HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE °� i � PermitOffice: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, - Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41718.3 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1478,30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 c NIA R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1336.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 6. Conditioned floor area above grade (ft2) 1306 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(128.9 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: 5g1, U=1.02 76.04 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 120 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.03 40.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 29.0 SEER:14.00 c. U-Factor. Sgl, U=1.02 12.85 ft2 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.281 a. Electric Heat Pump 27.0 HSPF:8.20 8. Skylights Area c. U-Factor(AVG) NIA ft2 SHGC(AVG): NIA 15. Hot water systems 9. Floor Types (1306.0 sgft.) Insulation Area a. Electric Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 1306.00 ft2 EF: 0.600 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16. Credits None Glass/Floor Area. 0.099 Total Proposed Modified Loads: 41.30 PASS S Total Baseline Loads: 43.21 I hereby certify that the plans and specifications covered by Review of the plans and Jki5 Sp this calculation are in compliance with the Florida Energy specifications covered by this _y0p Code. calculation indicates compliance �f, ' s: �� '0. with the Florida Energy Cade. � +r,•�rl.. ••, ,r.;,=?, ; n �p PREPARED BY: Before construction is completed W 34 DATE: 1-12-20 this building will be inspected for -} compliance with Section 553.908 I hereby certify that this building, as designed,_ is i ompliance With the Florida Florida Statutes. ^0 a Energy Code WF OWNERIA E T: k BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1-2). 1112/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE CO Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 1306 Lot # Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180 Street THE COTTAGE Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 LOW BLOCKS Number Name Area Volume 1 Entire House 1306 10576.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infill ID Finished Cooled Heated 1 MASTER BEDROO 234 1895.4 No 0 1 1 Yes Yes Yes 2 DEN 144 1166.4 No 0 1 Yes Yes Yes 3 SINKAREA 42 340.2 No 0 1 Yes Yes Yes 4 CLOSET 63 510.3 No 0 1 No Yes Yes 5 GREAT ROOM 452 3661.2 No 2 1 Yes Yes Yes 6 MASTER BATH 50 405 No 0 1 Yes Yes Yes 7 POWDER 25 202.5 No 0 1 No Yes Yes 8 KITCHEN 232 1879.2 Yes 0 1 Yes Yes Yes 9 LAUNDRY 40 324 No 0 1 No Yes Yes 10 STORAGE 24 192 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 31 It 0 234 ft2 __ 0 1 0 2 Slab -On -Grade Edge Insulatio DEN 24 ft 0 144 ft2 _ 0 1 0 3 Slab -On -Grade Edge Insulatio SINK AREA 7 ft 0 42 ft2 _ 0 1 0 4 Slab -On -Grade Edge Insulatio CLOSET 1 ft 0 63 IF _ 0 1 0 5 Slab -On -Grade Edge Insulatio GREAT ROOM 32 It 0 452 ft2 �_ 0 1 0 6 Slab -On -Grade Edge Insulatio MASTER BATH 5 ft 0 50 ft2 ___ 0 1 0 7 Slab -On -Grade Edge Insulatio POWDER 1 ft 0 25 ft2 0 1 0 1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY RHFrt III IST RPon RT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio