HomeMy WebLinkAboutRevison OFFICE USE ONLY:
DATE FILED: /—• PERMIT# 2105-0715
REVISION FEE: •7S RECEIPT#
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772)462-1553
APPLICATION FOR BUILDING PERMIT R I
Mgt
PROJECT INFORMATION
LOCATION/SITE �..
ADDRESS:
425 BARTOW ST
DETAILED DESCRIPTION OF PROJECT File Copy
p�
CHANGING PRODUCT APPROOOOVAL FOR UNDERLAYMENT
u'AAC 1011 r
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1330653 ST. LUCIE CO CERT. #:
BUSINESS NAME: TREASURE COAST ROOFING
QUALIFIERS NAME: BRIAN MALONEY
ADDRESS. 1816 SW BILTMORE ST
CITY: PORT ST LUCIE STATE: FLORIDA ZIP: 34984
PHONE(DAYTIME): 772-370-9770 FAX:
OWNER/BUILDER INFORMATION:
NAME: ROSALINDA M.SCHWAB
ADDRESS:425 BARTOW ST
CITY: FORT PIERCE STATE: FLORIDA ZIP: 34982
PHONE(DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
RECEIVED
SLCCC.- 9123109 JUN 14 '2021
Revised 06130/17
Permitting Department
St.Lucie county
• Vic '
WS Hooc, l taa In I Use,Registration I Hatr ple,I Subent Serdon Ie I stnm a Falb,I pubAcepons i Centect U.i acts Sit,Map UnIs I Beard,i
dbpr ?'�•: ro duct Approval
��USER:puMc
Proeud Approval Henu>Pmdud m AMllratbn Search>Aooilatlon Usti Application attain
FL# FL18686-R4
•/ ,,-. Application Type Revision
Code Version 2020
Application Status Approved
•Appmved by OBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary.
Comments
Archived CI
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,N1 07054
(800)766-3411
mstleh@gaf.com
Authorized Signature Michael Stleh REVIEWED FOR
mstleh@gaf.com
Technical Representative Michael Stleh
CODE COMPLIANCE
Address/Phone/Email 1 Campus Drive ■may, Q/��
(Parsippany,NJ
973)628-30007054 ST. LUCIE COUNTY
mstleh@gaf.com COUNTY
Quality Assurance Representative ®C
Address/Phone/Email
Category Roofing
Subcategory Underlaymems / l
Compliance Method Evaluation Report from a Product Evaluation Entity IVU
Evaluation Entity Miami-Dade BCC0-EVL
Quality Assurance Entity MlaIn-Dade BCCO-QUA ®�
Quality Assurance Contract Expiration Date 02/22/2023. 111YYY C,/
Validated By Miami-Dade BCCO-VAL
Certificate of Independence
Referenced Standard and Year(of Standard) Standard Year
ASTM D226 ,a.y,;•;,,G:
`� ►� J �Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option C
Date Submitted 11/03/2020
Date Validated 11/20/2020 %jN
Date Pending FBC Approval EV I I
Date Approved 11/24/2020
Surnmarif of Products
FL# Model,Number or Name Description
18686.1 FeltBuster High Tfxctlon Synthetic Roofing Felt
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL38686 R4 ii NOA 19-0917.02 GAF FeltBus[erodf
Approved for use outside HVHZ:Yes' Verified By:Miami-Dade BCCO-EVL
Impact Resistant:No Created by independent Third Party:
Design Pressure:N/A Evaluation Reports
Other: FL18686 R4 AE NOA 19-0917.02 GAF FeICBusteoodf
a nck N rt
$.oyi(,q,11g::7601 gal,51nne Road.nogli,se-EL 31399 Phone:a50-4a)-taN
The state oI nodes ts an A o employer.gomdant 20a)-2013 State M Florida::Pdvecv Statement n Ateesslairity Statement::Relund Statement
Under Florida law,maid addressts are public mcInu.If you do not want Your—all addreae released In response we public-records request,do not send elemonlc mall to Nis entity.Instead,cootset the office by phone or by Uadidonal mall,if you have any questions,please contact 650.487.1395.
