Loading...
HomeMy WebLinkAboutAPPROVED KrienerRoofWorkSheet9z ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of the Permit Application Form Attachments Required See List Below EPrescriptivee'BUJIRI-RAS A, B, C 1,2,3,4,5,6,7 50 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,6.6,7' Wood Shingles and Shakes A, B, D 1,2,4,5,6.7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval S. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 Section A (General Information) Master Permit No. Process No. Contractors Name: t cq n a A 6a rr r_+v rS License N 0& 0/ Job Address ROOF CATEGORY ❑ Low Slope 4Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE ❑ New roof ❑ Repair ❑ Maintenance ). Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) z F % i Total (SF) Z �) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Q w Q LL O O d' rn v co J LL w U ¢ w a O LL 0 Q O ¢ ¢ w 2 x S2 Z a V) �i LO V\ 54 Pv� �ratS LL 1I1�„'7P�S N 17 / 16 2 16 a s� 09 v M C s rn ca ca � r G1 cm- N Q ¢ n x r > F- ¢ w N LL i/i r1 N S T. LUCK Section C (Low Slope Roof) IN Fill in specific roof assembly components an identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: _ Zone 2: _Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1' _" oc @ Lap, # Rows— @ _" oc Zone 1 _" oc @ Lap, # Rows — ® _ oc Zone 24 oc @ lap, # Rows — ®_" oc Zone 3:_" oc @ Lap, # Rows_ @ _" oo Number of Fasteners Per Insulation Board: Zone 1':_Zone 1_Zone 2:_Zone 3:_ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc, Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Section E Mi a Calculations) For Moment based tile systems, choose either Method 1 o 2, ompare the values for M, with the values from Mr. If the Mr values are greater than or equal to the Mrvalues, for each area o e roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RA512T (Zone 1: _x;L_= _I- Mg: _=Md_ ProductApprovalM (Zone2e: _x2._= _J-Mg:_=M�_ Product Approval Mr (Zone2n: _x)._= _)- Mg: -=Mm,- Product Approval Mr (Zone 2r -x)._= J-Mg:_=M,&_ Product Approval MF (Zone 3e: :-x1L_=- Mg: _=My,- Product Approval Mr (Zone3r: x2.-=-)-MT-=M�- Product Approval Mr 'Method 2 "Simplified Tile Calculations Per Table Below" t Required Moment of Resistance (Mr) From Table Below.��_Product Approval Mt-l- 4 Mr required Moment Resistance' Mean Roof Height Roof Slope 5') 20' 25, 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 39.8 35.1 37.3 5:12 28. 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29A 30.5 32A 7:12 24.4 25.9 1 27.1 28.2 30.0 'Must be used in conjunction with a list of moment based tile systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:=_) -W:_ cos r= Fn (Zone 2e: x L=x W� _) -W:_ cos r =Frz• (Zone2n: xL =xW:= -W:_ cos r= Fret_ (Zone 2r: x L=x W _) -W:_ cos r =Fru (Zone 3e: x L=x W:=_) -W:_ cos rj. =Fae_ (Zone 3r: x L=x W _) -W:_ cos r= Frar Product Approval F' Product Approval F', Product Approval F', Product Approval F', Product Approval Product Approval r Where to obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope B Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Ma Product Approval Attachment Resistance Mr Product Approval Required Moment Resistance Ms Calculated Minimum Attachment Resistance I" Product Approval Required Uplift Resistance F, Calculated Tile Weight W Product Approval AAverage Tfle DimensionsI L=lengthW=width Product Approval All calculations must be submitted to the building official at the time of permit application. Section D (Steep Slope Roof System) Roof System Manufacturer: Z (rl ,('A1 V==Sn n ;Q, C6 U L S � Notice of Acceptance Number: `� Q b , HOT Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:_QLZone 2e:24..Zone 2n:—Ac I Zone Zr�Zone 3e::Zone 3r: Deck Type: Type Underlayment I <r, 1 S Rao�Slope: 12 Insulation: A Fire Barrier: f RidgeV ntlati�l Fastener Type &Spacutg: 4-45��//4, I-, Adhesive Type: �n / TA Type Cap Sheet 5 11 Mean Roof Height: 5 .\Roof Covering: I V t 50 0 -�-, 7-7 Type & Size Drip 1 Edge: YJ X 311