Loading...
HomeMy WebLinkAboutEnergy CodeEnergy Code & Load Calc Package 17650 Orange FORM R405-2020 Ecolnnovative 772-501-0152 slab RESIDENTIAL ENERGY CONSERVATION Florida Department of Business at Simulated Performance Alternatil Applications for compliance with the 2020 Florida Build, Residential Simulated Performance Alternative shall inc ❑ This checklist i ❑ Form R405-2020 report rr ❑ Input summary checklist that can be used for field v ❑ Energy Performance Level (EPL) Display Card (on( ❑ HVAC system sizing and selection based on ACCA ❑ Mandatory Requirements (five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Componen ❑ A completed 2020 Envelope Leakage Test Repq allows dwelling units of R-2 Occupancies and mF comply with Section C402.5 ❑ If Form R405 duct leakage type indicates anyth 2020 Duct Leakage Test. Report - Performance 1 /f 4/6/2021 7:07:45 PM DE DOCUMENTATION CHECKLIST RECEMID Professional Regulation MAY`2 t 2021 (Performance) Method Permitting Department St. Lucie County Code, Energy Conservation via the page) (usually four pages/may be greater) S or per exceptions provided in Section R403.7 Criteria checklist (Table R402.4.1.1- one page) ,t (usually one page); exception in R402.4 Itiple attached single family dwellings to other than "default leakage" then a completed thod (usually one page) EnergyGaugeO USA 7.0.00 - FlaRes2020 FBO 7th Edition (2020) Compliant Software Page 1 of 1 April 6, 2021 1 Energy Code & Load Calc Package 17650 Orange Avenul Revised Ecolnnovative 772-501-0152 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional R gulation - Residential Performance Method . Project Name: Orange Ave_Revised_Martinez 2021 BJilder Name: Cesar Martinez Street: 17650 Orange Ave P rmit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34945 P rmit Number. Owner. Cesar and Marcela Martinez Ju 'sdiction: St Lucie County Design Location: FL, Fort Pierce C unty: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 1 . Wall Type$2946.2 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2570.20 ft2 b. Frame - Wood, Adjacent R=13.0 376.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 1 . Ceiling Types (3342.8 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=29.0 3342.80 ft2 6. Conditioned floor area a=Ave grade (ft2) 3037 b. N/A R= ft2 Conditioned floor area glow grade (ft2) 0 c. N/A R= ft2 7. Windows(340.2 sqft.) Description Area 1 . Ducts R ft2 a. Sup: Attic, Ret: Pantry, AH: Pantry 6 328 a. U-Factor: Dbl, U=0.58 143.61 ft2 SHGC: SHGC=0.17 b. U-Factor: Dbl, U=0.62 69.67 ft2 1 . Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.16 a. Central Unit 44.5 SEER:16.00 c. U-Factor: Dbl, U=0.58 11.59 ft2 SHGC: SHGC=0.71 Area Weighted Average Overhang Depth: 7.071 ft. 1 . Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.366 a. Electric Strip Heat 31.4 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 1 . Hot water systems SHGC(AVG): NIA a. Electric Cap: 40 gallons 9. Floor Types (3037.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 3037.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 1P. Credits None Glass/Floor Area: 0.112 Total Proposed Modified Loids: 90.16 PASS Total Baseline Loa s: 90.71 I hereby certify that the plans and specifications covered by R view of the plans and ,01E ST.q?, this calculation are in compliance with the Florida Energy sp cifications covered by this �+�� Code. ca culation indicates compliance wi h the Florida Energy Code. Ir nrrr �•. ��� .:: ::; . �ti O PREPARED BY: B fore construction is completed DATE: April 6. 2021 thi building will be inspected for O �, co pliance with Section 553.908 I hereby certify that this building, as designed, is in compliance a Statutes.with the Florida Energy Code.OWNER/AGg ZDING T: OFFICIAL: DATE: / DATE: - Compliance requires certification by the air handler unit manufac certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Chei envelope leakage test report with envelope leakage no greater than i that the air handler enclosure qualifies as list in accordance with R402.4.1.1 and this project requires an 10 ACH50 (R402.4.1.2). 4/6/2021 7:07 PM 7.0.00 - FlaRes202O FBC 7th (2020) Compliant Software Page 1 of 7 April 6, 2021 Energy Code & Load Calc Package 1.7650 Orange Avenu _Revised Ecolnnovative 772-501-0152 lrnPRn Rangy -gran INPUT-RUMMARY CHECKLIST REPORT PROJEC Title: Orange Ave_Revised Martine Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3 37 Lot # Owner Name: Cesar and Marcela Martinez Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: N PlatBook: Builder Name: Cesar Martinez Rotate Angle: 0 Street: 17650 Orange Ave Permit Office: St. Lucie County Cross Ventilation: County: St. Lucie Jurisdiction: St Lucie County Whole House Fan: City, State, Zip: Fort Pierce , Family Type: Detached FL, 34945 New/Existing: New (From Plans) Comment: CLIMAT Des i n Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 0 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCK Number Name Area Volume 1 Block1 3037 34195 SPACE Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Foyer 105 1365 No 0 1 Yes Yes Yes 2 Dining Room 215 2795 No 1 0 1 Yes Yes Yes 3 Bathroom 2 49 490 No 0 .0 1 Yes Yes , Yes 4 WIC 4 50 500 No 0 0 1 Yes Yes Yes 5 Bedroom 4 187 1870 No 0 1 1 Yes Yes Yes li Pantry 128 1280 No 0 0 1 Yes Yes Yes 7 Bedroom 3• 197 1970 No 0 1 1 Yes Yes Yes 8 WIC 3 61 610 No 0 0 1 Yes Yes Yes 9 Bedroom 2 201 2010 No 0 1 1 Yes Yes Yes 10 WIC 2 48 480 No 0 0 1 Yes Yes Yes 11 Bathroom 3 57 570 No 0 0 1 Yes Yes Yes 12 Kitchen 309 4017 Yes 1 0 1 Yes Yes Yes 13 Great Room 517 6721 No 1 0 1 Yes Yes Yes 14 Master Bedroom 365 3650 No 1 1 1 Yes Yes Yes 15 WIC 140 1400 No 0 0 1 Yes Yes Yes 16 Master Bathroom 279 2790 No 0 0 1 Yes Yes Yes 17 Office 129 1677 No 1 0 1 Yes Yes Yes 4/6/2021 7:07 PM 7.0.00 - FlaRes202O FBC 7th (2020) Compliant Software Page 2 of 7 April 6, 2021 Energy Code ✓f< Load Calc Package 17650 Orange Avenu _Revised Ecolnnovative 772-501-0152 FORM R405-2020 INPUT SUMMARY CHECK IST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Foyer 8.5 ft 0 105 ft2 ___ 1 0 0 2 Slab -On -Grade Edge Insulatio Dining Room 15 ft 0 215 ft2 ___ 1 0 0 3 Slab -On -Grade Edge Insulatio Bathroom 2 loft 0 49 ft2 ___ 1 0 0 4 Slab -On -Grade Edge Insulatio WIC 4 7.8 ft 0 50 ft2 1 0 0 5 Slab -On -Grade Edge Insulatio Bedroom 4 35.5 ft 0 187 ft2 ___ 1 0 0 6 Slab -On -Grade Edge Insulatio Pantry 8.3 ft 0 128 ft2 1 0 0 7 Slab -On -Grade Edge Insulatio Bedroom 3 12.8 ft 0 197 ft2 ___ 1 0 0 8 Slab -On -Grade Edge Insulatio WIC 3 6.7 ft 0 61 ft2 s_ 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 2 28.5 ft 0 201 ft2 1 0 0 10Slab-On-Grade Edge Insulatio WIC 2 13.9 ft 0 48 ft2 r_ 1 0 0 11Slab-On-Grade Edge Insulatio Bathroom 3 8.5 ft 0 57 ft2 e_ 1 0 0 12Slab-On-Grade Edge Insulatio Kitchen 6 ft 0 309 ft2 1 0 0 13Slab-On-Grade Edge Insulatio Great Room 23 ft 0 517 ft2 ___ 1 0 0 14SIab-On-Grade Edge Insulatio Master Bedroom 39 ft 0 365 ft2 1 0 0 15Slab-On-Grade Edge Insulatio WIC 8.3 ft 0 140 ft2 ___ 1 0 0 16Slab-On-Grade Edge Insulatio Master Bathroom 45.5 ft 0 279 ft2 ___ 1 0 0 17SIab-On-Grade Edge Insulatio Office 9.9 ft 0 129 ft2 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3396 ft2 0 ft2 I Light N 0.6 No 0.9 No 29 26.57 ATTIC V/ # Type Ventilation Vent Ratio 1 in) Area RBS IRCC 1 Full attic Unvented 0 3037 ft2 N Y 4/6/2021 7:07 PM 7.0.00 - FlaRes202O FBC 7th Editioh (2020) Compliant Software Page 3 of 7 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenue Revised Ecolnnovative 772-501-0152 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING. # Ceiling Type Space R Value Ins Type Area .Framing Frac Truss Type 1 Under Attic (Unvented) Foyer 0 Blown 150 ft2 0.11 Wood 2 Under Attic (Unvented) Dining Room 0 Blown 261.5 ft2 0.11 Wood 3 Under Attic (Unvented) Bathroom 2. 0 Blown 49 ft2 0.11 Wood 4 Under Attic (Unvented) WIC 4 0 Blown 50 ft2 0.11 Wood 5 Under Attic (Unvented) Bedroom 4 0 Blown 187 ft2 0.11 Wood 6 Under Attic (Unvented) Pantry 0 Blown 128 ft2 0.11 Wood 7 Under Attic (Unvented) Bedroom 3 0 Blown 197 ft2 0.11 Wood 8 Under Attic (Unvented) WIC 3 0 Blown 61 ft2 0.11 Wood 9 Under Attic (Unvented) Bedroom 2 0 Blown 201 ft2 0.11 Wood 10 Under Attic (Unvented) WIC 2 0 Blown 48 ft2 0.11 Wood 11 Under Attic (Unvented) Bathroom 3 0 Blown 57 ft2 0.11 Wood 12 Under Attic (Unvented) Kitchen 0 Blown ' 353 ft2 0.11 Wood 13 Under Attic (Unvented) Great Room 0 Blown 594 ft2 0.11 Wood 14 Under Attic (Unvented) Master Bedroom 0 Blown 411 ft2 0.11 Wood 15 Under Attic (Unvented) WIC 0 Blown 140 ft2 0.11 Wood 16 Under Attic (Unvented) Master Bathroom 0 Blown 279 ft2 0.11 Wood 17 Under Attic (Unvented) Office 0 Blown 176.3 ft2 0.11 Wood WALL Adjacent Cavity AA idth Height Sheathing Framing Solar Below Space 1 S Exterior Concrete Block - Int Insul Foyer 4.0999 8 5 13 109.4 ft2 0 0.75 0 2 S Exterior Concrete Block - Int InsdDining Room 4.0999 8 9 13 113.8 ft2 0 0.75 0 _ 3 E Garage Frame - Wood Dining Room 13 2 0 13 26.0 ft2 0.23 0.75 0 _ 4 S Garage Frame - Wood Dining Room 13 3 9 10 37.5 ft2 0.23 0.75 0 _ 5 W Garage Frame - Wood Bathroom 2 13 4 2 10 41.7 ft2 0.23 6.76 0 6 S Garage Frame - Wood Bathroom 2 13 5 9 10 57.5 ft2 0.23 0.75 0 _ 7 S Garage Frame - Wood WIC 4 13 10 10 78.3 ft2 0.23 0.75 0 _ 8 S Garage Frame - Wood Bedroom 4 13 1 6 10 135.0 ft2 0.23 0.75 0 9 W Exterior Concrete Block - Int InsuiBedroom 4 4.0999 1 10 10 128.3 ft2 0 0.75 0 10 N Exterior Concrete Block - Int InsuBedroom 4 4.0999 E 0 10 90.0 ft2 0 0.75 0 _ 11 W Exterior Concrete Block - Int Insul Pantry 4.0999 2 10 81.7 ft2 0 0.75 0 12 W Exterior Concrete Block - Int InsuBedroom 3 4.0999 12 10 10 128.3 ft2 0 0.75. 0 13 W Exterior Concrete Block L. Int Insul WIC 3 4.0999 E 6 10 65.0 ft2 0 0.75 0 14 W Exterior Concrete Block - Int InsuBedroom 2 4.0999 1 10 10 128.3 ft2 0 0.75 0 _ 15 N Exterior Concrete Block _ Int InsuBedroom 2 4.0999 15 8 10 156.7 ft2 0 0.75 0 _ 16 N Exterior Concrete Block - Int Insul WIC 2 4.09959 III 8 10 66.7 ft2 0 0.75 0 17 E Exterior Concrete Block - Int Insul WIC 2 4.0999 7 2 10 71.7 ft2 0 0.75 0 _ _ 18 E Exterior Concrete Block - Int InsuBathroom 3 4.0999 8I 6 10 85.0 ft2 0 0.75 0 _ 19 E Exterior Concrete Block - Int Insul Kitchen 4.0999 1 4 10 13.3 ft2 0 0.75 0 _ 20 N Exterior Concrete Block - Int Insul Kitchen 4.0999 8 10 46.7 ft2 0 0.75 0 _ 21 N Exterior Concrete Block - Int InsLGreat Room 4.0999 22 11 10 229,2 ft2 0 0.75 0 22 N Exterior Concrete Block - Int Instllaster Bedro 4.0999 16 10 10 168.3 ft2 0 0.75 0 23 E Exterior Concrete Block - Int InsWaster Bedro 4.0999 2 2 10 221.7 ft2 0 0.75 0 4/6/2021 7:07 PM 7.0.00 - FlaRes202O FBC 7th Editio (2020) Compliant Software Page 4 of 7 5 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenue Revised Ecolnnovative 772-501-0152 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity dth Height Sheathing Framing Solar Below QMJ 10 Wall Type Space 24 E Exterior Concrete. Block - Int Insul WIC 4.0999 8 4 10 83.3 ftz 0 0.75 0 25 E Exterior Concrete Block - Int InsMaster Bathro 4.0999 16 2 10 161.7 ftz 0 0.75 0 26 S Exterior Concrete Block - Int InsMaster Bathro 4.0999 17 4 10 173.3 ftz 0 0.75 0 27 W Exterior Concrete Block - Int InsMaster Bathro 4.0999 12 10 120.0 ftz 0 0.75 0 28 S Exterior Concrete Block - Int Insul Office 4.0999 9 10 13 127.8 ftz 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Dining Room None .46 2 8 8 21.3 ftz WINDOWS Orientation shown is the entered,, Proposed orientation. Wall I Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 28 Metal Low-E Double Yes 0.62 0.16 Y 23.2 ftz 8 ft 0 in 5 ft 0 in Drapes/blinds None 2 S 28 Metal Low-E Double No 0.8 0.7 Y 10.0 ftz 8 ft 0 in 2 ft 0 in Drapes/blinds None 3 S 1 Metal Low-E Double No 0.8 0.7 Y 13.1 ft 8 ft 0 in 2 ft 0 in. Drapes/blinds None 4 S 2 Metal Low-E Double Yes 0.62 o.le Y 23.2 ftz 8 ft 0 in 5 ft 0 in Drapes/blinds None 5 S 2 Metal Low-E Double No 0.8 0.7 Y 10.0 ftz 8 ft 0 in 2 ft 0 in Drapes/blinds None 6 W 9 Metal Low-E Double Yes 0.58 0.17 Y 16.2 ft' 0 It 16 in 2 ft 0 in Drapes/blinds None 7 W 11 Metal Low-E Double Yes 0.58 0.71 Y 11.6 ftz 0 ft 16 in 2 ft 0 in Drapes/blinds None 8 W 12 Metal Low-E Double Yes 0.58 0.1 Y 16.2 ftz 0 ft 16 in 2 ft 0 in Drapes/blinds None 9 W 14 Metal Low-E Double Yes 0'.58 0.1 Y 16.2 ft' 0 ft 16 in 2 ft 0 in Drapes/blinds None 10 N 15 Metal Low-E Double Yes 0.58 0.1 Y 16.2 ftz 0 ft 16 in 2 ft 0 in Drapes/blinds None 11 N 20 Metal Low-E Double Yes 0.56 0.1 Y 23.2 ftz 10 ft 0 in 2 ft 0 in Drapes/blinds None 12 N 21 Metal Low-E Double Yes 0.58 0.1 Y 23.2 ftz 10 ft 0 in 2 ft 0 in Drapes/blinds None 13 E 23 Metal Low-E Double Yes 0.58 0.1 Y 32.4 ft' 0 ft 16 in 2 ft 0 in Drapes/blinds None 14 S 26 Metal Low-E Double Yes 0.62 0.1 Y 23.2 ftz 0 ft 16 in 2 ft 0 in Drapes/blinds None 15 S 1 Metal Low-E Double No 0.8 0.7 Y 23.5 ftz 8 ft 0 in 5 ft 0 in Drapes/blinds None 16 E 18 Metal Low-E Double No 0.8 0.7 Y 11.8 ftz 40 ft 0 in 2 ft 0 in Drapes/blinds None . 