KITCHEN 38 it 0 232 ft2 - 0 1 0 9 Slab -On -Grade Edge Insulatio LAUNDRY t ft 0 40 ft2 0 1 0 10Slab-On-Grade Edge Insulatio STORAGE 21 ft 0 24 ft2 _ 0 0 1 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / `� # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1306 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 234 ft2 0.1 Wood 2 Under Attic (Vented) DEN 30 Blown 144 ft2 0.1 Wood 3 Under Attic (Vented) SINK AREA 30 Blown 42 ft2 0.1 Wood 4 Under Attic (Vented) CLOSET 30 Blown 63 ft2 0.1 Wood 5 Under Attic (Vented) GREAT ROOM 30 Blown 452 ft2 0.1 Wood 6 Under Attic (Vented) MASTER BATH 30 Blown 50 ft2 0.1 Wood 7 Under Attic (Vented) POWDER 30 Blown 25 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 232 ft2 0.1 Wood 9 Under Attic (Vented) LAUNDRY 30 Blown 40 ft2 0.1 Wood 10 Under Attic (Vented) STORAGE 30 Blown 24 ft2 0.11 Wood 11 Knee Wall (Vented) GREAT ROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 S=>N Exterior Concrete Block - Int InsMASTER BE 4.1 18 0 8 1 145.5 ft2 0 0 0.3 0 2 W=>E Exterior Concrete Block - Int Ins&AASTER BE 4.1 13 0 8 1 105.1 ft2 0 0 0.3 0 3 N=>S Exterior Concrete Block - Int Insul DEN 4.1 12 0 8 1 97.0 ft2 0 0 0.3 0 _ 4 W=>E Exterior Concrete Block - Int Insul DEN 4.1 12 0 8 1 97.0 ft2 0 0 0.3 0 5 SIN Exterior Concrete Block- Int lnsiBINK AREA 4.1 7 0 8 1 56.6 ft2 0 0 0.3 0 6 N=>S Exterior Concrete Block- Int InsOREAT ROO 4.1 22 0 8 1 177.8 ft2 0 0 0.3 0 7 W=>E Exterior Concrete Block - Int InsGREAT ROO 4.1 10 0 8 1 80.8 ft2 0 0 0.3 0 8 S=>N Exterior Concrete Block- Int InsUASTER BA 4.1 5 0 8 1 40.4 ft2 0 0 0.3 0 9 N=>S Exterior Concrete Block - Int Insu1KITCHEN 4.1 17 0 8 1 137.4 ft2 0 0 0.3 0 _10 E-�W Exterior Concrete Block- Int lnsulKITCHEN 4.1 16 0 8 1 129.3 ft2 0 0 0.3 0 _ 11 S=>N Exterior Concrete Block - Int InsulKITCHEN 4.1 5 0 8 1 40.4 ft- 0 0 0.3 0 1112=21 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width SpaceArp� Height Sheathing Framing Solar Below o _12 N=>S Exterior Concrete Block - Int Insul KITCHEN 4.1 35 8 _ 13 N=>S Exterior Concrete Block - Int InsuSTORAGE 4.0999 6 8 14 N=>S Exterior Concrete Block - Int InsuSTORAGE 4.0999 5 8 15 N=>S Garage Frame - Wood MASTER BE 11 30 8 1 282.9 ft2 0 48.0 ft2 0 40.0 ft2 0 0 240.0 ft2 0 0 0.3 0 0.3 0 0.3 0.23 0.3 0 0 0 0 DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 E=>W Insulated KITCHEN None .32 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => than ed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 W=>E 2 Metal 2 W=>E 4 Metal 3 N=>S 6 Metal 4 W=>E 7 Metal 5 S=>N 8 Metal 6 E=>W 10 Metal Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.03 0.27 N Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.02 0.26 N 32.4 ft2 1 ft 5 in 1 ft 5 in 18.4 ft2 1 ft 5 in 1 ft 5 in 18.4 ft2 1 ft 5 in 1 ft 5 in 40.0 ft2 12 ft 0 in 1 ft 5 in 6.9 ft2 1 ft 5 in 1 ft 5 in 12.8 ft2 1 ft 5 in 1 ft 5 in None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 ft2 280 ft2 35 ft 8.1 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000257 881.4 48.35 90.78 .0907 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.2 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 14 29 kBtu/hr cfm 0.8 1 Sys #1 1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT RI IMMARY rl4 =ruI IST