Loading...
HomeMy WebLinkAboutAPPROVED Sentinel 120 Alum. Horizontal Sliding Window -LMI 20-0610.03 (2)MIAMI-DARE MIAMI—DADE COUNTY, FLORIDA PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.2ov/economy CGI WINDOWS and DOORS, INC. 3780 W. 104" Street Hialeah, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "HR120-Sentinel' Aluminum Horizontal Sliding Window - L.M.I. APPROVAL DOCUMENT: Drawing No. HR 120LM-NOA Rev A (former W10-18), titled "Series 120 Alum. Horizontal Sliding Window-LM", sheets 1 through 14 of 14, dated 06/03/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P. E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No. 17-0918.09 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq L Chanda, P. E. / / NOA No. 20-0610.03 L � ,I,] Expiration Date: September 22, 2025 Approval Date: September 10, 2020 Page 1 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA's No.'s 10-0510.12 and 15-0512.05) 2. Drawing No. W10-18, titled "Series Sentinel 120 Alum Horiz. Sliding Wdw. (L.M.I./ S.M.I.)", sheets 1, 1. 1, 2, 2.1, 3, 3.1, 4 through 11 of 11, dated 03/29/10 with revision "G" dated 05/02/16, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 201-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test, per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 6) Forced Entry Test, FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a series Sentinel 120 aluminum horizontal sliding window, prepared by Certified Test Laboratories, Test Report No. CTLA- 3062W, dated 07/07/15, signed and sealed by Ramesh C. Patel, P.E. 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test, per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under previous NOA No. 15-0512.05) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test, per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series project out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal(V and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under previous NOA No. 15-0512.05). 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test, per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series aluminum fixed window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA- 3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under previous NOA No. 15-0512.05) Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-1 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 201-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Small Missile Impact Test, per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading, per FBC, TAS 203-94 6) Forced Entry Test, FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a series "Sentinel" aluminum horizontal sliding window, prepared by Hurricane Test Laboratory, LLC, Test Report No. HTL-0080-0102-10, dated 06/04/10, signed and sealed by Vinu J. Abraham, P. E. (Submitted under NOA No. 10-0510.12) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 5` Edition (2014), prepared by Al-Farooq Corporation, dated 09/17/15 revised on 05/11/16, signed and sealed by Javad Ahmad, P. E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. for their "Butacite® PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers", expiring on 07/04/18. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/ 19/ 14, expiring on 12/ 11 / 18. 4. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers", expiring on 05/21/16. F. STATEMENTS 1. Statement letter of conformance, of complying with FBC 5th Edition (2014) and of no financial interest, dated 08/17/15, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P. E. 2. Laboratory compliance letters for Test Report No. CTLA-3062W, dated 07/07/15, issued by Certified Test Laboratories, signed and sealed by Ramesh C. Patel, P. E. 3. Testing Proposal issued by the Product Control Section, dated 04/08/15, signed by Jaime Gascon, P. E., Section Supervisor. 4. Laboratory compliance letters for Test Reports No.'s CTLA-3056 WA, dated 03/03/15, CTLA-3056 WB, dated 03/03/15 and CTLA-3056 WC, dated 04/16/15, all issued by Certified Test Laboratories, all signed and sealed by Ramesh C. Patel, P. E. (Submitted under previous NOA No. 15-0512.05) lshaq 1. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-2 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS (CONTINUED) 5. Testing Proposal issued by the Product Control Section, dated 12/16/14, signed by Jaime Gascon, P. E., Section Supervisor. (Submitted under previous NOA No. 15-0512.05) 6. Laboratory compliance letters for Test Report No. HTL-0080-0102-10, issued by Hurricane Test Laboratory, LLC, dated 06/04/10, signed and sealed by Vinu J. Abraham, P. E. (Submitted under NOA No. 10-0510.12) G. OTHERS 1. Notice of Acceptance No. 15-0512.05, issued to CGI Windows & Doors for their Series "Sentinel 120" Aluminum Horizontal Sliding Window — L.M.I., approved on 08/20/15 and expiring on 09/22/20. 2. EVIDENCE SUBMITTED UNDER PREVIOUS NOA A. DRAWINGS 1. Drawing No. W10-18, titled "Series Sentinel 120 Alum Horiz. Sliding Wdw. (L.M.I./ S.M.I.)", sheets 1, 1. 1, 2, 2.1, 3, 3.1, 4 through 11 of 11, dated 03/29/10 with revision "H" dated 09/05/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Interlayer" dated 06/25/15, expiring on 07/04/18. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/ 17, expiring on 12/ 11 / 18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. 1 s�-7 1. Ll4yn�� lshaq 1. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-3 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance to FBC 5th Edition (2014) and FBC 6th Edition (2017), dated 08/30/17, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P. E. G. OTHERS 1. This NOA revises NOA #15-0929.13, expiring on 09/22/20. 3. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. HR 120LM-NOA Rev A (former W10-18), titled "Series 120 Alum. Horizontal Sliding Window-LM", sheets 1 through 14 of 14, dated 06/03/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P. E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all CGI Windows and Doors, Inc. and PGT Industries, Inc., representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal) FTL-20- 2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal)all dated 08/24/20 and signed and sealed by Idalmis Ortega, P.E. PGT Industries, Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20- 2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 7' Edition (2020), dated 03/26/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM E1300-04, -09, -12 and -16. 1 s�G7 1. L�,InJ,, Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-4 CGI Windows & Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 3. NEW EVIDENCE Continue: D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers", expiring on 07/08/24. 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers", expiring on 07/04/23. 3. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. 4. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core", expiring on 12/11/23. F. STATEMENTS 1. Statement letters of conformance to FBC 2020(7th Edition), dated 03/26/20, prepared, signed & sealed by Lynn Miller, P. E. 2. Statement from Successor Engineer, adopting another Engineer's work as his own per FLA 51G915.27-001, signed and sealed on 06/03/20 by Anthony Lynn Miller, P.E. 3. Statement of Lab compliance as part of the test report. G. OTHER 1. This NOA revises and renews NOA No. 17-0918.09 and updates to FBC 2020 (7th Edition) expiring 09/22/25. 2. RER Test proposals #19-1155 dated 01/10/20 approved by Ishaq I. Chanda, P.E. 1 s�-7 I. L4hhjs Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0610.03 Expiration Date: September 22, 2025 Approval Date: September 10, 2020 E-5 111" FLANGE WIDTH I o to 6" MAX. MTG. STI E (I F (I F a O 1 II � II a 19 I) a II wr_-» - -.0 FALSE MUNTINS 32 7 8" ADDL. ANCHOR READ. (SURFACE APPLIED) D.L.OPG. 32 7/8» AT CENTER OF ALL PANELS OPTIONAL D.L. OPG. FIXED OR OPERABLE 36 3 8" ABOVE 30" PANEL WIDTHS VENT WIDTH AT HEAD/SILL. FLANGE & FLANGE ADAPTOR FRAME vtry I MUM n FIN FRAME 5 1/2" MAX. _O N O 4 s W — = M N = to �[ 00 Lo Lo w `o > > m MTG. STILES E1 10 c3 II F 9 47 II F II 9 a O II � II 19 kIB II II m FALSE MUNTINS ADDL ANCHOR READ. (SURFACE APPLIED) 32 7/8" 32 7/8" AT CENTER OF ALL PANELS OPTIONAL D.L. OPG. D.L. OPG. FIXED OR OPERABLE 8" ABOVE 30" PANEL WIDTHS 36 3 / AT HEAD/SILL. VENT WIDTH EQUAL LEG FRAME LAMINATED GLASS THESE WINDOWS ARE RATED FOR LARGE INSULATING LAM. GLASS & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. LARGE MISSILE IMPACT SMALL MISSILE IMPACT SERIES `SENTINEL 1200' ALUMINUM HORIZONTAL ROLLER WINDOW DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEETS 3-6. