Loading...
HomeMy WebLinkAboutEnergy Code,r FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 24 Block 2 Waterstone 2265 AGL Builder Name: ADAMS HOMES Street: 8304 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV028.2 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=13.0 407.83 ft2 c. Frame - Wood, Adjacent R=13.0 242.00 ft2 4. Number of Bedrooms 4 d. N/A R= 5. Is this a worst case? No 11. Ceiling Types (2381.0 sqft.) ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 2281 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 2281.00 ft2 R=19.0 100.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(306.4 sqft.) Description Area 12. Ducts . R ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 456.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 f:2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 51.11 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 5.808 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.309 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (2281.0 sqft.) Insulation Area a. Electric Ca 40 p gallons a. Slab -On -Grade Edge Insulation R=0.0 2281.00 ft2 ti. Conservation features EF: 0,940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.134 Total Proposed Modified Loads: 66.26 PASS Total Baseline Loads: 68.54 I hereby certify that the plans an a tions covered b Review the plans andST9 this calculation are in complia ,V ' gy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. un, ��•, ,t �* • "„p PREPARED BY: Before construction is completed DATE: n3_11_9n21 1A/inn Keonnany this building will be inspected for compliance with Section 553.908 I herebycertify that this building, as designed, is in compliance fI/ 9, 9 p; the Florida�Pner Florida Statutes. ,. Al with CoOWNER/AGET7 BUILDING OFFICIAL: DATE: - DATE: - kompuance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 rACH50 (R402.4.1.2). FILE AGYI/E�d 1= COPY CODE COMPLIANCE 3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202e'rl 7tI E i j) Iif Nevft`rry Page 1 of 5 LSOCCS�t q7 FORM R405-2020 IAIPI IT CI IIIAIIAAOV flUcr%wl rc-r orrne%nT PROJECT Title: Lot 24 Block 2 Waterstone 22 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2281 Lot # 24-2 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8304 Amalfi Circle Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Detached , New/Existing: New (From Plans) FL, 34951 Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH _MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2281 20529 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2281 20529 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0 2281 ftz ---- 0.35 0 0.65 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2550 ftZ 570 ftZ Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2281 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2281 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 100 ftZ 0.11 Wood 3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FOkM R405-9090 IAIDI IT CI IIIAIIAA13V /+L111="W1 11c+7- r,.-r.... v..w.��.v. mil. -I - WALLS Adjacent Space Cavity - Width Height Sheathing Framing Solar Below o 1 W Exterior Frame - Wood Main 13 10 2 8 0 81.3 ft2 0 0.23 0.6 0 2 W Exterior Concrete Block - Int Insul .Main 4.1 38 7 10 0 385.8 ft2 0 0 0.6 0 3 S Exterior Frame - Wood Main 13 4 6 10 0 45.0 ft2 0 0.23 0.6 0 4 S Exterior Concrete Block - Int Insul Main 4.1 28 6 10 0 285.0 ft2 0 0 0.6 0 5 E Exterior Frame - Wood Main 13 6 9 8 0 54.0 ft2 0 0.23 0.6 0 6 E Exterior Concrete Block - Int Insul Main 4.1 50 3 8 0 402.0 ft2 0 0 0.6 0 7 NE Exterior Frame - Wood Main 13 3 10 10 0 38.3 ft2 0 0.23 0.6 0 8 NE Exterior Concrete Block - Int Insul Main 4.1 0 5 10 0 4.2 ft2 0 0 0.6 0 9 N Exterior Frame - Wood Main 13 18 11 10 0 189.2 ft2 0 0.23 0.6 0 10 N Exterior Concrete Block - Int Insul Main 4.1 37 8 8 0 301.3 ft2 0 0 0.6 0 11 - Garage Frame - Wood Main 13 30 3 8 0 242.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In 'Ft In 1 S Insulated Main None .25 -3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 23 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 2 W 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 S 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 7 ft 8 in 0 ft 6 in None None 4 S 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 7 ft 8 in 2 ft 10 in None None 5 S 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 6 S 4 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 0 in 2 ft 10 in Drapes/blinds Exterior 5 7 E 5 Vinyl Low-E Double Yes 0.55 0.7 N 15.6 ft2 23 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 8 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 9 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 10 NE 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 11 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 11 N 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 4 in 0 ft 9 in Drapes/blinds Exterior 5 12 N 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft2 6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5 13 N 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 4 in 0 ft 4 in Drapes/blinds Exterior 5 14 N 10 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORIA R405-2020 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 476 ftZ 476 ftz 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2395.1 131.4 246.69 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1 3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 IAIDI IT CI IneeeAov r+u=nv. TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Heating Jan Venting Jan Feb X Feb Feb j Mar X] Mar Apr APr f Ma X Jun May f l Jun Jul 1XIJul Au rj Au Se SeP rj Oct Oct Nov Nov Dec Dec [ X Mar [ A r [ Ma [ Jun Jul Aug Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 8304 Amalfi Circle, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ftZ 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=13.0 407.83 ftZ c. Frame - Wood, Adjacent R=13.0 242.00 ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2281.00 ftZ 6. Conditioned floor area (ftZ) 2281 b. Knee Wall (Vented) R=19.0 100.00 ftZ 7. Windows- Description Area c. N/A R= ftZ a. U-Factor: Dbl, U=0.33 166.06 ftZ 12. Ducts, location & insulation level R ftZ SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 456.2 b. U=Factor: Dbl, U=0.33 70.92 ftZ SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency C. U-Factor: Dbl, U=0.55 51.11 ftZ a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.70 - d. U-Factor: other (see details) 18.33 ftZ SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 5.808 ft. a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.309 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ftZ a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 2281.00 ftZ None b. N/A R= ftZ Credits (Performance method) Pstat c. N/A R= ftZ I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: I Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/11/2021 12:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1