HomeMy WebLinkAboutAPPROVED, 85482-LAY-SLD6
12
1'-4"4316"358"1'-4"358"G
G
G
G
G
PPPPPPG
23'0-7/8"11'7-1/8"10'19'7-5/8"3'3"
18'10"7'12'2"4'12'3-1/2"7'0-1/2"18'8"15'0-3/8"19'7-5/8"2'1'10-3/4"
2'
2'
2'
2'
2'
2'
2'
2'
15'6"4'38'34'8"15'0-3/8"1'8-7/8"1'2-3/16"1'2'2'2'2'2'2'2'2'2'10'0-1/2"2'
2'
2'
2'
2'
2'
2'
2'
2'
2'2'2'2'2'2'11'3-5/8"2'
2'
1'10'10'48'8"8'10"15'14'2"
FLUSH BEAM BY OTHERS
BOTTOM @ 8' 8"
8' 8" FLAT CLG
8' 8" FLAT CLG
8' 8" FLAT CLG
AC CHASE
AC CHASEAHU
AC CHASE
OPEN TO ABOVE/ STAIRWELL1 PLY 2X12
BY BLDR. 2 PLY 2X12 BYBLDR. BOT @ 8'-8"HBB18'4"FL02FL02FL02FL02FL02FL02FL02FL02FL02FL02GEFL02FL02FL03
FL03
FL03
FL03
FL03
FL03
FL03
FL03
FL03
FL03GE
FL05
FL05
FL05
FL05
FL05
FL05
FL07
FL07
FL07
FL07
FL07
FL07GE
FL07
B02
B03 FL06EFL06FL06FL06FL06FL06FL06FG01FG02L01
L02
L03
J1L J1LJ1LJ1L
J3LJ3LJ3LJ3LJ5LJ5LJ5LJ5LHJ5LHJ5L
12'10-1/2"18'7"7'2'2'2'2'2'
7'2'2'2'2'2'2'34'8"12'2"7'18'10"
38'
3/12 SLOPED CLG 3/12 SLOPED CLGAHU
BEARING @ 8' 8"
BEARING @ 18' 3/4"
J1
J1J1
J1J1
J3J3
J3
J3J3
J5J5
J5
J5J5
J7
J7
J7
J7
J7
J7
J7
J7
J7
J7
J7
J7
J7
J7
J7
J7
J7
J1B J1BJ3B J3BJ5B J5BJ7B
J7B
J7B
J7B
J7B
J7B
J7BHJ7BHJ7HJ7A01A02A03A04A04A05A05A06A06A07A08A09A10
J1J3J5HJ75'2'2'It is understood that above
conditions have been reviewed &
are acceptable for the fabrication
at trusses, elevations,pitches,
overhangs, fascias,ceiling
elevations/pitches, bearing
conditions & all detail pertaining
to this truss placement plan. No
back charges will be accepted
without previous written approval
from an A-1 Roof Trusses
representative.
REPRESENTS THE LEFT SIDE
OF EACH TRUSS DRAWING
*10PSF Non-concurrent live load applied to BC( NOTE: REFER TO SIMPSON CONNECTOR
CATALOG FOR INSTALLATION DETAILS )
20
10
0
7
37
1.25
40
10
0
5
55
1.00
ASCE 7-16
160 C
Residential - CAT II
Enclosed
FBC 7th Ed. 2020 Res.
TPI 2014
RENAR HOMES
4/21/21
AA
85482
MODEL: BERKSHIRE 2177 / ELEV. B /GAR L
ST LUCIE
FORT PIERCE
COVERED LANAI
MORNINGSIDE
- -
NTS
- --/--/---- -
-
- --/--/---- -
-
- --/--/---- -
-
- --/--/---- -
-
- --/--/---- -
-
- --/--/---- -
-
- --/--/---- -
-
WIND LOADFLOORROOF
LIVE LOAD
DEAD LOAD
LIVE LOAD
DEAD LOAD
TOTAL LOAD
DURATION FACTORTOPCHORDBOTTOMCHORD
REV DATE BY REMARKS
FOR BRACING & ERECTION DETAILS REFER TO BCSI-03
AND/OR ENGINEER OF RECORD.
LOADING
* NOTE: THIS TRUSS PLACEMENT DIAGRAM IS TO SHOW
TRUSS I.D. AND TRUSS LOCATION ONLY. THE BUILDING
DESIGNER IS RESPONSIBLE FOR THE STRUCTURAL
STABILITY OF THE ENTIRE STRUCTURE. REFER TO THE
INDIVIDUAL TRUSS ENGINEERING DRAWINGS FOR
GRAVITY AND UPLIFT LOADS.
* NOTE: ALL CEILING DROPS BELOW BEAM ARE
BY BUILDER. (UNLESS NOTED OTHERWISE)
* NOTE: ALL TRUSS TO WALL AND/OR TRUSS TO
LEDGER CONNECTIONS BY BUILDER.
