Loading...
HomeMy WebLinkAboutENERGY CALCS & MANUAL J - 14163 ISLA FLORESFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR PermitOffice: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type> 1432.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1783.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(151.4 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 195 a. U-Factor. Sgl, U=1.02 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 a U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.285 a. Electric Heat Pump 34.8 HSPF:8.50 9. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1753.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 HJ PASS Total Baseline Loads: 50.69 hereby certify that the plans and specifications covered by Review of the plans and SIA�� this calculation are in compliance with the Florida Energy specifications covered by this�S' pF�kl>E __ ; O Code. calculation indicates compliance with the Florida Energy Code. 511 O PREPARED BY:5* Before construction is completed DATE: 1-12-2021 this building will be inspected for compliance with Section 553.908 ' ¢ I hereby certify that this building, as designed, is i mpliance Florida Statutes. with the Florida Energy Cod g.�' 0 WE OWNER/ G N BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factorysealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREATR 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL _ 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 its — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 It 0 63 ft- _- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft- _ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft` _ 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 It 0 36 IF _ 0 1 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 it 0 180 it- _ 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft2 -_ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 _- 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 _ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emift Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block- Int InSMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0 2 SW=>NE Exterior Concrete Block- Int InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 NW=>SE Exterior Concrete Block- Int InsMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below -4 NE=>SW Exterior Concrete Block - Int InsWASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 -5 NE=>SW Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 -6 NE=>SW Exterior Concrete Block - Int InsfiIEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 7 SW=>NE Exterior Concrete Block - Int InsGIINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 S NW=>SE Exterior Concrete Block- Int InsGIINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.3 0 9 SW=>NE Exterior Concrete Block - Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 10 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.3 0 _ 11 SE=>NW Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 12 SW=>NE Exterior Concrete Block- Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _ 13 NE=>SW Exterior Concrete Block - Int InsENEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 14 SW=>NE Exterior Concrete Block - Int InsBEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 15 N=>S Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7 ft- WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang # Orm ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft2 1 8 0 in 1 It 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft2 1 It 0 in 1 It 4 in None None 5 NWaSE 8 Metal Low-E Single Yes 1.11 027 Y 40.0 ft2 8 It 0 in 1 It 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 It 0 in 1 It 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS J — Supply— — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft' Attic 55 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans: Cooling Jan Feb Feb Vent ng Jan Mar Mar r Apr € May May 9 Sep Dec l J [ ] Jun Jul Aug OctX Nov Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 fN 0 ft 0.3 MASTER BEDROO Default(81bs/sq.fL ft' ft 0.3 WIC Default(81bs/sq.fL ft' ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft= it 0.3 M. BATH Default(8 lbs/sq.ft. ft' It 0.3 LAUDRY Default(8 lbs/sq.ft. ft' ft 0.3 BEDROOM 2 Defaul48 lbs/sq.ft. ft' ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft. ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 HALL Default(8 lbs/sq.fL ft' it 0.3 FOYER Default(8 lbs/s.ft. ft' it 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: Design Location: FL, Fort PierceX COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit y aped the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. crier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids betwmn fire sprinkler cover plates and walk or -cefli ings— anl addiuen, nlspeuuuu ul iuy wens snarl oe in acwrdanC Wlm me pmvlslons of IlA:4uu. 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= fP 4. Number of Bedrooms 3 d. WA R= ft2 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area (f') 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor Sgl, U=1.02 11 t35 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 195 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft- SHGC: SHGC=0.27 13. Cooling systems kBtuRv Efficiency c. U-Factor: WA ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor. N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15. Hot water systems a. U-FactogAVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): WA EF: 0.97 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 Credits (Performance method) None b. WA R= ft= c. WA R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: te: Address of New Home: ;ity/FL Zip: ; .3y9 t 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12I2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsoftm Project Summary Job: . Entire House BY. QUICK CALCS, INC. 317 ST. LUCIE LN.. Fr. PIERCE, FL 34946 Plune: 772-466-6799 Fax T 2-4666796 Email: QUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT THE W INDSOR, FT. PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TO 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Central vent (0 cfm) 0 Btuh Btuh Duds Central vent (0 cfm) 9337 0 Btuh Btuh none e) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 27734 Btuh Use manufacturer's data n Infiltration Rate/swing ltiplier Equipment load 0.95 senmusible 24470 Btuh Method Simplified Construction quality Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2495 Btuh Duds 2546 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area(i12) coolingg (none) 1753 1753 Equipment latent load 5041 Btuh Volume (fF) 16478 16478 Airchangesthour 0.38 0.20 Equipment Total Load (Sen+Lat) 29511 Btuh Equiv.AVF (dm) 104 55 