HomeMy WebLinkAboutDock Example - Grated Terminal PlatformDOCK EX AMPLE - GRATED TERMINA L PLATFO RM -_
Construction Guidelines in Florida for Minor Piling -Supported Structures Constructed in or over
Submerged Aquatic Vegetation (SAV), Marsh or Mangrove Habitat
U.S. Army Corps of Engineers/National Marine Fisheries Service —August 2001
"GRATED DECKING"
NOTES:
Means manufactured with a minimum of
• Not to scale.
-kr
"
43 % open space.
. All widths are maximum dimension.
4- eett,,r-
� ••
All heights are minimum dimension.
Spacing of pilings through SAV beds shall
. Piling supported structures over SAV
- = -
be a minimum of 10-feet on center,
should be oriented north -south to the
2-feet
extent practicable.
�-►�
MIDPOINT TURNAROUND
• MHW = mean high water
Only for docks over 200-feet long.
10=feei-
;ram:
LIFT ONLY
No roof.
Thigh
Vessel should be stored as above
MHW as possible.
o c 1 s>
STERN WALKWAY
t Allowed if lift constructed.
4,feet May be less than 4-feet wide
g',
' if longer slip is needed.
�0-feet"
MINIMUM HEIGHT —►
No less than 5-feet above MHWIVI
s
5-feet
--- ACCESS CATWALKS 3-feet
3-feet wide if grated decking. ; _ _ M _ _ _ MHW _ _
3-feet above MHW to facilitate
y Width of boat access. r
slip/Iift_ rA,Cantilevered off main structures;
a ll,i "
z may vary. ,• no additional pilings.
Feet 3-feet
OVERHEAD PLAN VIEW FRONT PLAN VIEW
VER: 201407
N
W B
DOCK EXAMPLE -WOOD PLANK TERMINAL PLATFORM
Construction Guidelines in Florida for Minor Piling -Supported Structures Constructed in or over
Submerged Aquatic Vegetation (SAV),. Marsh or Mangrove Habitat
U.S. Army Corps of Engineers/National Marine Fisheries Service —August 2001
a 2-feet
4-feet,"
1Vidth-,of
§lip/lift _��
iay vary.
4-feet 2-feet 2-feet
OVERHEAD PLAN VIEW
The gaps between deckboards shall be a
minimum of 1/2 inch.
Spacing of pilings through SAV beds shall
be a minimum of 10-feet on center.
- MIDPOINT TURNAROUND
Only for docks over 200-feet long.
LIFT ONLY
No roof.
Vessel should be stored as Thigh above
H
MW as possible.
NOTES:
• Not to scale.
• All widths are maximum dimension.
• All heights are minimum dimension.
• Piling supported structures over SAV
should be oriented north -south to the
extent practicable.
• MHW = mean high water
STERN WALKWAY
Allowed if lift constructed.
May be less than 4-feet wide
"
if longer slip is needed.
l0-fee
-_ t
MINIMUM HEIGHT
No less than 5-feet above MHW
mom
p
ACCESS CATWALKS
2-feet wide if wood decking.
3-feet above MHW to facilitate
Oat access. �- -
Cantilevered off main structures;
no additional pilings.
5-feet
JI _-_ 3=feet -.
FRONT PLAN VIEW
VER: 201407
Key' for Construction Conditions for Docks or Other Minor Structures Constructed
in or Over Johnson's Seagrass (Halophila johnsonii)
National Marine Fisheries Service/U.S. Army Corps of Engineers
October 2002
la. The construction site is within the known range of Johnson's seagrass occurrence (Sebastian Inlet
to central Biscayne Bay in the lagoonal systems on the east coast of Florida). Go to 2.
lb. The construction site is not within the known range of Johnson's seagrass occurrence but
submerged aquatic vegetation (SAV) is present at the site. Use `Dock Construction Guidelines in
Florida for Docks or Other Minor Structures Constructed in or over Submerged Aquatic
Vegetation, Marsh or Mangrove Habitat" - U.S. Army Corps of Engineers/National Marine
Fisheries Service, August 2001.
lc. The construction site is not within the range of Johnson's seagrass and SAV is not present at the
site: No construction conditions for SAV are necessary.
2a. Seagrass survey for Johnson's seagrass is performed at the proposed site during the April 1—
August 31 growing season. Go to 3.
2b. No survey for Johnson's seagrass is performed at the proposed site during the growing season, or a
survey is performed at the proposed site but is outside of the growing season. Go to 4.
