HomeMy WebLinkAboutEvaluation Report; Certain Teed Asphalt Roof Shinglesi OO RECEIVED ,0 .� C NOV, 0,6 201E b NEMO I etc. Certificate of Authorization #32455 Permitting Departmelnt 353 Christian Street, Unit #13 St, Lucie County Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST I CONSULT CERTIFY CertainTeed Corporation Evaluation Report 3532.09.05-R15 20 Moores Road FL5444-1114 Malvern, PA 19355 Date of Issuance: 09/22/2005 (610) 651-5847 Revision 15: 05/29/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: CertainTeed Asphalt Roof Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. - ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOl etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Repo i shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 15. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 CERTIFICATION OF INDEPENDENCE: 1. NEMOletc. does not have, nor does it intend to acquire, or will distributing products it evaluates. 2. NEMO I etc. is not owned, operated or controlled by any company n 3. Robert Nieminen, P.E. does not have nor will acquire, a financial it which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial ii product. 5. This is a building code evaluation. Neither NEMOIetc. nor Rober project on which this Evaluation Report, or previous versions ther( specifically for that purpose. The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 05/29/2018. This does not serve as an electronically signed document. acquire, a financial interest in any company manufacturing or Auring or distributing products it evaluates. in any company manufacturing or distributing products for in any other entity involved in the approval process of the Nieminen, P.E. are, in any way, the Designer of Record for any f, is/was used for permitting or design guidance unless retained ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roof 5 demonstrated compliance with the following sections of (2017) Florida Building Code, Residential Volume thn Compliance is subject to the Installation Requirements an ONEMO I etc. ngles, as produced by CertainTeed Corporation, have e 6`h Edition (2017) Florida Building Code and 61h Edition gh testing in accordance with the following Standards. Limitations / Conditions of Use set forth herein. ;Section:'.`_ ,. Proe Standards Year ., 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity. ', Examination;` Reference.,`• ,. :Date UL (TST 1740) ASTM D3161 94NK9632 05/15/1998 UL (TST 1740) ASTM D3161 99NK26506 11/23/1999 UL (TST 1740) ASTM D3161 03CA12702 05/27/2003 UL (TST 1740) ASTM D3161 03CA12702 06/16/2003 UL (TST 1740) ASTM D3161 03NK29847 10/03/2003 UL (TST 1740) ASTM D3161 04CA11329 05/24/2004 UL (TST 1740) ASTM D3161 04CA32986 12/03/2004 UL (TST 1740) ASTM D3161 05NK07049 04/15/2005 UL (TST 1740) ASTM D3161 05NK16778 05/12/2005 UL (TST 1740) ASTM D3161 05CA16778 05/12/2005 UL (TST 1740) ASTM D3161 05NK14836 05/22/2005 UL (TST 1740) ASTM D3161 05NK22800 06/22/2005 UL (TST 1740) ASTM D3462 R684 09/21/2005 UL (TST 1740) ASTM D7158 05NK08037 06/28/2006 UL (TST 1740) ASTM D3161 & D3462 09CA28873 07/23/2009 UL (TST 1740) ASTM D3462 10CA41303 10/07/2010 UL (TST 1740) ASTM D3161 10CA41303 10/08/2010 UL (TST 1740) ASTM D7158 10CA41303 10/27/2010 UL (TST 1740) ASTM D3161 & D3462 10CA44960 11/11/2010 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 13CA32897 11/21/2013 UL LLC (TST 9628) ASTM D3161, D3462 TFWZ.R684 04/22/2014 UL LLC (TST 9628) ASTM D7158 TGAH.R684 04/22/2014 UL LLC (TST 9628) ASTM D3161 & D3462 4786334434 09/16/2014 UL LLC (TST 9628) ASTM D3161 & D3462 4786570826 02/12/2015 UL LLC (TST 9628) ASTM D3161 4786821352 02/21/2015 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4786570717 12/16/2015 UL LLC (TST 9628) ASTM D3161 & D3462 4787195678 02/09/2016 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4787592174 