DEPARTMENT OF REGULATORY AND ECONOMIC
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE I
CertainTeed Corporation
20 Moores Road
Malvern, PA 19355
SCOPE:
This NOA is being issued under the applicable rules and reguh
documentation submitted has been reviewed and accepted by h
used in Miami Dade County and other areas where allowed by
This NOA shall not be valid after the expiration date stated t
(In Miami Dade County) and/or the AHJ (in areas other than
product or material tested for quality assurance purposes. If t
manner, the manufacturer will incur the expense of such test
suspend the use of such product or material within their juris
if it is determined by Miami -Dade County Product Control S
requirements of the applicable building code.
This product is approved as described herein, and has been d
including the High Velocity Hurricane Zone of the Florida B
DESCRIPTION: CertainTeed Underlayment Systems
LABELING: Each unit shall bear a permanent label with the
statement: "Miami -Dade County Product Control Approved",
RENEWAL of this NOA shall be considered after a renewal
in the applicable building code negatively affecting the perfor
TERMINATION of this NOA will occur after the expiration
materials, use, and/or manufacture of the product or process. N
for sales, advertising or any other purposes shall automatically
of this NOA shall be cause for termination and removal of NO,
RecENEO
NOV 0:6 2018 MIAMI-DADE COUNTY
Pe""l l PRODUCT CONTROL SECTION
(RER) Sr. Lu /e ColIn rent 11805 SW '26 Street, Room 208
h' Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
WWW.miamidade.gov/economy
is governing the use of construction materials. The
ni-Dade County RER - Product Control Section to be
Authority Having Jurisdiction (AHJ):
w. The Miami -Dade County Product Control Section
ami Dade County) reserve the right to have this
product or material fails to perform in the accepted
and the AHJ may immediately revoke, modify, or
tion. RER reserves the right to revoke this acceptance,
.on that this product or material fails to meet the
to comply with the Florida Building Code
Code.
name or logo, city, state and following
otherwise noted herein.
lication has been filed and there has been no change
.ce of this product.
or if there has been a revision or change in the
of this NOA as an endorsement of any product,
inate this NOA. Failure to comply with any section
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided
shall be available for inspection at the job site at the request o
This NOA revises NOA# 14-1028.02 and consists of pages 1
The submitted documentation was reviewed by Alex Tigera.
MIAMI•DADE COUNTY
the user by the manufacturer or its distributors and
Building Official.
U
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 1 of 9
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS
SCOPE:
This approves CertainTeed Underlayment Systems, as de
the Florida Building Code including the High Velocity H
TRADE NAMES OF PRODUCTS MANUFACTURED C
Product Dimensions Test
WinterGuard HT
Manufuring
Location #1
WinterGuard Granular
Manufuring
Location #2
WinterGuard Sand
Manufuring
Location #2
Diamond Deck"
Manufuring
Location #3& 4
MetaLaymenf"
Manufuring
Location #1
Black Diamond"'
Base Sheet
Manufuring
Location #2
36" x 65' ASTM D
rolls
in this Notice of Acceptance; designed to comply with
Zone of the Florida Building Code.
LABELED BY APPLICANT:
Product
in Description
70 Modified fiberglass reinforced, bituminous sheet
material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
36" x 65'
ASTM D 1970
Granular surfaced modified, fiberglass reinforced,
rolls
bituminous sheet material for use as an
underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
36" x 65'
ASTM D 1
70
Embedded sand surfaced modified, fiberglass
rolls
reinforced, bituminous sheet material for use as an
underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
48" x 250'
ASTM D 226
Synthetic, scrim reinforced underlayment for use
rolls
Type H
under shake, shingles, slate or metal roofing.
39 3/8" x 61' ASTM D 1970 A film surfaced, self -adhering underlayment for
rolls use under metal roofing.
39 3/a" x 68' 7" ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
rolls bituminous sheet material for use as an
underlayment in sloped roof assemblies.