•Pursuant to Sectlon 455.215(1),Flodda statutes,eaective on giber 1,sots,licences licensed under Chaptey45S,F.S.must provide the DePsol—It vAth an emall eddm,If they have one.The emails provided may be used for Wool eommunlcatlon v,V,—Joe..Howxyer email aed—are
public fecoN.If you do not wish to supply a personal address,please provide the Department wtth an email address—cl,can be mode evadable to it,publl,.To date -if you area a¢nzee under Oupmr 455,F.S.please clerk here.
Product Approval—pia:
®®W.®M
Credit Card
,.:;::Safe'..'•":
File COPY
MIAMI-DADS
e MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
GAF
1 Campus Drive
Parsipanny,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Leak Barriers and Roof Deck Protection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 18-1023.10 and consists of pages 1 through 8.
The submitted documentation was reviewed by Jorge L.Acebo.
NOA No.: 19-0917.02
MIAMMADECOUNTY Expiration Date: 02/22/23
"'• • Approval Date: 10/15/20
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayinent
Material: SBS/Polypropylene/Asphalt
SCOPE:
This approves GAF Leak Barriers and Roof Deck Protection underlayments,to be used on existing roof assemblies as
described in this Notice of Acceptance, designed to comply with the Florida Building Code and the High Velocity
Hurricane Zone of the Florida Building Code.
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
WeatherWatch® 36"x 50' rolls ASTM D1970 Granular surfaced modified,fiberglass reinforced,
Mineral Surfaced Leak 36"x 66.7'rolls bituminous sheet material for use as a leak barrier
Barrier underlayment in sloped roof assemblies. Designed
Manufacturing as an ice&rain shield.
Location#1,8, 14, 15
StormGuard®Film 36"x 66.7' rolls ASTM D1970 Modified,fiberglass reinforced,bituminous sheet
Surfaced Leak Barrier material for use as a high temperature leak barrier
Manufacturing underlayment in sloped roof assemblies. Designed
Location#1,8 as an ice&rain shield.
Liberty'SBS Self- 393/8"x 66'rolls ASTM D1970 Self-adhering SBS roof membrane.
Adhering Base/Ply ASTM D4601
Sheet Type II
Manufacturing
Location#1,8
Deck-ArmorTm Premium 54"x 222'rolls ASTM D226 A UV-stabilized polypropylene breathable
Breathable Roof Deck 48"x 250'rolls Type Il underlayment. To be used for roof deck protection
Protection 48"x 100'rolls as an underlayment in sloped roof assemblies.
Manufacturing
Location#7
Tiger Pawl Premium 48"x 250' rolls. ASTM D226 A UV-stabilized polypropylene non-breathable
Roof Deck Protection 48"x 100'rolls Type ll underlayment. To be used for roof deck protection
Manufacturing as an underlayment in sloped roof assemblies.
Location#2,4,5,7, 10,
11, 12
FeltBuster®High- 48"x 250'rolls ASTM D226 A UV-stabilized polypropylene non-breathable
Traction Synthetic Type ll underlayment.To be used for roof deck protection
Roofing Felt as an underlayment in sloped roof assemblies.
Manufacturing
Location#6,7,13
NOA No.: 19-0917.02
MIAMI•DADE COUNTY Expiration Date: 02/22/23
'"'• ' Approval Date: 10/15/20
Page 2 of 8'
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Shingle-Mate®Roof 36"x 144' rolls ASTM D226 Fibergass-reinforced asphalt felt underlayment.To
Deck Protection Type II be used for roof deck protection as an
Manufacturing underlayment in sloped roof assemblies.
Location#3,16
Liberal"SA Glass Cap 39 3/8"x 34'rolls ASTM D1970 Granular surfaced modified, fiberglass reinforced,
Sheet ASTM D6163 self-adhering SBS roof membrane.
Manufacturing ASTM D7530
Location#8
GAFGLAS®Ply 4 39.37" ASTM D2178 Asphalt impregnated glass felt with asphalt
Manufacturing (1 meter)Wide Type IV coating.