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF H.R./H.R. OR HORIZONTAL ROLLING WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI-DADE COUNTY APPROVED CLIPPED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION)/2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BUILDING CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. REVISED FOR 2020 FBC, ADDED ANCHOR TYPE & ;° REFORMATTED - JR - 5/29/20 o Y �L N_ ^aa rn N O Q w rn o O Z LU —cam. > N a}OQ Z cl Z N �H }cl } 0 J r H uMDJQ Q0�Y _ JJO —' N oZ (D (D �Ma V 0 Q W Z co Z aF'Lu W r- o a C) z `- p U) 'z }aa4S I— J �! z Q W Z V! �C Z W aloos ca 0 Wco OW oN o CD��� W Q z �co CL `�=mo E w z ooLL o p cWi� Z y5 Q J Z O w< 0 ��Qo UcoS� W (� _ al— hsaa sauas .l{°. No.56705 % ( STATE F �LfL1J RI /////"ONAL \ A. LYNN MILLER, P.E. P.E.# 58705 TYPICAL ELEVATION. 1 /4-1 /2-1 A XOX CONFIGURATION 111" w 110" w FLANGE WIDTH � w BUCK WIDTH w 5 1 /2" MAX. N U 5" MAX. TYP. _ MO 0 5" MAX. TYP. HEAD/S MAX. A C MTG. STILES HEAD SILL Al MTG. STILES `0� = x N W , CD = W N W d N= = M tDz loZ tLn o �U 0Z U) Z > m > L� m I'M Qa FALSE MUNTINS FALSE MUNTINSJ 24 1 2" ADDL ANCHOR REQD. 24 1 2" ADDL. ANCHOR READ. (SURFACE APPLIED) 49 5/8" AT CENTER OF ALL PANELS (SURFACE APPLIED) 49 5/8" AT CENTER OF ALL PANELS OPTIONAL D.L. OPG. OPTIONAL D.L. OPG. D.L. OPG. FIXED OR OPERABLE D.L. OPG. FIXED OR OPERABLE 28" ABOVE 30" PANEL WIDTHS 28" ABOVE 30" PANEL WIDTHS VENT WIDTH AT HEAD/SILL. VENT WIDTH AT HEAD/SILL FLANGE & FLANGE ADAPTOR FRAME EQUAL LEG FRAME LAMINATED GLASS 110" M Z THESE WINDOWS ARE RATED FOR LARGE BUCK WIDTH o &SMALL MISSILE IMPACT. SHUTTERS ARE INSULATING LAM. GLASS 5 1/2" MAX. 5" MAX. TYP. 13 15/1s" MAX. NU NOT REQUIRED. LARGE MISSILE IMPACT HEAD SILL MTG. STILES HEAD SILL — M SMALL MISSILE IMPACT — M x e = w Y U to M m > M mJ- FALSE MUNTINS 24 1 2" (SURFACE APPLIED) 49 5/8" OPTIONAL D.L. OPG. D.L. OPG. 28" VENT WIDTH FIN FRAME E I' F II 9 L I I I F � 9 II 9 � I) I) II II B 8 II (I D 8 II 19 E2 II F II II F II U a 0 II I) II 2191 I II II II E1 II F II I F 9 (I II � a 0 II II II (I B1 8 II II II 1g c 0 .N a � Y Q N_ N 0 Q w N o 0 Z W N a}°O Z Z c N f8 } O UMO�a Q 0 M m OJO '°N u~j coo 8MO �WV� H w p Z d` `- a. w�>: 0 0 —o Z (� Z � N }aa4S H � U7 �C O Z Q z y uj z W 3 pe Q W Of V M a CL co Z Z G Lo W O J - C)MQo Q o w W N CN Ur�2c .N-- W _ a�}}l �asa0 sauas No. 55705 1 (� °. STA E OF �: 'o °'•'4ORIG�,•'' ft°t}ItlloW A. LYNN"MILLER, P.E. P.E.# 58705 DESIGN LOAD CAPACITY - PSF (XO OR OX SIZES) FLANGE DIMS. BUCK DIMS. STD. MTG. RAIL H.D. MTG. RAIL GLASS TYPES 'A'&'Al', 'B'&'Bi' GLASS TYPES 'B' & 'Bl' WIDTH HEIGHT WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) 26-1/2" 37" 53-1/8" 74" 26„ 25-1/2" 36" 52-1/8" 73" 25" 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 26-1/2" 37" 53-1/8" 74" 38-3/8" 25-1/2" 36" 52-1/8" 73" 37-3/8" 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 26-1 /2" 37" 53-1/8" 74" 50-5/8" 25-1 /2" 36" 52-1/8" 73" 49-5/8" 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 26-1/2" 37" 53-1/8" 74" 63" 25-1/2" 36" 52-1/8" 73" 62„ 1 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 60.2 60.2 80.0 90.0 OPERATING VENTS TO BE 1/2 OF THE WINDOW WIDTH DESIGN LOAD CAPACITY - PSF (XOX SIZES) FLANGE DIMS. BUCK DIMS. STD. MTG. RAIL H.D. MTG. RAIL H.D. MTG. RAIL GLASS TYPES 'A'&'Al', 'B'&'Bl' GLASS TYPES 'B' & 'Bl' GLASS TYPES 'C' & 'Cl' WIDTH HEIGHT WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) INT.