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536KO30 AHRI ref 7914585 Efficiency Heatinginput Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 36 OF 8.5 HSPF 34600 Btuh @47-F ecfm 1160 0.042 cfm/Btuh 0 in H2O Backup: Input=7 kW, Output=23009 Btuh, 100AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latentcooling 10440 Btuh Total cooling 34800 Btuh Actual air low 1160 cfm Airflowfador 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. ACM wrigFfLsofY 2021-Jao-1213:18:18 RigkTHE WINDSO a1 Calc9 19.021 RSU081 o Page 1 ...DoamekslWrighL=ofl HVAC\WYNNE-iHE WINDSORnn CaIc=M18 Frorrt Doorhms:N wrightsoft, Right4g) Worksheet Job.' Entire House Date: By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FstreHoum BEDROOM 2 E)yowd wall 207E It 41.0 t 3 Room height 9.4 It d 9.4 It heatlmol 4 Room dimensons 14D x 20.0 it 5 Rcom area 1753D 1F 280.0 fF Ty Conshcbon U-value or HTM Area (IF)Load Am (fF) Load number (BbJW'g (BWhgn m perimeter (e) (BWh) or perimeter (t) (BWh) Heat Cool Gros MpS Heat Cool Gros NIPS Heat Cool 6 13AAocs 0.143 n 4.00 ZSS 649 5% 2386 1517 66 66 263 167 t—G 1A-clom 1270 n 3556 34.77 15 0 533 522 0 0 0 0 I--G 4A5-20m 0770 n 21.56 1931 38 0 815 730 0 0 0. 0 w 13A-4= 0.143 m 4D0 255 27 27 106 68 0 0 0 0 11 W 13A4= 0.143 a 4D0 255 141 100 400 255 0 0 0 0 !—G 1A,c1w 12M a 3556 97.06 20 1 711 1741 0 0 - 0 0 11D0 0390 a 1092 1131 21 21 229 238 0 0 0- 0 W 13A4as 0.143 s! 4110 255 27 27 106 68 0 0 0 0 VN - i—G -1aA4ocs - 0.143 a 4D0 255 536 530 2121 1349 188 188 753 479 1P:c1om 12M s 3556 34.77 6 6 213 209 0- 0 0. 0 13AAM 0.143 w 4.00 255 320 255 1022 649 132 108 432 275 1A-clan 1270 w 35M 5453 12 1 415 636 12 1 415 636 1Aclom 1270 w 3556 5453 12 1 427 654 12 1 427 654 4A5-20m 0.770 w 2156 45.63 41 2 880 1862 0 0 0 0 p 12C-0sx OD97 2.55 128 254 254 647 326 0 0 0 0 C 16A30md OD32 - 0.90 232 1753 1753 1571 4067 280 280 251 650 F 22A-tpl 0989 - 27.69 0.00 1753 208 5748 0 280- 41 1135 - 0 6 c)AEDexausim 397 488 Envelope bs(9ain 18331 15285 3576 3349 12 a) hdtlfration 3211 905 729 205 b) Roornvenlilation 0 0 0 0 13 Intemal gains: O=pan6@ 230 1 230 0 0 Appliance^dofher 0 0 Subtml(Iines6W13) 21542 16420 4405 3554 LessevLmalload 0 0 0 0 Lesllarsfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 26191 19337 3554 15 DUGloads 29% 57% 6191 9337 29% 57% 12fi6 1266 2021 2021 Total roan bad 1 27734 25757 5671 5575 Air required (dm) 1160 1160 237 251 Calculations approved WACCAto meet all requirements of Manual J 8th Ed fir. rl+ «v.+nr�4xe RiE-THE INDS rsa1201919D21 R FW D 01 2027-Jan7273:t8:18 _.Doamer6\Wrigt�ft HUAQWYNf�-THE WINDSORnp CaIc=M18 FroNDoartdces N Page F� wrightsoW Right-M Worksheet Job.' Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE. FL 34946 Phone: 772-466-6799 Faz 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 Expossdwall 0 it 9.0 ft 3 Room height 9.4 ft heaV=1 9A ft heaVcool 4 Room dimensions 7.0 x 9.0 it 7.0 x 9.0 It 5 Room area 63.0 iF 63.0 T Ty Conssumon U-value Or HTM Area Load s (� Load number (BuhXF--°F) (Btilh48) or perimeter (ft) (Bluh) or perimeter (ft) (Sluh) Heat Cool Gross NIPS Heat Cool Gross NiPS Heat Cool 6 vl/ 13A4o s 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 19,31 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A4= 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 tAclom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4as 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1-3 13A4as 0.143 