10/21/2016 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4787380356 10/26/2Q16 UL LLC (TST 9628) ASTM D3462 4787380357 10/13/2016 UL LLC (TST 9628) ASTM D7158 4787380357 11/08/2016 UL LLC (TST 9628) ASTM D3161 4787380357 11/09/2016 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4787586427 01/25/2017 UL LLC (TST 9628) ASTM D3161 & D3462 4788042412 11/15/2017 UL LLC (TST 9628) ASTM D3161, D3462 & D7158 4788362767 03/03/2018 UL LLC (QUA 9625) Quality Control Service Confirmation Exp. 03/09/2020 NEMO ETC, LLC Evaluation Report 3532.09.05-1115 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON -HVHZ EVALUATION FL5444-1114 CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 15: 05/29/2018 Page 2 of 15 «ll \..� NEMO 1 etc. PRODUCT4. 4 1 ;�,w Asphalt Shinsles -; "" 4.1.1 CT20TM, XTTM 25, XTTM 30 and XTTM 30 IR are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Arcadia TM, Belmont®, Belmont® IR, Carriage House Shingle®, Grand Manor Shangle®, LandmarkTM, LandmarkTM IR, LandmarkTM Pro, LandmarkTM Pro Solaris, Landmark�jM Premium, LandmarkTM TL, LandmarkTM Solaris, Landmark TM Solaris IR and Landmark TMSolaris Gold/Platinum are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 NorthGate TM is a fiberglass reinforced, laminated, SBS modified bitumen roof shingle. 4.1.4 Presidential ShakeTM, Presidential ShakeTM IR, Presidential Shake TLTM and Presidential Solaris" are fiberglass reinforced, architectural asphalt roof shingles. 4.1.5 HatterasTM, Highland SlateTM and Highland SlateTM IR are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.6 PatriotTM is a fiberglass reinforced asphalt roof strip (shingle (with no cut-outs) providing a laminated appearance through an intermittent shadow line with contrasting bend drops for color definition. 4.2, Hip & Ridge ShinalO 4.2.1 Presidential Accessory, Accessory for Hatteras, Shangle RidgeTM, Shadow Ridge TM, Cedar CrestTM, Cedar CrestTM IR, NorthGate Ridge and NorthGate Accessory are fibergli ss reinforced accessory shingles for hip and ridge installation. 4.3 " Ac' es'sory Starter Strips 4.3.1 High -Performance Starter is a starter shingle, measuring 10" x 36", comprised of a fiber glass mat base and ceramic - coated mineral granules embedded in asphalt. These starter shingles are designed for use with Grand Manor Shangle®, HatterasTM and Highland Slate TM. 4.3.2 Presidential Starter is a starter shingle, measuring.13l-1/4" x 40" (overall), comprised of a fiber glass mat base and ceramic -coated mineral granules embedded in asphalt with a reinforcement on its underside (for impact resistance considerations). These starter shingles, applied using two (2) overlapping layers, are designed for use with Presidential ShakeTM and Presidential Shake TLTM 4.3.3 Presidential Starter IR is a starter shingle, measuring �3-1/4" x 40" (overall), comprised of a fiber glass mat base and ceramic -coated mineral granules embedded in asphalt. These starter shingles, applied using two (2) overlapping layers, are designed for use with Presidential ShakeTM IR. 4.3.4 SwiftStart® Starter Shingle is a starter strip for asphalt roof shingles. Its overall size of 15-1/4" x 38-3/4" yields two (2) 7-5/8" x 38-3/4" starter pieces per shingle. 4.3.5 Universal Starter is a starter shingle, measuring 7" x 36" (overall), comprised of a fiber glass mat base and ceramic - coated mineral granules embedded in asphalt. These starter shingles are designed for use with any CertainTeed shingle measuring 12" x 36" having a weather exposure < 511 . 4.4 Any of the above listed shingles may be produced in AR, (algae resistant) versions. 5.1 This is a building code evaluation. Neither NEW IetC. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report ratings of this product. NEMO ETC, LLC Certificate of Authorization #32455 6T" EDITION (2017) FBC NON• CertainTeed Asphalt Roof Shir refer to current Approved Roofing Materials Directory for fire Evaluation Report 3S32.09.05-111S EVALUATION FL5444-1114 (610) 651-5847 Revision 1S: OS/29/2018 Page 3 of 1S 5.4 Wind Classification: 5.4.1 All shingles noted herein are Classified in accordance w F and/or ASTM D7158, Class H, indicating the shingles = 194 mph). Refer to Section 6 for installation requiren 5.4.2 Presidential Accessory, Accessory for Hatteras, Shan NorthGate Accessory hip & ridge shingles have been NorthGate Ridge and NorthGate Accessory require us( Roof & Flashing Sealant, applied as specified in manu Vasd = 150 mph (V,,it = 194 mph). Refer to Section 6 for 1 5.4.3 High -Performance Starter, Presidential Starter, Pres' Starter have been evaluated in accordance with ASTM to meet this wind rating. 5.4.3.1 High -Performance Starter shingles are limited to use shingles. 5.4.3.2 Presidential Starter shingles must be applied using twi Shake'" and Presidential Shake TLTI shingles. 5.4.3.3 Presidential Starter IR shingles must be applied us Presidential Shake TM IR shingles. 5.4.3.4 Universal Starter shingles are limited to use with Certa < 5". 5.4.4 Classification by ASTM D7158 applies to exposure Calculations by a qualified design professional are r( shingle manufacturer for data specific to each shingle. 5.4.4.1 Analysis in accordance with ASTM D7158 indicates t Roof shingles listed in Section 4.1.1 through 4.1.6 (exce Solaris Gold/Platinum) exceeds the calculated uplift for = 194 mph) for residential buildings located in ExposL having a mean roof height less than or equal to 60 fi these conditions using the installation procedures c requirements, subject to minimum codified fastening shall take precedence. 5.5 All products in the roof assembly shall have quality assr NEIVIO ETC, LLC Certificate of Authorization #32455 6T" EDITION (2017) FBC N CertainTeed Asphalt Roof ON EM® I etc. th FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class re acceptable for us in all wind zones up to Vasd = 150 mph (Vuit ents to meet this wind rating. ;le Ridge, Shadow Ridge, Cedar Crest, NorthGate Ridge and !valuated in accordance with ASTM D3161, Class F. All except of BASF Sonolastic NP 1 adhesive or Henkel PLO Polyurethane acturer's application instructions, for use in wind zones up to istallation requirements to meet this wind rating. iential Starter IR, SwiftStart° Starter Shingle and Universal )3161, Class F. Refer to Section 6 for installation requirements Grand Manor Shangle®, Hatteras'"" and Highland Slate"' (2) overlapping layers and are limited to use with Presidential ng two (2) overlapping layers and are limited to use with ed shingles measuring 12" x 36" having a weather exposure itegory B or C and a building height of 60 feet or less. uired for conditions outside these limitations. Contact the e measured uplift resistance (RT) for the CertainTeed asphalt it Presidential Solaris', LandmarkT"' Pro Solaris and Landmark"" :e (FT) at a maximum design wind speed of Vasd = 150 mph (V„It -e D conditions with no topographical variations (flat terrain) Bt. The shingles are permissible under Code for installation in atailed in this Evaluation Report and CertainTeed minimum requirements established within any local jurisdiction, which audits in accordance with FAC Rule 61G20-3. Evaluation Report 3532.09.05-1115 EVALUATION F1.5444-1114 (610) 651-5847 Revision is: 05/29/2018 Page 4 of 15 ONEMO I etc. 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Installation of asphalt shingles shall comply -with the CertainTeed Corporation current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. 6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the "Steep Slope" directions. 6.3 CertainTeed asphalt shingles are acceptable for use in ref•oof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed p 1 blished installation instructions. 