HomeMy WebLinkAboutProduct Approval; Roof DeckBCIS Home tog In User Registration ! Hot Topic Submit Surcharge Stats & Facts Publications Contact Us „BCiS Site Map !Inks Search
Florida
?� �jai Product Approval
( USER: Public User
Product Approval Menu > Product or An llcatlon Search > ARAIJOtloo Lkt > Application Detall
FL #
FL27402-112 •Z-7gOZ- tZ'2-
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
1
Carports Anywhere
10858 S.E. County Road 221
Starke, FL
(352)468-1116
bodom@carportsanywhere.com
Brandie Odom
bodom@carportsanywhere.com
Structural Components
Roof Deck
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the ]ohnathan Green
Evaluation Report
Florida Ucense PE-88223
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 06/23/2023
Validated By Brian ]aks, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL27402 R2 COI Letter of Certification -Ca [ports Anywhere sealed.pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM E 1592 2005
FM 4471 1992
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
08/04/2020
Date Validated
08/10/2020
Date Pending FBC Approval
08/19/2020
Date Approved
10113/2020
Summary of Products
FL #
Model, Number or Name
Description
27402.1
Hampton Rib Roof Panel
Hampton Rib Roof Panel over Open Framing
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +54.7 psf/-57.3 psf
Other: See evaluation report for various design pressures
Install per Manufacturer's details. Not for use In HVHZ Zones. I
Installation Instructions
FL27402 R2 H Hampton Rib Roof Panel DRAFT sealed pdf
Verified By: 7ohnathan E Green, P.E. 88223
Created by Independent Third Party: Yes
Evaluation Reports
FL27402 R2 AE Hampton Rib Roof Panel DRAFT sealed.pd�
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399, Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. C R,ydght 2007-2013 State of Florida.:: Privacy Statement :: Accesslbl0ty, Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact a50.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dice here .
Product Approval Accepts:
E-LEI
Credit Card
Safe
...
Force Engineering &'Testing
195301tambiewood Drive
Humble, Texas 77338
Plume: (281) 540-6603 FAX: (281) 540-9966
Website: www.foreecngineeringtesling.com
Product Evaluation Report
CARPORTS ANYWHERE
Hampton Rib Roof Panel over open framing
Florida Product Approval # 27402.1 R2
Florida Building Code 2020
Per Rule 61G20-3
Method: 1—D
Category: Structural Components
Subcategory: Roof Deck
Compliance Method: 61G20-3.005(i)(d)
NON HVHZ
Product Manufacturer:
Carport Anywhere
10858 S.E. County Road 221
Starke, Florida 32091
Engineer Evaluator:
Johnathan Green, P.E. # 88223
Florida Evaluation ANE ID:12902
Validator•
Brian Jaks, P.E. #70159
Contents:
Evaluation Report Pages 1- 4
ITEM HAS BEEN
ALLY SIGNED AND
ED BY JOHNATHAN
:N ON THE DATE
CENT TO THE SEAL.
I COPIES OF THIS
:NT ARE NOT
:RED SIGNED AND
AND THE
IRE MUST BE
) ON ANY
)NIC COPIES.
FL# 27402.1 R2
Force Engineering & Testing
l
19530 Ramblewood Drive
Humble, Texas 77338
Phone: (281) 540-6603 ITAX: (281) 540.9966
Website: www.forecengineeringiesting.com
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2020, Sections 1504.3.2,1504.7.
Product Description:
Hampton Rib. 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened
structural roof panel. Structural Application.
Panel Material/Standards:
Material:
26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50
29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80
Conforming to Florida Building Code 2020 Section 1507.4.3. Optional paint finish.
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2020, Section 1507.4.3.
Panel Dimension(s):
Thickness: 26 Ga.: 0.0185" min. order thickness
29 Ga.: 0.0142" min. order thickness
Width: 36" maximum coverage
Rib Height: X" major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener:
#12-14 x %" HWH SD#3 with 14mm neoprene bonded washing or approved equal.
Corrosion Resistance: Per Florida Building Code 2020, Section 1507.4.4.