RF®nOT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Can # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply — V — Return— Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 120 ft2 Attic 45 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Crreiling Fans: Coolin Jan Feb Venting Jan F b Mar Mar Apr ADec May Jun [ Nov[(X]�rDO, Nov [ ]X pr [ Jul Aug Sap Occtt [ ]X [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 12 Oft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 It 0.3 DEN Default(8 lbs/sq.ft. ft2 ft 0.3 SINK AREA Default(8 lbs/sq.fL ft2 ft 0.3 CLOSET Default(8 lbs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(81bs/sq.ft. ft2 it 0.3 MASTER BATH Default(8 lbs/sq.ft. ft 0.3 POWDER Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. 0 ft2 Oft 0.3 STORAGE 1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y Owner. WYNNE BUILDING CORP. Jurisdiction: w Design Location: FL, Fort Pierce = O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed- Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including above -garage insulation. maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity Spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall pipil2a and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and -e2deadjaab= Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. ui auumm i, nispecwn of wy waus span be in accordance wmn the provision or Il:(r4W. 1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. THE COTTAGE, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1478.30 T 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 240.00 it- c NIA R_ ft' 4. Number of Bedrooms 1 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area 6. Conditioned floor area (W) 1306 a. Under Attic (Vented) R=30.0 1306.00 ft2 b. Knee Wall (Vented) R=19.0 30.00 ft2 T. Windows** Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=1.02 76.04 ft2 12. Ducts, location & insulation level R fP SHGC: SHGC=0.29 a. Sup: Attic, Ret Attic, AH: Attic 6 120 b. U-Factor. S91, U=1.03 40.00 ft2 SHGC: SHGC=0.27 c. U-Factor. Sgl, U=1.02 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=026 12.85 ft' a. Central Unit 29.0 SEER,14.00 d. U-Factor. N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.701 it a. Electric Heat Pump 27.0 HSPF:820 Area Weighted Average SHGC: 0.281 8. Skylights Description Area 15. Hot water systems a. U-FactogAVG): N/A ft2 a. Electric Cap: 1 gallons SHGC(AVG): N/A EF: 0.6 9. Floor Types YP Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1306.00 ft2 None b. N/A R= ftz Credits (Performance method) None c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code complia2nttfe ES - Builder Signature: Date:\� Address of New Home: ^� City/FL Zip: Ste, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsoft` Project Summary Job: Entire House Date ` QUICK CALCS, INC. 317ST. LUCIE LANE, FORTPIERCE, FL34W PhDM:772466-6799 Email: QUICKCALCS@AOL.CONI - • • 11,11 For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Notes: A v- Desiqn Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Inside db 70 °F Outside db OF 75 Design TD 28 OF Inside db Design TD OF 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Duds Structure 15522 Btuh 4013 Btuh Central vent (0 cfin) 0 Btuh Duds Central vent (0 cfin) 5251 Btuh (none) Humidification 