6.4 HIGH-PERFORMANCE STARTER. 6.4.1 Eaves: For the first starter shingle in each roof corner, use five (5) nails as shown below. All other starter shingles require four (4) nails per shingle. Nails must be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. Nails are to be 11 or 12 gauge, corrosion -resistant roofing nails with 3/8" heads. Apply the 10" starter shingle with its factory -applied sealant stripes at the shingle's lower -most edge and nail firmly into the roof deck as near as possible *(maximum ") to the eaves edge while avoiding the sealant. With the starter shingle well fastened to the deck and the sealant low on the starter shingle, it can firmly adhere to the first course shingles. *If nailing within 3" is not possible, nail s closely as possible, then lift and adhere the starter shingle to the underlayment and to the supporting structure with CertainTeed FlintBondTm Asphalt Roofing Cement -Caulk Grade, or approved equal. Rakes: Prior to installation of the field shingles, starter s�'Ingles may be applied up the slope along the rake edge with sealant edge placed closest to the rake edge. Fasten as indicated below. HIGH-PERFORMANCE STARTER SHINGLES in 1 318" (Max. 3") NEMO ETC, LLC Evaluation Report 3532.09.05-1115 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON IHVHZ EVALUATION FL5444-R14 CertainTeed Asphalt Roof Shi Igles; (610) 651-5847 Revision 15: 05/29/2018 Page 5 of 15 NMEMO I etc. 6 5 PRESIDENTIAL STARTER AND VRESIDENTIAL TARTER IR 6.5.1 General: These shingles shall be applied by using two (2) overlapping layers. Begin application of the bottom/lower layer of starter shingles by cutting and applying a 13-3/4" x 20" piece at the lower left rake/eaves corner overhanging rakes and eaves 1/4" to 3/4". Continue along the eaves with full-size 13-1/4" x 40" starter shingles. Each top/upper starter course shingle shall have its 2" top section remoJed at the perforations, resulting in 11-1/4" x 40" shingles. The colored granule portion of the "top" starter shingles sha,l be located nearest the lowermost eave edge. Install the first top/upper starter shingle so that it is flush to the left side and. bottom edges of the first bottom/lower starter shingle. This first top/upper starter shingle shall be 11-1/4" x 38". Continue along the eaves with 11-1/4" x 40" top/upper starter shingles ensuring that the lower edges are flush with the lower edges of the bottom/lower layer. Reference the product's wrapper for more specific details. Eaves: Fasten as shown below. Rakes: After applying tl1e starter shingles at the eaves, but prior to installing the field shingles, starter shingles may be applied up the slope at Ithe rake edge. Fasten as shown below. Fastening: Four nails are required per shingle. Nails shall be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. i ails are to be 11 or 12 gauge, corrosion -resistant roofing nails with 3/8" heads. Presidential Starter and Presidential IR Starter Shingles 4- 6.6 ,• UNIVERSALSTARTER 6.6.1 General: While Universal Starter Strip shingles are specifically designed to be used with shingles 36" length and having a weather exposure of < 5", they may be installed beneath shingles of any length if special precautions are taken. IMPORTANT: In all cases the end joints of the starter and the first course shingles shall NEVER BE LESS THAN 3-1/2" apart. Eaves: The sealant on starter courses should face out and lie as close as possible to the eaves edge of the roof. Fasten as described below. Rakes: After applying the starter shingles at the eaves, but prior to installing the field shingles, starter shingles may be applied up the slope at the rake edge with sealant facing out and nearest to the outer roof edge. Fasten as described below. Fastening: Use four nails on these