(-) 55-3/4" 78-15/16" 83-1/2" 26" 54-3/4" 77-15/16" 82-1/2" 25" 65.0 65.0 80.0 90.0 65.0 65.0 65.0 65.0 80.0 90.0 65.0 65.0 65.0 65.0 80.0 90.0 65.0 65.0 55-3/4" 78-15/16" 83-1/2" 38-3/8" 54-3/4" 77-15/16" 82-1/2" 37-3/8" 65.0 65.0 80.0 90.0 65.0 65.0 65.0 65.0 80.0 90.0 65.0 65.0 65.0 65.0 1 80.0 90.0 1 65.0 65.0 55-3/4" 78-15/16" 83-1 /2" 50-5/8" 54-3/4" 77-15/16" 82-1 /2" 49-5/8" 65.0 65.0 80.0 90.0 65.0 65.0 - - - - 65.0 65.0 - - - - 65.0 65.0 55-3/4" 78-15/16" 83-1 /2" 63" 1 54-3/4" 77-15/16" 1 82-1 /2" 62" 65.0 65.0 80.0 90.0 65.0 65.0 - - - - 65.0 65.0 - - - - 65.0 65.0 (2/3W) OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH X" TYP. BUCK DIMS Xz" TYP. BUCK DIMS FLANGE FRAME Lp EQUAL LEG FRAME FLANGE DIMS NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 BUCK DIMS FLANGE ADAPTOR FRAME FLANGE DIMS FLANGE FRAME FLANGE ADAPTOR FRAME EQUAL LEG FRAME c Q) rr o Y Q •A&H N Q > O� O N o Z J > � a}op Z o Z N �8 } Ln O } UMDJ(7 �- r Qo"•-i _ CD m0�o 4N (p 0 Z co pMp ¢wzv o.~w Z �- w�LL ��r O a� U ch Z p }aays y U) in C O (j J `) Z d) CC W (n z -1-s �co 0 w NJ E3.CG v p co X m U Z c~n CL U)1:coo O � w Z E3 = d pvuu- 00 W Z ?� Q� J U O O J Q V, aO Q o Ur~i=� O p r r = a�}!1 asap sauas LYN g / If g No.58705 0 °. STATE OF i 40RIOP- �X% � /''/ J; OVAL 0\\\\ A. LYNN MILLER, P.E. P.E.# 58706 DESIGN LOAD CAPACITY - PSF (XOX SIZES) FLANGE DIMS. BUCK DIMS. STD. MTG. RAIL H.D. MTG. RAIL GLASS TYPES 'A'&'Al', 'B'&'Bl' GLASS TYPES 'B' & Ill, WIDTH HEIGHT WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) 74" 106-1 /4" ill" 26" 73" 105-1 /4" 110" 25" 65.0 65.0 1 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 74" 106-1/4" ill" 38-3/8" 73" 105-1/4" 110" 37-3/8" 1 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 1 80.0 90.0 74" 106-1/4" ill" 50-5/8" 73" 105-1/4" 110" 49-5/8" 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 65.0 65.0 80.0 90.0 74" 106-1/4" ill" 63" 73" 105-1/4" 110" 62" 65.0 65.0 80.0 90.0 1 61.6 61.6 80.0 90.0 1 60.0 60.0 80.0 90.0 (1/3W) (1/3W) (1/3W) l OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH 'XOX' DESIGN LOAD CAPACITY - PSF (XOX SIZES) FLANGE DIMS. BUCK DIMS. STD. MTG. RAIL H.D. MTG. RAM H.D. MTG. RAIL GLASS TYPES 'A'&'Al', 'B'&'Bl' GLASS TYPES 'B' & 'Bl' GLASS TYPES 'C' & 'Cl' WIDTH HEIGHT WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) INT.(-) 74" 106-1/4" ill" 26" 73" 105-1/4" 110" 25" 65.0 65.0 1 80.0 90.0 65.0 65.0 65.0 65.0 80.0 90.0 65.0 65.0 65.0 65.0 80.0 90.0 65.0 65.0 74" 106-1/4" ill" 38-3/8" 73" 105-1/4" 110" 37-3/8" 65.0 65.0 80.0 90.0 65.0 1 65.0 65.0 65.0 80.0 90.0 65.0 65.0 65.0 65.0 80.0 90.0 65.0 65.0 74" 106-1/4" ill" 50-5/8" 73" 105-1/4" 110" 49-5/8" 65.0 65.0 80.0 90.0 65.0 65.0 - - - - 65.0 65.0 - - - - 65.0 65.0 74" 106-1/4" ill" 63" 73" 105-1/4" 110" 62" 1 65.0 65.0 80.0 90.0 65.0 65.0 - - - - 65.0 65.0 1 - I - - I - 65.0 65.0 (1/4W) (1/2W) (1/4W) OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH 'XOX' XZ" TYP. BUCK DIMS Y2" TYP. BUCK DIMS FLANGE FRAME EQUAL LEG FRAME FLANGE DIMS NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 BUCK DIMS FLANGE ADAPTOR FRAME FLANGE DIMS FLANGE FRAME FLANGE ADAPTOR FRAME EQUAL LEG FRAME c 0 Y Q pQ W N kCC'y4 0Z> N 4k Z 0 Z �8 >- Lo O UMD-10 N _ Q Q } J o F- DN OZu coo pMp wWU00 � wC)> O a Z Q }aays �.. i _I � � I- 0! z Q N Z y I a�°aS cn c* U W Z W J cc N Z a � o U) � $ 0 'UJ t a W o m Z?�Q� J Q (9 O O J gc- o 0 � LU w � c) 3: 04 a I alp-L rosap Issapas ,11111l1I1(,��lj s j> ``�� • •�1C�E^1S �'� 's No. 58 7 05 w Q STAT GF 1{� A. LYNN MILLER, P.E. P.E.# 58705 DESIGN LOAD CAPACITY - PSF (XO OR OX SIZES) BUCK DIMS. STD. MTG. RAH. H.D. MTG. RAH, GLASS TYPES 'A'&'Al', 'B,&,Bl, GLASS TYPES 'B' & 'Bl' WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) 25-1/2" 36" 52-1/8" 73" 25„ 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 1 65.0 80.0 80.0 25-1/2" 36" 52-1/8" 73" 37-3/8" 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 25-1/2" 36" 52-1/8" 73" 49-5/8" 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 25-1/2" 36" 52-1/8" 73" 62„ 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 60.2 60.2 80.0 80.0 OPERATING VENTS TO BE 1/2 OF THE WINDOW WIDTH 'XO OR OX' DESIGN LOAD CAPACITY - PSF (XOX SIZES) BUCK DIMS. STD. MTG. RAH. H.D. MTG. RAIL H.D. MTG. RAM GLASS TYPES 'A'&'Al', 'B'&'Bl' GLASS TYPES 'B' & '111' GLASS TYPES 'C' & 'Cl' WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) In(-) 54-3/4" 77-15/16" 82-1/2" 25" 65.0 65.0 80.0 80.