HomeMy WebLinkAboutEnergy Code,r
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional
Regulation - Residential Performance
Method
Project Name: Lot 24 Block 2 Waterstone 2265 AGL
Builder Name: ADAMS HOMES
Street: 8304 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV028.2 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1378.30 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Exterior
R=13.0 407.83 ft2
c. Frame - Wood, Adjacent
R=13.0 242.00 ft2
4. Number of Bedrooms 4
d. N/A
R=
5. Is this a worst case? No
11. Ceiling Types (2381.0 sqft.)
ft2
Insulation Area
6. Conditioned floor area above grade (ft2) 2281
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 2281.00 ft2
R=19.0 100.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(306.4 sqft.) Description Area
12. Ducts
. R ft2
a. U-Factor: Dbl, U=0.33 166.06 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 f:2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 51.11 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 5.808 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.309
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
9. Floor Types (2281.0 sqft.) Insulation Area
a. Electric
Ca 40
p gallons
a. Slab -On -Grade Edge Insulation R=0.0 2281.00 ft2
ti. Conservation features
EF: 0,940
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.134 Total Proposed Modified Loads: 66.26
PASS
Total Baseline
Loads: 68.54
I hereby certify that the plans an a tions covered b
Review the plans andST9
this calculation are in complia ,V ' gy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
un, ��•, ,t �* • "„p
PREPARED BY:
Before construction is completed
DATE: n3_11_9n21 1A/inn Keonnany
this building will be inspected for
compliance with Section 553.908
I herebycertify that this building, as designed, is in compliance
fI/ 9, 9 p;
the Florida�Pner
Florida Statutes.
,. Al
with
CoOWNER/AGET7
BUILDING OFFICIAL:
DATE: -
DATE:
- kompuance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 rACH50 (R402.4.1.2).
FILE AGYI/E�d 1= COPY
CODE COMPLIANCE
3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202e'rl 7tI E i j) Iif Nevft`rry Page 1 of 5
LSOCCS�t q7
FORM R405-2020 IAIPI IT CI IIIAIIAAOV flUcr%wl rc-r orrne%nT
PROJECT
Title:
Lot 24 Block 2 Waterstone 22 Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2281
Lot #
24-2
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8304 Amalfi Circle
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce
Family Type:
Detached
,
New/Existing:
New (From Plans)
FL, 34951
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design Daily Temp
v Design
Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days
Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH _MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2281 20529
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2281 20529 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0
2281 ftz ----
0.35 0 0.65
ROOF
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2550 ftZ 570 ftZ Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2281 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2281 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
100 ftZ 0.11
Wood
3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FOkM R405-9090 IAIDI IT CI IIIAIIAA13V /+L111="W1 11c+7- r,.-r....
v..w.��.v. mil. -I -
WALLS
Adjacent
Space
Cavity
-
Width
Height
Sheathing Framing Solar Below
o
1
W Exterior Frame - Wood
Main
13
10
2
8 0
81.3 ft2
0
0.23 0.6 0
2
W Exterior Concrete Block - Int
Insul .Main
4.1
38
7
10 0
385.8 ft2
0
0 0.6 0
3
S Exterior Frame - Wood
Main
13
4
6
10 0
45.0 ft2
0
0.23 0.6 0
4
S Exterior Concrete Block - Int
Insul Main
4.1
28
6
10 0
285.0 ft2
0
0 0.6 0
5
E Exterior Frame - Wood
Main
13
6
9
8 0
54.0 ft2
0
0.23 0.6 0
6
E Exterior Concrete Block - Int
Insul Main
4.1
50
3
8 0
402.0 ft2
0
0 0.6 0
7
NE Exterior Frame - Wood
Main
13
3
10
10 0
38.3 ft2
0
0.23 0.6 0
8
NE Exterior Concrete Block - Int
Insul Main
4.1
0
5
10 0
4.2 ft2
0
0 0.6 0
9
N Exterior Frame - Wood
Main
13
18
11
10 0
189.2 ft2
0
0.23 0.6 0
10
N Exterior Concrete Block - Int
Insul Main
4.1
37
8
8 0
301.3 ft2
0
0 0.6 0
11
- Garage Frame - Wood
Main
13
30
3
8 0
242.0 ft2
0
0.23 0.01 0
DOORS
# Ornt Door Type
Space
Storms
U-Value
Width
Height Area
Ft In
'Ft In
1 S Insulated
