Loading...
HomeMy WebLinkAboutBuilding Plans30'-0" CARPORTS.; ME 12'-0" —0" 15'-0" OPE CODE INFOR TION ROLL —UP <t I CODE VERSION FBC 2020 7th Edition ASCE-7-16 r_______________________________________________________________________ � UOIIR________________________________________________ � � _ �MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE 11—B 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND i RISK CATEGORY I FIRE PROTECTION NONE CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS i ARE THE RESPONSIBILITY OF OTHERS. 2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15. 5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS WITH SEAL WASHERS ®6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED WELDER. 9.CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH. 10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. .FIRE SUPPRESSION SYSTEM NONE j"x54" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END —WALL POST 2" MIN. BASE RAIL GRAD _ it-� II —II I —II ' —'{a N II�—III-III i° I <' —� j—I I 2,500 PSI 4" CONCRETE < SLAB WITH 10GA. W.W.F. OR FIBER MESH8. h-12" (2) #5 REBAR ® 6" O.C. /MINIMUMSOIL BEARING CONTINUOUS WITH MINIMUM CAPACITY 500 PSF(TYP.) 25" OVERLAP SPLICE i i i i i i FRAME Ol1T iM OCCUPANCY UTILITY, U WIND SPEED Vult-150mph EXPOSURE B ENCLOSURE ENCLOSED/OPEN INTERNAL PRESSURE COEFF. +/— 0.18/0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD t0PSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOFN/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,350 SQ. FT. CONCRETE FOUNDATION/BASE RAIL REVISIONS NOTES: SUB—GRADE SOILS: —TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2020 FLORIDA BUILDING CODE, 7TH EDITION —BOTTOM OF CONCRETE FOOTING SHALL BE MINIMUM OF 12" BELOW UNDISTURBED OR ANCHOR DETAIL REV DESCRIPTON DATE BY 1 LEAN-TO LEG HEIGHT 4/10/21 MTB PLAN VIEW 2.5" DOOR FRAMING RECESS ENGINEERED GRADE" CONCRETE: -- —MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS —ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE REINFORCING STEEL (REBAR) REQUIREMENTS: 1 4" DOOR WIDTH ELEVATION VIEW i Oan MTB o I M i ' —MINIMUM GRADE 40 STEEL —REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: -THE REBAR IS BENT COLD —THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6—BAR DIAMETERS: AND —REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT DOOR FRAMING " RECESS � i i DATE4/2/21 T J .75" OOR WIDT 4" OPTIONAL ROLL -UP DOOR LOCATION: 4930 Gravers Road, Fort Pierce slzE 30'L X 45'W X 14'H EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" CONCRETE SPLASH -GUARD RECESS HORIZONTALLY TO 6" VERTICALLY. —COVER: —3" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 1j" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF J" FOR FINE GROUT, AND J" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 11" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER, FRAME 0l1T o ih GALVANIZATION: —METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, SWINGING CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DOOR DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. o 1C/ i !� 0"72-2,( 1 M FOR (n REVIEWED i E I MIN. 2,500 PSI 4" CONCRETE SLAB WITH TOGA. W.W.F. (OR CODE COMPLIANCE - ST. LUCIE COUNTY BOCC Q) °° FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER `----------------------------------------------------------------------RO_LL=_U.P----------------------------- - DOOR FRONT 12"x12" REINFORCED FOOTER M ------------------------ -------------------------------------- -I W 4� 1 1 �21 -O"" - I - 12'-O" 9'-0-� 45'-0" +� ° T ��6 TOR C ri5� If > z � a F- Matthew T. BaldWin P.E. Florida License —1 Sheet: CA— I O F 4 q 12 -11A"--l-2'-1 o.c. LEFT SIDE WALL ROLL -UP DOOR ORED) I q 1W —�-2'-1 W-' —2'-1 3•_114" o.c. mm SWINGING DOOR 3'-0� 3'-.M V-Q '''' V-Q '' V-Q" V- Q'' RIGHT SIDE WALL 0 i V CODE INFORMATION CODE