HomeMy WebLinkAboutEngineeringComponent & Cladding Wind Loads Prepared for DVT Hurricane Shutters Inc Calculations by Seaside Engineers Project: Winkler Residence Certificate of Authorization No. 32048 Location: 675 W Lake Jasmine Circle APT 206 4265 60th Court Fort Pierce, FL 34962 Vero Beach, Florida 32967 Project ID: (722) 202-8008 info@seasideengineers.com Date: 6/17/2021 www.seasideengineers.com Design Information Risk Category II Windspeed 160 mph Exposure D Int. Press. Coef., GCp,(+/-) 0.18 a 4.00 feet Select the appropriate fastener size and spacing using the pre-engineered attachment schedule for the Florida Approved Product(s) or NOA used on this job. The contractor is responsible to ensure the use of the proper material, reinforcement, components, etc. to meet the indicated pressure per the product approval engineering document. The contractor is responsible to verify the component is in the appropriate zone using the "a" dimension shown above and diagrams shown below. The building pressures are calculated using the Allowable Stress Design. Contact Seaside Engineers immediately if the substrate at the attachment locations appears to have deterioration. abnormalities. damaee. or other conditions resultine in questionable inteerity. ID Opening Description Area (sqft) Zone Florida Product Approval # or NOA Manufacturer Model Building Design Pressure (PSF) Max Product Allowable Pressure (PSF) 1 Shutter 14.2 5 FL389.2 ASSA Bertha HV Accordian 39.7 -52.6 205.0 -205.0 2 Shutter 14.2 5 FL389.2 ASSA Bertha HV Accordian 39.7 -52.6 205.0 -205.0 3 Shutter 13.6 5 FL389.2 ASSA Bertha HV Accordian 39.8 -52.8 205.0 -205.0 4 Shutter 13.6 5 FL389.2 ASSA Bertha HV Accordian 39.8 -52.8 205.0 -205.0 5 Shutter 17.1 5 FL389.2 ASSA Bertha HV Accordian 39.2 -51.6 205.0 -170.0 6 Shutter 17.1 5 FL389.2 ASSA Bertha HV Accordian 39.2 -51.6 205.0 -170.0 7 Shutter 13.6 5 FL389.2 ASSA Bertha HV Accordian 39.8 -52.8 205.0 -205.0 8 Shutter 13.6 5 FL389.2 ASSA Bertha HV Accordian 39.8 -52.8 205.0 -205.0 9 Shutter 13.6 1 5 FL389.2 IASSA Bertha HV Accordian 39.8 -52.8 1 205.0 1 -205.0 10 Shutter 13.6 5 FL389.2 ASSA Bertha HV Accordian 39.8 -52.8 205.0 -205.0 11 Shutter 13.6 5 FL389.2 ASSA Bertha HV Accordian 39.8 -52.8 205.0 -205.0 12 Shutter 13.6 5 FL389.2 ASSA Bertha HV Accordian 39.8 -52.8 205.0 -205.0 13 Shutter 21.0 5 FL389.2 ASSA Bertha HV Accordian 38.7 -50.5 205.0 -140.0 14 Shutter 13.6 5 FL389.2 ASSA Bertha HV Accordian 39.8 -52.8 205.0 -205.0 15 Shutter 14.9 5 FL389.2 ASSA Bertha HV Accordian 39.6 -52.3 205.0 -205.0 WALL: 'this item has been elec- tromcall2r signed and sealed cy Edward Roslce PE using a DiLgtel Si a- tare. Printed copies of this ,documemt are not ,considered signed and sealed and the signature mast be verified cra a€,,, electronic copies. 2021.06.17 '00'04- 14:31:55 Edward K Roske, PE June 17. 2021