17 N 21 Metal Low-E Double No 0.8 0.7 Y 23.5 ftz 10 ft 0 in , 2 ft 0 in Drapes/blinds None 18 N 22 Metal Low-E Double No 0.8 0.7 Y 23.5 ftz 10 ft 0 in 2 ft 0 in Drapes/blinds None GARAGE i # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 816.93 ftz 816.93 ftz 86 ft loft 1 V, 4/6/2021 7:07 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenue Revised FORM R405-2020 INPUT SUMMARY CHECK<I.IST REPORT Ecolnnovative 772-501-0152 _J INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000222 176.6.7 96.91. 181.97 .0641 3.1 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA .31.4 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype ' Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None Singl SEER: 16 44.5 kBtu/hr 1335 cfm 0.75 1 sys#1 HOT WATERS STEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 4C gal 60 gal 120 deg, None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Collector Model # Area Storage Volume FEF None None ft2 DUCTS — Supply — V # Location R Value Area -- Return — Location Area Leakage Air CFM 25 CFM25 Type Handler TOT OUT QN RLF HVAC # Heat\ Cool 1 Attic 6 328 ft' Pantry 115.5 ft DefaL It Leakage Pantry (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Cooling Jan Feb Mar Heating ent ng Jan Feb X Mar Ceiling Fans: Apr May Jun Apr I May rl Jun Jul Aug Sep il Jul Mug ri Sep � Nov Oct X� Nov Dec � Dec 4/6/2021 7:07 PM 7.0.00 - FlaRes2020'FBC 7th Edition (2020) Compliant Software Page 6 of 7 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenue Revised Ecolnnovative 772-501-0152 FORM R405-2020 INPUT SUMMARY CHECK 6 IST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Foyer Default(8 Ibs/sq.ft. 0 ft2 0 ft 1 0.3 Dining Room Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bathroom 2 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 WIC 4 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 4 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Pantry Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Bathroom 3 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Kitchen Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Great Room Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 WIC Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Bathroom Default(8 Ibsls .ft. 0 ft2 0 ft 0.3 Office 4/6/2021 7:07 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Aven a Revised Ecolnnovative 772-501-0152 FORM R405-2020 ENERGY PERFORMANCE LE EL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Ind x, the more efficient the home. 17650 Orange Ave, Fort Pierce, FL, 34945 + 1. New construction or existing New (From Plans) 1 . Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2570.20 ftz b. Frame - Wood, Adjacent R=13.0 376,00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Roof Deck (Unvented) R=29.0 3342.80 ft2 6. Conditioned floor area (ft2) 3037 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor. Dbl, U=0.58 143.61 ft2 . Ducts, location & insulation level a. a. Sup: Attic, Ret: Pantry, AH: Pantry R ft2 6 328 SHGC: SHGC=0.17 b. U-Factor: Dbl, U=0.62 69.67 ft2 SHGC: SHGC=0.16 1 . Cooling systems kBtulhr Efficiency c. U-Factor: Dbl, U=0.58 11.59 ft2 a. Central Unit 44.5 SEER:16.00 SHGC: SHGC=0.71 d. U-Factor. other (see details) 115.37 ft2 11. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Strip Heat 31.4 COP:1.00 Area Weighted Average Overhang Depth: 7.071 ft. Area Weighted Average SHGC: 0.366 8. Skylights Description Area 15. Hot water systems Cap: 40 gallons a. U-Factor(AVG): NIA ft2 a. Electric EF: 0.98 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 3037.00 ft' C dits (Performance method) None b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficien y Code for Building �zKESrq�, Construction through the above energy saving features which will b in this home before final inspection.. Otherwise, a new EPL Display installed (or exceeded) and will be completed,.a�' based on installed Code compliant features. mn°%. =:,•`' „ O� Builder Signature: Date: 5' / Address of New Home: 1-7 CPS ft -Aye ity/FL Zip: if fCe 3 6( k�• g�* COD WE'T¢� . *Note: This is not a Building Energy Rating. If your Index is boow 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission'i support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/6/2021 7:08 PM 7.0.00 - FlaRes202O FBC 7th v � (2020) Compliant Software r Page 1 of 1 9 April 6, 2021 Energy Code & Load Cale Package 17650 Orange Ecolnnovative 772-501-0152 .t, Florida Building Code,. Energy Conservation, 7th Edition (2020) Mandatory Requirements for Residential Perfprmance, Prescriptive and ERI Methods ADDRESS: 17650 Orange Ave Permit Number. Fort Pierce , FL, 34945 MANDATORY REQUIREMENTS -See individual code'se tions for full details. V SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory).The b ilding official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct bef re final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as n addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating th energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card compFpy led, and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING TH RMAL ENVELOPE ❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall tie constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple a tached single family dwellings shall be permitted to comply with Section C402.5. ❑ R402.4.1 Building thermal envelopeThe building thermal envelope sit all comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for diffen ntial expansion and contraction. ❑ R402.4.1.1 Installation. The components of the building thermal envc lope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R40 .4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. ❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in. Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either Individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i) or an approved third party. A written report of the results of the test shall signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all pane rations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the b� ilding thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery�enfilatcirs shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test,shallaturned off. 6. Supply and return registers, if installed at the time of the test, shall bfully open. ❑R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting Me dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance 41th UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shill be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doers shall have an air infiltration rate of no more than 0.3 cirri per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratoryland listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 4/6/2021 7:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O 1 OBC 7th Edition (2020) Compliant Software P �pnl fi 5 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 MANDATORY REQUIREMENTS - (Continued) ❑R402.4A Rooms containing fuel -burning appliances. In Climate. Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance witli Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: Direct vent appliances with both intake and exhaust pipes Fireplaces and stoves complying with Section R402A.2 ai continuous to the outside. i Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building th�rmal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated-andlabeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (7�.Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceilin covering. R403.1 Controls. SECTION R403 YSTEMS ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat.pumps he ving supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and b ilding cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chamb rs, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be sho to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RE NET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489. 05(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufa urer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 1 E 3. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be'pressure tested to etermine air leakage by one of the following methods: 1. Rough4n test: Total leakage shall be measured with a pr sure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if instz lied at the time of the test. All registers shall be taped or otherwise sealed during the test. 2.' Postconstruction test: Total leakage shall be measured mrith a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where th a ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, end a duct air leakage Qn to the outside of less than 0.080 (where Qn duct leakage to the outside in cfm per`100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not b used as ducts or plenums. ❑R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 55°F (13°C) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation expose to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall prov de shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenances stems (Mandatory). If heated water circulation systems are installed, they shall be in accordance with Section R403.5.1.1. Heat tra temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pum s shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation system shall be provided with a circulation pump. The system return pipe shall be ❑ a dedicated return pipe or a cold water supply pipe. Gravity and the6osiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. �❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 4/6/2021 7:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O qC 7 h Edition (2020) Compliant Software April 6, 2 of 5 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 MANDATORY REQUIREMENTS - (Continued) ❑R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall cc nsist of either a commercially available heat trap or a downward and upward bend of at least 3'/ inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). ❑. R403.5.6.1.1 Automatic controls. Service water -heating system shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). ❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked ci cuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water -heating systems to be turned o . ❑ R403.5.6.2 Water -heating equipment Water -heating equipmen installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Consery ition, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria Section R403.5.6.2.1. . ❑ R403.5.6.2.1 Solar water -heating systems. Solar systems I Dr domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system sha I be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TMA, Solar Domestic Hot Water Systei n and Component.Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and D degrees of the horizontal; and 2. Be installed at an orientation within 45_degrees of true outh. ❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes a id exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6.1 Whole -house mechanical ventilation system fan efficacy. en installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where an air handler that is integral to tested and listed WAG equipment is used to provide whole -house mechanical ventilation, the air handler shall be powered by an electronically commutated motor. ❑ R403.6.2 Ventilation air. Residential buildings designed to be operat d at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buil ings in ASH RAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for ref idential applications. 2. No ventilation or air-conditioning system make-up air shall bo provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces 4djacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the w insulated to a minimum of R-11 and the ceiling shall be insu otherwise. R403J Heating and cooling equipment. R403.7.1 Equipment sizing (Mandatory). Heating and cooling er ❑ the equipment loads calculated in accordance with ACCA Manu based on building loads for the directional orientation of the bulk units (if split system) shall be submitted along with the sensible Section R302.1. This Code does not allow designer safety factor equipment sizing. System sizing calculations shall not include to standard kitchen and bathroom exhaust systems. New or replac equal to or greater than the minimum required by federal law for TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTII of the space(s) from which air is drawn shall be i to a minimum of R-19, space permitting, or R-10 ipment shall be sized in accordance with ACCA Manual S based on J or other approved heating and cooling calculation methodologies, ig. The manufacturer and model number of the outdoor and indoor d total cooling capacities at the design conditions described'in provisions for future expansion or other factors that affect Is created by local intermittent mechanical ventilation such as lent heating and cooling equipment shall have an efficiency rating e geographic location where the equipment is installed. TION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMUIV (CFM) HRV or ERV Any 1.2 cfim/watt Any Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. 4/6/2021 7:08 PM EnergyGauge® USA a. When tested in i iccordance with HVI Standard 916 7.0.00 - FlaRes202O 12 C 7 h Edition (2020) Compliant Software April 6, 20 3 of 5 1 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 MANDATORY REQUIREMENTS - (Continued) ❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value an shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. his selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water- ource equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and th design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be forth a indoor -dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment lzing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent 4 if that load. 2. When signed and sealed by a Florida -registered engineer, n attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design p actice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based n the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be mo than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistancefu aces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil bel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Se tion R403.7.1. c ❑ R403.7.1.3 Extra capacity required for special occasions. Reside ces requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by majo entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provid cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum perfonnan e during base load periods is utilized. R403.8 Systems serving -multiple dwelling units (Mandatory). System serving multiple dwelling units shall comply with Sections C403 ❑ and C404 of the Florida Building Code, Energy Conservation --Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and Ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when Me pavement temperature is above 50°F (10°C), and no precipitation is failing and an automatic or manual control that will allowshutoff when the outdoor temperature is above 40°F (4.80C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with. Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall lie controlled by a Peadily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. uch switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with c ntinuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods tha I can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump opi 2. Pumps that operate solar- and waste -heat -recovery pool 3. Where pumps are powered exclusively from on -site rene g systems. generation. 4/6/2021 7:08 PM EnergyGauge® USA 7.0.00 - FlaRes2020 q§C 7� Edition (2020) Compliant Software April 6, 4 of 5 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 ❑R403.10.3 Covers. Outdoor heated swimming pools and outdoor permane the water surface or a liquid cover or other means proven.to reduce heat Ic Exception: Where more than 70 percent of the energy fc energy, such as from a heat pump or solar energy source, R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil-f ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 20 heaters fired by natural or LP gas shall not have continuously burning pil spas shall be equipped with a vapor -retardant cover on or at heating, computed over an operation season, is from site -recovered .ovens or other vapor -retardant means shall not be required. ed pool and spa heaters shall have a minimum thermal 3, when tested in accordance with ANSI Z 21.56. Pool t lights. ❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A tes report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are no required to meet this standard. ❑R403.11 Portable spas (Mandatory).The energy consumption of requirements of APSP-14. ❑ R403.13 Dehumidifiers (Mandatory If installed, a dehumidifier shall 1. The minimum rated efficiency of the dehumidifier shall be gre is less than 75 pints/day and greater than 2.38 liters/kWh if the total 2. The dehumidifier shall be controlled by a sensor that is install 3. Any dehumidifier unit located in unconditioned space that trer 4. Condensate disposal shall be in accordance with Section Mi ❑ R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply d damper shall be installed in the supply air duct between the dehumidif 2. If a ducted dehumidifier is configured with only its supply duct a backdraft damper shall be installed in the dehumidifier supply duct b 3. A ducted dehumidifier shall not be ducted to or from a central central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditio SECTION ELECTRICAL POWER AND LIGHTING SYSTEMS portable spas shall be controlled by the to the following requirements: )r than 1.7 liters/ kWh if the total dehumidifier capacity for the house ;humidifier capacity for the house is greater than or equal to 75 pints/day. in a location where it is exposed to mixed house air. air from conditioned space shall be insulated to a minimum of R-2. 1.3.1 of the Florida Building Code, Residential. to conforming to the requirements of Section R403.13, s both connected into the supply side of the cooling system, a backdraft inlet and outlet duct. nnected into the supply side of the central heating and cooling system, ✓een the dehumidifier and central supply duct. oted cooling system on the return duct side upstream from the space shall be insulated to a minimum of R-6. ❑ R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens -per -watt or shall utilize lamps with an efficacy o not less than 65 lumens per -watt. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting shall not have continuously burning pilot lights. 4/6/2021 7:08 PM EnergyGauge® USA 7.0.00 - FlaRes202O q�C 7�h Edition (2020) Compliant Software April 6, 5 of 5 Energy Code & Load Calc Package 17650 Orange 2020 - AIR BARRIER AND INSULATION INSPECTION Ecolnnovative 772-501-0152 CRITERIA TABLE AIR BARRIER AND INSULATION If 1.1 a ;TION COMPONENT CRITERIA Project Name: Orange Ave —Revised —Martinez 2021 Builder Name: Cesar Martinez Street: 17650 Orange Ave Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34945 Permit Number. Y U Owner: Cesar and Marcela Martinez Jurisdiction: St Lucie County W s Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligr ed with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors t unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, ar d and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfioor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and cc nditioned spacm. . Recessed lighting Recessed light fixtures installed in the building thermal E nvelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind oibuna and win*na._ Shower/tub The air barrier installed at exterior walls adjacent to shoi vers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate bL Holing thermal envelope shall be sealed to the sub -floor, wall covering or When required to be sealed, concealed fire sprinklers stall only be Lonled rs sealed in a manner that is recommended by the manufa turer. Caulking or other adhesive sealants shall not be used to fill voids between&.6prinkler cover olates and walls or ceilincis. a. In addition, inspection of log walls shall be in accorclance with the provisions of ICG-WU. 4/6/2021 7:08 PM EnergyGauge® USA 7.0.00 - Flakes202O FBC 71 h Edition (2020) Compliant Software 15 Page 1 of 1 April 6, 2021 Energy Code & Load.Calc Package 17650 Orange Ecolnnovative 772-501-0152 Residential System Sizing Calculation SummCIlry Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave_Revised Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Location for weather data: Fort Pierce, FL - Defaults: Latitu e(27.48) Altitude(25 ft.) Temp Range(L) Humidi data: Interior RH 50% Outdoor wet bulb 78F umidity difference62 r. Winter design temperature(TMY3 99%) 40 F Surr mer design temperature(TMY3 99%) 91 F Winter setpoint 70 F Surr mer setpoint 75 F Winter temperature difference 30 F Sury mer temperature difference 16 F Total heating load calculation 42318 Btuh Totill coolin load calculation 39130 Btuh Submitted heating capacity % of calc Btuh Sub nitted cooling capacity % of calc Btuh Total (Electric Strip Heat) 74.2 31400 . S risible (SHR = 0.75) 100.0 33375 Latent 193.0 11125• Tc tal 113.7 44500 WINTER CALCI Winter Heatin Load. for 3037 sqft Load component Load Window total 340 sqft 6315 Btuh Wall total 2585 sqft 10928 Btuh Door total 21 sqft 294 Btuh Ceiling total 3343 sqft 3222 Btuh Floor total See detail report 10167 Btuh Infiltration 58 cfm 1929 Btuh Duct loss 9462 Btuh Subtotal 42318 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS 42318 Btuh SUMMER Gj immor Cnnlinn 1 nari Khr 3nA7 snftl Load component Load Window total 340 sqft 5463 Btuh. Wall total 2585 sqft 7259 Btuh Door total 21 sqft 304 Btuh Ceiling total 3343 sqft 3222 Btuh Floor total 0 Btuh Infiltration 44 cfm 771 Btuh Internal gain 11750 Btuh Duct gain 4595 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 33366 Btuh Latent gain(ducts) 2916 Btuh Latent gain (infiltration) 1848 Btuh Latent gain (ventilation) 0 Btuh Latent gain(intemal/occupants/other) 1000 Btuh Total latent gain 5764 Btuh TOTAL HEAT GAIN 39130 Btuh CA . MANUAL J' EnergyGauge® / L 16 JLATIONS waus(zr -- Ceilings(7b96) Windows(14995) Floors(24.0%) ?j., Dudsj22:4%) ULATIONS Doors(0.795) Infil.