(UNLESS NOTED OTHERWISE)
PLAN DATE
CUSTOMER
JOB NAME
OPTION(S)
COMMUNITY
/ LOT #
CITY
COUNTY
REVIEWED BY
REVISE AND RESUBMIT
APPROVED AS NOTED
APPROVED
REJECTED
DATE
BLDG.
TYPE
JOB #
DATE
BLDG.
#
MASTER
DRAWN SCALE
STRUCT: --/--/------/--/----ARCH:TRUSS PLACEMENT DIAGRAM NOTE: The design assumptions, loading conditions, load paths, suitability and use of structural building components (e.g. Trusses, etc.) for any Building is the responsibility of the Owner, the Owner's authorized agent or the Building Designer (hereinafter BD), in the context of the IRC, the IBC, the local building code and ANSI/TPI 1 (TPI 1). A-1 Roof Trusses and the truss designengineer shall be permitted to rely upon the accuracy and completeness of project contract and construction documents (also referred to at times as ”Structural Engineering Documents”), including any specifications that have been furnished to A-1 Roof Trusses in writing by the BD for the Building. The Truss Design Drawing(s) [TDD(s)] and Truss Placement Diagram (TPD) referenced have been prepared based onthe construction documents provided by the BD indicating the nature and character of the work. The design criteria therein have been transferred to the truss design engineer by A-1 Roof Trusses. All TDDs (also referred to at times as “Structural Delegated Engineering Documents”) are specialty structural component designs and may be part of the project's deferred or phased submittals. As the Truss DesignEngineer, the seal provided here and on any TDD represents an acceptance of professional engineering responsibility for the design of the single Truss depicted on the TDD only. Where required by the project contract or construction documents, including any specifications, a TPD identifying the location of each truss, as assumed by A1 Roof Trusses based on its review of the project contract documents, isprovided. When the TPD (i.e. structural submittals or shop drawings) serves only as a guide for truss installation, it does not require the seal of any RDP. The truss design engineer seal on any TPD certifies that the individual truss designs are based on the positioning shown and that the dimensions and loads shown on the referenced drawings match that positioning, and designates specifically that the TPD has beencreated in compliance with the latest version of TPI-1. The Building Designer is responsible for and shall coordinate and review the TDDs and this TPD for compatibility with their written engineering requirements. Structural submittals (i.e. shop drawings) shall be reviewed by the BD for compatibility with the design of the building or structure, including submittal documents prepared by others, deferred submittaldocuments and phased submittal documents. This review shall include a notation indicating that the reviewed documents have been found to be in general conformance with the design of the building (or to make specific corrections noted and to return for review). In the absence of this notation A-1 Roof Trusses will provide its Buyer with the design assumptions used, per the construction documents, to designindividual structural building components and provide any TPDs per TPI-1. The Truss Design Engineer is NOT responsible for the following including but not limited to: Transfer of lateral load from the roof to the shear walls, Connection of trusses to the bearing support, Design of the bearing supports, Temporary and permanent building stability bracing required in the roof and/or floor system, Transfer of verticalloads down to the foundation, Design of the foundation and soil, Analysis of the roof and/or floor diaphragms of the building, Connection of roof and/or floor diaphragm to the truss, Specifying the loads used in the design of the trusses and so forth. Neither A1 Roof Trusses nor truss design engineer is the Building Designer or Truss System Designer/Engineer for any building. If any engineering services, outside thescope of work of the truss design engineer, are required by the Owner, the Owner's authorized agent or the BD, please call 772-409-1010 for assistance.R
U
T
SMUS26
THJA26
THA422
HHUS46 Q
HHUS26-2
HUS28
HUS26
LUS26
LUS24
M
L
K
J
H
E
D
C
B
A
* NOTE: LSTA STRAP
INDICATED TO BE USED IN
CONCORDANCE WITH
CORNERSET DETAIL.
X
BEAM BY BUILDERBBB
LUS46
LSTA12
LSTA12
P
LSTA12
G
Zb
Zt
Z
HBB
@ BC
@ TC
HANGER BY BUILDER
@ TC & BC
HHUS28-2 VNF
- - -
- - -
LUS44
- - -
- - -
- - -
- - -
- - -
- - -
- - -
Typical Cornerset Specifications
7'-0" MAXAttach KingJack w/(3)
0.131"Ø ToeNails @
TC & BC
Attach End Jacks
w/ (4) 0.131"Ø ToeNails @ TC
& (3) 0.131"Ø ToeNails @ BC
Attach Corner Jacks w/(2)
0.131"Ø ToeNails @ TC & BC
(typ.)
1'1-1/16"2'0"2'0"Typ. Corner Jack Placement 1' 10-15/16"Created:4/21/2021LOT 36
B