Location#8,9
GAFGLAS®F1exPly"'6 39.37" ASTM D2178 Asphalt impregnated glass felt with asphalt
Manufacturing (1 meter)Wide Type VI coating.
Location#8,9
Tri-Ply®Ply 4 39.37" ASTM D2178 Asphalt impregnated glass felt with asphalt
Manufacturing (1 meter)Wide Type IV coating.
Location#8,9
MANUFACTURING LOCATION:
1.Mt.Vernon,IN
2.Mission,British Columbia
3.Pryor,OK
4. Qingdao, China
5.Charleston, SC
6. Spartanburg, SC
7.Dadra,India
8. Savannah, GA
9.Fontana, CA
10.Homer,LA
11.Umerkui Kilvani,India
12.Parzai,India
13.Richmond,VA
14.Arkadelphia,AR
15.Tuscaloosa,AL
16. Shafter,CA
NOA No.: 19-0917.02
MIAMI-DADECOUNTY Expiration Date: 02/22/23
"• Approval Date: 10/15/20
Page 3 of 8
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Reyort Date
Intertek Testing Services NA Ltd. 3077464-01 ASTM D1970 08/23/06
3090131 Wind Uplift and Self Sealability 08/23/06
100258583COQ-OIOA ASTM D226 Type II 01/11/11
100673818COQ-003 ASTM D226 Type II 06/13/13
10157289000Q-005 ASTM D226 Type Il 04/17/14
F8549.02-106-18-RO ASTM D226 Type Il 11/08/16
PRI Construction Materials RGM-023-02-01 ASTM D4798 05/16/07
Technologies,LLC. GAF-112-02-01 ASTM D226 Type II 03/15/06
GAF-238-02-01 ASTM D1970 03/03/10
GAF-323-02-01 ASTM D1970 11/30/11
GAF-324-02-01 ASTM D1970 11/30/11
GAF-325-02-01 ASTM D1970 11/30/11
GAF-326-02-01 ASTM D1970 11/30/11
GAF-275-02-01 ASTM D1970 11/11/10
GAF-344-02-01 ASTM D1970 04/23/12
GAF-339-02-01 ASTM D226 Type l 03/14/12
ELK-311-02-01 ASTM D1970 09/11/07
GAF-446-02-01 ASTM D226 Type I 09/26/13
GAF-518-02-01 ASTM D226 Type II 06/04/14
GAF-818-02-01 ASTM D4533 12/06/17
GAF-829-02-01 ASTM D226 Type II 01/15/18
GAF-314-02-01 ASTM D2178 07/21/11
GAF-315-02-01 ASTM D2178 07/21/11
GAF-826-02-01 ASTM D226 Type IVASTM D4533 07/12/18
GAF-847-02-01 ASTM D226 Type II/ASTM D4533 06/05/18
GAF-914-02-01 ASTM D226 Type IVASTM D4533 04/11/19
376TOO12 ASTM D226 Type II 07/16/19
376TOO18 ASTM D226 Type II 08/01/19
376T0032 ASTM D1970 10/22/19
376TOO54 ASTM D226 02/19/20
Trinity-ERD GAF-SC13285.17-1 ASTM D1970 03/08/17
GAF-SC13285.17-3 ASTM D1970 03/08/17
GAF-SC13285.17-4 ASTM D1970 03/08/17
GAF-SC13285.17-2 ASTM D4601 Type I1 03/08/17
GAF-SC9700.08.15-R1 ASTM D2178 02/08/17
GAF-SC12915.09.17 ASTM D1970 12/11/17
GAF-SC12915.09.17 ASTM D6163 12/11/17
GAF-SC12915.09.17 ASTM D7530 12/11/17
NEMO ETC,LLC 4S-GAF-18-001.01.19-1 ASTM D2178 Type IV 01/02/19
4S-GAF-18-001.01.19-1 ASTM D2178 Type VI 01/02/19
NOA No.: 19-0917.02
MIAMI-DADS COUNTY Expiration Date: 02/22/23
"'• • Approval Date: 10/15/20
Page 4 of 8
APPROVED ASSEMBLIES:
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck,membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies
of ASTM D 226 Type II,Deck-Armor'Premium Breathable Roof Deck Protection,FeltBuster®
High-Traction Synthetic Roofing Felt,or Tiger PawTM Premium Roof Deck Protection with a
minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and staggered rows 12" o.c. in a grid pattern in the field of the roll.