(4.6%, Walls(18.6%) Bucts(19.2%) Ceilings(82%) Windotas(14.03;) Latentint(2.6%) Int.Gain(30.0%) EnergyGauge® System Sizing PREPARED BY: / /._.C-l�V COA%t%D DATE: April 6, 2021 ZB v7.0.00 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 r System Sizing Calc Residential Load - Whole H Cesar and Marcela Martinez Project 1 17650 Orange Ave Orange Ave. Revised Fort Pierce, FL 34945 Building Tyg Reference City: Fort Pierce, FL (Defaults) Winter T dations - Winter ise Component Details lanual J_2021 User 4/6/2021 :`Difference: 30.0 F (TMY3 99% Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 2, NFRC 0.16 Metal 0.62 S 23.2 , 18.6 432 Btuh 2 2, Low-E Metal 0.67 S 10.0 20.1 200 Btuh 3 2, Low-E Metal 0.67 S 13.1 20.1 264 Btuh 4 2, NFRC 0.16 Metal 0.62 S 23.2 18.6 432 Btuh 5' 2, Low-E Metal 0.67 S 10.0 20.1 200 Btuh 6 2, NFRC 0.17 Metal 0.58 W 16.2 17.4 282 Btuh 7 2, NFRC 0.71 Metal 0.58 W 11.6 17.4 202 Btuh 8 2, NFRC 0'.17 Metal 0.58 W 16.2 17.4 282 Btuh 9 2, NFRC 0.17 Metal 0.58 W 16.2 17.4 282 Btuh 10 2, NFRC 0.17 Metal 0.58 N 16.2 17.4 282 Btuh 11 2, NFRC 0.17 Metal 0.58 N 23.2 17.4 404 Btuh 12 2, NFRC 0.17 Metal 0.58 N 23.2 17.4 404 Btuh 13 2, NFRC 0.17 Metal 0.58 E 32.4 17.4 563 Btuh 14 2, NFRC 0.16 Metal 0.62 S 23.2 18.6 431 Btuh 15 2, Low-E Metal 0.67 S 23.5 20.1 473 Btuh 16 2, Low-E Metal 0.67 E 11.8 20.1 236 Btuh 17 2, Low-E Metal -0.67 N 23.5 20.1 473 Btuh 18 2, Low-E Metal 0.67 N 23.5 20.1 473 Btuh Window Total 340.2 s ft 6315 Btuh Walls Type Omt. Ueff. R-Value Area X HTM= Load (Cav/Sh 1 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 73 4.48 326 Btuh 2 Conc Blk,Hollow - Ext (0.149) 4.110.0 81 4.48 361 Btuh 3 Frame - Wood - Adj (0.089) 13.0/0.0 26 2.66 69 Btuh 4 Frame - Wood - Adj (0.089) 13.0/0.01 16 2.66 43 Btuh 5 Frame - Wood - Adj (0.089) 13.010. 42 2.66 111 Btuh 6 Frame - Wood - Adj (0.089) 13.0/0.0 58 2.66 153 Btuh 7 Frame - Wood - Adj (0.089) 13.0/0.0 78 2.66 209 Btuh 8 Frame - Wood - Adj (0.089) 13.0/0.0 135 2.66 359 Btuh 9 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 112 4.48 502 Btuh 10 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 90 4.48 403 Btuh 11 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 70 4.48 314 Btuh 12 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 112 4.48 502 Btuh 13 Conc Blk,Holldw - Ext (0.149) 4.1/0.0 65 4.48 291 Btuh 14 Conc Blk,Hollow - Ext. (0.149) 4.1/0.0 112 4.48 502'Btuh 15 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 140 4.48 629 Btuh 16 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 67 4.48 298 Btuh 17 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 72 4.48 321 Btuh 18 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 73 4.48 328 Btuh 19 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 ` 13 4.48 60 Btuh 20 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 23 4.48 105 Btuh 21 Conc Blk,Hollow - Ext (0,149) 4.1/0.0 182. 4.48 817 Btuh 22 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 145 4.48 648 Btuh Page 1 17 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenpe_Revised Ecolnnovative 772-501-0152 Manual J Winter Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave Revised Manual J_2021 Fort Pierce, FL 34945 Building Ty p : User 4/6/2021 Walls 23 24 25 26 27 .28 Type Omt. Ueff. Conc Blk,Hollow - Ext (0.149) Conc Blk,Hollow - Ext (0.149) Conc Blk,Hollow - Ext (0.149) Conc BIk,Hollow - Ext (0.149) Conc Blk,Hollow - Ext (0.149) Conc Blk,Hollow - Ext (0.149) Wall Total R-Value (Cav/Sh 4.1/0. 4.1/01 4.1/0. 4.1/0. 4.1/01 4.1/0.0 Area X 189 83 162 150 120 95 2585 s ft HTM= 4.48 4.48 4.48 4.48 4.48 4.48 Load 847 Btuh 373 Btuh 724 Btuh 672 Btuh 537 Btuh 424 Btuh 10928 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood - Garage, n (0.460) 21 13.8 294 Btuh Door Total 21 s ft 29413tuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Unvent Attic/L/Metal (0,241) 0.0/29.0 150 1.0 145 Btuh 2 Unvent Attic/L/Metal (0.241) 0.0/29.0 262 1.0 252 Btuh 3 Unvent Attic/L/Metal (0.241) 0.0/29.0 49 1.0 47 Btuh 4 Unvent Attic/L/Metal (0.241) 0.0/29.0 50 1.0 48 Btuh 5 Unvent Attic/L/Metal (0.241) 0.0/29.0 187 1.0 180 Btuh 6 Unvent Attic/L/Metal (0.241) 0.0/29.0 1.28 1.0 123 Btuh 7 Unvent Attic/L/Metal (0.241) 0.0/29.0 197 1.0 190 Btuh 8 Unvent Attic/L/Metal (0.241) 0.0/29.0 61 1.0 59 Btuh 9 Unvent Attic/L/Metal (0.241) 0.0/29.0 201 1.0 194Btuh 10 Unvent Attic/L/Metal (0.241) 0.0/29.0 48 1.0 46 Btuh 11 Unvent Attic/L/Metal (0.241) 0.0/29.0 57 1.0 55 Btuh 12 Unvent Attic/L/Metal (0.241) 0.0/29.0 353 1.0 340 Btuh 13 Unvent Attic/L/Metal (0.241) 0.0/29.0 594 1.0 573 Btuh 14 Unvent Attic/L/Metal (0.241) 0.0/29.0 411 1.0 396 Btuh 15 Unvent Attic/L/Metal (0.241) 0.0/29.0 140 1.0 135 Btuh 16 Unvent Attic/L/Metal (0.241) 0.0/29.0. 279 1.0 269 Btuh 17 Unvent Attic/L/Metal (0.241) 0.0/29.0 176 1.0 170Btuh Ceiling Total I 3343 s ft 322213tuh EnergyGauge® I USRPZB v7.0.00 Page 2 18 1 April 6, 2021 Energy Code & Load Cale Package 17650 Orange Ecolnnovative 772-501-0152 Manual J Winte Residential Load - Compo Cesar and Marcela Martinez Project' 17650,Orange Ave Orange Ave_Revisec Fort Pierce, FL 34945 Building Tyl Calculations .nt Details (continued) lanual J_2021 User 4/6/2021 Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 8.5 ft(perim.) 35.4 301 Btuh 2 Slab On Grade (1.180) 0.0 - 15.0 ft(perim.) 35.4 531 Btuh 3 Slab On Grade (1.180) 0.0 10.0 ft(perim.) 35.4 354 Btuh 4 Slab On Grade (1.180) 0.0 7.8 ft(perim.). 35.4 276 Btuh 5 Slab On Grade (1.180) 0.0 35.5 ft(perim.) 35.4 1257 Btuh 6 Slab On Grade (1.180) . 0.0 8.3 ft(perim.) 35.4 294 Btuh 7 Slab On Grade (1.180) 0.0 12.8 ft(perim.) .35.4 453 Btuh 8 Slab On Grade (1.180) 0.0 6.7 ft(perim.) 35.4 237 Btuh 9 Slab On Grade (1.180) 0.0 28.5 ft(perim.) 35.4 1009 Btuh 10 Slab On Grade (1.180) 0.0 13.9 ft(perim.) 35.4 492 Btuh 11 Slab On Grade (1.180) 0.0 8.5 ft(perim.) 35.4 301 Btuh 12 Slab On Grade' (1.180) 0.0 6.0 ft(perim.) 35.4 212 Btuh 13 Slab On Grade (1.180) 0.0 23.0 ft(perim.) 35.4 814 Btuh 14 Slab On Grade (1.180) 0.0 39.0 ft(perim.) 35.4 1381 Btuh 15 Slab On Grade (1.180) 0.0 8.3 ft(perim.) 35.4 294 Btuh 16 Slab On Grade (1.180) 0.0 45.5 ft(perim.) 35.4 1611 Btuh 17 Slab On Grade (1.180) 0.0 9.9 ft(perim.) 35.4 350 Btuh Floor Total 3037 s ft 10167 Btuh Envelope Subtotal: 30927 Btuh Infiltration Type Wholehouse ACH Volume(cult) Wall Ratio CFM= Natural 0.10 34195 1.00' 58.5 1929 Btuh Duct load Average sealed, R6.0, Supply(Att), Return(Con) (DLM of 0.288) 9462 Btuh All Zones Sensib a Subtotal All Zones 42318 Btuh Subtotal Sensible Heat Loss 42318 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 42318 Btuh EnergyGauge®/ US CZB v7.0.00 19 Page 3 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 Manual J Winter Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez � Project Title: 17650 Orange Ave Orange Ave Revised Manual J_2021 Fort Pierce, FL 34945 Building Typ :User 4/6/2021 1. Electric Strip Heat 31400 Btuh Key: Window types - NFRC (Requires U-Factor and Shading coefficient(SHG ) of glass as numerical values) or- Glass as'Cleae or Tint' (Uses U-Factor and SHGC defaults) U - (Window U-Factor) HTM - (ManualJ Heat Transfer Multiplier) EnergyGauge®/ USR ZB v7.0.00 20 Parcererl U1' ACC'p. MANUAL J. Page 4 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 6 System Sizing Calculations - Summer Residential Load - Whole House Component Details Cesar and Marcela Martinez Project Ti le: 17650 Orange Ave Orange Ave -Revised Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Reference City: Fort Pierce, FL Temperature Differeflce: 16.OF(TMY3 99%) Humidity difference: 62gr. Window Type* Panes SHGC U InSh IS Omt Overhang Len H t Wind Gross ow Area(sqft) Shaded Unshaded HTM Shaded Unshaded Load 1 2 NFRC 0.16, 0.62 B-L No S 8.0% 5.Oft. 23.2 23.2 0,0 12 12 268 Btuh 2 2 Low-E 0.61, 0.67 B-L No S 8.Oft. 2.Oft. 10.0 10.0 0.0 16 18 157 Btuh 3 2 Low-E 0.61, 0.67 B-L No S 8.0ft. 2.Oft. 13.1 13.1 0.0 16 18 206 Btuh 4 2 NFRC 0.16, 0.62 B-L No S 8.0% 5.Oft. 23.2 23.2 0.0 12 12 268 Btuh 5 2 Low-E 0.61, 0.67 B-L No S 8.Oft. 2.0% 10.0 10.0 0.0 16 18 157 Btuh 6 2 NFRC 0.17, 0.58 B-L No W 1.3% 2.Oft. 16.2 0.0 16.2 11 20 325 Btuh 7 2 NFRC 0.71, 0.58 B-L No W 1.3% 2.Oft. 11.6 0.0 11.6 15 46 534 Btuh 8 2 NFRC 0.17, 0.58 B-L No W 1.3ft. 2.Oft. 16.2 . 0.0 16.2 11 20 325 Btuh 9 2 NFRC 0.17, 0.58 B-L No W 1.3% 2.Oft. 16.2 0.0 16.2 11 20 325 Btuh 10 2 NFRC 0.17, 0.58 B-L No N 1.3ft. 2.Oft. 16.2 0.0 16.2 11 11 178 Btuh 11 2 NFRC 0.17, 0.58 B-L No N 10.01' 2.Oft. 23.2 0.0 23.2 11 11 255 Btuh 12 2 NFRC 0.17, 0.58 B-L No N 10.0f 2.Oft. 23.2 0.0 23.2 11 11 255 Btuh 13 2 NFRC 0.17, 0.58 B-L No E 1.3ft. 2.Oft. 32.4 0.0 32.4 11 20 649 Btuh 14 2 NFRC 0.16, 0.62 B-L No S 1.3ft. 2.Oft. 23.2 23.2 0.0 12 12 267 Btuh 15 2 Low-E 0.61, 0.67 B-L No S 8.Oft. 5.Oft. 23.5 23.5 0.0 16 18 370 Btuh 16 2 Low-E 0.61, 0.67 B-L No E 40.Of 2.0% 11.8 11.8 0.0 16 42 185 Btuh 17 2 Low-E 0.61, 0.67 B-L No N 10.Of 2.Oft. 23.5 0.0 23.5 16 16 370 Btuh 18 2 Low-E 0.61, 0.67 B-L No . N 10.Of 2.Oft. 23.5 0.0 23.5 16 16 370 Btuh Window Total 1 1 340 ft 5463 Btuh • EnergyGauge® / USRCZB v7.0.00 Page 1 21 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 Manual. J Summ Residential Load - Compc Cesar and Marcela Martinez Project 17650 Orange Ave Orange Ave -Revise Fort Pierce, FL 34945 r Calculations ent Details (continued) le: Climate:FL_VERO_BEACH_MUNICIPAL A Manual J_2021 4/6/2021 Walls. Type U-Value R-Value Area(sgft) HTM Load Cav/Sheath 1 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 72.8 3.0 220 Btuh 2 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 80.5 3.0 244 Btuh 3 Frame - Wood - Adj 0.09 13.0/0.0 26.0 1.4 37 Btuh 4 Frame - Wood - AdJ 0.09 13.0/0.0 16.2 1.4 23 Btuh 5 Frame - Wood - Adj 0.09 13.0/0.0 41.7 1.4 59 Btuh 6 Frame - Wood - Adj 0.09 13.0/0.0 57.5 1.4 82 Btuh 7 Frame - Wood - Adj 0.09 13.0/0.0 78.3 1.4 111 Btuh 8 Frame - Wood - Adj 0.09 13.0/0.0 135.0 1.4 192 Btuh 9 Concrete Blk,Hollow - Ext 0.15 4A/0.0 112.1 3.0 340 Btuh 10 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 90.0 3.0 273 Btuh 11 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 70.1 3.0 212 Btuh 12 Concrete Blk,Hollow - Ext 0.15 '4.1/0.0 112.1 3.0 340 Btuh 13 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 65.0 3.0 197 Btuh 14 Concrete BIk,Hollow - Ext 0.15 4.1/0.0. 