Loading...
HomeMy WebLinkAboutRoof Info Sheet ST:LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition(2020) Based on Section 1525:of the Florida Building Code=Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THEAECIUIRED DOCUMENTS AS'NOTED BELOW: Required Sections of Attachments.Required Roof System the .Permit Application See List Below Form_ Low Slope Application A,B,C 1,2,3,4,5.6.7 Prescriptive BUR-RAS'150 A;B,C 2,4,5,6,7 Asphaltic Shingles `-- .. .Y•_....._.- A,B,D I A4.5,6.7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6i7 Metal:Roofs _ A,B,D Wood Shingles and A,B,D }^ IA4.6,6.7 Shakes _ --------------- -- Other _ As Applicable 1,2,3,4,5.6,7 ATTACHMENTS REQUIRED As Applicable): 1, Fire Directory Listing Page 2. From'Product Approval: Front Page ? E Specific System Description Specific System Limitations + General Limitations _ Applicable Detail Drawings 3. Design Calculations,per Chapter 16,or if applicable,RAS 127 or RAS 128 4. .Other Component of Product Approval 5, iMunicipal Permit Application _ 6. Owners Notification for Roofing Considerations(Reroofing Only) 7, I Any Required Roof Testing/Calculatlon Documentation ; I I : i Form RoofinfoFeb21 Rev Feb,18.2021 I i i I Section A(General Information) Master Permit No. Process No, Contractors Name:_ 1 e oe swy_ &&qS. n!% License tl G GC l3 30 ro 5 3 lob Address_ ) ��� f�j Gy 1 CL ROOF CATEGORY ❑Low Slope 17 Mechanically Fastened Tile, E3 Mortar/Adhesive Set Tiles 13Asphaltic Shingles 13Metal Panel/Shingles OWood Shingles/Shakes 17 Prescriptive BUR-RAS 150 ROOF ROOF TYPE. C] New roof la Repair 13 Maintenance I'Reroofing O Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total(SF)�C/ Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and1evels,clearly identify dimensions of elevated pressure zones and location of parapets. I u y t -P F 00. m is E } . �y t 1 1+ � YS s r n<r • a _._du•kr> I I (F I f I i I I i i ST. LUCIE Section C(Low Slope'Roof). Surfacing: Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: .manufacturer Zone T:_"oc Q Lap,#Rows—@ "Do (if,a component is not used;ideritify'as"NA") Zone 1. if.oc Lap,#Rows System Manufacturer: - Zone 2--"oc @ Lapi:#'RbWs oo Product Approval No.: Zbne.3- oc@ Lap,#Rows—0 00 Number of Fasteners Per Insulation'Board. -Design Wind Pressures,From RAS 128'br calculations: Zone.1':—Zoh-e 1: Zone.2—Zone 3: Zone V: Zone 1: Zorie 2:___.,Zone 1 Illustrate Components Noted and Details as Applicable: Max.Design Pressure,from the specific product approval Wo.odblocking, Gutter, Edge Termination, Stripping, system:. Flashing, Continuous Cleat, Cant Strip, Base Flashing, C60riterflashirig,Coping,Etc.i Deck: Indicate: Mean Roof Height, Parapet Height,Height of Base Type,. Flashing,Component Material,m.Material'Thickne5s,Fastener Gauge'Thickness: Type,Fastener Spacing or Sub it Manufacturers Details that Comply with RAS 111 and Chapter 16.'. Slope: Arychor/Base SheeiR.No.df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Fr :Insulation Base Layer: Base Insultation Slie-and Thickness: Parapet gase.Insulation Faistener/Boncling Material: -Height Top.insulation Layer: Top Insulation Size and Thickness; FT. Top insulation Fastener/Bonding Material: Mean Base Sheet(s)&No.of Ply(s): Roof Base Sheet Fastener/Bondihg Material: Height, Ply:Sheet(s)'&No.'of Ply(s): Ply'Sheet Fastener./Bonding Material: Top Ply: Top:Ply Fastener/Bonding'Maibrlal: I Seaton D(Steep Slope.Roof System? Roof,SystemNlanufac2uCer. Vh� or) C�ifrUCiG 1nG Notice of Acceptance Number: Minimum Desjgn Mn r1 pressures,lf.AO i bte(From 1Z7 or.Calculations): 2one.1 done 2e>_ one 26: 2one.2r::-orte 3e. 9 yZone*3r: Deck;Type . .. I w c7 G� Type Untlerta►inenlr. Le,). Roof Slope 12 lnsuldflom Are Barder: Rtdge Ventitation? FastenO TypeA;Spal ft] � �A Gh Adhesive�!Pe' '�} - 1' 'Lype Cap Sheep. Mean Roof Height Sloe r Roof Covering Sy=me4-a Type 8i Sira Drip r Ede I !I is Section E(Tile Calculations); , For Morrient based tile systems,choose either Method 1 or 2.Compare the values for M,with the values from Mt.If the Mt values are greater than or equal to;the Mrvalues,for each'area of the roof,then the tile attachment method is acceptable.. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: !x;L = _? Mg: =Mli Product Approval Mi (Zone 2e: .,x).__" ,) Mg: =M Product Approval Mr (Zone 2n; ( 'x R --Mg: =Mm,_. .Product Approval Mf (Zone 2r. x X -Mg: =M;l, Product Approval Mr (Zone-3e: x), = _.I=Mg: =Ma. Product Approval Mr (Zone 3r. x) = Mg: =Mrer Product.Approval Mr .Method.2"Simplified Tile'Calculations Per Table Below" Requiretl Moment of Resistance(Mr).From Table Below Product Approval Mt M,required Moment Resistance* Mean Roof Height Roof Slope 15' 20' i 25, 30' -� 40' 212 34.4 36.5 38.2 39.7 42.2 3.12 32.2 ! 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 I 35.1 37.3 5.12 28.4 30,1� 31.6 32.8 34.9 - - _ 6:12 ._ 26.4 281) 29.4 80.5 .32.4 7:12 24:4 _25.(i::j 27.1 28.2 30,0 *Must be used In,conjunction.with a list of mornent based tile systems •For Uplift based the systems,use Method 3.Compare the values for F with the values for Fr If the F'values are greater.than or equal to the F,values,for each area of the roof'then the tile attachment method.-is acceptable. Method 3"Uplift Based Tile Calculations Per RAS.12T (Zone 1:. 'x L =x W:= )-W: cos r . =Fri Product Approval I" (Zone.2e: W:=_-__-)-W: cos r =Frze . Product Approval F' (Zone 2n: x L =x W:=L--__j-W: cos r =Frzi Product Approval F' (Zone 2r: x L =x W.- )-W: cos r =Fro Product Approval F' (Zone 3e: x L =x iNr=�)-W: .,cos r =Fray _ Product Approval F' ,(Zone 3r: x l =x Wc;-�}-W: cos r =Fr3r Product Approval F' i i _.�. - Whereto Obtain Information , Description Symbol Where to find Design Pressure Zon y es 1,2e,2n,2r,3e,3r From applicable table in RAS IV or by an engineering analysis prepared bPE based on ASCE 7- I Mean Roof Height j H Job'Slie Roof Slope I 9 Job Site Aerodynamic.Multiplier l a Pro duct Approval Restoring Moment due to Gravity Ma Product Approval _ - Attachment Resistance Mr 1 Product Approval Required Moment Resistance MB Calculated Minimum Attachment Resistance I F' Product Approval Required Uplift Resistance. F, I Calculated - Average Tile Weight W Product Approval - Tile Dimensions L=length W=width Product Approval All'calculations must be submitted to'the building official at the time of permit application. i