Loading...
HomeMy WebLinkAboutAPPROVED, 641 Glenview AveJoseph P. McCarty, Architect, Inc. 900 East Osceola Street Stuart, Florida, 34994 772-287-6735 fax: 772-287-4618 ➢PR Registration Number 9639 June 23, 2021 St Lucie County Planning and Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 RE: 641 Glenview Avenue, Fort Pierce Digitally signed Joe by Joe McCarty Date: McCarty 2021.06.23 09:22:40-04'00' Work consists of re -roofing existing structure with 26 gauge 5V galvalume roofing Wind Certification — Design Criteria These plans are designed to the following standards Florida Building Code 7th Edition 2020 2017 NEC Wind Speed —165 MPH V ult Exposure "B" Structure is enclosed Internal Pressure Coefficient +/- .18 Building Category II Importance Factor 1.0 Design Pressures —160 Vult — Exposure "B" mean roof height 30' Note sheathing to be 19/32" CDX plywood with 2 %" x 0.131, or 3" x 0.120 ring shank nails 4" on center on edges and in field Gable Roof > 20 to 27 degrees 1.2e 10 +20.6 -39. 1.2e 20 +17.8 -39.3 1.2e 50 +14.0 -33.5 1.2e 100 +11.2 -28.8 2n,2r,3e 10 +20.6 -62.8 2n,2r,3e 20 +17.8 -55.0 2n,2r,3e 50 +14.0 -44.7 2n,2r,3e 100 +11.2 -37.0 3r 10 +20.6 -74.5 3r 20 +17.8 -62.8 3r 50 +14.0 -46.4 3r 100 +11.2 -46.4 Five V Crimp Roof Metal Alliance Inc. FL 31652-R1 Design pressure required Design pressure provided Underlayment -74.5 -117.75 (fasteners @ 16" on center)