Main
None
.25
-3
6 8 20 ft2
2 - Wood
Main
None
.25
2
8
6 8 17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade Screening
1
W 1 Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft2
23 ft 0 in
0 ft 9 in
Drapes/blinds Exterior 5
2
W 2 Vinyl Low-E Double
Yes
0.33
0.23
N
32.4 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds Exterior 5
3
S 3 Vinyl Low-E Double
Yes
0.33
0.31
N
5.0 ft2
7 ft 8 in
0 ft 6 in
None None
4
S 4 Vinyl Low-E Double
Yes
0.33
0.31
N
13.3 ft2
7 ft 8 in
2 ft 10 in
None None
5
S 4 Vinyl Low-E Double
Yes
0.33
0.21
N
32.4 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds Exterior 5
6
S 4 Vinyl Low-E Double
Yes
0.33
0.21
N
38.5 ft2
1 ft 0 in
2 ft 10 in
Drapes/blinds Exterior 5
7
E 5 Vinyl Low-E Double
Yes
0.55
0.7
N
15.6 ft2
23 ft 0 in
0 ft 9 in
Drapes/blinds Exterior 5
8
E 6 Vinyl Low-E Double
Yes
0.33
0.23
N
9.8 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds Exterior 5
9
E 6 Vinyl Low-E Double
Yes
0.33
0.23
N
16.2 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds Exterior 5
10
NE 7 Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ft2
11 ft 0 in
0 ft 4 in
Drapes/blinds Exterior 5
11
N 9 Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 4 in
0 ft 9 in
Drapes/blinds Exterior 5
12
N 9 Vinyl Low-E Double
Yes
0.33
0.23
N
16.7 ft2
6 ft 8 in
0 ft 4 in
Drapes/blinds Exterior 5
13
N 9 Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 4 in
0 ft 4 in
Drapes/blinds Exterior 5
14
N 10 Vinyl Low-E Double
Yes
0.33
0.23
N
48.6 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds Exterior 5
3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORIA R405-2020 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
476 ftZ
476 ftz
64 ft 8 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2395.1 131.4 246.69 .1324 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 35 kBtu/hr cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert #
Company Name
System Model # Collector Model # Area Volume FEF
None
None
ft'
DUCTS
/
---- Supply ----
---- Return ---- Air CFM 25 CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 456.2 ft Main
114.05 Default Leakage Main (Default) (Default)
1 1
3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 IAIDI IT CI IneeeAov r+u=nv.
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan
Heating Jan
Venting Jan
Feb
X Feb
Feb
j Mar
X] Mar
Apr
APr
f
Ma X Jun
May f l Jun
Jul
1XIJul
Au
rj Au
Se
SeP
rj
Oct
Oct
Nov
Nov
Dec
Dec
[
X Mar
[
A r
[
Ma [ Jun
Jul
Aug
Se
[X] Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78 78
78
78
78
80
80
80
80
78
78 78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78 78
78
78
78
78
78
78
78
78
78
78 78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
66 66
68
68
68
68
68
68
68
68
68 68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
66 66
68
68
68
68
68
68
68
68
68 68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
8304 Amalfi Circle, Fort Pierce, FL, 34951
1. New construction or existing New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1378.30 ftZ
3. Number of units, if multiple family 1
b. Frame - Wood, Exterior
R=13.0
407.83 ftZ
c. Frame - Wood, Adjacent
R=13.0
242.00 ftZ
4. Number of Bedrooms 4
d. N/A
R=
ftZ
5. Is this a worst case? No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2281.00 ftZ
6. Conditioned floor area (ftZ) 2281
b. Knee Wall (Vented)
R=19.0
100.00 ftZ
7. Windows- Description
Area
c. N/A
R=
ftZ
a. U-Factor: Dbl, U=0.33
166.06 ftZ
12. Ducts, location & insulation level
R ftZ
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
b. U=Factor: Dbl, U=0.33
70.92 ftZ
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
C. U-Factor: Dbl, U=0.55
51.11 ftZ
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.70
-
d. U-Factor: other (see details)
18.33 ftZ
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
5.808 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average SHGC:
0.309
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ftZ
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types Insulation
Area
b. Conservation features
a. Slab -On -Grade Edge Insulation R=0.0
2281.00 ftZ
None
b. N/A R=
ftZ
Credits (Performance method)
Pstat
c. N/A R=
ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: I Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1