Designed as an ice & rain shield. Not for use as
an Anchor Sheet. Direct adhesion to wood deck
not permitted in the HVHZ.
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 2 of 9
✓ t
TRADE NAMES OF PRODUCTS MANUFACTURED OR
LABELED BY APPLICANT:
Product
Dimensions
Test
Product
Specification
Description
Flintlastic GTA
39 s/a" x 32' 10"
ASTM D 6222
Granule surfaced APP Modified Bitumen
Manufuring
rolls
Grade G
membrane with non -woven polyester mat
Location #1
Type I
reinforcement for torch application.
All Weather/Empire
39 3/8" x 65' 10"
ASTM D
601
Asphalt coated fiberglass reinforced base sheet.
Base Sheet
rolls
Type II
Manufuring
Location #1
Flintlastic GMS
39-3/8" x 32' 10"
ASTM D 6
164
Granule surfaced SBS Modified Bitumen
Manufuring
rolls
Grade G
membrane with non -woven polyester mat
Location #1
Type I
reinforcement for mop application.
Flintlastic SA Cap
39 s/a" x 33' 11"
TAS 103
Polyester reinforced, self -adhering SBS modified
Manufacturing
rolls
bitumen cap sheet.
Location #1
Roofers' Select
36" x 144' rolls
ASTM D226
An asphalt -impregnated, organic felt reinforced
Manufacturing
Type I
with glass fibers, roofing underlayment.
Location #5
RoofRunner
48" x 250 rolls
ASTM D226
Synthetic, scrim reinforced underlayment for use
Manufacturing
Typell
under asphalt shingles.
Location #6
MANUFACTURING LOCATION:
1. Little Rock, AR.
2. Shakopee, MN
3. Hangzhou, China
4. Silvassa, India
5. Shreveport, LA
6. Vapi, India
NOA No.: 17-0306.07
QM1 �aoe couNTtr Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 3 of 9
EVIDENCE SUBMITTED:
Test Agency
Momentum Technologies, Inc.
TrinitylERD
PRI Construction Materials
Technologies, LLC
InterTek Testing Services Ltd.
QAI Laboratories
AX31 G8G
3530.12.05-1-R1
C30280.12.09-R2
C32240.03.10�
C30890.03.10-�
C3500.04.10
C31860.05.10�
C40050:09.12-2
i
C31410.10.10-R1
C45240.01.14-I
C32930.01.11-R2
C45240.01.14-
CTR-SC 11145.16 3A
CTR-SC11415.11.16
CTR-SC11505.1 -.16
ACT -SC 14110.06.17-1
CTC-093-02-0
CTC-163-02-0
10103165000Q-0IO2C
101227796COQ-003C
10103165000O-005C
RJ3334-2
RJ3502-1
Test Name/Report
ASTM D6222
ASTM D1623
ASTM D226
ASTM D4977
ASTM D 1970
TAS 103
ASTM D1623
ASTM D 1970
ASTM D5147. ASTM D4798
ASTM D1970, TAS 110
ASTM D1623
TAS 103, TAS 110
ASTM D4601
TAS 103
ASTM D 1623
ASTM D 226
ASTM D6164, ASTM D4798
ASTM D6757, ASTM D226,
ASTM D4869
ASTM D226
ASTM D4798
ASTM D4869
ASTM D226
ASTM E108
Date
06/05/09
10/05/09
12/11/09
03/04/10
03/17/10
04/01/10
05/18/10
09/28/12
11/02/12
01/15/14
01/20/14
01/24/14
09/19/16
11/28/16
12/22/16
06/29/17
08/09/11
05/09/13
08/13/13
08/13/13
08/13/13
07/07/14
09/29/14
NOA No.: 17-0306.07
MIAMI•DAD; COUNTY Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 4 of 9
APPROVED ASSEMBLIES:
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) One or more plies of Diamond Deck with a minimum 4" headlap and a 6" end
lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge
and in a grid pattern spaced 12" o.c. in the field of the roll.