If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's
installation instructions).Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier, StormGuare Film
Surfaced Leak Barrier,LibertyT'SA Glass Cap Sheet, or LibertyT'"SBS Self-Adhering Base/Ply
Sheet membrane with a minimum 3"side lap and 6"end lap. Place the first course of membrane
parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release
membrane as the membrane is applied. Vertical strapping of the roof with WeatherWatch®
Mineral Surfaced Leak Barrier,or StormGuardv Film Surfaced Leak Barrier is acceptable.
Surfacing: Approved Roofing Assembly.
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Membrane mechanically fastened to deck.
Separator Sheet: One or more plies of GAF GAFGLAS®Ply 4, GAFGLAS®FlexPlyT`"6,Rosin Paper,ASTM D
226 Type I or Type II, Shingle-Mate®Roof Deck Protection,Deck-Armor M Premium Breathable
Roof Deck Protection,FeltBuster®Hi h=Traction Synthetic Roofing Felt,or Tiger Paw"'
Premium Roof Deck Protection loose laid.
Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier, StormGuardo Film
Surfaced Leak Barrier,Liberty'm SA Glass Cap Sheet, or LibertyT SBS Self-Adhering Base/Ply
Sheet membrane mechanically fastened with a minimum 3"side lap and a 6"end lap to deck
through the separator sheet with approved nails and tin caps 6" o.c. at the laps and staggered rows
12" o.c. in a grid pattern in the field of the roll.
Surfacing: Approved Roofing Assembly.
NOA No.: 19-0917.02
MIAMI•DADE COUNTY Expiration Date: 02/22/23
'"'• � Approval Date: 10/15/20
Page 5 of 8
i
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck,membrane adhered..
Secondary Water Install a minimum 4"wide WeatherWatch®Mineral Surfaced Leak Barrier,Liberty"d SBS Self-
Barrier: Adhering Base/Ply Sheet,Liberty'-`"SA Glass Cap Sheet,or StormGuardo Film Surfaced Leak
(Optional) Barrier membrane over the joints of the plywood roof deck prior to installation of the base sheet.
Do not overlap end or side joints.All side and end laps should be butted firmly side by side,flush
with each other but not overlapped.Do not leave the WeatherWatch®Mineral Surfaced Leak
Barrier,or StormGuare Film Surfaced Leak Barrier membrane exposed for more than 30 days
without a roof deck protection underlayment protecting the secondary water barrier.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies
of ASTM D 226 Type II,Deck-Armor''Premium Breathable Roof Deck Protection,FeltBuster®
High-Traction Synthetic Roofing Felt,or Tiger Paw"`'Premium Roof Deck Protection with a
minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and staggered rows 12"o.c.in a grid pattern in the field of the roll.
If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape(follow the tape manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fasteners.
Surfacing: Approved Roofing Assembly.
Deck Type 1: Wood,non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck,membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies
of ASTM D 226 Type II,Deck-Armor''-'Premium Breathable Roof Deck Protection,FeltBuster®
High-Traction Synthetic Roofing Felt, or Tiger Paw"Premium Roof Deck Protection with a
minimum 4"side lap and a 6" end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and staggered rows 12" o.c.in a grid pattern in the field of the roll.
If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's
installation instructions).Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of StormGuare Film Surfaced Leak Barrier membrane with a minimum 4"
side lap and 6" end lap. Place the first course of membrane parallel to the eave,rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied.
Surfacing: Approved f6r Metal roofing, Slate,and Asphalt Shingle assemblies.