starter shingles as shown below. The sealant on starter courses shall lie as close as possible to the eaves edge of the roof. Nails shall be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. Nails are to ie 11 or 12 gauge, corrosion -resistant roofing nails with 3/8" heads. UNIVERSAL STARTER 12" 12° I 12° 7. NEMO ETC, LLC Evaluation Report 3532.09.05-R15 Certificate of Authorization #32455 6N EDITION (2017) FBC NON- VHZ EVALUATION F1.5444-1114 CertainTeed Asphalt Roof Shini les; (610) 651-5847 Revision 15: 05/29/2018 Page 6 of 15 OMEMO I etc. & _ $wIFr RT®STARTER SHINGLE: Fastening: Use four nails, located as shown below 38-3/4° (984 mm) I jI+-1' (25 mm) from edge 1' (25 mm) from edge —.I 7-5/8° (194 mm) Maio 3° (76 mm) tThe inner two fasteners must be placed such that they fall i least 3' (76 mm) from the end joints of the shingle in the succeeding course. I 6.8 CT20'', ?(-r "; 25, XT ,M 30, XT'"' 30 I R: LOW AND STANDARD SLOPE STEEP SLOPE ENGLISH 12" 12" 12" Use four nails and six spots of asphalt roofing cement* for every full tl m) (305`mm) (305 mm) shingle (Figure 11-4). Asphalt oofing.cement meeting ASTM D4586 mm) Selant 1"(25 mm)� Type IL is suggested. 5 s/s" (145 mm1�2,,fanlorw METRIC h, 131/a" 131/8" — 131/e" Roofing Cement �+-1" (25 mm) — Sealant — 1" (25 mm) ►(' Apply 1"(25 mm) spots of asphalt roofing cement 1 1 under each tab corner. 61/e Figure11-1: Usefournails andsixspots ofasphaUcementonsteepslopes *CAUTIft Excessive use of roofing cement can cause shingles to blister. Figure 11:3. Usefournatisfor evMfrdl sbingle. 6.8.1 Hip & Ridee for MOW. XTT" 25. XTT"' 30. XTT' 30 IR: C (2b rn ) I I+ +I I -2" (50 mm) ,—Remove r t� I�E f —-Cap Cap Capnrn Shingle Shingle Shingle Figure 1124.• Cut labs, 'then tilt back to make cap shingles (Enghib dimensions sboum). 6.8.1.1 For ASTM D3161, Class F performance use BASF Flashing Sealant", in accordance with CertainTeed NEMO ETC, LLC Certificate of Authorization #32455 6T" EDITION (2017) FBC NOR CertainTeed Asphalt Roof Shi t Shingles lP •, - Figure 11-25.' Installation of caps along the hips and ridges: Mastic® NP1111" adhesive or Henkel "PL® Polyurethane Roof & irements. Evaluation Report 3532.09.05-1115 EVALUATION FL5444-R14 (610) 651-5847 Revision 15: 05/29/2018 Page 7 of 15 ONEM01-etc. 7M . LOWL AND STANDARD SLOPE STEEP SLOPE Use SIX nails for every full shingle located as shown below. Use SIX nails .md FOUR spots of asphalt roofing cement for every' full shingle as shown below Apply asphalt roofing cement 1"f25 mm) from edge of shingle. Asphalt roofing cement meeting ASTM D 4586 'l 'pe 11 is suggested. Nail Line Nail Nail Line 1'(25 mm) 1'(25 Figure 2: 11se six nailsfir even fill sbingle. 6.9.1 Hip & Ridge for Arcadia": Cedar Crest", Cedar Crest Use two (2), minimum 13/-inch long fasteners per sF side edge and about 2-inch up from the starter shin into the deck, or full penetration through the deck. from its exposed butt edge and 1-inch from each side For ASTM D3161, Class F performance use BASF "Son Flashing Sealant", in accordance with CertainTeed re( PL adhesive from the middle of the shingle's raised o% along the sides of the headlap along a line % to 1-inch apply the overlying shingle, gently pressing tab sides i apply a 1-inch diameter spot of NP 1 or PL adhesive b 203 mn1) (305 Mm) � l'suf$ Figure 3: Use sir nails rind four shots of asphalt roofing Cement oat steep slopes. M IR ngle. For the starter shingle, place fastener 1-inch from each e's exposed butt edge, ensuring minimum %-inch embedment or each full Cedar Crest shingle, place fasteners 8-5/8-inch up )[astic® 1\1121"" adhesive or Henkel "PL11 Polyurethane Roof & uirements, to hand -seal Cedar Crest shingles. Apply NP 1 or �rlay on the top piece and extending approximately 4-inch from each side of the shingle's headlap. Immediately align and Ito the adhesive, and