(2:12 to < 4:12) One or more plies of Diamond Deck with a minimum 20" headlap and a 12"
end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o. . in the field of the roll. Vertical joints should be offset
36" minimum.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) a single layer of Roofl�unner shall be applied with printed side up, parallel to
the eaves, overlapping each course witha minimum 3" headlap and a 6" end lap mechanically
fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and spaced 15" o.c.
vertically and 12" o.c. horizontally in the field of the roll.
Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with
applicable Roofing Application Standar�s and Building Codes
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 5 of 9
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to E
Anchor Sheet: (4:12 or Above) Two plies of Roofers' I�
mechanically fastened to deck with apprc
in a grid pattern spaced 12" o.c. in the fi,e
Surfacing:
Deck Type 1:
Deck Description:
System E(4):
ct with a minimum 2" headlap and a 6" end lap
d nails and tin caps 6" o.c. at the side lap edge and
of the roll.
(2:12 to < 4:12) Two plies of Roofers' Select with a minimum 19" headlap and a 12" end lap
mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and
in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset 72"
minimum.
Shall be acceptable for use in approved 'asphaltic shingle applications. Must Comply with
applicable Roofing Application Standards and Building Codes
Wood, Non -insulated
19/32" or greater plywood or wood plank
Anchor sheet mechanically fastened to
membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Flintlastic GTA to Ich applied to anchor sheet or WinterGuard HT,
WinterGuard Granular, WinterGuard Sand, MetaLayment or Black Diamond Base Sheet self -
adhering membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap.
Place the first course of membrane parallel to the eave, rolling the membrane to obtain
maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the membrane is acceptable. If membrane is strapped, then anchor sheet must also
be strapped.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes
NOA No.: 17-0306.07
QM1AM-DAffiEC=0UN Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 6 of 9
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(5): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One ply of ASTM D 226 Type II organic felt or All Weather/Empire Base mechanically
attached with a minimum 4" side lap and a minimum 6" end lap. Anchor sheet shall be applied
at a right angle (900) to the slope of the deck with approved annular ring shank nails and tin
caps at a fastener spacing of 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in
the field of the roll of the base sheet.
Ply Sheet: (Optional) One or more plies of an E
approved asphalt applied within the
Membrane: One ply of Flintlastic GMS adhered in
EVT range and at a rate of 20-40 lbs./sc
or Flintlastic SA Cap, self -adhering mej
4" side lap and 6" end lap. Place the fir:
membrane to obtain maximum contact.
applied. Vertical strapping of the meml
anchor sheet and ply sheet must also be
D226 ply sheet adhered in a full mopping of
range and at a rate of 20-40 lbs./sq.
full mopping of Type IV asphalt applied within the
or Flintlastic GTA torch applied tothe preceding sheet
ibranes adhered to the preceding sheet with a minimum
course of membrane parallel to the eave, rolling the
Remove the release membrane as the membrane is
rane is acceptable. If membrane is strapped, then
When used in Tile roof systems the cap Csheet shall be back nailed to deck with approved
annular ring shank nails and tin caps at a maximum of 12" o.c. at the side laps and 6" o.c. at the
end laps. No nails or tin caps shall be exposed.
Surfacing: •Flintlastic SA Cap, Flintlastic GTA
tile system mechanically fastened as
•Flintlastic SA Cap, Flintlastic GTA
tile system adhered as specified in tl
having a current tile adhesive NOA
Must comply with appropriate Roofing
applicable Building Codes.
Flintlastic GMS may be used with any approved roof
cified in their current NOA.
Flintlastic GMS may be used with any approved roof
current NOA using any foam adhesive listed and
Standard RAS 118, RAS 119, RAS 120 and
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,
state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
MIAMI•DADE COUNTY
;@
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 7 of 9
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by cop
1. This Notice of Acceptance.
2. Any other documents required by the Building Official
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. CertainTeed underlayment roofing systems utilizing Flin
WinterGuard Sand, DiamondDeck, MetaLayment or B12
acceptable for use in asphaltic shingles, wood shakes,
CertainTeed underlayment roofing systems utilizing Roof,
asphaltic shingles.