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 54-3/4" 77-15/16" 82-1/2" 37-3/8" 65.0 65.0 80.0 80.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 54-3/4" 77-15/16" 82-1/2" 49-5/8" 1 65.0 65.0 80.0 80.0 65.0 65.0 - - - - 65.0 65.0 - I - - - 65.0 65.0 54-3/4" 77-15/16" 82-1 /2" 62" 65.0 65.0 80.0 80.0 65.0 65.0 - - - - 65.0 65.0 1 - - - - 65.0 65.0 (2/3W) OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH EMU MO NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 BUCK DIMS FIN FRAME FIN FRAME c 0 N 0 Y <t N N O0 Q O w m o O Z > N a}op Z O }�ul 0 i } 1-F- uMop w < 0 -.4- _ _j `. ON o}OOJC' 0LLI U w 0 a~Lu Z LL WC)> h 0 adz°' O u') Z p }aays y 1 U) in lC o z17- Q co Z LA � 4i uj Z W aloes co caOCco F- Ow 0 Q -i v O R � Of 00 U III Z F-� =C OC O U W I- U=coo 2 o cm o 5 Z >Z Q m oomms=M > OJ�j 5 J ¢ (D U = O C70Qo r0 o N W Q w = 911!1 Isapasl r No, 5870 a G�� ® STAT 02F 4 - A. LYNN MILLER, P.E. P.E.# 58705 DESIGN LOAD CAPACITY - PSF (XOX SIZES) BUCK DIMS. STD. MTG. RAIL H.D. MTG. RAIL GLASS TYPES 'A'&'Al', 'B'&'Bl' GLASS TYPES 'B, & 'Bl' WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) 73" 105-1/4" 110" 25" 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 73" 105-1/4" 110" 37-3/8" 65.0 65.0 80.0 80.0 65.0 1 65.0 80.0 80.0 65.0 65.0 80.0 80.0 73" 105-1/4" 110" 49-5/8" 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 65.0 65.0 80.0 80.0 73" 105-1 /4" 110"1 62" 65.0 65.0 80.0 80.0 61.6 61.6 80.0 80.0 60.0 60.0 80.0 80.0 (1/3W) (1/3W) (1/3W) j it f OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH 'XOX' DESIGN LOAD CAPACITY - PSF (XOX SIZES) BUCK DIMS. STD. MTG. RAM H.D. MTG. RAIL H.D. MTG. RAM GLASS TYPES 'A'&'Al', 'B'&'Bl' GLASS TYPES 'B' & 'Bl' GLASS TYPES 'C' & 'Cl' WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) INT.(-) 73" 105-1/4" 110" 25" 65.0 65.0 80.0 80.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 73" 105-1/4" 110" 37-3/8" 1 65.0 65.0 80.0 1 80.0 65.0 1 65.0 65.0 65.0 80.0 80.0 65.0 65.0 65.0 65.0 80.0 80.0 65.0 65.0 73" 105-1/4" 110" 49-5/8" 65.0 65.0 80.0 80.0 65.0 65.0 - - - - 65.0 65.0 - - - - 65.0 65.0 73" 105-1/4" 110" 62" 65.0 65.0 1 80.0 j 80.0 65.0 65.0 - - - - 65.0 65.0 - - - - 65.0 65.0 (1/4W) (1/2W) (1/4W) OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH 0 NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 BUCK DIMS FIN FRAME FIN FRAME 0 o Y Q o N cn naa N O Q w N O 0 z > N 3 2 a}op Z E JO I)- I-- F w QOM ? _ o 'IN aZu (oo 0 �Ma W 0 c � Op v 1- CL w v Z_ w�>�I 3:o adz°' (D (o z p }aayS y C/) cC O Z Q d Z H 0 (n C4 ca co of Ow Z L &iooS cr. 3o 0W00 o r w z_ u~i CL c)ce) O 2 W I- 'S3 pvuJ cfl a w o Z Q 0 O W J Q (9 w O co Q o C9r`_ � U m S O � W Q � = ai}T'asa4 sauas II . Lyr, 1.1C'I. N84 ' o too. 58705 ( STATE OF °1lt} i 11110\ A. LYNN MILLER, P.E. P.E.# 58705 .075" Saflex CP With PET Core .075" Saflex CP With PET Core By 'Eastman Chemical Co.' By 'Eastman Chemical Co.' V) 090" Saflex Clear And Color Glass in.090" Saflex Clear And Color Glass �- By Eastman Chemical Co. g By 'Eastman Chemical Co.' w090" SentryGlas@ w 090" SentryGlas@ z By 'Kuraray America, Inc.' Z By 'Kuraray America, Inc.' .090" Trosifol PVB 1/8- HEAT — 090" Trosifol PVB 1/8" HEAT 1/8" ANN. GLASS B 'Kuraray Ameica, Inc.' Y Y STREN'D GLASS By Kuraray Ameica, Inc.' STREN'D GLASS 1/8" ANN. GLASS 1/8" HEAT STREN'D GLASS ui k r m SILICONES: m SILICONES: m ? in GE-1200, DOW 791, ? GE-1200, DOW 791, z rn (n Ng M1 899, 983, OR 995 N Ng M1 899, 983, OR 995 V) Nc� M 1/8" ANN. GLASS 1/4" AIR SPACE 1/8" ANN. OR TEMPERED* GLASS AT 1/4 POINTS ON LITES AT 1/4 POINTS ON LITES W M7 WIDER THAN 36" W M7 WIDER THAN 36" W GLASS TYPE 'A' GLASS TYPE 'B' 5/16" NOMINAL LAM. GLASS 5/16" NOMINAL LAM. GLASS (L.M.I & S.M.I.) (L.M.I & S.M.I.) 075" Saflex CP With PET Core 1 /8" HEAT STREN'D GLASS By 'Eastman Chemical Co.' .090" Saflex Clear And Color Glass By 'Eastman Chemical Co.' 090" SentryGlas@ zBy 'Kuraray America, Inc.' 090" Trosifol PVB By 'Kuraray Ameica, Inc.' r1/8" ANN. GLASS 1/4" AIR SPACE 1/8" HEAT STREN'D OR TEMPERED* GLASS .075" Saflex CP With PET Core By 'Eastman Chemical Co.' w.090" Saflex Clear And Color Glass y By 'Eastman Chemical Co.' Q 090" SentryGlas® Lu z By 