install nails. To secure the other side, tween the shingle layers. Hand -sealing adhesive 4,' 114" 3/4" --► I+c-- 1" Dab of asphalt cement between 1„ shingle layers NEMO ETC, LLC Evaluation Report 3532.09.05-1135 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON- VHZ EVALUATION F1.5444-1114 CertainTeed Asphalt Roof Shin les; (610) 651-5847 Revision IS: OS/29/2018 Page 8 of 15 OMEMO I etc. 6 1O BELMONT®OAR IR BELMONT® Low and Standard Slope Steep Slope (greater than 21:12): (2:12 to 21:12): Use SEVEN nails and EIGHT spots of Use FIVE nails for every full Belmont shingl , asphalt roofing cement`" for every full located as shown below. Belmont shingle. Apply asphalt roofing f cement 1" (25mm) from edge of shingle. 53' 06 rrun9 19, 11010 104" Mod,1111 o Additional nails rl required. 1r� f` f9' {t5 See below. Asphalt roofing cement meeting ASTM D4586 Type II is suggested- 4 1 t12` (X MT, or IM ^+-1' (25 rr.ni 1' j25 rrm;� �rT — I XM)F 8 5rg' (220 r,R,1 1' (25 mm) Roofing C .gent 6.10.1 Hip & Ridge for Belmont® or Belmont® IR: 6.10.1.1 Option 1: For Belmont®, refer to instructions herein for Cedar CrestTM or Cedar Crest'"" IR hip and ridge shingles. For Belmont® IR, refer to instructions herein for Cedar C-estT,4 IR hip and ridge shingles. 6.10.1.2 Option 2: For Belmont®: Shangle® Ridge Figure 17-18' ShanRle' Ridge. 180 Exposure Remove tape from the right side 1 ° ; 8a and fasten SECOND Fasten the I left side 81/8" RIGHT FIRST ! LEFT Figure 17-19. nstallat1011 of SbangleO Ridge sbingles on helps and ridges. 6.10.1.3 For ASTM D3161, Class F performance use BASF "Sonolastic® NPiTM" adhesive or Henkel "PL11 Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed requirements. NEMO ETC, LLC Evaluation Report 3532.09.05-R15 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON- EVALUATION FL5444-R14 CertainTeed Asphalt Roof Shingles; (610) 651-5847 Revision 15: 05/29/2018 Page 9 of 15 6'.' 1. CARRIAGE HOUSE SHANGLE® AND GRAND MANOR'SHANGLE® WIDE NAMSIG AREA LOW AND STANDARD SLOPE Use five nails for every full Strangle. 5/8" (16 mm) PAIVIV 10 ;10& 1, ON 1� •-1., 1 (25 mm) 8 b/8" '220 mm) Figure 17-4.• Use fine nails for every fill Grand Aianor Shangle, Carriage House Shangle, or Centennial Slate hip and ridge shingles LANDMARK T'"j LANDMARKT"I111 LANDMARK'.".' LANDMARK*'" SOLARIs IR, LANDMARK*"' SOLARIS tY 14314' WA Nalling areas for low and standard slopes (from 2:12 to 21:12) Nall belwren upper & lower Ices as shrnvn above. MEMO ETC, LLC Certificate of Authorization #32455 ONEMOjetc. STEEP SLOPE Use seven nails. and three spots of asphalt roofing cement for every full Grand hfanor Shangle. Use five nails and three spots of asphalt roofing cement for every full Carriage House Shangle and Centennial Slate. Apply asphalt roofing cement 1" (25 mm) from edge of shingle (Figure 17-5). Asphalt roofing ceurent meeting ASTM D4586 Type I1 Is suggested 1" �—(25 mm.) (16 mm)+I 1 T (25 mm) 38 mm) or less 1. (�m) (220 mm) Figure 17 S: When installing Grand Manor Sbangles on steep slopes, use seuon nails and tbree spots of aspball roofing cement. Shangle: Refer to instructions herein for Shangle® Ridge rm PRO SOLARIsr LANDMARK TM PREMIUM, LANDMARKTm SOLARISr OR NORTHGATE: STEEP SLOPE NAILING AREA I 12" 14-3/4" 12" Nailing areas for steep slopes (greater than 21:12) and "Stoma -Nailing" Nail between lower 2 nail lines as shown above. 