Loading...
HomeMy WebLinkAboutAPPROVED WS 35 - HVAC Corrections 6.10.2021 PROJECT #: KHOV-LELIA LOT: 35 SYSTEM BRAND - CARRIER: 3.0 TON Cu AHU MODEL : CA16NA037 FX4DNF037 DIMENSIONS - H X WX D 28-5/16 X 35.0 X 35.0 49-5/8" X 21-1/8" X 22-1/16" MCA 18.2 55.1 MAX FUSE (AMPS) 30 60 GREAT HEAT STRIP (KW) N/A 10 OWNER'S ROOM REF. LINE SIZE- ("O.D.) SUCTION 3/4 SUITE OS WIC REF. LINE SIZE- (" O.D.) LIQUID 3/8 W 8 X4 SEER: 16.0 14 SENSIBLE BTU'S: 28,500 CFM ICI ^^ r, ' 6 700 12"X12" H � W LATENT BTU S. 12"X12„153 9»� CFM TOTAL BTU'S: 35,200 CFM 16"X16" J W RH 14' 16"X16" �I w RH H 9"o EXHAUST FAN SCHEDULE » #1 50 CFM w/4" T-FIN-V.T.O. 8 x 4 W I 21 0 _ CFM ° 4»� doll FDININGDUCTWORK - FLEXIBLEOWNER'S _ of AREA BATH KITCHEN ° R-FACTOR- 6 ------- ° I NOTE: DUCTWORK TRUNK LINE o ° AND DROP LOCATIONS MAYVARY FROM PLAN DUE TO TRUSS 00 L_______1_J CONFIGURATIONS 0 12"X8" 222 I CFM I I I NOTE: BEDROOM 2 8990 -------------------- 1. REFRIGERANT LINES w/1/2"T-CELL INSULATION ---------------------- 2. USE 3/4"SCH 40 PVC FOR CONDENSATE DRAINS. CONDENSATE DRAIN OUTLETS TO BE MINIMUM 121,OFF SLAB 10"X6" 14"0 3. AUXILLARY FLOAT SWITCHES ON AHU'S 73 BAT t7o 4"0 CFM BAT 8"X4" 50 CFM 0 8 X4" 1 1 8"X4" Q C ------ ----- -, 5 Ld �- CEILING 7990 )14"X6" CFM w w 0 CU RH 4 o Ln 0 0 ° r� rn 2 18„ 4'� �3 °' z � _ En » 140 ( ) --- o c3 � L` � o � ov (2)14 X6' RH ------ w wU Z O � O .LQ SUPPLY R � z z o I PLENUM o a a ,L oN on E 4990 8 4„ 2-20"X6" r m ^^�-_ o 5 RH 3: C Lo AL CONDENSATE DRAIN CFfa- Q a °.�' '- o AHU TO EXTERIOR $ 0 �` ao E `� X 3 0 & REF. LINES 7"0 ir n a_ Lj_ 3 v TO AHU 7»O 4" DRYER OPEN TO V.T.O. R/A GRILL 10"X6 28 GAUGE 8 CFM GALV. PIPE 10"X6" 75 4»0 —METAL STAND CFM BEDROOM 3 XT STE PLUS REVISIONS BEDROOM N0. DESC. DATE AHU MOUNTING DETAIL ' 8 2)1 ' C6" ��0 „X4„ 4 DR�Eo RH 5 8 GAUG SCALE: N.T.S. CFM ALV. PIP ------------------- ID I 12"X8" 143 (P��aGF GARAGE CFM DRAWN BY: DL/GM/HP CHECKED BY: CS DATE: 5-2021 THE DESIGN PLAN & SPECIFI- CATIONS SUBMITTED HERE WITH EXT STE PLUS ARE THE SOLE PROPERTY OF co � v..V, • LINDSTROM AIR CONDITIONING ,: :•'' � INC. & ARE NOT TO BE REPR- MIN.4°CONCRETE SLAB <: SLAB c�o-o° LIVING ROOM ODUCED WITHOUT THE WRITTEN F.F.OF HOUSE PERMISSION. TIE DOWN CLIPS WITH THESE DOCUMENTS ARE L/4°xi-3i4°TAPCONINSLAB SPECIFICALLY SUBMITTED FOR #12 SCREWS INTO CU CABINET THE EXCLUSIVE USE OF THE LINDSTROM AIR CONDITIONING PER TIE DOWN SPEC'S INC. IN THE CONSTRUCTION OF DESIGNED SYSTEMS. LINDSTROM A/C DESIGNS UNDER - F.S. 489 & F.S. 471 CU MOUNTING DETAIL SHEET TITLE: SCALE: N.T.S. MECHANICAL PLAN MECHANICAL PLAN SHEET NO.: SCALE: 1 /4"= 1 '-O" FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-LELIA Builder Name: KHOVNANAIN HOMES Street: 5125 ARMINA PLACE Permit Office: City,State,Zip: FORT PIERCE, FL, Permit Number: Owner: LELIA MODEL LOT 35 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2} 1. New construction or existing New(From Plans) 10. Wall Type$1844.9 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1508.90 ft2 b. Frame-Wood,Adjacent R=11.0 336.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11.Ceiling Types (1917.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1917.00 ft2 6. Conditioned floor area above grade(ft2) 1917 b. NIA R= ft2 Conditioned floor area below grade(ft2) 0 c. NIA R= ft2 7. Windows(201.8 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbi, U=0.28 159.83 ft2 a. Sup:Attic, Ret: LAUNDRY,AH:LAUNDRY 6 250 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 42.00 ft2 13.Cooling systems kBtulhr Efficiency SHGC: SHGC=0.34 a. Central Unit 35.2 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.570 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.308 a. Electric Strip Heat 32.