3a. Johnson's seagrass is present at the proposed construction site. Go to 5.
3b. Johnson's seagrass is not present at the proposed construction site. Go to 6.
4a. The construction is in an area designated by the National Marine Fisheries Service - Protected
Resources Division (NMFS-PRD) as critical habitae for Johnson's seagrass. Use `Dock
Construction Guidelines in Florida for Docks or Other Minor Structures Constructed in or over
Submerged Aquatic Vegetation, Marsh or Mangrove Habitat" - US. Army Corps of
Engineers/National Marine Fisheries Service, August 2001, except that light -transmitting
materials2 (LTMs) shall comprise 100% of all pedestrian surfaces waterward of the mean low
water (ML O) line.
4b. The construction is not in an area designated by NMFS-PRD as critical habitat for Johnson's
seagrass. Use `Dock Construction Guidelines in Florida for Docks or Other Minor Structures
Constructed in or over Submerged Aquatic Vegetation, Marsh or Mangrove Habitat" - U.S. Army
kL,�ws of cngineersI ational Marine Fisheries Service, August 2001, except that LTMs shall
comprise at least 75% of all pedestrian surfaces waterward of the MLW line and a minimum f-
inch spacing shall be maintained between all wooden deckboards used waterward of the MLW
line.
5a. The construction is in an area designated by NMFS-PRD as critical habitat for Johnson's seagrass.
Use `Dock Construction Guidelines in Florida for Docks or Other Minor Structures Constructed
in or over Submerged Aquatic Vegetation, Marsh or Mangrove Habitat" - U.S Army Corps of
Engineers/National Marine Fisheries Service, August 2001, except that LTMs shall comprise at
least 75% of all pedestrian surfaces waterward of the MLW line and a minimum 1-inch spacing
shall be maintained between all wooden deckboards used waterward of the MLW line.
5b. The construction is not in an area designated by NMFS-PRD as critical habitat for Johnson's
seagrass. Use `Dock Construction Guidelines in Florida for Docks or Other Minor Structures
Constructed in or over Submerged Aquatic Vegetation, Marsh or Mangrove Habitat" - U.S. Army
Corps of Engineers/National Marine Fisheries Service, August 2001, except that all pedestrian
surfaces directly over Johnson's seagrass areas shall be constructed of LTMs and a minimum
This key was modified in October 2002 to change the percent light transmittance requirement of the grids from
46 to 43 as stipulated in Note #3 .
1-inch spacing shall be maintained between all wooden deckboards used waterward of the
MLW line.
6a. The construction is in an area designated by NWS-PRD as critical habitat for Johnson's seagrass.
Use `Dock Construction Guidelines in Florida forpocks or Other Minor Structures Constructed
in or over Submerged Aquatic Vegetation, Marsh or Mangrove Habitat " - U S. Army Corps of
Engineers/1Vational Marine Fisheries Service, August 2001, except that a minimum ]-inch
spacing shall be maintained between all wooden deckboards used waterward of the MLW line.
6b. The construction is not in an area designated by NMFS as critical habitat for Johnson's seagrass.
Go to 7
7a. SAV other than Johnson's seagrass is present at the site. Use `Dock Construction Guidelines in
Florida for Docks or Other Minor Structures Constructed in or over Submerged Aquatic
Vegetation, Marsh or Mangrove Habitat" - U.S Army Corps of Engineers/National Marine
Fisheries Service, August 2001.
7b. No SAV present. No construction conditions for SAV are necessary.
Notes:
This key is meant to complement but not supersede the "Dock Construction Guidelines in Florida for Docks or
Other Minor Structures Constructed in or over Submerged Aquatic Vegetation, Marsh or Mangrove Habitat - U.S.
Army Corps of Engineers/National Marine Fisheries Service, August 2001. Docks incorporating light -transmitting
materials shall not exceed the dimensions recommended in the Guidelines.
r'edend lCegister 65 FR 17786, Apri15, 2000, Designation of critical habitat for Johnson's seagrass.
'- Light -transmitting materials are made of various materials shaped in the form of grids, grates, lattices, etc., to allow
the passage of light through the open spaces. All light -transmitting materials used for dock construction in the
known range of Johnson's seagrass shall have a minimum of forty-three (43) percent open space.
This key was modified in October 2002 to change the percent light transmittance requirement of the grids from
46 to 43 as stipulated in Note #3 .