6T" EDITION (2017) FBC NOW rVHZ EVALUATION CertainTeed Asphalt Roof Shingles; (610) 651-5847 Evaluation Report 3532.09.05-R35 FL5444-R14 Revision 15: 05/29/2018 Page 10 of 15 6.12.1 6.12.1.1 Option 1: Shadow RidgeT"' or NothGate Accessory 12" (305mm) 6" 6" (150mm) (150mm) t Notch for Centering 12" .X / (305mm) Notches for Alignment to the Top Edge of the Previous 7 Cap for 5" (125mm) Exposure (1� m) . English Dimension Shadow Ridge- 9 27/32' y (260 mm) 415Pt6' (125 mm) :1 T 7 5/8" (194 mm) I NorthGate Ridge OMEMO I etc. 97/8" (25, rn) 415/16" 4t5/16' (125mm) (125mm) Notch for Centering 131/4, % (337mm) Notches for Alignment to the Top Edge of the Previous Cap for 55/8" (141,mm) Exposure Metric Dimension Shadow Ridge- 131181, d—(333 mm) —► -" 5/8-i-j- 6 5/8°-► _ i (168 mm) 168 mm i Centering 13 1/4" R Notch (337 mm) \ / t Align these 7 5/8" notches to top (194 mm) of edge of previous course. NorthGate Accessory 7 75/8„ (196inm) 12- (305rnaT) _Laying Notch I I I Figure 13-20: Use kon� notches to center shingles on hips and ridges, and to locate the correct exposure. 6.12.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic° NPJTI" adhesive or Henkel "PL® Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed requirements. 6.12.1.3 Option 2: Refer to instructions herein for Cedar Crest"', Cedar CreStTM IR hip and ridge shingles. NEMO ETC, LLC Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION CertainTeed Asphalt Roof Shingles; (610) 651-5847 Evaluation Report 3532.09.05-1135 FL5444-R14 Revision 15: 05/29/2018 Page 11 of 15 6.13 LANDMARK*" TL LANDMARK TL LANDMARK TL 131/2" 13" 131/2" Figure 13-4: Use four nails for evoy fill shingle. 6.14 PRESIDENTIAL SHAKE"", PRESIDENTIAL SHAKETM LR,'P LOW AND STANDARD SLOPE: For low and standard slopes, use five nails for each full shingle as shown below. — 40" --•I (10.16 mm) 51/4' I 1 I (133 mm) I • • . . • 141/4" 1 1/2' 38 mm) (362II mlh NOTE: Apply nails on painted guideline. Figure 16-6.• Fastening Fresik0al andPresldentiat TL Shake sbingles on low and standard slopes 6.14.1 Hip & Ridge for Presidential Shake'". Presidential SI 6.14.1.1 Option 1: Presidential Accessory PRESIDENTIAL ACCESSORY Presidential accessory shingles can be used for covert ridges. Apply shingles up to the ridge (expose no mor the bottom edge of the "tooth." Fasten each accessory tenors. The fasteners must be 13/4" long or_ longer, so either 3/4" into the deck or completely through the de accessory comes In two different sizes: Accessory produi Birmingham, AL is 12" x 12"; Portland, OR produces accessory. 6.14.1.2 For ASTM D3161, Class F performance use BASF "So Flashing Sealant", in accordance with CertainTeed re 6.14.1.3 Option 2: Refer to instructions herein for Cedar Cres MEMO ETC, LLC Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON• CertainTeed Asphalt Roof Shir ONEIVIO I etc. -131/2" &I o 13' 13112" (343 mm) 1 (330 mm) 043 mm) '--1125 mm) 1 "(25 mm)-►1 I Figure 13 Sr Use six nails and four spots of aspbalt roofing emnen t on steep slopes SHAKE TLTm, PRESIDENTIAL SOLARISTM: STEEP SLOPE: For steep slopes, use nine nails for each full Presidential shingle and apply 1" diameter spots of asphalt roofing cement under each shingle tab. After applying 5 nails in between the nailing guide lines, apply 4 nails 1" above tab cutouts maldng certain tabs of overlying shingle cover nails. 1' diameter asphalt roofing cement Figure 16-7; Fastening Presidentid and Presidential VL Shake shingles.on steep slopes. TM IR, Presidential Shake TL TM hips and than 7" from dth two fas, ley penetrate Presidential !d in /s q. x 131/4 lastic° NPJT""" adhesive or Henkel "PL® Polyurethane Roof & Arements. Cedar Crest"' IR hip and ridge shingles. Evaluation Report 3532.09.05-1135 HZ EVALUATION F1.5444-1114 !s; (610) 651-5847 Revision 15: 05/29/2018 Page 12 of 15 ONEMO I etc. I6.15 HATrms:"': LOW, STANDARD AND STEEP SLOPE: (230 mmM))(230 �—y.,—"_9 —` 9 I (230 (nin) (230 mm) (230 rnm) I 9..y��9.. �9.._. 