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1917.1 sqft.) Insulation Area EF:0.950 a. Slab-On-Grade Edge Insulation R=0.0 1917.10 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16. Credits Pstat Glass/Floor Area: 0.105 Total Proposed Modified Loads: 59.66 PASS Total Baseline Loads: 61.14 1 hereby certify that the plans and sp ifcations covered by Review of the plans and this calculation are in compliance w the Florida erg specifications covered by this Code. calculation indicates compliance ,,,,��''F with the Florida Energy Code. W PREPARED BY: Before construction is completed DATE: ! this building will be inspected for I �! compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. WE � OWNER/AGENT: BUILDING OFFICIAL: DATE: 6/10/2021 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/10/2021 12:13 PM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KHOV-LELIA Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1917 Lot# Owner Name: LELIA MODEL LOT 35 @ WA Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: KHOVNANAIN HOMES Rotate Angle: 0 Street: 5125 ARMINA PLACE Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp lnt Design Temp Heating Design Daily Temp 1/ Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1917 16614.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfllID Finished Cooled Heated 1 EXT STE LIV PLUS 199 1765.1 No 0 4 1 No Yes Yes 2 WIC STE PLS BED 25 220 No 0 1 No Yes Yes 3 EX STE PLUS BED 132 1161.6 No 0 1 No Yes Yes 4 EX STE BATH 54 475.2 No 0 1 No Yes Yes 5 FOYER 81 712.8 No 0 1 No Yes Yes 6 HALL BATH 54 475.2 No 0 1 No Yes Yes 7 LAUNDRY 77 677.6 No 0 1 No Yes Yes 8 BED 3 126 1108.8 No 1 1 No Yes Yes 9 BED2 126 1109 No 1 1 No Yes Yes 10 KIT GREAT RM DI 672 5544.8 No 0 1 No Yes Yes 11 M BATH 95 836 No 0 1 No Yes Yes 12 MASTER SUITE 210 1848 No 2 1 No Yes Yes 13 MASTER WIC 66 580.8 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio EXT STE LIV PL 46 ft 0 199.3 ftz ____ 0 1 0 2 Slab-On-Grade Edge Insulatio WIC STE PLS BE 4.5 ft 0 25 ftZ _--- 0 1 0 3 Slab-On-Grade Edge Insulatio EX STE PLUS B 8.5 ft 0 132 ftZ __-_ 0 1 0 4 Slab-On-Grade Edge Insulatio EX STE BATH 1 ft 0 54 ftZ -_-_ 1 0 0 6/10/2021 12:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio FOYER 19 ft 0 81.3 ft2 1 0 0 6 Slab-On-Grade Edge Insulatio HALL BATH 1 ft 0 54 ftz ---- 1 0 0 7 Slab-On-Grade Edge Insulatio LAUNDRY 7.5 ft 0 77 ft2 ---- 1 4 0 8 Slab-On-Grade Edge Insulatio BED 3 22.5 ft 0 126 ftz ___- 0 1 0 9SIab-On-Grade Edge Insulatio BED 2 12.5 ft 0 126 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulatio KIT GREAT RM 43.5 ft 0 672 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio M BATH 9 ft 0 94.5 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio MASTER SUITE 28 ft 0 210 ft2 ---- 0 1 0 13SIab-On-Grade Edge Insulatio MASTER WIC 6 ft 0 66 ft2 ____ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2076 ft2 0 W Medium N 0.9 No 0.9 No 0 22.6 ATTIC J # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1917 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) EXT STE LIV PL 30 Blown 199 ft, 0.1 Wood 2 Under Attic(Vented) WIC STE PLS BE 30 Blown 25 ft2 0.1 Wood 3 Under Attic(Vented) EX STE PLUS B 30 Blown 132 ft2 0.1 Wood 4 Under Attic(Vented) EX STE BATH 30 Blown 54 ft2 0.1 Wood 5 Under Attic(Vented) FOYER 30 Blown 81 ft2 0.1 Wood 6 Under Attic(Vented) HALL BATH 30 Blown 54 ft2 0.1 Wood 7 Under Attic(Vented) LAUNDRY 30 Blown 77 ft2 0.1 Wood 8 Under Attic(Vented) BED 3 30 Blown 126 ft2 0.1 Wood 9 Under Attic(Vented) BED 2 30 Blown 126 ft2 0.1 Wood 10 Under Attic(Vented) KIT GREAT RM 30 Blown 672 ft2 0.1 Wood 11 Under Attic(Vented) M BATH 30 Blown 95 ftz 0.1 Wood 12 Under Attic(Vented) MASTER SUITE 30 Blown 210 ft2 0.1 Wood 13 Under Attic(Vented) MASTER WIC 30 Blown 66 ft2 0.1 Wood 6/10/2021 12:13 PM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS F Adjacent Space cavity Width Height Sheathing Framing Solar Below# Ornt In wall Typ'. 