NOA No.: 19-0917.02
QMIAMI-DADE COUNTY Expiration Date: 02/22/23
"'• Approval Date: 10/15/20
Page 6 of 8
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. WeatherWatch®Mineral Surfaced Leak Barrier, StormGuardo Film Surfaced Leak Barrier,LibertyT" SBS Self-
Adhering Base/Ply Sheet,LibertyT"SA Glass Cap Sheet, Shingle-Mate®Roof Deck Protection,Deck-Armor
Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt,and Tiger Paw"'
Premium Roof Deck Protection shall not be used as roof tile underlayment.
3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.WeatherWatch®Mineral Surfaced Leak Barrier, StormGuardo Film Surfaced Leak
Barrier,LibertyT"SBS Self-Adhering Base/Ply Sheet,LibertyT'SA Glass Cap Sheet, Shingle-Mate®Roof Deck
Protection,Deck-Armor""Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic
Roofing Felt,and Tiger PawT"Premium Roof Deck Protection shall be installed in strict compliance with applicable
Building Code.
4. WeatherWatch®Mineral Surfaced Leak Barrier, StormGuardo Film Surfaced Leak Barrier,LibertyT"SBS Self-
Adhering Base/Ply Sheet,LibertyT'SA Glass Cap Sheet, Shingle-Mate®Roof Deck Protection,Deck-Armor"
Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt,and Tiger PawT'
Premium Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of
irregularities.
5. WeatherWatch®Mineral Surfaced Leak-Barrier, StormGuardo Film Surfaced Leak Barrier,LibertyT" SBS Self-
Adhering Base/Ply Sheet,LibertyT'SA Glass Cap Sheet, Shingle-Mateo Roof Deck Protection,Deck-Armor"'
Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt, and Tiger PawT"
Premium Roof Deck Protection membranes shall not be applied over an existing roof membrane.
6. WeatherWatch®Mineral Surfaced Leak Barrier, StormGuardo Film Surfaced Leak Barrier,LibertyT"SBS Self-
Adhering Base/Ply Sheet,LibertyT"SA Glass Cap Sheet, Shingle-Mate®Roof Deck Protection,Deck-Armor""
Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt, and Tiger PawT`
Premium Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application.
7. WeatherWatch®Mineral Surfaced Leak Barrier, StormGuardo Film Surfaced Leak Barrier,LibertyT"SBS Self-
Adhering Base/Ply Sheet,LibertyT" SA Glass Cap Sheet, Shingle-Mate®Roof Deck Protection,Deck-Armor'
Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt,and Tiger Paw""
Premium Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing
WeatherWatch®Mineral Surfaced Leak Barrier, StormGuardo Film Surfaced Leak Barrier,LibertyT'SBS Self-
Adhering Base/Ply Sheet,LibertyT"SA Glass Cap Sheet, Shingle-Mate®Roof Deck Protection,Deck-Armor"'
Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt,and Tiger Paw"'
Premium Roof Deck Protection as a component part of an assembly in the Notice of Acceptance. If
WeatherWatch®Mineral Surfaced Leak Barrier, StormGuardo Film Surfaced Leak Barrier,LibertyT'SBS Self-
Adhering Base/Ply Sheet,LibertyT" SA Glass Cap Sheet, Shingle-Mate®Roof Deck Protection,Deck-Armor""
Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt and Tiger Paw"
Premium Roof Deck Protection are not listed; a request may be made to the Authority Having Jurisdiction(AHJ)or
the Miami-Dade County Product Control Department for approval provided that appropriate documentation is
provided to detail compatibility of the products,wind uplift resistance,and fire testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45'F and
rising.
9. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane
from the center outward in both directions.
10. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to
overlap areas.
NOA No.: 19-0917.02
MIAMbDADECOUN7Y Expiration Date: 02/22/23
Approval Date: 10/15/20
Page 7 of 8
LIMITATIONS:
11. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city
and state of manufacturing facility,and the following statement: "Miami-Dade County Product Control Approved"
or the Miami-Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 19-0917.02
CMIAMMADECOUNTY Expiration Date: 02/22/23
Approval Date: 10/15/20