s 4.00 2.55 0 0 0 0 85 85 339 215 1Ac1cm 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A4ors 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1an 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 G to-clom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 63 63 56 146 63 63 56 146 F 22A-tpl 0.989 27.69 0.00 63 0 0 0 63 9 249 - 0 6 c) AED excursion 1 -10 _2g Envelope loss/gain I1 56 136 644 334 12 a) Infiltration 0 0 160 45 b) Room ventilation 0 0 0 0 13 Intemalgains: Ocupan4@ 230 0 0 0 0 ApplianczJolher 0 0 Subtotal (fines6to13), 56 136 804 378 Lessexiemalload 0 0 0 0 Lesstransterbulio 0 0 0 0 Rubtotabufion 0 0 0 0 14 Subtotal 56 136 8 379 15 Duo:loads 29% 57°/, 16 77 29% 57% 231 31 216 216 Total room load 73 214 1036 595 Air required(dm) 3 10 43 27 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed !t' 2021- ,1213:18:18 �A MgMSUtedt Uriwml201919.021 RSU08101 ...D c rlslW69K ftWAC\WYNNE-THEWINDSORrtp Calc=M18 Frorrtpoorfares N Page 2 wrw tsoft° Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 SL LUCE LN..Fr.. PIERQE, FL 34946 Ptone: 7724W-6799 Fax 772466- 7% EMU: QUICKrALCS@AOL.COM 1 Room name MBATH 10TCHEN wall 8.0 it 8.0 1t 3 Room height 9A It heavmol 9.4 It heal/000l 4 Room dimensions 7.0 x 8D It 1D x 172D It 5 Room area 56D 1F 172.0 R Ty Construction U- lue Or HTM Area Load number (BIuh4F°F) (BWMF) or perim� (ft) (Bfi1h) orperimeter (1) (BWh) Heat Cad Gros N/PS Heat Cod Crass NIPS Heat Cool 6 13A o s 0.143 n 4D0 2.55 0 0 0 0 0 0 0 0 1A-d= 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21J% 1931 0 0 0 0 0 0 0. 0 W 13A4ors 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 11 yl 13AAocs 0.143 a 4A0 2.55 0 0 0 0 0 0 0 0 I�—G 1Actom 12M a 3556 87.06 0 0 0 0 0 0 0 0 D 11Do 0390 a 1022 1131 0 0 0 0 0 0 0 0 w 13A4os 0.143 se 4D0 255 0 0 0 0 0 0 0 0 t13A-4= 0.143 s 4D0 255 75 69 277 176 0 0 0 - 0 1Aclom 1270 s 3556 34.77 6 6 213 209 0 0 0. 0 —G 13A4ors 0.143 w 4.00 255 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 54.53 0 0 0 0 0 0 0 0 1Aclom I w 3556 54M 0 0 0 0 0 0 0 0 4P5-2om 0.770 w 2156 45M 0 0 0 0 0 0 0 0 P 12C0sw 0.091 - 255 128 0 0 0 0 75 75 192 95 C 16A30md 0.032 - 0.90 232 56 56 50 130 172 172 154 399 F 22A-tpl 0.989 - 27.69 0.00 56 8 222 0 172 8 222 -- 0 6 c)AEDecwsion -38 -34 Ernelopelosslgain 1762 477 567 462 12 a) Infilbfion 142 40 0 0 b) Roomaenfilafion 0 0 0 0 13 Intend gains O=pants@ 230 0 0 0 1 0 Appriance5/oiher 0 0 Subhttal(lines8fi313) 904 517 567 462 Leswmamaiload 0 0 0 0 Lestransfer 0 0 0 0 Redistribution I 0 0 0 0 14 Subtotal 904 517 566 15 DuCloads 29% 57% 260 294 29% 57% 163 263 Trial room bad 1164 811 730 725 Air required(ctm) 49 37 31 33 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. n +1+ w��assr�sv�x Ri9ttSute®llriversa1201919.021 RSW8101 2021Jaot213:16:18 ...DoamertAWrigNSAHUAMWYNNE-THEWINDSORnp Calc=MI8 Frost Coorface : N Page F� wrightsow Right-J® Worksheet Job: Entire House By. By. QUICK CALCS, INC. $17 ST. LUCIE LN.,Fr... PIERCE, FL34946 Phone: 772-066E799 Fax772466-6796 E.il:QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM2 2 E�wall 5.0 It 42B It 3 Room height 9.4 It heat/occl 9.4 ft heatlmol 4 Room dimensions 9D x 5.0 It 1.0 x 204.0 ft 5 Roomaree 45.0 IF 204.0 fl- Ty I Construction U-value Or HTM Area (ft) Load Area (IF)Load number (BtrhffF-'n (BWW) or perimeter (ft) (BWh) or perimeter (ft) stuh) Heat I Cool Gross N/P/S Heat Cool Gras NIPS Heat Cool 6 tr}I 13AAM 0.143 