'Kuraray America, Inc.' .090" Trosifol PVB By 'Kuraray Ameica, Inc.' r-1/8" HEAT STREN'D GLASS .075" Saflex CP With PET Core By 'Eastman Chemical Co.' .090" SentryGlas® By 'Kuraray America, Inc.' 1/8" HEAT STREN'D GLASS SILICONES: GE-1200, DOW 791, 899, 983, OR 995 AT 1/4 POINTS ON LITES WIDER THAN 36" GLASS TYPE V 5/16" NOMINAL LAM. GLASS (L.M.I & S.M.I.) 1/8" HEAT STREN'D 1/4" AIR SPACE 1/8" HEAT STREN'D OR TEMPERED* GLASS m SILICONES: m SILICONES: 2 m ? N GE-1200, DOW 791, ? V) GE-1200, DOW 791, ? to 899, 983, OR 995 g M1 899, 983, OR 995 g XL EDGE SPACER XL EDGE SPACER ST. STEEL BY 'CARDINAL' ST. STEEL BY 'CARDINAL' OR OR P+ DURASEAL BY 'QUANEX' a DURASEAL BY 'QUANEX' a 0 OR 0 OR 0 E9 SUPER SPACER BY 'QUANEX' W Eg SUPER SPACER BY 'QUANEX'W; W M7 AT 1/4 POINTS ALL SIZES W M7 AT 1/4 POINTS ALL SIZES W GLASS TYPE 'Al' GLASS TYPE 11' 0.70" OVERALL INSUL. LAM. GLASS 0.70" OVERALL INSUL. LAM. GLASS (L.M.I & S.M.I.) (L.M.I & S.M.I.) * FOR INSULATED GLASS INSTALLATIONS ABOVE 30' IN THE HVHZ, OR FOR SAFETY GLAZING APPLICATIONS PER THE FBC, THE OUTBOARD LITE (CAP) MUST BE TEMPERED. w .075" Saflex CP With PET Core } By 'Eastman Chemical Co.' WC .090" SentryGlas® !z— By 'Kuraray America, Inc.' 1/8" HEAT STREN'D GLASS SILICONES: GE-1200, DOW 791, 899, 983, OR 995 XL EDGE SPACER ST. STEEL BY 'CARDINAL' OR DURASEAL BY 'QUANEX' OR SUPER SPACER BY 'QUANEX' AT 1/4 POINTS ALL SIZES GLASS TYPE TV 0.70" OVERALL INSUL. LAM. GLASS (L.M.I & S.M.I.) ADDED BACKBEDDING 0 TYPES - JR - 5/29/20 o Y Qcc o cn nQ rn N O0 W rn a O Z J N > N a}op �k Z Z O f Ice } O_ J i umwc Q 0 C = iJ Jp H 'ON Q w 2 CO Q� .w� w�> LL O 0- za' 0 Z_ p }aayS C 1 z Q Z N rA Z aroaS t oC co w OIV —! ca1b Z M~ Q. (>n=MO 0 w Z E� >hJM = w Ovu- (q z�xM 0 (n Zy�t¢°; � oJ� < Z N g - o r ��Qo O �. a�}rl •asap sauas ��tl1iltlljr}f/ LY NN ° v � . No.58705' 0 a 1 SAT OF ((�: ��� F<ORIOP" • N�� °��rrrlil1111�� A. LYNN MILLER, P.E. P.E.# 58705 FLANGE & FLANGE ADAPTOR FRAME TYPICAL ANCHORS O 6 a 0 I 04 O I4 Ei W A FOR SPACING I METAL STRUCTURE TYPICAL ANCHORS SEE ELEV. FOR SPACING c� w 11-Ulullirm- 1=1 II �� TYPICAL ANCHORS SEE ELEV. FOR SPACING EDGE DIST. INTALLATION DETAILS SHOWN ON PAGES PEEPHOLES: 8 & 9 APPLY TO BOTH FLANGE FRAME W1 = 1/4" X 1-1/2" WEEP SLOT AT 4-1/8" FROM EACH END WITH PLASTIC COVER. AND FLANGE ADAPTOR FRAMES. W2 = 1/8" X 1 /2-WEEP SLOT AT 3-1 /8"FROM EACH END. W3 = 1/8" X 1 /2" WEEP SLOT AT 3-1 /8" FROM EACH END. TYPICAL ANCHORS SEE ELEV. FOR SPACING IAMI—DADE COUNTY APPROVED �M MULLION & MULLION ANCHORS SEE II SEPARATE NOA EDGEI( L - - JI TYPICAL ANCHORS SEE ELEV. FOR SPACING WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: SEE ELEV. FOR SPACING 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) TYP. EDGE DISTANCE INTO WOOD STRUCTURE = 1" MIN. THRU 1 BY BUCKS INTO CONC. OR CMU OR DIRECTLY INTO CONC. OR CMU 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN, EMBED INTO CMU (JAMBS) TYP. EDGE DISTANCE INTO CONCRETE AND CMU = 2-1/2" MIN. 1/4" DIA. ULTRACON+ BY 'DEWALT' (Fu=164 KSI, Fy=148 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-3/8" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) 1" MIN. EDGE DISTANCE THRU 1 BY BUCKS INTO CONC. OR DIRECTLY INTO CONC. 1" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-3/4" MIN. EDGE DISTANCE THRU 1 BY BUCKS INTO HOLLOW CMU OR DIRECTLY INTO HOLLOW CMU 1-1 /4" MIN. EMBED INTO CMU (JAMBS) 1-1 /2" MIN. EDGE DISTANCE #14 SMS OR SELF DRILLING SCREWS._ (GRADE 2 CRS) INTO MIAMI—DADE COUNTY APPROVED MULLIONS (MIN. THK.=1/8") OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM : 1/8" THK. MIN. (6063—T5 MIN.) STEEL : 1/8" THK. MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS Vc = 3000 PSI MIN. C-90 HOLLOW/FILLED NORMAL WEIGHT BLOCK AT JAMBS f'm = 2000 PSI MIN. ADDED ANCHOR TYPE & REFORMATTED -JR- N 5/29/20 cr 0 Y Q N ^aa a) N 0 Q W cop O Z J N Lij N Z 0 z N fg } ,n O_ J}r UMDJp Q0v LL _ J J o N 0Zu (oo (5 pM0 < ry v � Q Nr d~W ww1- > v O IL C7 J 00 Z Q aa45 U) I— CA U) w z z y uj Z g w 3IS °ow ��°6 O Z C L C 2 C n=- 0 m 11-- U) Z E3 z w 0 tLL'o w Z�=� = o 0 Q Z N 5�¢o � Uc)2 04 LL _ a!}!1 •asap sauas ,�ii,(r?rrrrrr No. 53705 0 Q `. STATE OF ONA �//111111{11�� A. LYNN MILLER, P.E. P.E.