HomeMy WebLinkAboutNOBLE GENERATORINCLUDES: • True Power' Electrical Technology • Two-line multilingual digital LCD Evolution'" controller (English/Spanlsh/French/Portuguese) • Two transfer switch options available: 100 amp,16 circuit switch or 200 amp service rated smart switch • Electronic governor • Standard VA-F1' connectivity available on 16kW and 20kW-1 models and 22kW -2 model • System status & maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing Installation as close as 16 in (457 mm) to a structure." •must be located away from doors, windows, and fresh air intakes and in accordance with local codes. https://assets.swd.org/library/Dlrectory0lU'stedProducts/ ConstmcGonindustry/973 Do0 204_13204-01-01_Aev9.Pdf GENERAC & mac& t^t�+s n,��-.�s a?s'4'•r' GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007035-0, G07035.1, G07069, G00706.1 (Aluminum -Bisque) -18 kW 60 Hz G007037-0, G007037-1 (ANminum -Bisque) -16 kW 601-iz G07036-0, G07038-1, G07039-0. G07039-1 (At7umBsque) 0 kW 60 Ht 07mnum q260 HZ G07043-0,G 07043-1, G07043-2(minum-Bsue)-22 kW 60 Hz EATU RES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- O erac's success in providing the most reliable generators possible. Generac's G- Force engine lineup offers added peace of mind and reliability for when it's needed the most The G-Farce series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5%Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O O TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA MOI-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY O MOBILE LINK— CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link WI-FI allows users to monitor the status of the generator from anywhere in the world using a smartphone, tablet, or PC. Easily access informa= ,lion such as the current operaling status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. NNzocte; CEfL or CUL certification o)g apples to unbundled units and units Eil ad with fede the USAonry.es. Units packaged with the Smart Switch are SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac mod- els. It provides optimized FAST RESPONSE to changing load conditions and MMN(I- MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at 31%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the small- est electronic component. GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with Its own transfer systems and controls for total system compatibility. GENERAL �®'`. ©mot �• �IPROMISE `—_ O GENERAL' 16/20/22 kW Features and Benefits Engine • Generac G-Force design Maximizes engine "breathing" for Increased fuel efficiency. Plateau honed cylinderwalis and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low all pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficientlythan arevolving armaturegeneralor. • Skewed stator Produces a smooth output waveform far compatibility with elecbanic equipment. • Displaced phase excitation Maximizes motor starling capability. • Automatic voltage regulation Regulating outpulvoltage to :1% prevents damaging voltage spikes. • 'UL 2200 listed For your safety. Transfer Switch (f applicable) f • • • Fully automatic NEMA OR Remote mounting Transfers vital electrical loads to the energized source a power. Can be Installed inside or outside for maximum flexibility. Mounts near an existing distribution panel for simple, law -cost installation. Evolution"' Controls • AUTO/MANUAL/OFF illuminated buttons Selects the operating mode and provides easy, ata-glance status indication in any condition. • Two-linemultilingual LCD Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user Interface for programming and operations. 65% dropout, 80% pick-up, of standard voltage. • Utility voltage sensing Constantly monitors utility voltage, setpoints Constantly monitors generator voltage to verify the cleanest power delivered to the home. • Generator voltage sensing Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 • Utility Interrupt delay seconds by a qualified dealer. Verifies engine is ready to assume the load, setpoint approximately 5 seconds. • Engine warm-up Allows engine to cool prior to shutdown, setpolnt approximately 1 minute. • Engine cool -down Operates engine to prevent all seal drying and damage between power outages by running the generatorfor • Programmable exercise 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only when needed at varying rates depending an outdoor air temperature. • Smart battery charger Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstaning • SAE weather protective enclosure winds up to 1S0 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access textured epoxy paint for added durability. to all routine maintenance Items. Electrostatically applied • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation, as close as 18In (457 mm) away from a structure. • Small, compact, attractive GENERAC` 16/20/22 kW Features and Benefits Installation System • 14In (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54Installation requirements. Connectivity (WI-Fi equipped models only) • Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. • Ability to view generator Fxercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery Information Built In battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC` 16/20/22 kW Specifications Generator Model 6007035-01-1,0007036-0/-1, G007MM-1,13007039-0/-1 G007037-0/-1 (16 )A RO km _ _ _ 16/20/22 kW Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated,mechanically-held contacts for fast, positive connections. • Rated for all classes of load, 100% equipment rated, both Inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both capper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMAIUL SR aluminum outdoor enclosure allows for Indoor or outdoor mounting geAbility. • Multi listed for use with 1 in standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton, and Square D for the most flexible and cost effective install. Dimensions W1WidW2 13.510.5 JDeplh 6.91 26.67 Wire Ranges Conductor lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#14 -Function of Evoludon contro0er Exercise can be set to weekly or monthly GENE switch Options G007037.01.1 (16 kM/G007039.0/-1,(20 kW)/ Service Rated Smart Switch Features model GOU7043A/ 1/ 2 22 • Includes digital power management technology (OPM) standard.' t lter' ry. ,�.