HomeMy WebLinkAboutCompaction testAndaman In -Place Density R
Ort Client:
Project:
not% & Associates, On Permit # 2103.0505
Renar Development Corp.
113-15-66-5434B
Report Date: 06/24/2021
3725 S. East Ocean Boulevard, Suite 101
Momingside Residential Lots
Port St. Lucie Branch Test Method: ASTM D6938
Stuart, FL 34996
Fort Pierce
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
_
Fort Pierce , FL
Port St. Lucie, FL 34966�/-
Phone:772-678-OD72
` V
Test Results
Maximum
In Place
In Place
Optimum
Dry
In Place
Dry
Wet
Probe
Test #
Retest
Of
Test Date
Proctor ID
Method
Soil
Classification
Moisture
%
Density (pcf)
Moisture
(%)
Density
Density
(pcf)
Depth
Percent
Compaction
Min Comp.
p
(in)
(%)
Remark
467
06/07/21
21-114
A
-
9.5
117.0
11.0
116.2
129.0
12
99
95
Pass
Modified
468
06/07/21
21-114
A
-
9.5
117.0
4.7
112.3
117.6
12
96
95
Pass
(Modified)
469
06/07/21
21-114
A
-
9.6
117.0
12.7
114.9
129.5
12
98
95
Pass
(Modified)
470
06/07/21
21-114
A
-
9.5
117.0
13.8
113.3
128.9
12
97
95
Pass
Modified
471
06/14/21
21-114
A
-
9.5
117.0
13.2
113.3
128.3
12
97
95
Pass
(Modified)
472
06/14/21
21-114
A
-
9.5
117.0
11.2
114.0
126.8
12
97
95
Pass
(Modified)
473
06/14/21
21-114
A
-
9.5
117.0
12.8
115.4
130.2
12
99
95
Pass
(Modified)
474
06/14/21
21-114
A
-
9.5
117.0
13.1
114.E
129.6
12
98
95
Pass
(Modified)
1
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model ! SN / Calibrated
Field Technician
467
Building - Slab on Grade: Lot #75, 9724 Starboard Dr. Slab SE Area
-1.0
Top of Subgrade
CPN / MC-3 l M330907151 /
Tech, Port St. Lucie
468
Building - Slab on Grade: Lot #75, 9724 Starboard Dr. Slab NE Area
-1.0
Top of Subgrade
CPN / MC-3 / M330907151 /
Tech, Port St. Lucie
469
Building - Slab on Grade: Lot #75, 9724 Starboard Dr. Slab NW Area
-1.0
Top of Subgrade
CPN / MC-3 / M330907151 /
Tech, Port St. Lucie
470
Building - Slab on Grade: Lot #75, 9724 Starboard Dr. Slab SW Area
-1.0
Top of Subgrade
CPN / MC-3 I M330907151 /
I
Tech, Port St. Lucie
471
Building - Continuous Footing: Lot #75, 9724 Starboard Dr. Footing - N
-1.0
Top of Subgrade
CPN / MC-3 / M330907151 /J.Tech,
ch, Port St. Lucie
472
Building - Continuous Footing: Lot #75, 9724 Starboard Dr. Footing - W
-1.0
Top of Subgrade
CPN / MC-3 / M3309071
Port St. Lucie
473
Building - Continuous Footing: Lot #75, 9724 Starboard Dr. Footing - S
-1.0
Top of Subgrade
CPN / MC-3 I M33
Port St. Lucie
474
Building -Continuous Footing: Lot #75, 9724 Stafioard Dr. Footing- E
-1.0
Top of Subgrade
CPN / MC-3 / 5 Y
rt St. Lucie
Remarks
Comments
I
®® �,• ��C
��`.� ®®
Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter".
Digitally signed
Gauge calibration data on file with the testing agency.
11W j0byDanJ i No. 63911
Zrallack:
Date:
2021.06.24 STATE OF Uj 4x®^
11:28:04-04'00":-
®®®��&S3!�
e 'JR1cI� QO®®®� 6/24/21
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL`
O Page 1 1
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERMUNIN(
of
OUR WRITTEN APPROVAL.