112.1 3.0 340 Btuh 15 Concrete Blk,Hollow -Ext. 0.15 4.1/0.0 140.5 3.0 426 Btuh 16 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 66.7 3.0 202 Btuh 17 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 71.7 3.0 217 Btuh 18 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 73.2 3.0 222 Btuh 19 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 13.3 3.0 40 Btuh 20 ConcreteBlk,Hollow -Ext 0.15 4.1/0.0 23.4 3.0 71 Btuh 21 Concrete Blk,Hollow - Ext 0.15 4.110.0 182.4 3.0 553 Btuh 22 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 144.8 . 3.0 439 Btuh 23 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 189.3 3.0 573 Btuh 24 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 83.3 3.0 252 Btuh 25 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 161.7 3.0 490 Btuh 26 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 150.1 3.0 455 Btuh 27 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 120.0 3.0 364 Btuh 28 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 94.6 3.0 287 Btuh Wall Total 2585 s ft . 7259 Btuh Doors Type Area (sgft) HTM Load 1 Wood - Garade 21.3 14.3 304 Btuh Door Total 21 (sqft) 304 Btuh EnergyGauge®/ USRCZB v7.0.00 22 1 April 6, 2021 Page 2 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 Manual J Summeir Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate:FL_VERO_BEACH_MUNICIPAL A 17650 Orange Ave Orange Ave_Revised Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Ceilings Type/Color/Surface U-Value R-Valu Area(sgft) HTM Load 1 Unvented Aftic/Light/Metal 0.241 0.0129.0 150.0 0.96 145 Btuh 2 Unvented Attic/LightMetal 0.241 0.0/29.0 261.5 0.96 252 Btuh 3 Unvented Attic/LightMetal 0.241 0.0129.0 49.0 0.96 47 . Btuh 4 Unvented Attic/LighUMetal 0.241 0.0/29.0 50.0 0.96 48 Btuh 5 Unvented AtticlUghtMetal 0.241 0.0129.0 187.0 0.96 180 Btuh 6 Unvented Attic/LighUMetal 0.241 0.0/29.0 128.0 0.96 123 Btuh 7 Unvented AfticlUght/Metal 0.241 0.0/29.0 197.0 0.96 190 Btuh 8 Unvented Aftic/LightMetal 0.241 0.0/29.0 61.0 0.96 59 Btuh 9 Unvented AftictUght/Metal 0.241 0.0/29.0 201.0 0.96 194 Btuh . 10 Unvented Attic/LighUMetal 0.241 0.0/29.0 48.0 0.96 46 Btuh 11 Unvented Aftic/LightMetal 0.241 0.0129.0 57.0 0.96 55 Btuh 12 Unvented Attic/Light/Metal 0.241 0.0/29.0 353.0 0.96 340 Btuh 13 Unvented Aftic/LighUMetal 0.241 0.0/29.0 594.0 0.96 573 Btuh 14 Unvented Attic/LighUMetal 0.241 0.0/29.0 411.0 0.96 396 Btuh 15 Unvented Aftic/LighUMetal 0.241 0.0/29.0 140.0 0.96 135 Btuh 16 Unvented Attic/Light/Metal 0.241 0.0/29.0 279.0 0.96 269 Bt6h 17 Unvented Attic/Light/Metal 0.241 �0.0/29.0 176.3 '0.96 170 Btuh Ceiling Total 1 3343 sgft 3222 Btuh Floors I Tvoe R-Value I Size HTM I Load 1 Slab On Grade 0.0 105 (ft-perimeter) 0.0 0 Btuh 2 Slab On Grade 0.0 215 (ft-perimeter) 0.0 0 Btuh 3 Slab On Grade 0.0 49 (ft-perimeter) 0.0 0 Btuh 4 Slab On Grade 0.0 50 (ft-perimeter) 0.0 0 Btuh 5 Slab On Grade 0.0 187 (ft-perimeter) 0.0 0 Btuh 6 Slab On Grade 0.0 128 (ft-perimeter) 0.0 0 Btuh 7 Slab On Grade 0.0 197 (ft-perimeter) 0.0 0 Btuh 8 Slab On Grade 0.0 61 (ft-perimeter) 0.0 0 Btuh 9 Slab On Grade 0.0 201 (ft-perimeter) 0.0 0 Btuh 10 Slab On Grade 0.0 48 (ft-perimeter) 0.0 0 Btuh 11 Slab On Grade 0.0 57 (ft-perimeter) 0.0 0 Btuh 12 Slab On Grade 0.0 309 (ft-perimeter) 0.0 0 Btuh 13 Slab On Grade 0.0 517 (ft-perimeter) 0.0 0 Btuh 14 Slab On Grade 0.0 365 (11-perimeter) 0.0 0 Btuh 15 Slab On Grade 0.0 140 (ft-perimeter) 0.0 0 Btuh 16 Slab On Grade 0.0 279 (ft-perimeter) 0.0 0 Btuh 17 Slab On Grade 0.0 129 (ft-perimeter) 0.0 0 Btuh Floor Total 3037.0 (sqft) 0 Btuh Envelope Subtotal: 1 16249 Btuh Infiltration Type Average ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 134195 1 43.9 Load 771 Btuh Internal gain Occupants Btuh/occupant Appliance 5 X 230 + ' 10600 Load 11750 Btuh i Sensible Envelope Load: 28770 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.o-Condi) (DGM of 0.160) 4595 Btuh Sensible Load All Zones 33366 Btuh i EnergyGauge®/ USRCZB v7.0.00 23 April 6, 2021 Page 3 i Energy Code & Load Calc Package 17650 Orange Aven e—Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations. Residential Load - Component Details (continued) Cesar and,Marcela Martinez Project Title: Climate:FL_VERO_BEACH_MUNICIPAL_A 176.50 Orange Ave Orange Ave —Revised —Manual J_2021 Fort Pierce, FL 34945 4/6/2021 I Sensible Envelope Load All Zones 28770. Btuh Sensible Duct Load j 4595 Btuh Total Sensible Zone oads 33366 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 33366 Btuh Totals.for Cooling Latent infiltration gain (for 2 gr. humidity difference) 1848 Btuh Latent ventilation gain 0 Btuh Latent duct gain 2916 Btuh Latent occupant gain (5.0 r eople @ 2001 Btuh per person) 1000 Btuh Latent other gain 0 Btuh Latent total gain .5764 Btuh TOTAL GAIN 39130 Btuh 1. Central Unit Rheem #RA1648AJ1 44500 Btuh *Key: Window types (Panes - Number and type of panes of glass) 1 (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U-Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half(%)) (Omt - compass orientation) i I i I I EnergyGauge®/ USRCZB v7.0.00 24 I Page 4 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 System Sizing Calculations - Winter Residential Load - Room by Room Component Details Cesar and Marcela Martinez . Project Title: 17650 Orange Ave Orange Ave -Revised IManual J_2021 Fort Pierce, FL 34945 Building Typel: User 4/6/2021 Reference City: Fort Pierce, FL (Defaults) Winter Temperature Difference: 30.0 F (TMY3 99% Window Panes/Type Frame U Orientatio Area s ft X HTM= Load 3 2, Low-E Metal 0.67 S 13.1 20.1 264 Btuh 15 2, Low-E Metal 0.67 S 23.5 20.1 473 Btuh Window Total 36.6 s ft 737 Btuh Walls Type Omt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Conc Blk,Hollow - Ext (0.149) 4.1/0.0� 73 4.48 326 Btuh Wall Total 73 s ft 326 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X ! HTM= Load 1 Unvent Attic/L/Metal (0.241) 0.0/29.0 150 1.0 145 Btuh Ceiling Total 150 s ft 145Btuh Floors Type Ueff. R-Value Size X - HTM= Load 1 Slab On. Grade (1.180) 0.0 8.5 ft(perim.) 35.4 301 Btuh Floor Total 105 s ft 301 Btuh Roo Envelope Subtotal: 1508 Btuh Infiltration Type Wholehouse ACH Room �olume Wall Ratio CFM= Natural 0.10 1365 0.03 1.6 54 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288) 450 Btuh Room #1 Senslbll Room Subtotal 2012 Btuh Window Panes/Type Frame U Orientationl Area s ft X HTM= Load 4 2, NFRC 0.16 Metal 0.62 S 23.2 18.6 432 Btuh 5 2, Low-E Metal 0.67 S 10.0 20.1 200 Btuh Window Total 33.2 s ft 633 Btuh Walls Type Omt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 2 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 81 4.48 361 Btuh 3 Frame - Wood - Adj (0.089) 13.0/0.0 26 2.66 69 Btuh 4 Frame - Wood - Adj (0.089) 13.01/0.6 16 2.66 43 Btuh Wall Total 123 s ft 473 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood - Garage,. n (0.460) 21 13.8 294 Btuh Door Total 21 s ft 29413tuh EnergyGauge® / UMM v7.0.00 25 April 6, 2021 Page 1 Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 Manual J Winter Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave_ Revised_ Manual J_2021 Fort Pierce, FL 34945 Building Type User 4/6/2021 Ceilings Type/Color/Surface Ueff. R-Value j Area X HTM= Load 2 Unvent Attic/L/Metal (0.241) 0.0/29.0 262 1.0 252 Btuh Ceiling Total 262 s ft 2526tuh Floors Type Ueff. R-Value Size X HTM= Load 2 Slab On Grade (1.180) 0.0 15.0 ft(perim.) 35.4 531 Btuh Floor Total 215 s ft 531 Btuh Roo i Envelope Subtotal: 2183 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 2765 0.05 2.8 92 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288) 655 Btuh Room #2 Sensible Room Subtotal 2929 Btuh Component Loads":for Room #3 : Bathroom Walls Type Ornt. Ueff. R-Value j Area X HTM= Load (Cav/Sh) 5 Frame - Wood - Adj (0.089) 13.0/0.0 42 2.66 111 Btuh 6 Frame - Wood - Adj (0.089) 13.0/0.0 58 2.66 153 Btuh Wall Total I 99 s ft 264 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 3 Unvent Attic/L/Metal (0.241) 0.0/29.0 49 1.0 47 Btuh Ceilinq Total 49 s ft 4713tuh Floors Type . Ueff. R-Value Size X HTM= Load 3 Slab On Grade (1.180) 0.0 10.0 ft(perim.) 35.4 354 Btuh Floor Total 49 s ft 354 Btuh Room Envelope Subtotal: 665 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 490 0.04 2.2 74 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.), (DLM of 0.288) 213 Btuh Room #3 i Sensible Room Subtotal 952 Btuh i EnergyGauge® / USRCZB v7.0.00 Page 2 26 April 6, 2021 Energy Code & Load Calc Package I 17650 Orange Avenue_Revised Ecolnnovative 772-501-0152 Manual J Winter' Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave_Revised_Manual J_2021 Fort Pierce, FL 34945 Building Type: User 1 4/6/2021 Component Loads for Room #4: WIC 4 } Walls Type Ornt. Ueff. R-Value I Area X HTM= Load (Cav/Sh) 7 Frame - Wood - Adj (0.089) 13.0/0.0 78 2.66 209 Btuh Wall Total I 78 s ft 209 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 4 Unvent Attic/L/Metal (0.241) 0.0/29.0 50 1.0 48 Btuh Ceilina Total 50 s ft 48Btuh Floors Type Ueff. R-Value Size X HTM= Load 4 Slab On Grade (1.180) 0.0 7.8 ft(perim.) 35.4 276 Btuh Floor Total 50 s ft 276 Btuh Room Envelope Subtotal: 533 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 500 0.03 1.8 58 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288) 170 Btuh Room #4 Sensible Room Subtotal 762 Btuh Component Loads for Room #5: Bedroom 4 1 Window Panes/Type Frame U Orientation Area s ft X HTM= Load 6 2, NFRC 0.17 Metal 0.58 W 16.2 17.4 282 Btuh Window Total 16.2 s ft 282 Btuh Walls Type Omt. Ueff. R-Valuel Area X HTM= Load (Cav/Sh) 8 Frame - Wood - Adj (0.089) 13.0/0.0 135 2.66 359 Btuh 9 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 112 4.48 502 Btuh 10 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 90 4.48 403 Btuh Wall Total I 337 s ft 1264 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 5 Unvent Attic/L/Metal (0.241) 0.0/29.0 187 1.0 180 Btuh Ceiling Total 187 s ft 180Btuh Floors Type Ueff. R-Value I Size X HTM= Load 5 Slab On Grade (1.180) 0.0 ; 35.5 ft(perim.) 35.4 1257 Btuh Floor Total 187 s ft 1257 Btuh EnergyGauge® / USRCZB v7.0.00 i 27 Page 3 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenue_Revised Ecolnnovative 772-501-0152 Manual J Winter' Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange. Ave_ Revised_ Manual J_2021 Fort Pierce, FL 34945 Building Type., User 4/6/2021 Room Envelope Subtotal: 2983 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 1870 0;13 7.6 252 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond:) (DLM of 0.288) 932 Btuh Room #5 Sensiblle Room Subtotal 4166 Btuh Window Panes/Type Frame U Orientation) Area s ft X HTM= Load 7 2, NFRC 0.71 ',- Metal 0.58 W 11.6 17.4 202 Btuh Window Total 11.6 s 202 Btuh Walls Type Omt. Ueff. R-Value Area X HTM= Load. (Cav/Sh) 11 Cone BIk,Hollow - Ext (0.149) 4.1/0.0 70 4.48 314 Btuh Wall Total 70 s ft 314 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 6 Unvent Attic/L/Metal (0.241) 0.0/29.0 128 1.0 123 Btuh Ceiling Total 128 s ft 123Btuh Floors Type Ueff. R-Value Size X ; HTM= Load 6 Slab On Grade (1.180) 0.0 8.3 ft(perim.) 