n 4,00 2.55 41 47 188 120 132 132 527 335 1Ac1om 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A6-2om 0.770 n 2156 1931 0 0 0 0 0 0 0 0 W 13A-4= 0.143 ne 4.00 2.55 0 0 0 0 27 27 106 68 11 V 13A-4= 0.143 a 4.00 2.55 0 0 0 0 85 65 259 164 I-G �D 1Aa1an 1270 a 3556 87.06 0 0 0 0 20 1 711 1741 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-4= 0.143 se 4.00 2.55 0 0 0 0 27 27 106 68 Vd 13AAM 0.143 s 4.00 2.55 0 0 0 0 132 132 527 335 -G tAtlom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-0ors 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1A-clom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 - 2,55 128 0 0 0 0 0 0 0 0 C 16A�Omd 0.032 - 0.90 2.32 45 45 40 104 204 204 183 473 F 22A-tpl 0989 27.69 0.00 45 5 138 0 204 43 1179 0 6 c)AEDe rsan -17 -99 EnvelopeloWgain 367 207 3599 3085 12 a) Infiltafion 89 25 758 214 b) Room ventilation 0 0 0 0 13 Intemalgairw O=panls@ 230 0 0 0 0 Applianoes�other 0 0 Subtotal (lines 6 to 13) 456 232 4357 3299 Lesextemal load 0 0 0 0 Las transfer 0 0 0 0 Rectbibuton 0 0 0 0 14 Sublotal 456 232 4357 3299 15 Ductloads 29% 57% 131 132 29% 57% 1252 1876 Total room load 587 364 5609 5175 Air required(cfm) 25 16 235 233 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed _ -'}t wri9i+iso2t" 2021Ja 1213:18:18 Right -SILL Uriversai 201919.021 RSUC8101 .4 A ...Doss rts\Wnghsoft HUAQWYNNE-THEWINDSOR.nn Calc=M18 Front Doorfaces: N Page 4 wrightsofr Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST.. LUCIE LN.. FL PIERCE, FL 34946 Plum: 772-466-6799 Fax 772-466-6796 Emil: QUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 EVosd well I 18.0 It 130 It 3 Room height 9.4 ft heaV000l 9.4 It heaVcool 4 Room dimension@ 1.0 x 92A it 7.0 x 6.0 It 5 Room area 92.0 W 42A1 F Ty Construction LLelue Or FITM Area ft' Load � ( Load numbs (BWha'-°Fj (BWIiMn ft or perimeter () (BWh) or perimeter �r (ft) (BhOt) Heat Cool Gross N/P/8 Heat Cool Goss N1P/3 Heat Cod 6 V 13A4ocs 0.143 n 4A0 2b5 0 0 0 0 0 0 0 0 1Ac1an 127C n $5.56 34.77 0 0 0 0 0 0 0 0 `�1C' 4A5-2om 0.770 n 21M 19.31 0 0 0 0 0 0 0 0 W 13A4o s 0.143 ne 4A0 255 0 0 0 0 0 0 0 0 11 yl 13PAors 0.143 a 4.00 2.55 56 35 142 90 0 0 0 0 1Aclom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 I�----DG 11D0 0390 a 10.92 1131 21 21 229 238 0 0 0 0 W 13AAo s 0.143 s 4A0 2S5 0 0 0 0 0 0 0 0 W 13A-flocs 0.143 s 4A0 255 0 0 0 0 56 56 2� 144 t—G 1Actan 12M a 3556 34.77 0 0 0 0 0 0 0- 0 13AAots 0.143 w 4.00 255 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 5453 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 54M 0 0 0 0 0 0 0 0 4PS2om 0.770 w 2156 45M 0 0 0 0 0 0 0 0 P 12C-0av O.W - 255 128 113 113 287 w 66 66 168 84 C 16A-30md (1032 - 090 232 92 92 82 213 42 42 38 97 F 22A4A (1989 - 2759 0.00 92 18 498 0 42 13 360 0 6 c)Amexcvrsfon 4S -24 Erwalopelos/gain 1239 637 791 371 12 a) Infiltration 107 30 107 30 b) Roomeentlation 0 0 0 0 13 internal gains O=pants@ 230 0 0 0 0 Applianoes(other 01 0 Subb>gl(liines64t13) 667 898 331 Leselamalload 0 0 0 Lestrasler 0 0 0 Redistribution 0 0 0 14 Subloal 667 858 wl 15 Du[tloads 29%f57-%L387 379 29% 57% 258 188 188T��^� Air required(dm) 1047 1155 520 72 47 48 23 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed lax - wrY9M>tsoft- 2021-Jan1213:18:18 Rigt-THEW IK)S rea W CaI9.027 RSU08101 ...DoameroiWngtCroflHVAgWYNNE-THE WINO60Rnp CaIc=MIB Fror613oorfaces N Pages wrightsoft RighW@ Worksheet '°"° Entire House Date: QUICK