAuthorization 032455 7-EDMON(2020)FBC NON-HVHZ EVALUATION FL2569-R21 j
Soprema Roof-Underlayments Revision 19:12/15/2020 I
Page 7 of 9
E
(NNEmoletc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment indirect-deck tile roof.asserriblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECkTILE;INSTALLATIONS
Underlayment Tile Profile Staging Method' - - Maximum Slope
Flat Max.104ile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12
followed by 8 tiles high onslope,as show_n below)
Lastobond TU HT,Tri- rr
Built S/A HT TU l
1 ..
Underlayment Lugged
Al .
Colphene PR GR Flat Max.10-tile,'stack 5:12
Lugged Max.10-tile stack 6:12
•
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any-dust and debris prior to application,and prime the substrate(if applicable).
6.2.1 Installation of RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or
TopShield ICE&WATER DEFENDER self-adhering underlayment in a reroof(tear-off)application atop an existing
underlayment(per Table 2) requires priming of the existing substrate with.RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the,installer and the
Authority Having Jurisdiction. Should a question arise as to,the suitability.of an existing substrate to receive
RESISTO 1_61236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6.3 Lastobond-TU HT, Tri-Built S/A HT TU Underlayment, Lastobond-.Shield, Lastobond Pro HT=N;.RESISTO.SA.,
SMOOTH PLY 40,Lastobond Shield.HT, Lastobond Pro.HT-S,EnviroShieid,Lastobond'Eaves,Protection Sheet,.
Lastobond 195, Lastobond Eco,Lastobond Smooth Seal HT,Tri=Built Smooth HT S/A Underlayment,Grip-Rite
Smooth.Seal HT, RESISTO LB1236, 'T,RI-BUILT Sand-R:SA Shingle Underlayment; Grip-;Rite. Eave'•&-Valley
Protector,TopShield ICE&WATER:DEFENDER,'RESISTO'L61244 or'CoI hens FIR GR:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type If felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certi}lcate ofAutharization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 8.of 9
ONEMID'jetc.
If 6.3.2 Tile APP110tions:
Limited to Lastobond TU HT,Tri-Built S/A HT TU Underlayment of-Colphene FR GR.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRl Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation.of this.
product.
. MANUFACTURING PLANTS:
. Contadt the named'O.A entity for manufacturing facilities covered by F.A.C.Rule 61G20-3.CA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
UL,LLC-QUA9625;(314)57873406 k.chancellor@us.,ul.com
-END:OF EVALUATION REPORT-
I
NEW ETC,LLc Evaluation Report S18010.06.09-1119
Certificate of Authorization#32455 71"EDITION 12020)FBC NON-HVHZ EVALUATION FL2569-R21 �
Soprema Roof Underlayments Revision°19:12/15/1020
Page 9 of 9 {
i