35.4 294 Btuh Floor Total 128 s ft 294 Btuh Room Envelope Subtotal: 933 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 1280 0.03 1.6 52 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) I (D�LM of 0.288) 284 Btuh Room #6 Sensible Room Subtotal 1269 Btuh I I i EnergyGauge®/ USRCZB v7.0.00 Page 4 28 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 I Manual J Winter; Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave_ Revised_ Manual J_2021 Fort Pierce, FL 34945 Building Type; User 4/6/2021 Component Loads for Room #7: Bedroom 3 Window Panes/Type Frame U Orientation' Area s ft X HTM= Load 8 2, NFRC 0.17 Metal 0.58 W 16.2 17.4 282 Btuh Window Total 16.2 s ft 282 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 12 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 112 4.48 502 Btuh Wall Total 112 s ft 502 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 7 Unvent Attic/L/Metal (0.241) 0.0/29.0 197 1.0 190 Btuh Ceiling Total 197 s ft 19013tuh Floors Type Ueff. R-Value Size X HTM= Load 7 Slab On Grade (1.180) 0.0 12.8 ft(perim.) 35.4 453 Btuh Floor Total 197 s ft 453 Btuh Roo Envelope Subtotal: 1427 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 19�0 0.04 2.5 84 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288) 435 Btuh Room #7 Sensib a Room Subtotal 1945 Btuh ( Component Loads for Room #8: KWIC 3" Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 13 Conc BIk,Hollow - Ext (0.149) 4.1/0.0 65 4.48 291 Btuh Wall Total 65 s ft 291 Btuh Ceilings Type/Color/Surface ' Ueff. R-Value Area X HTM= Load 8 Unvent Attic/L/Metal (0.241) 0.0/29.0 61 1.0 59 Btuh Ceilina Total 61 s ft 59Btuh Floors Type Ueff. R-Value Size X HTM= Load 8 Slab On Grade (1.180) 0.0 6.7 ft(perim.) 35.4 237 Btuh Floor Total 61 s ft 237 Btuh Room Envelope Subtotal: i 587 Stuh Energy0auge®/ US ICZB v7.0.00 Page 5 29 April 6, 2021 • Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 0 Manual J Winter Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave Revised_Vlanual J_2021 Fort Pierce; FL 34946 Building Typed: User 4/6/2021 Infiltration Type Wholehouse ACH Room Natural 0.10 6I10 Volume Wall Ratio CFM= 0.03 1.5 49 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288) 183 Btuh Room #8 Sensib a Room Subtotal 819 Btuh Window Panes/Type Frame U Orientation Area s ft X HTM= Load 9 2, NFRC 0.17 Metal 0.58 W 16.2 17.4 282 Btuh 10 2, NFRC 0.17 Metal 0.58 N 16.2 17.4 282 Btuh Window Total 32.4 s ft 563 Btuh Walls Type Omt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 14 Conc Blk,Hollow - Ext (0.149) 4.1/0.0' 112 4.48 502 Btuh 15 Conc Blk,Hollow - Ext (0.149) 4.1/0.0� 140 4.48 629 Btuh Wall Total I 253 s ft 1131 Btuh Ceilings. Type/Color/Surface Ueff. R-Value Area X HTM= Load 9 Unvent Attic/L/Metal (0.241) 0.0/29.0 201 1.0 194 Btuh Ceiling; Total 201 s ft 19413tuh Floors Type Ueff. R-Value Size X HTM= Load 9 Slab On Grade (1.180) 0.0 28.5 ft(perim.) 35.4 1009 Btuh Floor Total 201 s ft 1009 Btuh Roo I Envelope Subtotal: 2897 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 2010 0.10 5.7 189 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288) 889 Btuh Room #9 Sensible Room Subtotal 3974 Btuh i EnergyGauge® / USRCZB v7.0.00 Page, 6 I 30 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Ecolnnovative 772-501-0152 Manual J Winter Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave Revised I Manual J_2021 Fort Pierce, FL 34945 Building Type: User 1 4/6/2021 Component Loads for Room #10: WIC 2. Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Shi 16 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 67 4.48 298 Btuh 17 Conc Blk,Hollow - Ext (0.149) 4.110.0 72 4.48 321 Btuh Wall Total 138 s ft 619 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 10 Unvent Attic/L/Metal (0.241) 0.0129.0 48 1.0 46 Btuh Ceilinq Total 48 s ft 4613tuh Floors Type Ueff. R-Value Size X HTM= Load 10 Slab On Grade (1.180) 0.0 13.9 ft(pedm.) 35.4 492 Btuh Floor Total 48 s ft 492 Btuh Roo Envelope Subtotal: T 1158 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 I80 0.05 3.1 103 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-fond. (DLM of 0.288) 363 Btuh Room #10 Sensible Room Subtotal 1624 Btuh (Component Loadsfor Room #11: Bathroomr3, Window Panes/Type Frame U Orientation Area s ft X HTM= Load 16 2, Low-E Metal. 0.67 E 11.8 20.1 236 Btuh Window Total 11.8 s ft 236 Btuh Walls Type Omt. Ueff. R-Valuej Area X HTM= Load (Cav/Sh) 18 Conc Blk,Hollow - Ext (0.149) 4.1/0.6 73 4.48 328 Btuh Wall Total I 73 s ft 328 Btuh Ceilings Type/Color/Surface Ueff. R-Value I Area X HTM= Load 11 Unvent Attic/L/Metal (0.241) 0.0/29.01 57 1.0 55 Btuh Ceiling Total 1 57 s ft 55Btuh Floors Type Ueff. R-Value Size X , HTM= Load 11 Slab On Grade (1.180) 0.0 8.5 ft(perim.) 35.4 301 Btuh Floor Total 57 s ft 301 Btuh Roo Envelope Subtotal: 920 Btuh I i EnergyGauge® / USRUB v7.0.00 31 Page 7 1 April 6, 2021 Energy Code & Load Cale Package 17650 Orange Avenue_Revised Ecoinnovative 772-501-0152 Manual J Winter Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17660 Orange Ave Orange Ave Revised I Manual J_2021 Fort Pierce, FL 34945 Building Type: User 4/6/2021 Infiltration Type Wholehouse ACH RoomlVolume Natural 0.10 570 Wall Ratio CFM= 0.03 1.7 55 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.i (DLM of 0.288) 281 Btuh Room #11 Sensible Room Subtotal 1256 Btuh Component Loads, for Room #12: Kitchen" JI Window Panes/Type Frame U Orientation Area s ft X HTM= Load 11 2, NFRC 0.17 Metal 0.58 N 23.2 17.4 404 Btuh Window Total 23.2 s ft 404 Btuh Walls Type Omt. Ueff. R-Value Area X HTM= Load (Cav/Shi� 19 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 13 4.48 60 Btuh 20 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 23 4.48 105 Btuh Wall Total i 37 s ft 165 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 12 Unvent Attic/L/Metal (0.241) 0.0/29.0 353 1.0 340 Btuh Ceilino Total 353 s ft 3406tuh Floors Type Ueff. R-Valuel Size X HTM= Load 12 Slab On Grade (1.180) 0.0 6.0 ft(perim.) 35.4 212 Btuh Floor Total I 309 s ft 212 Btuh Roo, Envelope Subtotal: 1122 Btuh Infiltration Type Wholehouse ACH RoomlVolume Wall Ratio CFM= Natural 0.10 4d17 0.01 0.8 27 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288) 331 Btuh Room #12 Sensible Room Subtotal 1480 Btuh EnergyGauge® / USRCZB v7.0.00 Page 8 32 April 6, 2021 I Energy Code & Load Cale Package 17650 Orange Avenue -Revised Ecolnnovative 772-501-0152 , Manual J Winter Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave Revised I Manual J_2021 Fort Pierce, FL 34945 Building Type: User 4/6/2021 (Component Loads for Room 913: Great Room Window Panes/,Type Frame U Orientation Area s ft X HTM= Load 12 2, NFRC 0.17 Metal 0.58 N 23.2 17.4 404 Btuh 17 -2, Low-E Metal 0.67 N 23.5 20.1 473 Btuh Window Total 46.8 s ft 877 Btuh Walls Type Omt. Ueff. R-Value,' Area X HTM= Load (Cav/Sh) 21 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 182 4.48 817 Btuh Wall Total I 182 s ft 817 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 13 Unvent Attic/L/Metal (0.241) 0.0/29.0 594 1.0 573 Btuh Ceiling Total 594 s ft 57313tuh Floors Type Ueff. R-Value Size X HTM= Load 13 Slab On Grade (1.180) 0.0 23.0 ft(perim.) 35.4 814 Btuh Floor Total 517 s ft 814 Btuh Room I Envelope Subtotal: 3081 Btuh Infiltration Type Wholehouse ACH Room iVolume Wall Ratio CFM= Natural 0.10 6721 0.07 I 4.1 136 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288) 926 Btuh Room #13 I Sensible Room Subtotal 4143 Btuh Component Loads for Room #14: Master Bedroom' Window Panes/Type Frame U Orientation Area s ft X HTM= Load 13 2, NFRC 0.17 Metal 0.58 E 32.4 17.4 563 Btuh 18 2, Low-E Metal 0.67 N 23.5 20.1 473 Btuh Window Total 55.9 s ft 1036 Btuh ,Walls Type Omt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 22 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 145 4.48 648 Btuh 23 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 189 4.48 847 Btuh Wall .Total 334 s ft 1496 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X ;. HTM= Load 14 Unvent Attic/L/Metal (0.241) ' 0.0/29.0 411 1.0 396 Btuh Ceiling Total 411 s ft 3966tuh EnergyGauge® / USRCZB v7.0.00 33 April 6, 2021 Page 9 Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 Manual J Winter Calculations Residential Load Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave_ Revised_ Manual J_2021 Fort Pierce, FL 34945 Building Type: User 4/6/2021 Floors 14 Type Ueff. R-Value j Size X HTM= Slab On Grade (1.180) 0.0 39.0 ft(perim.) 35.4 Floor Total 365 s ft Load 1381 Btuh- 1381 Btuh i Rool Envelope Subtotal: 4309 Btuh Infiltration Type Wholehouse ACH Room Volume Wall !Ratio CFM= Natural 0.10 3650 0.13 7.6 249 Btuh Duct load Average sealed, Suppiy(R6.0-Attic), Retum(R6.0-Cond j (DLM of 0.288) 1313 Btuh Room #14 Sensible Room Subtotal 5871 Btuh lComponent Loads for Room #15: WIC . I Walls Type. Ornt. Ueff. R-Value I Area X HTM= Load (Cav/Sh) 24 Conc Blk,Hollbw - Ext (0.149) 4.1/0.0' 83 4.48 373 Btuh Wall Total 83 s ft 373 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 15 Unvent Attic/L/Metal (0.241) 0.0/29.0 140 1.0 135 Btuh Ceilinq Total 140 s ft 1356tuh Floors Type Ueff. R-Value ' Size X HTM= Load 15 Slab On Grade (1.180) 0.0 8.3 ft(perim.) 35.4 294 Btuh Floor Total . 140 s ft 294 Btuh Room Envelope Subtotal: 802 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 1400 0.03 1.9 62 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288.) 249 Btuh Room #15 Sensible Room Subtotal 1113 Btuh EnergyGauge® / USRCZB v7.0.00 Page 10 34 ' April 6, 2021 . a Energy Code & Load Calc Package 17650 Orange Avenue -Revised Ecolnnovative 772-501-0152 Manual J Winter Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave -Revised Manual J_2021 Fort Pierce, FL 34945 Building Type: User 4/6/2021 Component Loads for Room #16:'Master'Bathroom Window Panes/Type Frame U Orientation Area s ft X HTM= Load 14 2, NFRC 0.16 Metal 0.62 S 1 23.2 18.6 431 Btuh Window Total 1 23.2 s ft 431 Btuh Walls Type Ornt. Ueff. R-Value I Area X HTM= Load (Cav/Sh) 25 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 1.62 4.48 724 Btuh 26 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 150 4.48 672 Btuh 27 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 120 4.48 537 Btuh Wall•Total 432 s ft 1933 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 16 Unvent Attic/L/Metal (0.241) 0.0/29.0 279 1.0 269 Btuh Ceilinq Total 279 s ft 26913tuh Floors Type Ueff. R-Value Size X HTM= Load 16 Slab On Grade (1.180) 0.0 45.5 ft(perim.) 35.4 1611 Btuh Floor Total 279 s ft 1611 Btuh Room Envelope Subtotal: 4244 Btuh Infiltration Type. Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.10 2790 0.17 9.8 322 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.)i I (DLM of 0.288) 1315 Btuh Room #16 Sensible Room Subtotal 5881 Btuh Component Loads for Room #17:.Office Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 2, NFRC 0.16 Metal 0.62 S 23.2 18.6 432 Btuh 2 2, Low -It Metal 0.67 S 10.0 20.1 200 Btuh Window Total 33.2 s ft 633 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 28 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 95 4.48 424 Btuh Wall Total 95 s ft 424 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 17 Unvent Attic/L/Metal (0.241) 0.0/29.0 176 1.0 170 Btuh Ceilinq Total 176 s ft 170Btuh EnergyGauge® / USRCZB v7.0.00 Page 11 35 April 6, 2021 1 Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecoinnovative 772-50"152 i i Manual J Winter Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave_Revised_Manual J_2021 Fort Pierce, FL 34945 Building Type: User j 4/6/2021 1 Floors .17 Type Ueff. R-Value Slab On Grade (1.180) 0.0 Floor Total Size X HTM= 9.9 ft(perim.) 