0 Btuh (none) Blower 0 Btuh 0 Btuh Equipment load 20340 Btuh Use manufacturer's data Infiltration Rate/swing multiplier Equipment sensible load n 0.95 19734 Btuh Method Simplified Construction quality Average Fireplaces Latent Cooling Equipment E p Load Sizing 0 Structure 2094 Btuh Ducts Central vent (0 cfin) 1524 Btuh 0 Btuh Heatingg Coolingg Area 1306 1306 (none) Equipment latent load 3618 Btuh Volume (fta) 10579 10579 Airchanges/hour OA5 0.23 EquivA/F(cfm) 79 Equipment Total Load (Sen+Lat) 23352 Btuh 41 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIER Make Carrier Trade CARRIER Model CH14NBO3000GOA0 AHRI ref 9162387 Cond CH14NBO3000GOAD Coil FX4DNB043L Efficiency 8.2 HSPF AHRI ref 9162387 Efficiency 11.5 EER,14 SEER Heating Input Heating output 28000 Btuh@470F Sensible cooling Latent cooling 20300 Btuh 8700 Btuh Temperature rise 26 OF Adualairflow 967 cfm Total cooling Actual 29000 Btuh Air flow factor 0.048 cfm/Btuh Static 0.50 airflow Airflowfactor 967 cfin 0.047 cfnBtuh pressure in H2O Space thermostat Static pressure Load sensible heat ratio 0.50 in H2O 0.85 Capacity balance point = 34 OF Ba p5 Innpuutt kW, Output=18005 Btuh, 100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -" wnPghtsofY 2021Jan121321:40 "°1`^ft RigFtSute�JUriversa1201919.021 RSU08101 ...1Wngtisoft HVAQWYNNEBUIDLING-THECOTrAGEnp Calc=NUB %rt Doorfaws:SN! Pagel wrightsolt° RighW@ Worksheet Job. Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LANE, FORTMERCE, FL34946 Phom:772466-6799 Email: QUICKCALCS AOL.COM 1 Room name Enfina Houee MASTER BEDROOM 2 Eposed wall 145.0 It 31.0 ft 3 Room height 8.1 it 8.1 ft heakool 4 Room dimensons 13A z 18.0 it .Room area 1306.0 ft' 234.0 fl' Ty Construction U-value Or HTM Area Load number (Btuh4C--°F) (BW111F) or perimeeLr M (BWh) or�perimeetter (it) (Stuh) Heat Cool WP/S Heat Cool Heat Cool 6 VN 13A-0as 0.143 n 4.00 2.19427 1710 9340 0 P913A-0 tlroutr, 1.040 n 29.12 21.68 0 537 4000 0 0 0 0.143 a 4.00 2.19129 516 2820 0 0 2 glaang,droutr, 1.040 a 29.12 39.422 368 4980 0 0 11 11D0 0.390 a 10.92 10.3420 223 2110 0 0 1M 13A�ors 0.143 s 4.00 2.19277 1107 6056584319I—G 1.040 s 29.12 21687 202 1W0 0 0 1gtlroutr, 0.143 w 4.00 2.19192 767 4193 291 159 1Aciom 1270 w 3556 34.7741 1451 14190 0 0 1A-hlom 1270 w 3556 61.763 T 656 11390 Tn 0 0 lA-hlom 1270 w 35.56 63.405 1162 20725 1162 2072 C F 16C.30m1 22A-yl 0.032 - 0.90 1281306 117( 16T4 210 300 0.989 - 27.69 0.00145 i 4015 I 1 01 858 0 6 c)AED exalrson 3591 997 Envelope lossligain 13885 13393 3105 3847 12 a) Infilhalion b) RoornwhIlafion 2441 668 522 143 0 0 0 0 13 Internal gains: O=Panta@ 230 2 460 0 Applianoe:lJother 1000 0 0 Subtotal(lines6to 13) 16327 15522 3627 3990 Lese#emzlload 0 0 0 0 I-miansler 0 0 Redistribufion 0 0 0 0 14 15 Subtotal Ductloads 16327 15522 3 0 25% 34% 4013 5251 25% 34% 892 892 13990 3520 1352 Total room load 20340 20773 4 s3415 Air required(dm 967 967 21) gas9 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wr/ghLsolY^ 2021-Jar121321:40 ACCA RNG-TH f COTr GE.n 01919.021 RSWSIDt Page 1 ...