CALCS, INC. By. 317 ST LUCIE LN., FT. PIERCE, FL 34946 PFone: 772-466-6799 Faz 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name GREAT/DINING Rcom7 2 E a vall 50.0 it 13.0 ft 3 Room height 9.4 ft heal/000l 9.4 t heaV=l 4 Room d,nrv.ns to x 5137.0 ft 13.0 x 13.0 It 5 Room area 567.0 fl' 169.0 ft' Ty Corstnudw U-value Or HTM Area (ftl Load Area (ftl Load number (Buh/ -q (BuhW) or panmeter (it) (Buh) or perimeter (it) (Suh) Heat I Cool Gros N/P/3 Heat Cool Gross N/P/S Heat Cool 6 Vi/ 13A-4ocs 0.143 n 4.001 2S5 282 244 978 622 122 107 429 273 1Aclom 12M n 3556 34.77 0 0 0 0 15 0 533 522 L--GG 4A5.2om 0.770 n 21.56 19.31 38 0 815 730 0 0 0 0 W 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 Y)/ 13A4=0.143 a 4.00 2S5 0 0 0 0 0 0 0 0 tAclom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4= 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 Y)/ 13A4=0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 t-G 1Ac1om 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A4= 0.143 w 4.0D 2.55 188 147 589 375 0 0 0 0 1Ac1cm 1270 w 3556 54.53 0 0 0 0 0 0 0 0 1k1om 1270 w 35M 54.53 0 0 0 0 0 0 0 0 4A62om 0.770 w 2156 46.63 41 2 880 1862 0 0 0 0 P 12C-OW 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 567 567 508 1315 169 169 151 392 F 22A-yl U& - 27.69 0.D0 567 50 1385 0 169 13 360 0 6 c)AED e=rsim 307 -100 Envelope loss(gain 5154 5210 474 1086 12 a) Infiltration 889 251 231 65 b) Rocmvenfilation 0 0 0 0 13 Internal gains: Omrpants@ 230 0 0 1 ApplianceJother 230 0 0 Subtotal(lines6to13) 6043 5461 1705 1381 I I Les e)dgmal load 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 0 15 Subu61 6043 5461 1 1 381 1 DUCloads 29% 57% 1737 3105 29% 57°/, 490 490 785 TAoir6rel qmd o(cafdm) 7780 8566 2195 219687 66 92 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed .4 A wrighisoTC^ Pog2021-Jan-1213:18:18 kSuteC�ilUnversa1201919.021 RSU08101 ...Doe re;1W691fso8HVACIWYNNE-THEWINDSOR.np Caic=MJ8 Front Caorlaces: N Page -�- wrightsoft' Duct System Summary tea.' Entire House BY QUICK CALCS, INC. 317 ST. LUCIE LN.. Fr. PIERCE. FL 34946 P1pre: 772466-6799 Fax 712-466-6796 Emil: QUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT THE W INDSOR, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000/0.000 in H2O 0 in/100ft 1160 dim 0 ft Supply Branch Detail Table Cooling 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 1160 clim Name Design (Btuh) Htg (dm) CIg (dm) Design FR Diam (in) H x W (n) Duct Mat Actual Ln (it) Ftg.Egv Ln (ft) Trunk BATH h 364 25 16 0 0 OxO ShMt 0 0 BEDROOM C 2788 119 126 0 0 Ox 0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 OxO ShMt 0 0 BEDROOMA C 2788 119 126 0 0 Ox0 ShMt 0 0 ENTRY h 1047 72 47 0 0 0x 0 ShMt 0 0 GREAVDINING C 2855 108 129 0 0 Ox0 ShMt 0 0 GREAT/DINING-A C 2855 108 129 0 0 OxO ShMlt 0 0 GREATAMNWG-B C 2855 108 129 0 0 Ox0 ShMt 0 0 KITCHEN C 725 31 33 0 0 OxO ShMt 0 0 LAUNDRY h 520 48 23 0 0 0x0 ShMt 0 0 M BATH h 811 49 37 0 0 Ox0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 Ox0 ShMt 0 0 R n7 C 2167 92 98 0 0 OxO ShMt 0 0 WIC c 214 3 10 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Name Grille Sze (in) Hg (dm) Clg I (cim) I TEL (ft) Design FR I Meloc (fpm) I Diam (n) H x W (in) I Stud/Joist Opening (in) Dud Mad Trunk rb1 Ox0 1160 1160 0 1 0 0 0 Ox 0 ShMt Wright Ri9ltSUIB@UnVersa1201919.021 RSU08101 2021-,1 -1213:18:19 ...Dc rtAWrgtmft FNAC\WYNNE-THEWIKMORnp Calc=MIS FrOMDWrfares N Page