35.4 129 s ft Load 350 Btuh 350 Btuh Room { Envelope Subtotal: 1577 Btuh Infiltration Type Wholehouse ACH RoomVolume Natural 0.10 1677 Wall Ratio CFM= 0.04 2.1 71 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DLM of 0.288) 474 Btuh Room 017 Sensible Room Subtotal . 2122 Btuh Subtotal Sensible Heat Loss 42318 Btuh Totals for Heating Ventilation Sensible !Heat Loss 0 Btuh Total Heat Loss 1 42318 Btuh 11. Electric Strip Heat I I 31400 Btuh Key: Window types - NFRC (Requires U-Factor and Shading coefficient(SHGC) of glass as numerical values) or - Glass as'Clear' or'Tint (Uses U-Factor and SHGC defaults) U - (Window U-Factor) ' HTM - (ManualJ Heat Transfer Multiplier) I i Version 8 EnergyGauge® /. USRCZB v7.0.00 Page 12 " I 36 j April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenue_Revised Ecoinnovative 772-501-0152 System Sizing Calculations - Summer Residential Load - Room. by Room Component Details Cesar and Marcela Martinez Project Title: 17650 Orange Ave Orange Ave -Revised -Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Reference City: Fort Pierce, FL Temperature Difference: 16.OF(TMY3 99%) Humidity difference: 62gr. 4,Compo Loads Went Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross IShadedUnshaded Shaded Unshaded 3 2 Low-E 0.61, 0.67 B-L No S 8.0% 2.Oft. 13.1 1 13.1 0.0 , 16 18 206 Btuh 15 2 Low-E 0.61, 0.67 B-L No S 8.Oft. 5.Oft. 23.5 1 23.5 0.0 16 18 370 Btuh Window Total 37 sgft) 576 Btuh Walls Type U-Value .R-Value Area(sqft) HTM Load Cav/Sheath 1 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 1 72.8 3.0 220 Btuh Wall Total i 73 sgft 220 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sgft) HTM Load 1 Unvented Aftic/Light/Metal 0.241 0.0/29.0 150.0 0.96 145 Btuh Ceiling Total 150 s ft 145 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 105 (ft-pedmeter) 0.0 0 Btuh Floor Total 105.0 sgft) 0 Btuh Zone Envelope Subtotal: 1 941 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 1365 0.03 1.2 Load 22 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible_ Envelope Load: 963 Btuh Duct load Average, sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) � DGM of 0.160 154 Btuh Sensible Zone Load 1117 Btuh Window Type* Panes SHGC U InSh IS Omt Overhang Len Hgt Window Area(sqft) - Gross Shaded Unshaded HTM Shaded Unshaded Load 4 2 NFRC 0.16, 0.62 B-L No S 8.Oft. 5.0ft. 23.2 23.2 0.0 ; 12 12 268 Btuh 5 2 Low-E 0.61, 0.67 B-L No S 8.Oft. 2.Oft. 10.0 10.0 0.0 1 16 18 157 Btuh ' Window Total 33 sgft 425 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 2 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 80.5 3.0 244 Btuh 3 Frame - Wood - Adj 0.09 13.0/0.0 26.0 1.4 37 Btuh 4 Frame - Wood - Adj 0.09 13.0/0.0 16.2 1.4 23 Btuh Wall Total 123 sgff 304 Btuh i EnergyGaugeO / USRCZB v7.0.00 37 i April 6, 2021 Page 1 , 1 A Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load- Component Details (continued) Cesar and Marcela Martinez Project Title: Climate:FL VERO_BEACH_MUNICIPAL_A 1,7650 Orange Ave Orange Ave —Revised Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Doors Type Area (sqft) HTM Load 1 Wood - Garage 21.3 14.3 304 Btuh Door Total 21(sqft) 304 Btuh. Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 2 Unvented Aftic/Light/Metal 0.241 0.0/29.0 261.5 . 0.96 252 Btuh Ceiling Total 262 (sqft) 252 Btuh Floors Type R-Value Size HTM Load . 2 Slab On Grade 0.0 215 (ft-perimeter) 0.0 0 Btuh Floor Total 215.0 (sqft) 0 Btuh Zone Envelope Subtotal: 1285 Btuh Infiltration Type Wholehouse ACH Voluine(cuft) Wall Ratio CFM= Load Natural 0.08 2795 0.05 2.1 37 Btuh Internal Occupants Btuh/occupant Appliance Load gain 0 X 230 + 1000 1000 Btuh Sensible Envelope Load: 2321 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) I (DGM of 0.160) 371 Btuh Sensible Zone Load 2692 Btuh Component Loadskfor Room #3 Bathroom 2 N 4 yk �. ,..._ Walls Type U-Value R-Value I Area(sqft) HTM Load Cav/Sheath 5 Frame - Wood - Adj 0.09 13.0/0.0 41.7 1.4 59 Btuh 6 Frame - Wood - Adj 0.09 13.0/0.0 57.5 1.4 82 Btuh Wall Total 99 (sqft) 141 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 3 Unvented Attic/Light/Metal 0.241 0.0/29.0 49.0 0.96 47 Btuh Ceiling Total 49(sqft) 47 Btuh Floors , Type R-Value Size HTM Load 3 Slab On Grade 0.0 49 (ft-perimeter) 0.0 0 Btuh Floor Total 49.0(sqft) 0 Btuh Zone Envelope Subtotal: 188 Btuh EnergyGauge® / USRCZB v7.0.00 Page 2 38 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate:FL VERO_BEACH_MUNICIPAL A 17650 Orange Ave Orange Ave —Revised —Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Infiltration Type Wholehouse ACH Voluine(cuft) Wall Ratio CFM= Natural 0.08 490 0.04 1.7 Load 30 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible Envelope Load: 218 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DGM of 0.160) 35 Btuh i Sensible Zone Load 252 Btuh Com''onenIt Loads for Room #4 `WIC 4 Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 7 Frame - Wood - Adj 0.09 13.010.0 78.3 1.4 111 Btuh Wall Total 78 sgft 111 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sgft) HTM Load 4 Unvented Attic/Light/Metal 0.241 0.0/29.0 50.0 - 0.96 48 Btuh Ceiling Total 50 (sgft) 48 Btuh Floors Type R-Value Size HTM Load 4 Slab On Grade 0.0 50 (ft-perimeter) 0.0 0 Btuh Floor Total 50.0 sgft 0 Btuh Zone Envelope Subtotal: 159 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 500 0.03 1.3 Load 23 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible Envelope Load: 183 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DGM of 0.160) 29 Btuh Sensible Zone Load 212 Btuh EnergyGauge® / USRCZB v7.0.00 39 April 6, 2021 Page 3 Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate:FL VERO_BEACH_MUNICIPAL A 17650 Orange Ave Orange Ave —Revised —Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Component Loads for Room #5: Bedroom 4 Type* Overhang WindowArea(sgft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshaded Shaded Unshaded 6 2 NFRC 0.17, 0.58 B-L No W 1.3ft. 2.Oft. 16.2 i 0.0 16.2 11 20 325 Btuh Window Total 16 (sqft) 325 Btuh Walls Type U-Value R-Value Area(sgft) HTM Load Cav/Sheath 8 Frame - Wood - Adj 0.09 13.010.0 135.0 1.4 192 Btuh 9 ConcreteBlk,Hollow -Ext 0.15 4.1/0.0 112.1 3.0 340 Btuh 10 ConcreteBlk,Hollow -Ext 0.15 4.1/0.0 90.0 3.0 273 Btuh Wall Total 337 (sgft) 804 Btuh Ceilings Type/Color/Surface U-Value R-Value Area sgft HTM Load 5 Unvented Attic/LighttMetal 0.241 0.0/29.0187.0 0.96 180 Btuh Ceiling Total 187 (sgft) 180 Btuh Floors Type R-Value Size HTM Load 5 Slab On Grade 0.0 187 (ft-perimeter) 0.0 0 Btuh Floor Total 187.0 sgft) 0 Btuh Zone Envelope Subtotal: 1309 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 1870 0.13 5.7 Load 101 Btuh Internal gain Occupants Btuh/occupant Appliance 1 X 230 + 1000 Load 1230 Btuh Sensible Envelope Load: 2640 Btuh Duct load Average 'sealed, Supply(R6.0-Attic), Retum(R6.0-Cond•) (DGM of 0.160 422 Btuh Sensible Zone Load 3061 Btuh Component Loads'forRoom #6: Pantry Type* Overhang WindowArea(sgft) HTM Load Window Panes SHGC U InSh IS Omt, Len H t Gross Shaded Unshaded Shaded Unshaded 7 2 NFRC 0.71, 0.58 B-L No W 1.3ft. 2.Oft. 11.6 0.0 11.6 15 46 534 Btuh Window Total 12 (sgft) 534 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 11 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 70.1 3.0 212 Btuh Wall Total 70 (sgft) 212 Btuh Ceilings 1 Type/Color/Surface U-Value R-Value Area sgft HTM Load 6 Unvented Attic/Light/Metal 0.241 0.0/29.0 128.0 .96 123 Btuh Ceiling Total 128 (sgft) 123 Btuh EnergyGauge® / USRCZB v7.0.00 40 April 6, 2021 Page 4 . $ . Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate:FL VERO_BEACH_MUNICIPAL A 17650 Orange Ave Orange Ave —Revised 1 Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Floors . 6 Type R-Value Size HTM Slab On Grade 0.0 128 (ft-perimeter) 0.0 Floor Total 128.0 sgft) Load 0 Btuh 0 Btuh Zone Envelope Subtotal: 870 Btuh Infiltration Type Wholehouse ACH Volu'me(cuft) Wall Ratio CFM= Natural 0.08 1280 0.03 1.2 Load 21 Btuh Internal gain Occupants ;Btuh/occupant Appliance 0 X 230 ,+ 700 Load 700 Btuh Sensible Envelope Load: 1591 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) I (DGM of 0.160) 254 Btuh Sensible Zone Load 1845 Btuh Component Loatls for Room #7 Bedroom 3 .. Type* - Overhang Window Area(sgft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshaded Shaded Unshaded 8 2 NFRC 0.17, 0.58 B-L No W 1.3ft. 2.Oft. 16.2 0.0 16.2 11 20 325 Btuh Window Total 16 (s' ft) 325 Btuh Walls Type U-Value R-Value Area(sgft) HTM Load ' Cav/Sheath 12 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 112.1 3.0 340 Btuh Wall Total 112 s ft 340 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sgft) HTM Load 7 Unvented Attic/Light/Metal 0.241 0.0/29.0 ;197.0 0.96 190 Btuh Ceiling Total 197 sgft) 190 Btuh Floors Type R-Value Size HTM Load 7 Slab On Grade 0.0 197 (ft-perimeter) 0.0 0 Btuh Floor Total 197.0 (sgft) 0 Btuh Zone Envelope Subtotal: 854 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 1970 0.04 1.9 Load 33 Btuh Internal gain Occupants Btuh/occupant Appliance 1 X 230 + 1100 Load 1330 Btuh Sensible Envelope Load: 2218 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DGM of 0.160) 354 Btuh Sensible Zone Load 2572 Btuh EnergyGauge® / USRCZB v7.0.00 41 April 6, 2021 Page 5 9 , Energy Code & Load Calc Package 17650 Orange Avenue -Revised Ecoinnovative 772-501-0152 Manual J Summer Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate:FL VERO_BEACH_MUNICIPAL A 17650 Orange Ave Orange Ave -Revised -Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Component Loads for Room #8:,WIC 3 Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 13 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 65.0 3.0 197 Btuh Wall Total 65 (sqft) 197 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 8 Unvented Attic/LighttMetal 0.241 0.0/29.0' 61.0 0.96 59 Btuh Ceiling Total 61 (sqft) 59 Btuh Floors Type R-Value Size .. HTM. Load 8 Slab On Grade 0.0 61 (ft-perimeter) 0.0 0 Btuh Floor Total 61.0(sqft) 0 Btuh Zone Envelope Subtotal: 256 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 610 0.03 1.1 Load 19 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible Envelope Load: 275 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Cond.) (DGM of 0.160 44 Btuh Sensible Zone Load 319 Btuh Component. Loads for Room #9: Bedroom.2 Type' Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len H t Gross Shaded Unshaded Shaded Unshaded 9 2 NFRC 0.17, 0.58 B-L No W 1.3ft. 2.0ft. 16.2 0.0 16.2 11 20 325 Btuh 10 2 NFRC 0.17, 0.58 B-L No N 1.3ft. 2.0ft. 16.2 0.0 16.2 11 11 178 Btuh Window Total 32(sqft) 502 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 14 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 112.1 3.0 340 Btuh 15 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 140.5 3.0 426 Btuh Wall Total 253 sqft) 765 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 9 Unvented Attic/Light/Metal 0.241 0.0129.0 201.0 0.96 194 Btuh Ceiling Total 201 (sqft) 194 Btuh Floors Type R-Value