# 58705 FLANGE & FLANGE ADAPTOR FRAME 1 4" MAX. SHIMS 1/4" MAX. BUCK WIDTH SHIMS INTALLATION DETAILS SHOWN ON PAGES 8 VENT WIDTH VENT WIDTH AND 9 APPLY TO BOTH FLANGE FRAME AND TYPICAL ANCHORS FLANGE ADAPTOR FRAMES. SEE ELEV. FOR SPACING O O O •. 1 1/2- c v NOW c� � wo FLANGE ADAPTOR FRAME o. cn SCREENS OPTIONAL 72BYOOD OR1/2" TYP. wUCTURE o c� w EXTERIOR TYPICAL ANCHORS .2 WOOD BUCKS D.L. OPG. SEE ELEV. XOX LAYOUT FOR SPACING A O N Y Q MIAMI-DADE COUNTY APPROVED MULLION o N (A naa & MULLION ANCHORS SEE SEPARATE NOA N O Q BUCK WIDTH O ALTERNATE o 0 Z BUCK WIDTH n > N a}op SWEEP LOCK z z o �g E21 OPTIONAL TO SPRING LOCK P O } ^ uMo�Q 2 ¢CM S6 o CZ_� ON HMO _ N W � W 00 0 Wow O v ao2 ° O J m J O Z � I=r_.._.. COD J W U) TYPICAL ANCHORS EXTERIOR E3 ccp cj z Q Z Z SEE ELEV. FOR SPACING E4 y m Uj Z g alDoS CO2 *a w O 0 W Ow Z Q J J 1 4" MAX. / BUCK WIDTH 1 4" MAX. / ,r 3 � o o o 0 Q Z SHIM 1 SHIMS c. � u~i coO 1= z VENT WIDTH E ?� o LL� z TYPICAL ANCHORS 1 O 1 O O TYPICAL ANCHORS Do M z_ Q, a o J ui J Q W O Z zSEE fn ELEV. SEE ELEV. 35 o Q o v M= V 0 04 � FOR PACING 1 FOR SPACING L 2 /4„ ll ��,alltttlttt -MY PEI METAL STRUCTURE t o cn 4' v a° No. 58705 SCREENS OPTIONAL %+ EXTERIOR E6 E5 1 1 BY W OD BUCKS ' d T.2 'd:e '. STATE {�F ��~ XO LAYOUT D.L. OPG. a v' fA'i 'O NAL i 111t1t`st1 A. LYNN MILLER, P.E. P.E.# 58705 EQUAL LEG FRAME TYPCCAI ANCHORS n EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY INTO WOOD, CONCRETE OR METAL STRUCTURES WITHOUT THE NEED OF A WOOD BUCK. METAL TYPICAL ANCHORS o STRUCTURE SEE ELEV. OI=— FMIAMI-DADE COUNTY APPROVED FOR SPACING 3 t3 MULLION & MULLION ANCHORS a DGE = II SEE SEPARATE NOA II EDGE DIST. O r T. `d in EDGE \ DIST. L J TYPICAL ANCHORS SEE ELEV. FOR SPACING 1 /4" MAX. \ SHIMS c m u BUCK WIDTH EXTERIOR TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING 2 3/8" MIN. 2-3/8" MIN. WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%". THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. BUCK WIDTH MIAMI-DADE COUNTY APPROVED MULLION & MULLION ANCHORS SEE SEPARATE NOA e = d• U) El.t A 4A A' Q A. d A ,■9 A J e a z • TYPICAL ANCHORS SEE ELEV. a a I FOR SPACING TTYPICAL ANCHO EEELEV.FOR SPACING c 0 �N .j N cc o Y Q o N cA gab a' N O Q w O 0 Z N w N a}op Z 7H Z } to O UMDjp N J}F_ I— QOv 2 2 i J M 0 J O ~ .J �N co r Q w Z v Z wow rl- > u- O 0 o Z_ Q p }aa4S c* Z lC O Z Q _O f- Z W cn Z J a°'c ° w N 3 i0 w C,.c'c� E -°Cl � w w 0 r U- co J in Z = cn �2 j = J J Q O -Q �ui Q Z � U 0 N a _ allu 757(J sagas y F . No. 58705 �1�, �� ® Ad AL.a A. LYNN MILLER, P.E. P.E.# 58705 ILLUSTRATIVE DTLS. ONLY EXT. OR INT. FINISHES NOT BY CGI _ HOUSE WF NOT BY C a c F HOUSE WF NOT BY C, TYPICAL ANCHORS "1 r. —1 FOR SPACING TYPICAL ANCHORS: SEE ELEV. FOR SPACING 8 S S (Fu = 74 KSI MIN.) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1 /2" MIN. PENETRATION INTO WOOD EXTERIOR c 0 ar cr C14o Y Q N_ •Aab 01) N > O Q J rn p O Z J m N � c� G 2}DQ � Z J �8 Z } to O UMDJQ N JI— QOM _ } o H ON OZu-coo D 2� oMQ r U V o 0 ¢WZ ~ z a w r �o>v _ J LL O z�- 1 4S � y in Z O cc 0 R Z Z w C U) Z g aIDOS w °G 3� o w N J 1— R� �o Q- cn=Mo 02 z Z Z ooLLto Q U) 2 - 0� = N 0o ^ Q o o zILL Z � Cq u _ a�}il •�saQ sauas ,E��ltl;ytj ?��irri No. 58705 sT,ATF OF A. LYNN MILLER, P.E. P.E.# 58705 ITEM PART # QUANTITY DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS E1 CGI-100 - FRAME JAMB ® FIXED GLASS 6063-T6 CGI EXTRUDER E2 CGI-113 - FRAME SILL 6063-T6 CGI EXTRUDER E3 CGI-102 - FRAME HEAD 6063-T6 CGI EXTRUDER E4 CGI-103 - MEETING RAIL 6063-T6 CGI EXTRUDER E5 CGI-104 - LOCK RAIL 6063-T6 CGI EXTRUDER E6 CGI-105 - HANDLE RAIL 6063-T6 CGI EXTRUDER E7 CGI-106 - SASH RAIL 6063-T6 CGI EXTRUDER E8 CGI-107 - 5/16" GLAZING BEAD 6063-T5 CGI EXTRUDER E9 CGI-108 - 0.700" GLAZING BEAD 6063-T5 CGI EXTRUDER E10 CGI-109 - FRONT FLANGE ADAPTOR 6063-T6 CGI EXTRUDER E11 CGI-110 - NAIL FIN ADAPTOR 6063-T6 CGI EXTRUDER E12 CGI-135 - TF FRAME JAMB ® FIXED GLASS 6063-T6 CGI EXTRUDER E13 CGI-136 - TF FRAME HEAD 6063-T6 CGI EXTRUDER E14 CGI-139 - TF FRAME JAMB 6063-T6 CGI EXTRUDER E15 CGI-140 - 1" MUNTIN 6063-T5 CGI EXTRUDER E16 CGI-141 - 2.5" MULLION 