Substrate Description:
Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel
framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel
gauge. Framing must be designed in accordance w/ Florida Building Code 2020.
Allowable Design Pressures:
Maximum Design Pressure:
-57.3 psf
-72.9 psf
-67.7 psf
+46.9 psf
+54.7 psf
Panel Fastener Pattern:
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
Panel Span:
51-V O.C.
4'-0" O.C.
4'-0" O.C.
5'-0" O.C.
4'-0" O.C.
Substrate:
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
Steel Framing
Min. 14 Ga.
Steel Framing
Min.18 Ga.
I Steel Framing
Min. 38 Ga.
Steel Framing
w—lul, rressure muuues a aarery raccor = t.u.
lu
��itv1
'd!//l`� 1A loll IIIi9 \
FL# 27402.1 R2
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
Force Engineering & Testing
19530 Rumblewood Drive
Humble, Tents 77338
I'bone: (281)540-6693 FAX: (281)540-9966
Website: wsvw.rorceengineeringtesting.cotu
Table "B" 29 Ga. Hamoton Rib Roof Panel
Maximum Design Pressure:
-57.3 psf
1 -150.9 psf
1 +39.0 psf
1 +143.1 psf
Fastener Pattern:
6"4"-r-3"-6"4"4-
6"-3"-6"-3"-6"-3"-6a
6"-3"-6"3"-6"-3"-6"
6"-3•-V-21„-6"-3"-6„
Fastener Spacing
4'-0" O.C.
2'-0" O.C.
4'-0" O.C.
2'-0" O.C.
Design Pressure includes a safety Factor = 2.0.
Code Compliance:
The product described herein has demonstrated compliance with
The Florida Building Code 2020, Section 1504.3.2, 1504.7.
Evaluation Report Scope:
The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2020, as relates to Rule 61G20-3.
Performance Standards:
The product described herein has demonstrated compliance with:
■ ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
■ FM 4471-92 - Foot Traffic Resistance Test
Reference Data:
1. ASTM E 1592-05 (2012) Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667-0060T-18A-E, 667-0061T-18A-D
2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667-0060T-18F, 667-0061T-18E
3. , Certificate of Independence
By Johnathan Green, P.E. (No. 88223) @ Force Engineering & Testing
(FBC Organization # ANE ID: 12901
Test Standard Equivalency:
1. The FM 4471-10, Foot Traffic Resistance test standard is equivalent to
FM 4471-92.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
rrEM HAS BEEN
ALLY SIGNED AND
ED BY JOHNATHAN
iN ON THE DATE
CENT TO THE SEAL.
I COPIES OF THIS
:NT ARE NOT
?RED SIGNED AND
AND THE
IRE MUST BE
) ON ANY
)NIC COPIES.
FL# 27402.1 R2
i
Force Engineering & Testing
19530 Ramblewond Drive
Flumble, Texas 77338
I'bune: (281) 540-6603 FAX: (281) 540-'9966
W ebsite: 51' FI'K'.f01'l'l'l'al llll'e rl ngtesti n;,•.cmn
Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2020, including Section
1507.4.2 and In accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per manufacturer's recommended details.
Insulation:
Manufacturer's approved product (Optional)
Roof Panel Fire Classification:
Fire classification is not part of this acceptance.
Shear Diaphragm:
Shear diaphragm values are outside the scope of this report.
Design Procedure:
Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2020 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2020
Chapter 22 for steel, and Chapter 16 for structural loading.
ITEM HAS BEEN
'ALLY SIGNED AND
ED BY JOHNATHAN
:N ON THE DATE
CENT TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
FL# 27402.1 R2
CT
' 1
Force Engineering & Testing
19530 Rumblewood Drive
Humble, Texas 77338
Phone: (281)540-6603 FAX: (281)540-9966
Website: irww.rorceengineeringlesling.com
26 GA. HA`dPTON RIB FASTENER PATTERN 2-1-2-1
#12-14 x H'WH S03 9!/ I?W BONDED NEOPRENE WASHER
29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6"
# 12-• 1 a x 3/4" IVAN ;D:i W/ 141.0A 00NDE0 NEOPRENE WASHER
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
FL# 27402.1 R2