� "`f! r • Intelligently manages up to four air conditioner loads with no additional hardware. current rating (amps) 200 �. • Up to eight additional large (240 VAC) loads can be managed when used in- M ent Modules(SMMs) Utility voltage monitor (fad)* Aft conjunction with smart anagem • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load, t00% equipment rated, both Inductive and resistive. • 2-pole, 250 VAC contactors • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL SR aluminum outdoor enclosure allows for Indoor or outdoor mounting flexibility. Dimensions Height Width Depth HI H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 cm 57.95 76.45 26.67 3429 17.55 Wire Ranges 5350i tor Lug Neutral Lug Ground Lug M-#66350MCM-#6 210-#14 minutes' Lug range *Function of Evolution controller Ennelse can be set to weekly or monthly #6 ITHOUT (ON -GRADE APPLiCATIQN.S QP PAD DIMENSIONS: a � WINDTABLE NYNSnaxnHlMQ C uw 7 —SPIF 0.II nanR 03F NOSYIE I c o a c o Lx,ly c o >.61AM iimWMD LINw MMMN4NNPmNdL6"Slm WiatlMLa NVAW.j.,W,THO.UT- F— T —1 d.WIxa Y00R aMUi] WIDtx FU1GlX xf611] WFY.9(1 a441WgtStitWf sa�ai. nl ws a.mo.Wsanamsml Gevna6139.6164N61 mM uM 16M +aw- 1 m- 9a ar 2W SLae• law' lam- a9roa 14so l3➢a• nM- laW- Snb 6fl3G n.Wmll tFM SSN' IaW ]aln' aVb u® ra..a.Wsdna Wsms w,aaWsa]IaozseW un.oa WsenawsWz aeunam6n9a Wf]ie a...aaawswaimfss: \.I+RFSuovls nM nM mM SOM zlM n99• nw• mw• +ss rt. Ism Sze9• 2W lam• ma. 2m ne9• nw• law• 21fa 2l9 lLW M14f0' lflm• 516b +0.19 SL la s . .al, lwoM rt +]' yaV�Wml1)au.m] ]6M z J JA +4s 'avWlvua9WW) u�..aaW)ma]als mM nM n m Inm. ssa- lam• lam- .mb S>Ja wmaW]rnama uM um• law• SaW tom. aw ANCHOR TO PAD SCHEDULE: auewwa vdscv]vnov xmT� 1. M (l}91tl'➢OPVNI F' COINAnG $plFµwl]I Oa F1 M x3XJ FIRLfYADm a wtl[aFF,Y lW4�ISW1 O,^- a RNFatl]mII�2P1fmJ.9LlM1a d Y..VEaF09teVn:lA9WI1XO WnaLan oavvinsemeaem]xdae,ert> 11 a d GENERAC0 Automatic Transfer Switches Service and Non -Service Rated Automatic Transfer Switches Models: RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW200A3 COus LISTED r-... Description Generic Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution " or NexusTM Controller. The 100 and 200 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 amp open transition switch is only available in a service rated equipment configuration. Standard Features Service rated (RTSW) Generac Automatic Transfer Switches are housed in an aluminum NEMANLType 311 enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty General; Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a five year limited warranty. * Non -service rated (RTSC) switches are housed in a steel enclosure. Load Management Technology Through the use of the Integrated Smart NO Module (SACM), these switches have the capability to manage up to four individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with extemal Smart Management Modules, a total of eight more loads can be managed, providing the most Installation efficient power management options available. fi 2�so �{ 9001- ._.�....c.�.vvw*asF•N°R�" 'ice zoos 100-200 Amps, Single Phase Functions All timing and sensing functions originate in the generator controller, GENERAC° Automatic Transfer Switches. Utility Voltage Drop -out <65% Timer to Generator Start 10 Second Factory Set, Adjustable Between 2 -1,500 Seconds by a Qualified Dealer* Engine Wannup Delay 5 Seconds Standby Voltage Sensor 65%for 5 Seconds Utility Voltage Pickup >80°% Re -transfer Time Delay 15 Seconds Engine Cooldown Timer 60 Seconds Exerciser Nexus^:12 Minutes Weekly Evolution-: to 12 Minutes Adjustable, Wee*Bi-weeldy/MOnthly The Transfer Switch can be Operated Manually Without Power Applied * When used in conjunction with units utilizing Evolution- controls Specifications Model RXSC10OA3 RXSW100A3 RXSW15UA3 RXSC200A3 t1XSW200A3 Amps 100 100 150 200 200 Voltage 120/240, to 120/240,10 120/240,10 120/240,1ID 1P0/240, ie Load Transition (Automatic) Open Transition OperiTransition Service Rated OpenTransi0an Service Rated OpenTtans'on open Transition Service Rated Enclosure Type NEMANL3R NEMA/UL3R NEMANL3R NEMA(UL3R NEMA/ULSR UL Rating UUCUL UL UL UL/CUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 Lug Range 2/0 - #14 250 MGM - #6 100-200 Amps, Single Phase Dimensions GENERAC® Automatic Transfer Switches Model RXSC100A3 RXSW700A3 RXSW150A3 RXSC200A3 RXSW200A3 111 17.2 (437.9) 17.2 (437.9) 26.8 (679.4) 17.2 (437.9) 26.8 (679.4) Helght- In (mm) 112 20.0 (50B.0) 20.0 (508.0) 30.0 (672.0) 20.0 (508.0) 30.0 (672.0) Width - in (mm) WI 12.5 (317.5) 12.5 (317.5) 10.5 (266.7) 12.5 (317.5) 10.5 (266.7) W2 14.6 (370.8) 14.6 (370.8) 13.5 (342.9) 14.6 (370.8) 13.5 (342.9) Depth - In (mm) 7.1 (180.1) 7.1 (180.1) 6.3 (160.1) 7.1 (180.1) 6.3 (160.1) Weight- Ibs (kg) 20.0 (9.1) 22.5 (10.2) 39.0 (17.7) 20.0 (9.1) 39.0 (17.7) G E N E RAC® Generac Power Systems, Inc. - S45 W29290 HWY. 59, Waukesha, WI 53189 - generac.com ----�-7 G2020 Generao Power Systems, ft. Pll fights reserved. All speolflestlon m 3W1octtochan9ewMoutnouu. PM No. 10000013459 Pave 0& 402U