VERSION FBC 2020 7th Edition, ASCE-7-16 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II-B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph INTERNAL PRESSURE COEFF. +/- 0.18/0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,350 SQ. FT. REVISIONS IREVI DESCRIPTON IDATE I BY 1 LEAN-TO LEG HEIGHT 4/10/21 1 MTB MTB 4/2/21 4930 Grovers Road, Fort Pierce 30-L X 45-W X 14'H 07 W_ z 3'_8M. 3'_811IfbS. 3'_8 3'_8 3'_8 3._811. fTSb w 13'-0' x FRAME our FRAME a� 1FIEE E® FOR z ®� MPLIANCE W 4/ 1 1 /21 1 -4" COUNTY ST. 0®�� WQ Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA-2 Cr 4 RIGHT SIDE LEAN-TO_ vyHL� I`' Cn MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC) 12 14x4" SELF -DRILLING NIPPLE TO V `7 \BASE RAIL NIPPLE BASE I POST TO BASE RAIL CONNECTION 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) # 12-14xj" SELF -DRILLING SCREWS NON-STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL INTERI, #12-144" SELF -DRILLING SCREWS ® 10" O.C. MAX., 3" MAX. FROM CORNERS HORIZONTALLY/ 4" MAX. FROM CORNERS VERTICALLY EXTERIOR 6 MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC)#12 14x4" SELF -DRILLING 2"x2"x2" 16 GA. ANGLE CUP SECURED WITH (4) #12-14xj" SELF -DRILLING SCREWS I -I 11-111-1 I Ed I I1 I = l 'I=IIMI I IM�1=1I1- , END POST TO BASE RAIL CONNECTION 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xj" SELF -DRILLING SCREWS VARIES TO STD. MAX.SPM SPACING I�f STD. MAX. SPACING SIDE WALL ROLL -UP DOOR/FRAME OUT HEADER DETAIL PER MANUFACTURERS INSTRUCTIONS #14x1" SELF -DRILLING SCREWS ® 6" O.C. MAX. & 6" MAX. FROM CORNERS DOOR FRAME TO POST CONNECTION ROLL -UP DOOR TO POST CONNECTION 2"x2"x2" 16 GA. ANGLE CUP SECURED WITH (4) #12-14xj" SELF -DRILLING SCREWS INTERMEDIATE POST TO HEADER/BASE RAIL/OR WINDOW RAIL DETAIL MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)# 12-14xj" SELF -DRILLING SCREWS POST TO TRUSS CONNECTION TO 1 "x2j" 16 GA. U-CHANNEL BRACE, MIN. 24" UP TO 7' POST, Mlr 48" OVER 7' POST. MIN. 45' TO MAX. 60' FROM HORIZ. (EXCLUDE END -WALLS). SECURED WITH (4)#12-14x4" SELF -DRILLING SCREWS. MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SCREWS 144" SELF -DRILLING BOX EAVE RAFTER TO POST CONNECTION DETAIL Enclosed Design Pressures - 150 mph Basic Wind Speed Zone Roof Wall 1 2n 2r 2e 3r 3e 4 5 9.6 10.1 9.6 9.6 14.8 14.8 14.8 17.9 -11.5 -36.6 -29.2 -11.5 -63.8 -53.6 1 -16.6 -22.6 Open Design Pressures - 150 mph Basic Wind Speed Zone Roof Wall 1 2n 2r 2e 3r 3e 4 5 14.9 21.0 14.9 14.9 21.0 21.0 21.0 23.7 -17.9 -56.4 -34.1 -17.9 -65.7 -56.4 1 -22.5 -28.0 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14x4" SELF -DRILLING SCREWS SINGLE OR DOUBLETS HEADER CONNECTION DETAIL OPTION 1 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14x4" SELF -DRILLING SCREWS '2-1-2-1' (6" O.C. (9" O.C. MAX.)) 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-14x1" SELF -DRILLING SCREWS TO EACH RAFTER. ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION NIPPLE TRUSSED RAFTER CONNECTION DETAIL PPLE MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH 12-14x4" SELF -DRILLING EWS SINGLE OR DOUBLETS HEADER HEADER CONNECTION DETAIL OPTION 2 2 - 2"x2"x2" 16 GA. ANGLE CLIPS SECURED WITH (4) #12-14xj" SELF -DRILLING SCREWS (PER CLIP) LEAN-TO TO TRUSS CONNECTION APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR . ROLL -UP DOOR JANUS INTERNATIONAL CORPORATION FL21450.3 SERIES 3100 CODE VERSION FBC 2020 7th Editior ASCE-7-16 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II-B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-150mph ENCLOSURE ENCLOSED/OPEN INTERNAL PRESSURE COEFF. +/- 0.18/0.0 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 11,35o SQ. FT. LEG HEIGHT MTB 4/2/21 4930 Grovers Road, Fort Pierce 1-"- 301 X 45'W X 14'H 11 171 U-) 4/1 1 /21 J Q Matthew T. Baldwin P.E. Florida License #64608 o LJ o Sheet: CA-4 OF 4