9.. (230 (230 mm) mm) (230 mm) (230 mm) i t --(25 6m) _ _ _ (25 mm)-►� 9 3M" r+ (25 mm) — — (25 m_)-►I I (240 min) 93/8" Roofing Cement (2401 mm) Figure 15•4-- Fastening ttatteras sbingtes on steep slopes For steep slopes, use fire nails and eight spots of asphalt roofing Figure 15.3. Fastening tfallmas Shingles on cement for each full Hatteras shingle as shown above. Apply Y* (25mm) diameter spots of roofing cement (ASTM D 4586 Type 11 • Loin and Standard Slopes suggested) under each tab corner. Press shingle into place; do not For low and standard slopes, use fire nails for each full expose cement. Hatteras shingle as shown above. CAUTION: Too much roofing cement can cause shingles to blister. 6.15.1 Hip & Ridge for HatteraSTM: 6.15.1.1 Option 1: Accessory for Hatteras Figure 15-14.• 18 Wee -piece units separate to make 54 Hatteras Accessory shingles. 6.15.1.2 Option 2: Cut Hatteras Shingles ,(230 mm) I I t (203.m�'ll -- ------ -- 460mm') Cap Cap Cap Cap Shingle Shingle Shingle -Shingle NIP) I \ Figure 15-20: Cutffatteras sbingles to make cover cap. F(qure 15-21: Installation of caps along hips and ridges, 6.15.1.3 For ASTM D3161, Class F performance use BASF "Sonolastic® NP1"' adhesive or Henkel "PL® Polyurethane Roof & Flashing Sealant", in accordance with CertainTeed rIpquirements. NEMO ETC, LLC Evaluation Report 3532.09.05-R15 Certificate ojAuthorization #32455 6T" EDITION (2017) FBC NOf�-HVHZ EVALUATION FL5444-R14 CertainTeed Asphalt Roof Sh�ngles; (610) 651-5847 Revision 15: 05/29/2018 Page 13 of 15 ONEMO I etc. 6.16 HIGHLAND SLATET11 ',HIGHLAND SLATE""" IR:? LOW AND STANDARD SLOPE: STEEP SLOPE Use FIU nails"and EIGHT spots of.asphaltroofing cement* for each R mrr� (730mm} (2�Ortm) :(230mm) full Highland Slate shingle, For Miami -Dade, SIX naffs are:required. Apply 1" diameter spots of asphalt roofing cement under each tab corner. Asphalt roofing cement meeting ASTM D4586 Type II Is suggested. ('d%Vv (25 Miami -Dade requires SIX nails (two nails installed over center cutout as shown). Figure II 3: Use FIVE nails for every Highland Slate or Shangle RidgeT' hip and ridge shingles. Miami -Dade requires SIX nails (two nails installed over center ailout as shown} Figure 113A. Use Hff nails and eigbi spots of aspbalt roofing cement tinder eacb tab corner. *CAUTION: Excessive use of roofing cement can cause shingles to blister. Refer to instructions herein for Cedar Crest", Cedar CrestTM IR 6.17 PATRIOT*": LOW AND STANDARD SLOPE STEEP SLOPE Use FOUR nails for every full shingle located a5 shown below. Use POUR nails and four spots of asphalt roofing cement for every full shingle as shown beloiv. Asphalt roofing cement meeting ABTM D4586 1,pe 11 is suggested. Apply 1"(25 mm) spots of asphalt roofing Sealant cement as shown. _ _ CAUTION: Excessive use of roofing cement can cause shingles to blister. �_ EtJB I, (25 mm) — — — — — — V (25mm}_ (156 mm) i i I+ 13-119' -►r— 13-1t8' ►I+ 13.118 — — — — — -n133imm) I mml (m) 2m}= 6/8'�»1'(25mm) 1 (156mm) I • r� O Raollnp Cement 12-10 --�— 13-', -.-�— 12-18 rAmm) (aiimm) A.) 6.17.1 Hip & Ridge for Patriot*": Refer to instructions herein for Cedar Crest*"", Cedar Crest*"' III, Shadow Ridge""", NorthGate or Shangle Ridge" hip and ridge shingles. NEMO ETC, LLC Certificate of Authorization #32455 6"" EDITION (2017) FBC NOW HVHZ EVALUATION CertainTeed Asphalt Roof Shingles; (610) 651-5847 Evaluation Report 3532.09.05-Ri5 FL5444-R14 Revision IS: 05/29/2018 Page 14 of 15 7.1 Each unit shall bear a permanent label with the manuf; Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with / 11905.2.6.1. ONEMO I etc. urer's name, logo, city; state and logo of the Accredited Quality ie of the required classifications detailed in FBC Table 1507.2.7.1 As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for information on which requirements. produce products covered by Florida Rule 61G20-3 CA UL LLC— QUA9625; (414) 248-6409; karen.buchmann@us.bi.com - END OF EVALUATION REPORT - NEMO ETC, LLC Certificate of Authorization rY32455 6T" EDITION (2017) FBC N CertainTeed Asphalt Roof Evaluation Report 3532.09.05-1115 EVALUATION FL5444-1114 (610) 651-5847 Revision 15: 05/29/2018 Page 15 of 15