\Wrighbft HUACIWYNNE BUIDLING-THE COTTAGE.rup Calc=M18 FroRDoorfaoas:SW + wrigbwow Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Em if:QUICKC4LC8@AOL.COM 1 Room name DEN SMKAREA 2 Exposed wall 24.0 ft 7.0 ft 3 Room height 8.1 ft heaVmol 8.1 ft heaVmol 4 Room dimensons 72.0 x 12.0 ft 6A z 7.0 ft 5 Room area 144.0 ft` 42.0 iF Ty Construction U-value Or HTM Area (fF) Load Area (115 Load number (BIuhAF-°F) (BhWhgF) or penmeter (ft) (BWh) or perimeter (ft) (Bhrh) Heat Ccol Gros N/P/9 Heat Cool Gross N/P/3 Heat Cool 6 Vl1 �G 13A-4ors 0.143 n 4,00 2.19 97 97 389 213 0 0 0 0 2glaang,droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 a 0 13A-0ors 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 11 1100 0390 a 10.92 10.34 0 0 0 0 0 0 0 0 lM t-G 1344o s 0.143 s 4.00 2.19 0 0 0 0 57 57 227 0 0 124 2glazirg,droutr, 1A40 s 29.12 21.68 0 0 0 0 0 13A4oa 0.143 w 4.00 2.19 97 79 315 172 0 0 0 0 1Aclom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A-hlom 1270 w 35.56 61.76 18 3 656 7139 0 0 0 0 1A.hlom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 c 16C-30ml 0.032 - 0.90 128 144 144 129 184 42 42 38 54 F 22A->pl 0.989 - 27.69 0A 144 24 665 0 1 a2 7 794 0 6 c)AED emurscn 574 .3 Envelope loss(gain 2154 2283 459 775 12 a) IMltiafion 404 ill 118 32 b) Rcomlenfabon 0 0 0 0 13 IMemal gains: Caapants@ 230 0 0 0 Appliancz;lother 0 0 0 Subbtal(lines6to13) 2558 2394 576 207 Lesexemalload 0 0 0 0 s Letiansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subotal 2558 2394 576 207 15 Ductloads 25% 34% 629 817 25°/, 34% 142 70 70 Total room load 3187 3205 7 278 Air required(Um) 152 149 34 13 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wrllaht zoI° 2021-Jan121321:40 PjgttSUte@Uriverwl20l9l9.O2l RSU06707 Fage2 ...1Wdgttoft HVAQWYNNEBUIDLING-THECOT7AGE.np Calc=MJB Fror;Doorfaoss SW wrightsofr Right-M Worksheet Job. Entire House Date: QUICK CALCS, INC. By.. 317ST. LUCIE LANE, FORTMERCE, FL34M Phore: 772-466-6799 Emai1:QUlCKCALCS(EAOL.00rd 1 Room name CLOSET 2 E)posed Hall GREAT ROOM 0 ft 3 Room height 8.1 ft heatbool 1 32.0 It 8.1 itheal/ocol 4 Room dimensions 9.0 x 7.0 ft 5 Room area 10 x 452.0 ft 63.0 rF 452.0 fN Ty Construction U-value Or HTM Area (fF) Load Load number (ayh4F--°r7 (BluhAF) or penmeter (R) (6Wh) oorpenm�r (ft) (Bhth) Heat Cool Gros N/P/S Heat Cool Gros N/P/S Heat Cool 6 VN 13A4os 2gl3A-flocs 0.143 n 4D) Z19 0 0 0 0 178 160 640 35p , 1.040 0.043 a a 24.00 4.00 22.19 2.19 0 0 0 0 0 0 18 0 530 400 2 glazing, tlroutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 0 0 11 I� 11D0 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 0 VN lak4ors 0.143 s 4.00 2.19 0 0 0 0 0 0 0 13gIA�'tlroutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 0 0 0 0.143 w 4.00 2.19 0 0 0 0 81 40 0 1Aclom 1Ahlom 1270 w 35.56 34.77 0 0 0 0 41 41 1451 151 88 1419 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1Ahlom 1270 w 3556 63.40 0 0 0 0 0 0 0 C F 16Ca0ml 22A-tpl 0.032 - 0.90 128 63 63 5( 81 452 4521 405 0 579 0.989 - 27.69 0.00 63 0 0 0 45, 32 886 0 6 c)AEDemursion 1 2069 Envelope loss/gain 56 SO 4080 4903 12 a) Infiltraton 0 0 b) Roomventilation 539 148 0 0 0 0 13 Intemaigains: Oaupants@ 230 0 0 2 Applianoas/other 460 0 0 Sub47fal (linss6 to 13) 5611 80 4619 5571 Lesexamal load 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 14 Subtotal 56 40 5511 15 Duct loads 25Y 34% 14 27 25% 34°/, 7135 135 1868 7868 Total room load Air required(cfm) 70 107 5 734 3 5 274 34343 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed _A ... RgHrl 201919.RS12021.krF121321 R0 \Wngt6oRHVACWYNNEBUIDLING-THECOTTAGE.Rp Calc=Ma FmqDoorfaQs:SW Page 3 wrightsoft° Right-M Worksheet Job." Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phone: 772-466-6799 Emil: OUICKCALCSCAOL.COM 1 Room name MASTER BATH POWDER 2 Fponed wall 5.0 It 0 ft 3 Room height 8.1 It heaVocoi 8.1 It heaVocol 4 Room din`7.Ons 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Roomarea 50.0 tf 25.0 IF Ty Construction U-�Iue Or HTM Area (fF) Load Area number (BWh4F2F) (BWh4t=) or penmeter (ft) (BWh) or perimeter (ft) (Bhrh) Hea[ Cool Gross NIPS Heat Cool Gras NIPS Heat Cool 6 U}/ 13A-4ors 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 �C 2glaang, tlroutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-4as 0.143 e 4A0 2.19 0 0 0 0 0 0 0 0 2glazing, droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 71 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 s 4.00 2.19 41 34 134 73 0 0 0 0 -4 2glazing, droutr, 1.040 5 29.12 21.68 7 7 202 150 0 0 0 0 13A4= 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Aclom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A-Morn 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 lA-hlom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0.90 128 50 50 45 64 25 25 22 32 F 27A-01 0.98E - 27.69 0.00 5( 5 138 0 25 0 0 0 6 c)AED excursion -4 0 Ernrelopeloss/gain 520 284 22 32 12 a) Infiltration 84 23 0 0 b) Room eentlation 0 0 0 0 13 ntemal gains: Oavpants@ 230 0 0 0 0 Appliance,4olher 0 0 Subtotal(lines6to 13) 804 307 1 22 32 Les eadamal load 0 0 0 0 Lesstran�r 0 0 0 0 Redisbibufion 0 0 0 0 14 Subtotal 604 30 22 32 15 Dudioads 25% 34% 148 104 25% 34% 6 11 Total room load 736 411 28 4z Airrequired(dm) 36 19 Calculations approved byACCAto meet Eli requirements of Manual J 8th Ed -FId- ...w !gk!!Eon RgH9.021RSU081 2021-Jan121321:40Ask\WngEnftHVACWYNNEBUIOLING-THErO7rAGE..rLp Calc=M)8 FrortOoorfaces:SW Page wrightsoft• Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772.466-6799 Email:OUICKCALCSa@ACL.COM 1 Room name 2 Eoposedwall ITI-CHEN LAUNDRY 3 Room height 38.9 ft 8.1 ft hea%ocol 0 ft 8.1 ft heatlmol 4 Room dimensions 1D x 232.0 ft 4.0 x 10.0 ft 5 Room area 232.0 ft' 40.0 ff Ty Construction U-value Or HTM Area Load Load number (Bluh*ft F) (aWhm') or perimeter (ft) (BWh) or�perimet r M (BWh) Heat Cool Gros NIPS Heat Cool Gross N/RIS Heat Cool 6 l4/ �-C 13A-4ocs 0.143 n 4.00 2.19 138 138 551 301 0 0 0 2glazing, droutr, 13A-4= 1.040 0.143 n a 29.12 4.00 21.68 2.19 130 0 97 0 0 0 0 0 0 0 2glaang,droud,, 1.040 a 29.12 39.42 13 387 2 368 211 498 0 0 0 0 0 11 11D0 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 0 0 0 lM 13A-4= 0.143 s 4.00 2.19 41 41 162 89 0 0 L---G 2glaarg,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 13A-4o � 0.143 w 4.00 2.19 0 0 0 0 0 0 0 1Aclom 1270 w 35.56 3477 0 0 0 0 0 0 to-hlom 1270 w 3556 61.76 0 0 0 0 0 0 1A-hlom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16CJOml 0.032 - 0.9C 128 232 232 208 297 40 40 36 0 0 F 22A-tpl 0.989 - 27.69 0.(0 232 38 1052 0 40 0 51 1 1 0 0 6 C)AED e=rson -37 -1 Envelope loss�gain 2951 1570 36 51 12 a) Infiltration 640 175 0 0 b) Roomeentlaton 0 0 0 0 13 Inhmal gains O=pants@ 230 0 0 0 Applianordother I 1000 0 0 Subtotal (lines6to 13) 3591 2745 36 51 Less extemal load 0 0 Lestrarsfer 0 0 0 0 Redistribufion 0 0 14 Subtotal 3590 2745 0 39 0 51 15 Dud loads 25% 34% 863 931 25%. 