1 SE Exterior Concrete Block-Int InsEXT STE LIV 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0 2 SW Exterior Concrete Block-Int InsEXT STE LIV 4.1 15 4 10 0 153.3 ft2 0 0 0.5 0 3 SW Exterior Concrete:Block-Int InsiBX STE PLU 4.1 7 8 10 0 76.7 ft2 0 0 0.5 0 4 SE Exterior Concrete Block-Int Insul FOYER 4.1 6 4 9 4 59.1 ft2 0 0 0.5 0 5 SW Exterior Concrete Block-Int InsuI FOYER 4.1 11 4 10 0 113.3 ft2 0 0 0.5 0 6 NE Exterior Concrete Block-Int Insul BEd 3 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0 7 NE Exterior Concrete Block-Int InsuI BED 2 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0 8 SW Exterior Concrete Block-Int InstKIT GREAT 4.1 25 2 10 0 251.7 ft2 0 0 0.5 0 9 NW Exterior Concrete Block-Int InsLKIT GREAT 4.1 15 1 9 4 140.8 ft2 0 0 0.5 0 `10 NE Exterior Concrete Block-Int Insul M BATH 4.1 8 9 9 4 81.7 ft2 0 0 0.5 0 11 NE Exterior Concrete Block-Int InsMASTER SUI 4.1 14 1 9 4 131.4 ft2 0 0 0.5 0 12 NW Exterior Concrete Block-Int InsMASTER SUI 4.1 13 1 9 4 122.1 ft2 0 0 0.5 0 13 NW Exterior Concrete Block-Int InsUASTER WI 4.1 5 10 9 4 54.4 ft2 0 0 0.5 0 14 NW Garage Frame-Wood KIT GREAT 11 36 0 9 4 336.0 ft2 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated EXT STE LIV None .39 3 2 6 8 21.1 ft2 2 SW Insulated EXT STE LIV None .39 3 2 6 8 21.1 ft2 3 NW Wood KIT GREAT None .39 3 2 6 8 21.1 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 1 Metal Double(Tinted) Yes 0.28 0.3 N 22.9 ft2 1 ft 0 in 1 ft 0 in None None 2 SW 3 Metal Double(Tinted) Yes 0.28 0.3 N 23.0 ft2 6 ft 0 in 1 ft 0 in None None 3 SW 5 Metal Double(Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 4 NE 6 Metal Double(Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft Gin 1 ft 0 in None None 5 NE 7 Metal Double(Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 6 SW 8 Metal Double(Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft 0 in 1 ft 0 in None None 7 NW 9 Metal Double(Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft 0 in 1 ft 0 in None None 8 NW 9 Metal Double(Tinted) Yes 0.55 0.34 N 42.0 ft2 1 ft 0 in 1 ft 0 in None None 9 NW 12 Metal Double(Tinted) Yes 0.28 0.3 N 22.9 ft2 1 ft 6 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 380 ft2 380 ft2 64 ft a ft 1 6/10/2021 12:13 PM EnergyGaugeQ USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000385 1938.4 106.35 199.65 .1304 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 32 kBtulhr 1 sys#1 COOLING SYSTEM ## System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit] Split Singl SEER: 16 35.2 kBtulhr cfm 0.81 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPrit Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ftz LAUNDRY 1 ftz Default Leakage LAUNDRY (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [ Jan Feb [ ]Mar Apr May X Jun ri Jul X Aug Se Oct Nov Dec Heatin 4X Jan f X Feb [X]Mar f Apr May Jun Jul AuSep OctNovX Dec Ventin Jan [ Feb [X Mar [X A r Ma Jun Jul Aug Sep [X Oct (X Nov j Dec 6/10/2021 12:13 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BED 2 Default(8 tbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BED 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC BED 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 4 Default(8 Ibs/sq.ft, ft2 ft 0.3 BED 4 Default(8 Ibslsq.ft. ft2 ft 0.3 WIC BED 