One layer s/a" type X I
angles to each side
shank, 'f/a" heads,
Joints staggered 24" c
AND INTERIOR PARTITIONS, WOOD FRAMED
3510
GYPSUM WALLBOARD, WOOD STUDS
psum wallboard or gypsum veneer base applied parallel or at right
of 2 x 4 wood studs 24" o.c. with 6d coated nails, 177s" long, 0.0916'
O.C.
i opposite sides. (LOAD -BEARING)
1 HOUR I 35 to, 39 STC
FIRE SOUND
HAN
Thickness: 47/8"
Approx. Weight: 7 psf
Fire Test: UL R3501-47, 48, 9-17-65,
UL Design U309;
UL R1319-129, 7-22-70,
--),UL Design U314
Sound Test: NGC 2404, 10-14-70
Digitally s
Carmelo by Carme
Gintoli
Gintoli Date: 202
14:3 0:5 7 —
Description of work:
1,264 square feet new tenant build -out, in an existing
building. Build -out to be used as a Latin Market.
Florida Fire Prevention Note:
Project is un-protected. There is no sprinkler system.
Modifications to alarm system are to be done by a licensed
alarm sub -contractor under a separate permit.
Exterior rating of all rated assemblies shall be maintained
during construction.
Exit Signage to comply FFPC 101.7.9
Emergency Lighting to comply with FFPC 101.7.9
FIRE EXTINGUISHERS
Shall be provided by local fire safety company and most
requirements of NFPA 10
Contractor to coordinate final approval of Class. number,
location and spacing of fire extinguishers with field
Inspector.
GENERAL NOTES:
The Contractor shall review these documents for accuracy
and interpretation. Any discrepancies shall be brought to the
attention of the Architect prior to ordering materials or
beginning construction.
The Contractor shall verify all details and dimensions prior to
beginning construction.
Code Inform lion Petall 5 ace
Level of Alteration - Level 2
Work Area compliance WtW
ccupar p: Cha lqe from l3 to M
Chapter 3 5ec, 309 F13C M-Mercantile
onstruction Tripe: Chapter 6, 602.5 f4pe V--13 Ur-5prinHed;
Area: Chapter 5; table 5�06,2; V-6 90005f Allowed; 12225f provided
ccuparrt Load:
Table 1004,1.2 : Mercantile 605f/ person
1222 sf/ 60 - 21 persons max
press Calculations:
1006.1,2
Less than 30 Occupants One Exit Peguired; 3 provided
Life Safety 1215-tance of Travel:
200 Mowed; provided
o►let CAculation: 403,1 & 4032
FPC 403,2 Exception 3: 5eparate facilities not required for Mercantile
Occupancies less than 100 Occupant.
I WC & I LAV.1-5EWICE 51NK PPOVIM19
AVA cornpliant Toilet kom
ce%,&1 ty Code:
2020 Florida Accessibility Code 5ixth Edition
ddinq Code Pata:
2020 Florida Existing Buildings Code, 51xth Edition
2020 Florida Building Code, Sixth Edition
2020 Florida Fire Prevention Code, FAC69A-60-005
2020 Florida Mechanical Code, 5ixth Edition
2020 Florida Plumbinq Code, Sixth Edith,
2020 Florida Life 5afettl Code
2020 Florida Electrical Code, Sixth Edition
PEVIEW AN12 APPPOVAL BY LOCAL ANJ SHALL NOT MLIEVE THE APPLICAW OF ff
f5PON51BILTIE5 OF COMPLIANCE WTN FFPC-1-1-14-I