Loading...
HomeMy WebLinkAboutCompaction testAndaman In -Place Density R Ort Client: Project: not% & Associates, On Permit # 2103.0505 Renar Development Corp. 113-15-66-5434B Report Date: 06/24/2021 3725 S. East Ocean Boulevard, Suite 101 Momingside Residential Lots Port St. Lucie Branch Test Method: ASTM D6938 Stuart, FL 34996 Fort Pierce Florida Registration No. 5950 460 NW Concourse Place, Unit 1 _ Fort Pierce , FL Port St. Lucie, FL 34966�/- Phone:772-678-OD72 ` V Test Results Maximum In Place In Place Optimum Dry In Place Dry Wet Probe Test # Retest Of Test Date Proctor ID Method Soil Classification Moisture % Density (pcf) Moisture (%) Density Density (pcf) Depth Percent Compaction Min Comp. p (in) (%) Remark 467 06/07/21 21-114 A - 9.5 117.0 11.0 116.2 129.0 12 99 95 Pass Modified 468 06/07/21 21-114 A - 9.5 117.0 4.7 112.3 117.6 12 96 95 Pass (Modified) 469 06/07/21 21-114 A - 9.6 117.0 12.7 114.9 129.5 12 98 95 Pass (Modified) 470 06/07/21 21-114 A - 9.5 117.0 13.8 113.3 128.9 12 97 95 Pass Modified 471 06/14/21 21-114 A - 9.5 117.0 13.2 113.3 128.3 12 97 95 Pass (Modified) 472 06/14/21 21-114 A - 9.5 117.0 11.2 114.0 126.8 12 97 95 Pass (Modified) 473 06/14/21 21-114 A - 9.5 117.0 12.8 115.4 130.2 12 99 95 Pass (Modified) 474 06/14/21 21-114 A - 9.5 117.0 13.1 114.E 129.6 12 98 95 Pass (Modified) 1 Test Information Test # Test Location Elevation Reference Gauge Make / Model ! SN / Calibrated Field Technician 467 Building - Slab on Grade: Lot #75, 9724 Starboard Dr. Slab SE Area -1.0 Top of Subgrade CPN / MC-3 l M330907151 / Tech, Port St. Lucie 468 Building - Slab on Grade: Lot #75, 9724 Starboard Dr. Slab NE Area -1.0 Top of Subgrade CPN / MC-3 / M330907151 / Tech, Port St. Lucie 469 Building - Slab on Grade: Lot #75, 9724 Starboard Dr. Slab NW Area -1.0 Top of Subgrade CPN / MC-3 / M330907151 / Tech, Port St. Lucie 470 Building - Slab on Grade: Lot #75, 9724 Starboard Dr. Slab SW Area -1.0 Top of Subgrade CPN / MC-3 I M330907151 / I Tech, Port St. Lucie 471 Building - Continuous Footing: Lot #75, 9724 Starboard Dr. Footing - N -1.0 Top of Subgrade CPN / MC-3 / M330907151 /J.Tech, ch, Port St. Lucie 472 Building - Continuous Footing: Lot #75, 9724 Starboard Dr. Footing - W -1.0 Top of Subgrade CPN / MC-3 / M3309071 Port St. Lucie 473 Building - Continuous Footing: Lot #75, 9724 Starboard Dr. Footing - S -1.0 Top of Subgrade CPN / MC-3 I M33 Port St. Lucie 474 Building -Continuous Footing: Lot #75, 9724 Stafioard Dr. Footing- E -1.0 Top of Subgrade CPN / MC-3 / 5 Y rt St. Lucie Remarks Comments I ®® �,• ��C ��`.� ®® Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Digitally signed Gauge calibration data on file with the testing agency. 11W j0byDanJ i No. 63911 Zrallack: Date: 2021.06.24 STATE OF Uj 4x®^ 11:28:04-04'00":- ®®®��&S3!� e 'JR1cI� QO®®®� 6/24/21 AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL` O Page 1 1 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERMUNIN( of OUR WRITTEN APPROVAL.