34% 9 17 Total room load 4474 3676 1 45 68 Air required (dm) 213 171 2 3 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed -+�' wrlghfsoft^ 2021Jan-121321:40 Rigt-THr C U TAGr. ip Calc.0218 Frort o Page 5 ...1WrigtLsoftHVAC\WYNNE BUIDLMG-THE COTTAGE.np CaIc=NJB Frort Doortaces:SW wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Emaa:OUICKCALCS@ACL.COM 1 Room name STORAGE 2 Exposedwall 8.0 It 3 Room height 81 a healfmlol 4 Room dimensions 4.0 x 6.0 it I 5 Room area 24.0 1' Ty Construction U-value Or HTM Area d Ar Load number I (BWhXF-°F� (BWhAF) or perimeter (ft) (Bvh) ors perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Ufl 13A-4= 0.143 n 4.p0 2.19 32 32 130 71 2 g13A-0' tlroutr, 1.040 0.143 n a 29.72 4.00 2.19 2219 32 0 32 0 0 0 2 glazing, drout', 1.040 a 29.12 39.42 0 130 0 71 0 71 11DO 0.390 a 10.92 10.34 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 2g13droutr, 1.040 s 29.12 21 b8 0 0 0 0 0.743 w 4.00 2.19 0 0 0 D 1Aclom 1270 w 35.56 34.19 0 0 0 0 IA-hlom 1270 w 35.56 61.76 0 0 0i 0 1A-h1om 1270 w 3556 63.40 0 0 0 0 C 16C30m1 0.032 - 020 128 24 24 22 31 F 22A-tpl 0.989 - 27.69 0.00 24 8 222 0 6 c)AEDex on 3 Envelope loss/gain soz no 12 a) Infiltration 135 37 b) Roomvenfilafion 0 0 13 Intemalgaim O=pants@ 230 0 0 Appliancas(other g Subtatal(hnes6t>13) 637 207 Lese)emal loaf 0 0 Lestransfer 0 0 Redistribution 0 0 14 Subtotal 67 207 15 Dudloads 25% 29% 757 60 60 Total room load 794 266 Air required (dm) 38 12 Calculations approved bvACCAto meetall requirements of Manual J 8th Ed -F}F wNg -- dC A ...kgtt9.021 RSU06ID7 2021-Jarvi21321.40 1Wng6oftM/ACMYNNESUIDLING-THEOOTrAGE..np CaIc=NB FrottDoorfacesSN/ Page -- wrightsoft® Duct System Summary Date: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phore:7724666799 Email: QUICKCALCS@AOL.COM For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 dim 126 Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk CLOSET DEN C 107 3 5 0.080 4.0 Ox0 VIFx 24.6 90.0 st1 ROOM h 3187 C 3689 152 149 0.080 7.0 Ox0 VIFx 33.5 0.0 990.0 SO GREAT ROOhI-A c 3689 137 137 172 172 0.080 0.080 8.0 8.0 Ox0 VIFx 14.6 KfrCHEN h 4474 213 171 0.080 7.0 Ox0 Ox0 VIFx VIFx 16.1 4.5 70.0 LAUNDRY C 68 2 3 0.080 4.0 Ox 0 VIFx 5.4 70.0 70.0 MASTERSATH MASTERSEDROOM h 752 36 19 0.080 4.0 OxO VIFx 32.9 90.0 MASTERBEDROOM-A c 2671 107 124 0.080 7.0 OxO VIFx 27.9 90.0 st1 POWDER c 2671 107 124 0.080 7.0 0x0 VIFx 35.9 90.0 st1 SINK AREA C 42 h 1 2 0.080 4.0 OxO VIFx 29.2 90.0 st1 st1 STORAGE 718 h 794 34 13 0.080 4.0 OxO MFx 30.9 90.0 st1 W 12 0.080 4.0 OxO VIFx 11.2 70.0 Lame Trunk Type Htg (Cfm) Clg (Cfm) Design FIR(fpm) Veloc Diam (in) H x W (in) Dud Material Trunk PeakAVF 441 437 0.080 561 12.0 0 x 0 V nlFlx wrightsow 2021Ja,121321:41 •Wu-� ..•-..�.., Rgrt-Stite@Uriveml20l9l9.021RSU08101 A Paget ...\WrgrtsoftWAQWYNNEBUIDLING-THECOTrAGE.rtp Calc=MJB Frort DDorfams:SW Return Branch Detail Table Name Grille Size (in) Htg (dm) Clg (cfm) TEL 00 Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (n) Duct Macb I Trunk rbl OxO 967 967 1 0 J 0 0 0 Ox 0 1 MFx -0 ld- Wright50ft- 2021-Jarv121321:41 • � «�-+�. Mgft-SUbla UdwrM1201919.021 RSUDS101ACM Paga2 ...\WrigHmft WACkWYNNESUIDLING-7HECOTTAGE.rip CaIc=M18 Frort Doorfaces:SW