6063-T6 CGI EXTRUDER E17 CGI-605 - SCREEN FRAME 6063-T5 CGI EXTRUDER E18 CGI-114 - SILL SNAP IN 6063-T6 CGI EXTRUDER E19 CGI-115 - SILL FILLER 6063-T6 CGI EXTRUDER E20 CGI-116 - FRAME JAMB 6063-T6 CGI EXTRUDER E21 CGI-117 - HD LOCK RAIL 6063-T6 CGI EXTRUDER E22 CGI-138 - TF FRAME SILL 6063-T6 CGI EXTRUDER E23 CGI-109 - FRONT FLANGE ADAPTOR 6063-T6 CGI EXTRUDER M1 CGI-382V - GLAZING BULB VINYL (DUROMETER 75-80 SHORE A) PVC - M2 CGI-111 - SCREW COVER (OPTIONAL) PVC - M3 CGI-112 3" 0 ANCHORS EQUAL LEG COVER/SHIM PVC - M4 - 0.700" X 0.040" BEAD GE1200 SILICONE SILICONE GE M5 - 0.700" X 0.040" BEAD DOW 791 OR 899 SILICONE DOW M6 - 0.700" X 0.040" BEAD DOW 983 OR 995 SILICONE DOW M7 - 2/ LITE SETTING BLOCK EPDM DUROMETER 80±5 SHORE A M8 - - PROTECTO WRAP WATERPROOFING OR EQUIV. - - M9 684 - ROLLER TRACK PVC - M10 CGI-128 2 PER SASH ROLLER HOUSING NYLON - M11 W23201NG - PILE WITH CENTER FIN WOOL ULTRAFAB OR EQUIV. M12 CGI-129 1 PER SASH EGRESS LOCK ALUM. SULLIVAN M13 CGI-131 2 PER SASH HANDLE RAIL END CAP NYLON M&M M14 391-N 1 PER SASH ANTILIFT BLOCK NYLON M&M M15 - OPTIONAL RETICULATED FOAM 30 PPI - - M16 CGI-134 - JAMB SPACER PVC PROTOTYPE OR EQUIV. M17 A30730401-32 1 PER WD. CAM LOCK ZINC TRUTH OR EQUIV. M18 CGI-132 2PER WD. 2" SASH STOP PVC PROTOTYPE M19 CGI-111 ® FR. HEAD SCREW COVER PVC PROTOTYPE M20 CGI-125 2PER SASH SASH CAM (B/T BALANCE) NYLON M&M M22 - VARIES HI-FLO WEEP COVERS PVC AMESBURY OR EQUIV S2 - 2 OR 3 PER CORNER # 10 X 1 1/4- LG. PHL. PH. SMS. ST/ST. ASSEMBLY SCREW - - S3 - 1 1/4" EMBED. # 8 X 1 1/2" LG. PHL. PH. SMS. FIN ANCHOR SCREW - S4 - 4 PER WD. # 8 X 1/2" PH. SMS. ST/ST BALANCE BRACKET SCREW - - S5 2 PER WD. # 8 X 1 " LG. FH. SMS. ST/ST. SPIRAL B. ASSEMBLY - - S6 - - # 6 X 1/2" LG. FH. SMS. ® CGI-133 & CAM LOCK - - S8 - 4 ®M. RAIL # 10 X 4" LG. PHL. PH. SMS. ST/ST. ASSEMBLY MEETING RAIL - - S9 - 2 PER ANTILIFT # 10 X 5/8" LG. PHL. PH. SMS. ST/ST. ANTILIFT SCREW - - MATERIAL PROPERTIES: Material Min. Fy Min. F. #14 Steel Screw 92 ksi 120 ksi 1/4" Elco UltraCon 155 ksi 177 ksi 1/4" DeWalt UltraCon+ 148 ksi 164 ksi 6063-T5 Aluminum 16 ksi 22 ksi A36 Steel 36 ksi 58 ksi ADDED BACKBEDDING TYPES - JR - 5/29/20 0 .N a� o Y Q o cn ^QO N 0 N o 0 Z > N a}op � z o 04 �e J i tl- F Q Q d <-j _ J M ON C Z u CMG Q W 00 Z (L W :, z U- L>a 2 O aoZarn C) N z p }aays CO) J rn U) o U 2 o! zen J Q z y 15 U) z U) a�oaS J Cp 0 ��Np UW NN Q w ow 0afCO Z �- Q c U) coM O w I- H CD 3 E'j0o�o LU Z = rn c Q j J U- O U) o OD QwQ O J - al}�l •asap sauag r 4, No.58705 �j S1AYRF %�� �'•.FLORiDF`.•'•���� //Illlllll0 A. LYNN MILLER, P.E. P.E.# 58705 2.440 2.440 2 113 .065 .120 --T1.015 �- 1.550 .70� s 050 TYP. 2.101 2.846 1.301 Typ_ IYP. 1.601 1.301 .065 T p. 1.220 1.007 Fl 1.680 -�i .864 LA 2.346 U. 1 065 .050 L:1.395-1E9 .700" GLAZING BEAD 1.155 1.155 T'P• 1.015 1.015 1.368 .745 E11 NAIL FIN ADAPTER 1.449 E13 FLANGE FRAME HEAD E3 FLUSH FRAME HEAD E4 MEETING RAIL 1.496 293 .060 L--1.413 A 1.015 1.015 1.788 1.140 1.140 .065 T(P. 2.264 1255 SCREW COVER 1.015 1.220 L I .080 065 4.430 IYP. 2.885 3.930 3.185 .065 NP' - 1.043 TrP. 3.685 2.885 E5 LOCK RAIL E19 SILL FILLER 1.786 j-1.450 Imo-- 2.440 2.440 ,180 .55�9 0 `I .050 E22 FLANGE FRAME SILL E2 FLUSH FRAME SILL 1.015 2.310 .0u- 5T IYP. 1.220 2.737 2.737 E23 FLANGE ADAPTOR .065 T p. .065 T p. E21 1.043 ALT. LOCK RAIL .490 -{�-� T- 2.505 2.613 2.505 2.613 1.892 065 I 2195 .70550 TfP. �l11-c --I .864 t� 5/16" GLAZING BEAD iTfP. ss1 .50o ss1 7oio-3.237 2.737 1.015 E14 FLANGE FRAME JAMB (MOVING) E20 FLUSH FRAME JAMB (MOVING) 1.043 I ,60 �r 1.395 1� .050 .065 811 .811 jam- E6 HANDLE RAIL M3 FLUSH FRAME COVER 2.505 .065 T(P. 2.505 .065 T(P. 1.025 1.015 1.015 1.395 745 1.000 .500 .065 1.745 E12 FLANGE FRAME JAMB 1.245 E1 O 1.015 F�- (FIXED) FLUSH FRAME JAMB (FIXED) SASH RAIL 0 s ocli Y Q N ^a?J a' N O Q w o O Z N N � i a}DQ � Z Z J N 78 } � O J } r I/M DJQ r QOc _ >- H �ON w U V o cl d ¢Wzcl)v aF"w Z _ tL wQ>v S O a � 2 ° 0 ce) Z 0 r #aa4S Roy Z f�A a Z Z a/oos 0 0 W C co J Z 0� co v Q=uM -6v�o of O vi Z x20� ooLL = Z o 40 Um2� N F X W r d' r al}d1 '7704 sapaS e\4°,14421Pt��f ' EF''' C f{ s No.58705 3 A. LYNN MILLER, P.E. P.E.# 58705 C