Size HTM Load 9 Slab On Grade 0.0 201 (ft-perimeter) 0.0 0 Btuh Floor Total 201.0 (sqft) 0 Btuh EnergyGauge® / USRCZB v7.0.00 42 April 6, 2021 Page 6 Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load -'Component Details (continued) Cesar and Marcela Martinez . Project Title: Climate:FL VERO_BEACH_MUNICIPAL A 17650 Orange Ave Orange Ave —Revised —Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Zone Envelope Subtotal: 1 1462 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 2010 •0.10 4.3 Load 75 Btuh Internal gain Occupants Btuh/occupant Appliance 1 X 230 + 1100 Load 1330 Btuh Sensible Envelope Load: 2867 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DGM of 0.160) 458 Btuh Sensible Zone Load 3325 Btuh Component Loadsrfor Room'#1Q) WIC 2= �Y � Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 16 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 66.7 3.0 202 Btuh 17 ConcreteBlk,Hollow -Ext 0.15 4.1/0.0 71.7 3.0 217 Btuh Wall Total 138 s ft 419 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 10 Unvented Attic/Light/Metal 0.241 0.0/29.0 48.0 0.96 46 Btuh Ceiling Total 48 sgft 46 Btuh Floors Type R-Value Size HTM Load 10 Slab On Grade 0.0 48 (ft-perimeter) 0.0 0 Btuh Floor Total 48.0 sgft 0 Btuh Zone Envelope Subtotal: 465 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 480 0.05 2.3 Load 41 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible Envelope Load: 507 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DGM of 0.160) 81 Btuh Sensible Zone Load 588 Btuh EnergyGauge® I USRCZB v7.0.00 43 April 6, 2021 Page 7 J Energy Code & Load Calc Package 17650 Orange Avenue -Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load Component Details (continued) Cesar and Marcela Martinez Project Title: Climate:FL VERO_BEACH_MUNICIPAL_A 17650 Orange Ave Orange Ave -Revised -Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Component Loads for Room #11: Bathroom 3 - Type" Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross ShadedUnshaded Shaded Unshaded 16 2 Low-E 0.61, 0.67 B-L No E 40.Of 2.Oft. 11.8 11.8 0.0 16 42 185 Btuh Window Total 12 (sgft) 185 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 18 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 73.2 3.0 222 Btuh Wall Total 73 (sgft) 222 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 11 Unvented Attic/Light/Metal 0.241 0.0/29.0 57.0 .0.96 55 Btuh Ceiling Total 57 (sgft) 55 Btuh Floors Type R-Value Size HTM Load 11 Slab On Grade 0.0 57 (ft-perimeter) 0.0 0 Btuh Floor Total 57.0 sgft 0 Btuh Zone Envelope Subtotal: 462 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 570 0.03 1.2 Load 22 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible Envelope Load: 484 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond,) (DGM of 0.160 77 Btuh Sensible Zone Load 561 Btuh Component Loads,for. Room #12"'`Kitchen Type" Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshaded Shaded Unshaded 11 2 NFRC 0.17, 0.58 B-L No N 10.Of 2.Oft. 23.2 0.0 23.2 11 11 255 Btuh Window Total 23 (sgft) 255 Btuh Walls Type U-Value R-Value ' Area(sqft) HTM Load Cav/Sheath 19 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 13.3 3.0 40 Btuh 20 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 23.4 3.0 71 Btuh Wall Total 37 sgft 111 Btuh Ceilings Type/Color/Surface U=Value R-Value Area(sqft) HTM Load 12 Unvented Attic/Light/Metal 0.241 0.0129.0 353.0 0.96 340 Btuh Ceiling Total 353 sgft 340 Btuh Floors Type R-Value Size HTM Load 12 Slab On Grade 0.0 309 (ft-perimeter) 0.0 0 Btuh Floor Total 309.0 (sqft) 0 Btuh EnergyGauge® / USRCZB v7.0.00 44 April 6, 2021 Page 8 J , Energy Code & Load Cale Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate: FL VERO_BEACH_MUNICIPAL_A 17650 Orange Ave Orange Ave_Revised_Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Zone Envelope Subtotal: 707 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio ' CFM= Natural 0.08 4017 0.01 0.6 Load 11 Btuh Internal, gain Occupants Btuh/occupant Appliance 0 X 230 '+ 2400 Load 2400 Btuh Sensible Envelope Load: 3118 Btuh Duct load Average sealed, Supply(R6,0-Attic), Retum(R6.0-Cond.) (DGM of 0.160 498 Btuh Sensible Zone Load 3616 Btuh ComponentkLoadsfor Room #13GreatRoom Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len H t Gross Shaded Unshaded Shaded Unshaded 12 2 NFRC 0.17, 0.58 B-L No N 10.0f 2.Oft. 23.2 0.0 23.2 11 11 255 Btuh 17 2 Low-E 0.61, 0.67 B-L No N 10.Of 2.Oft. 23.5 0.0 23.5 16 16 370 Btuh Window Total 47 (sgft) 625 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 21 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 182.4 3.0 553 Btuh Wall Total 182 sgft) 553 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 13 Unvented Attic/Light/Metal 0.241 0.0/29.0 594.0 0.96 573 Btuh Ceiling Total 594 (sgft) 573 Btuh Floors Type R-Value Size HTM Load 13 Slab On Grade 0.0 517 (ft-perimeter) 0.0 0 Btuh Floor Total 517.0 (sqft) 0 Btuh Zone Envelope Subtotal: 1750 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 6721 0.07 3.1 Load 54 Btuh Internal gain. Occupants Btuh/occupant Appliance 0 X 230 + 1000 Load 1000 Btuh Sensible Envelope Load: 2805 Btuh Duct load Average sealed, Supply(R&O-Attic), Return(R6.0-Cond.) (DGM of 0.160) 448 Btuh Sensible Zone Load 3253 Btuh EnergyGauge® / USRCZB v7.0.00 45 April 6, 2021 Page 9 u , Energy Code & Load Calc Package 17650 Orange Avenue -Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate:FL VERO_BEACH_MUNICIPAL A 17650 Orange Ave Orange Ave -Revised -Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Component Loads for Room #14t Master.Bedroom Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len H t Gross Shaded Unshaded Shaded Unshaded 13 2 NFRC 0.17, 0.58 B-L No E 1.3ft. 2.0ft. 32.4 0.0 32.4 11 20 649 Btuh 18 2 Low-E 0.61, 0.67 B-L No N 10.Of 2.01t. 23.5 0.0 23.5 16 16 370 Btuh Window Total 56 (sgft) 1019 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 22 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 144.8 3.0 439 Btuh 23 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 189.3 3.0 573 Btuh Wall Total 334 (sgft) 1012 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 14 Unvented Attic/Light/Metal 0.241 0.0/29.0 411.0 0.96 396 Btuh Ceiling Total 411 sgft 396 Btuh Floors Type R-Value Size HTM Load 14 Slab On Grade 0.0 365 (ft-perimeter) 0.0 0 Btuh Floor Total 365.0 sgft) 0 Btuh Zone Envelope Subtotal: 2427 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 3650 0.13 5.7 Load 100 Btuh Internal gain Occupants Btuh/occupant Appliance 2 X 230 + 1100 Load 1560 Btuh Sensible Envelope Load: 4087 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Cond.) (DGM of 0.160) 653 Btuh Sensible Zone Load 4740 Btuh Component Loads:for Room.#15: WIC Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 24 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 83.3 3.0 252 Btuh Wall Total 83 sgft 252 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 15 Unvented Attic/Light/Metal 0.241 0.0/29.0 140.0 0.96 135 Btuh Ceiling Total 140 sgft • 135 Btuh Floors Type R-Value Size HTM Load 15 Slab On Grade- 0.0 140 (ft-perimmeter) 0.0 0 Btuh Floor Total 140.0 sgft) 0 Btuh EnergyGaugeO / USRCZB v7.0.00 Page 10 46 April 6, 2021 Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate: FL_VERO_BEACH_MUNICIPAL A 17650 Orange Ave Orange Ave —Revised —Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Zone Envelope Subtotal: 387 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 1400 0.03 1.4 Load 25 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible Envelope Load: 412 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) DGM of 0.160 66 Btuh Sensible Zone Load 478 Btuh Component Loads for:Room'#16.Master11Bathroom Type" Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross ShadedUnshaded Shaded Unshaded 14 2 NFRC 0.16, 0.62 B-L No S 1.3ft. 2.Oft. 23.2 23.2 0.0 12 12 267 Btuh Window Total 23 (sqft) 267 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 25 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 161.7 3.0 490 Btuh 26 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 150.1 3.0 455 Btuh 27 Concrete BIk,Hollow - Ext 0.15 4.1/0.0 120.0 3:0 364 Btuh Wall Total 432 (sgft) 1308 Btuh Ceilings T e/Color/Surface U-Value R-Value Area(sqft) HTM Load 16 Unvented Attic/Light/Metal 0.241 0.0/29.0 279.0 0.96 269 Btuh Ceiling Total 279 sgft 269 Btuh Floors Type R-Value Size HTM Load 16 Slab On Grade 0.0 279 (ft-perimeter) 0.0 0 Stuh Floor Total 279.0 s ft 0 Btuh Zone Envelope Subtotal: 1844 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 2790 0.17 7.3 Load 129 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 0 Load 0 Btuh Sensible Envelope Load: 1973 Btuh Duct load Average sealed, Supply(R6.0-Attic), Retum(R6.0-Cond.) (DGM of 0.160) 315 Btuh Sensible Zone Load 2288 Btuh EnergyGaugeO I USRCZB v7.0.00 Page 11 47 April 6, 2021 3 Energy Code & Load Calc Package 17650 Orange Avenue —Revised j Ecolnnovative 772-501-0152 Manual J Summer Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate:FL_VERO_BEACH_MUNICIPAL_A 17650 Orange Ave Orange Ave —Revised —Manual J_2021 Fort Pierce, FL 34945 4/6/2021 Type* Overhang Window Area(sgft)i HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross ShadedUnshabed Shaded Unshaded 1 2 NFRC 0.16, 0.62 B-L No S 8.0ft. 5.Oft. 23.2 23.2 0.0 12 12 , 268 Btuh 2 2 Low-E 0.61, 0.67 B-L No S 8.0ft. 2.0ft. 10.0 10.0 0.01 16 18 157 Btuh. Window Total 33 (sgft) , 425 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 28 Concrete Blk,Hollow - Ext i 0.15 4.110.0 94.6 3.0 287 Btuh Wall Total 95 (sgft) 287 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sgft); HTM Load 17 Unvented Attic/Light/Metal 0.241 0.0/29.0 176.3 j 0.96 170 Btuh Ceiling Total 176 (soft) 170 Btuh Floors Type R-Value Size HTM Load 17 Slab On Grade 0.0 129 (ft-perimeter) 0.0 0 Btuh Floor Total 129.0 (sgft) 0 Btuh Zone Envelope Subtotal: 881 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.08 1677 0.04 1.6 Load 28 Btuh Internal gain Occupants Btuh/occupant Appliance 0 X 230 + 1200 Load 1200 Btuh Sensible Envelope Load: 2109 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(RU-Cond.) (DGM of 0.160) 337 Btuh I Sensible Zone Load 2446 Btuh EnergyGauge@) / USRCZB v7.0.00 Page 12 48 1 April 6, 2021 t s Energy Code & Load Calc Package 17650 Orange Avenue —Revised Ecolnnovative 772-501-0152 i Manual J Summer Calculations Residential Load - Component Details (continued) Cesar and Marcela Martinez Project Title: Climate: FL VERO_BEACH_MUNICIPAL A 17650 Orange Ave Orange Ave —Revised —Manual J_2021 Fort. Pierce, FL 34945 4/6/2021 Sensible Envelope Load All Zones 28770 Btuh Sensible Duct Load 4595 Btuh Total Sensible. Zone Loads 33366 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 33366 Btuh Totals for Cooling Latent infiltration gain (for 62 gr. humidity difference) 1848 Btuh Latent ventilation gain 0 Btuh Latent duct gain 2916 Btuh Latent occupant gain (5.0 people @ 200 Btuh per person) 1000 Btuh Latent other gain 0 Btuh Latent total gain 5764 Btuh TOTAL GAIN 39130 Btuh 1. Central Unit Rheem #RA1648AJ1 1 44500 Btuh *Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U -Window U-Factor) (Irish - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half(%s)) (Omt - compass orientation) i i EnergyGauge® / USRCZB v7.0.00 Pan crer(�r \�C MANUAL J� Page 13 49 =r April 6, 2021