3. CertainTeed underlayment roofing systems utilizing Flint
cap membrane shall be acceptable for use in foam adhe
specified in the surfacing option of the approved assemblie
4. This acceptance is for prepared roofing applications. M
applicable building code. CertainTeed underlayment roof
applicable Building Code.
5. CertainTeed underlayment roofing systems membranes st
deck free of irregularities.
of the following:
applicable building code in order to properly evaluate
;tic GTA, WinterGuard HT, WinterGuard Granular,
Diamond Base Sheet as a cap membrane shall be
shingles, quarry slate, and metal roof applications.
mer or Roofers' Select shall be acceptable for use in
SA Cap, Flintlastic GTA or Flintlastic GMS as a
set and mechanically fastened roof tile systems as
ium deck requirements shall be in compliance with
systems shall be installed in strict compliance with
be applied to a smooth, clean and dry surface with
6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a
recover system but may be applied over an approved roofing Base/Anchor sheet underlayment.
7. WinterGuard HT, WinterGuard Granular, WinterGuard
MetaLayment, Diamond Deck, Flintlastic GMS, and Flint'
for longer than 180 days of application. RoofRunner and
roof for longer than 30 days after application.
8. CertainTeed underlayment products may be used with ar
CertainTeed underlayment products as a component p�
CertainTeed underlayment products are not listed, a regi
(AHJ) or Miami -Dade County Product Control for approi
to detail compatibility of the products, wind uplift resistant
9. All nails in the deck shall be carefully checked for protruc
the deck thoroughly to remove any dust and debris prior to
nd, Black Diamond Base Sheet, Flintlastic SA Cap,
tic GTA shall not be left exposed as a temporary roof
iofers' Select shall not be left exposed as a temporary
approved roof covering Notice of Acceptance listing
of an assembly in the Notice of Acceptance. If
I may be made to the Authority Having Jurisdiction
provided that appropriate documentation is provided
and fire testing results.
�g heads. Re -fasten any loose decking panels. Sweep
10. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions.
11. Roll or broom the entire membrane surface so as to have 1
overlap areas.
12. Flash vent pipes, stacks, chimneys and penetrations in cc
Notice of Acceptance and applicable Building Code.
contact with the surface, giving special attention to
with Roof Assembly current Product Control
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 8 of 9
o
13. The maximum roof slope for use as roof tile underlayment for direct -to -deck tile assemblies shall be as follows:
(Limitations noted below are a result of the tile stacking/tile loading performance and do not reflect to that of the
underlayment. See Table Below)
Tile Profile
Flintlastic GMS'
Flintlastic SA Cap'
Flintlastic GTA'
Flat Tile
4:12
6:12
6:12
Profiled Tile
4:12
5:12
6:12
'The following is applicable to all systems using and Flint
•Slopes greater than 4:12 — Horizontal batten strips ar
maximum of 10 tiles shall be stacked parallel to tt
2The following is applicable to all systems using Flintlasti
•Slopes up to 5:12, Profiled Tile — Stage by placing tv
four tiles on top parallel to the slope for a total of
*Slopes greater than those shown in the above table —
horizontal battens; a maximum of 10 tiles shall be
'The following is applicable to all systems using Flintlasti
•Tiles shall be stored on battens on roof pitches greate
Front View
Figure 1: Staged Method,
stic GMS:
required. Stage tiles touching horizontal battens; a
slope (See Figure 2 below).
SA Cap:
tiles perpendicular to the slope followed by maximum
tiles. (Illustrated in Figure 1 below).
orizontal batten strips are required. Stage tiles touching
tacked parallel to the slope (See Figure 2 below).
GTA:
than 6:12".
Front
View
Figure 2: Batten Method
END OF THIS ACCEPTANCE
Side View
Figure 2: Batten Method
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 9 of 9