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibslsq.ft. ft2 ft 0.3 KITCHEN BREAKF Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibslsq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 GAR HALL GALLE Default(8 Ibslsq.ft, ft2 ft 0.3 POWDER Default(8 Ibslsq.ft. ft2 ft 0.3 GREAT ROOM Default(8€bs/sq.ft. ft2 ft 0.3 CLUBROOM Default(8 Ibslsq.ft. ft2 ft 0.3 LIBRARY Default(8€bslsq.ft. ft2 ft 0.3 MASTER SUITE Default(8 ibs/sq.ft. ft2 ft 0.3 HIS WIC Default(8Ibs/sq.ft. ft2 ft 0.3 HIS BATH Def2ult(8 Ibslsq.ft. ft2 ft 0.3 HER TIOLET Def2ult(8€bs/sq.ft. ft2 ft 0.3 HER BATH Default(8 1sls .ft. ftz ft 0.3 HERS 6/10/2021 12:13 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX` = 98 The lower the EnergyPerformance Index, the more efficient the home. 5125 ARMINA PLACE, FORT PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block-Int Insul, Exterior R=4.1 1508.90 ft2 b. Frame-Wood,Adjacent R=11.0 336.00 ft2 3. Number of units,if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area a. Under Attic(Vented) R=30.0 1917.00 ftz 6. Conditioned floor area(ft2) 1917 b. NIA R= ft2 7. Windows** Description Area c. R= ft2 a. U-Factor: Dbl, U-0.28 159.83 ft2 12. Ducts, location &insulation level R ftz SHGC: SHGC=0.30 a. Sup:Attic, Ret: LAUNDRY,AH: LAUNDRY 6 250 b. U-Factor: Dbl, U=0.55 42.00 ft2 SHGC: SHGC=0.34 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 35.2 SEER:16.00 SHGC: d. U-Factor. NIA ft2 14. Heating systems kBtulhr Efficiency SHGC: a. Electric Strip Heat 32.0 COP:1.00 Area Weighted Average Overhang Depth: 1.570 ft. Area Weighted Average SHGC: 0,308 8. Skylights Description Area 15. Hot wafer systems a. Electric Cap: 50 gallons a. U-Factor(AVG): NIA ft2EF:0.95 SHGC(AVG): NIA b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1917.10 ft2 Credits(Performance method) Pstat b. NIA R= ft2 c. NIA R= ft2 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) .y0 © in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. „,,, •.`,": ';`+";, Builder Signature: � " Date-. 6/10/2021 i Address of New Home: 5125 Armina Place City/FL Zip: Ft. Pierce WV s. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/10/2021 12:14 PM EnergyGauge&USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 Project Summary Date: o•iy Entire House By: LINDSTROM A'"`°"°' Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone:954-421-4117 Fax:954-420-0064 Web:www.lindstromair.com Project • • For: KHOVNANIAN HOMES Notes: LOT 35- LELIA MODEL Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22320 Btuh Structure 21097 Btuh Ducts 3357 Btuh Ducts 5423 Btuh Central vent (42 cfm) 1298 Btuh Central vent (42 cfm) 695 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26975 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25855 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3149 Btuh Ducts 1565 Btuh Central vent (42 cfm) 1762 Btuh Heatingg Coolingg Outside air Area(ft2) 1917 1917 Equipment latent load 6476 Btuh Volume (ft3) 16870 16870 Air changes/hour 0.38 0.20 Equipment Total Load (Seril 32331 Btuh Equiv. AVF (cfm) 107 56 Req. total capacity at 0.81 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade Trade Model 10 KW Cond CA16NA037 AHRI ref Coil FX4DNF037 AHRI ref Efficiency 100 EFF Efficiency 16 SEER Heating input 7.9 kW Sensible cooling 28500 Btuh Heating output 26975 Btuh Latent cooling 6700 Btuh Temperature rise 20 OF Total cooling 35200 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w riQ"tsoft" 2021-Jun-10 12:55:17 ^--I , . 11--.1..,,ill,., Right-Suite@ Universal 2019 19.0.12 RSU08398 Page 1 ACCA S:\PROJECTS ENERGY\A-MANUAL J\KHOV-LELIA-PSL.rup Cale=MJ8 Front Door faces: N