Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Revision
OFFICE USE ONLY:DATE FILED: 40 --I3 PERMIT#/;20c;� �y-020 / REVISION FEE: % 0 RECEIPT# C/ PLANNING&DEVELOP%MN ENV C . O BUILDING&CODE 1 2300 VIRGINIA.A r : FORT PIERCE,%344(* (772)462- 3 APPLICATION FOR BUII,I) T PROJECT INFbRl f 1. LOCATION/SITE ADDRESS: 1( 0t 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: ,,,�J les�'.PA — �—IOUc- 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: ST.LUCIE COUNTY CERT.#: BUSINESS NAME: .rt ,- t.L L QUALIFIERS NAME: o�n ADDRESS: Au ids N. +* lot _ CITY: nuieioiO STATE: Z11P: 4 5 PHONE(DAYT 1 E): bo-?-) q 9 -001 FAX: 4. OWNER/BUILDER INFORMATION: 1 NAME: 1`(1�Vk �k- �- 6u 7&,I n(- ADDRESS: t078l 0 PC'n f:-k- -0L(.L10 CITY: Tt Ast N J-2-ju,.h STATE: ZIP: PHONE: FAX: 5. ARCHITFC.T/ENGINEER INFORMATION: NAME: _laa—oh ML.C�rf./ V'lt. ADDRESS: 206 S_ Q*2 On_ t 5-h-t > - CITY: S Vuc,r- - STATE: ZIP: PHONE(DAYTIME): FAX: SLCCC:9/23/09 Revised 04/26/2010 1 RECEIVED DEC 172013 a°�- oaC ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the EnergyPerformance Index, the more efficient the home. 10701 S. OCEAN DRIVE, JENSEN BEACH, FL, 34957- 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 2257.40 ft2 b. Interior Frame-Wood,Interior R=13.0 442.50 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=19.0 1138.00 ft2 6. Conditioned floor area(ft2) 1940 b.Under Attic(Vented) R=1.0 76.00 ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.60 501.49 ft2 11.Ducts R ft2 SHGC: SHGC=0.27 a.Sup:Attic,Ret:STRS/HALL,AH:Garage 6 774 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ft2 a. Central Unit 46.0 SEER:25.00 SHGC: d. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2 9gg ft. a.Electric Heat Pump 46.0 HSPF:8.20 Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14. Hot water systems a.Crawls ace 2 a.Electric Cap:40 gallons P R=19.0 818.00 ft2 b.Raised Floor R=0.0 337.00 ft2 EF:0.92 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building qHt ST Construction through the above energy saving features which will be installed (or exceeded) yoF 4 in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code cornt fea Builder Signature: Date: r'1 Address of New Home: + SO( City/FL Zip F" *rl� ������ OD wE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient -imortgage (EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 639-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software RECEIVED DEC 17= moa- OR01 FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method LDesign me: MIKE 8 SUSAN RICHARDS Builder Name: 10701 S.OCEAN DRIVE Permit Office: ,Zip: JENSEN BEACH ,FL,34957- Permit Number: MIKE 8 SUSAN RICHARDS Jurisdiction: cation: FL,ST_LUCIE_CO_INTL 1. New construction or existing New(From Plans) 9. Wall Types(2699.9 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=5.0 2257.40 ft' b. Interior Frame-Wood, Interior R=13.0 442.50 ft' 3. Number of units,if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d.N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types (1214.0 sgft.) Insulation Area 2 a.Under Attic(Vented) R=19.0 1138.00 ft 6. Conditioned floor area above grade(ft') 1940 b.Under Attic(Vented) R=1.0 76.00 ft' Conditioned floor area below grade(ft') 0 c.N/A R= ft' 11.Ducts R ft' 7. Windows(501.5 sgft.) Description Area a.Sup:Attic,Ret:STRS/HALL,AH:Garage 6 774 a. U-Factor: Dbl,U=0.60 501.49 ft' SHGC: SHGC=0.27 b. U-Factor: N/A ft' 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 46.0 SEER:25.00 c. U-Factor: N/A ft' SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a.Electric Heat Pump 46.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.939 ft. Area Weighted Average SHGC: 0.270 14.Hot water systems 8. Floor Types (1155.0 sgft.) Insulation Area a. Electric Cap:40 gallons a.Crawlspace R=19.0 818.00 ft' b. Conservation features EF:0.920 b.Raised Floor R=0.0 337.00 ft' None c.N/A R= ft' 15.Credits Pstat Glass/Floor Area: 0.258 Total Proposed Modified Loads: 38.80 PASS Total Standard Reference Loads: 50.40 1 hereby certify that the plans and specifications covered by Review of the plans and THE Sr4p this calculation are in compliance with the Florida Energy specifications covered by this vO Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: _ Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 ' ° hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Co46. 0 C�t7 WrO OWNER/AGENT: ' BUILDING OFFICIAL: DATE: � �� DATE: - Compliance requires completion of a Florida Air Barrier and Insula pection Checklist 12/16/2013 1:29 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7 PROJECT Title: MIKE&SUSAN RICHARDS Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1940 Lot# Owner: MIKE&SUSAN RICHARDS Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 10701 S. OCEAN DRIV Permit Office: Cross Ventilation: No County: ST. LUCIE Jurisdiction: Whole House Fan: No City,State,Zip: JENSEN BEACH , Family Type: Single-family FL, 34957- New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST_LUCIE_CO_INTL FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 58 Medium BLOCKS Number Name Area Volume 1 Entire House 1940 18280.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 PDR.ROOM 29 290 No 0 1 Yes Yes Yes 2 HALL 48 480 No 0 1 Yes Yes Yes 3 KITCHEN 201 2010 Yes 2 1 Yes Yes Yes 4 GREAT ROOM 524 5240 No 4 1 Yes Yes Yes 5 MASTER BEDROO 337 3033 No 2 1 1 Yes Yes Yes 6 WIC 128 1152 No 0 1 Yes Yes Yes 7 SINK 36 324 No 0 1 No Yes Yes 8 LIN. 6 54 No 0 1 No Yes Yes 9 LIN 6 50 No 0 1 No Yes Yes 10 TUB 47 423 No 0 1 No Yes Yes 11 TOILET/SHWR 50 450 No 0 1 Yes Yes Yes 12 DEN/BR 121 1089 No 1 1 Yes Yes Yes 13 CLO. 21 189 No 0 1 Yes Yes Yes 14 STRS/HALL 144 1296 No 0 1 Yes Yes Yes 15 W/D 29 261 No 0 1 Yes Yes Yes 16 • BEDROOM 2 129 1161 No 1 1 1 Yes Yes Yes 17 CLO 10 90 No 0 1 Yes Yes Yes 18 . BATH 2 74 688.2 No 0 1 Yes Yes Yes 12/16/2013 1:29 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7 1 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Crawlspace PDR.ROOM 6.8 ft 0 28.7 ft2 19 0 1 0 2 Crawlspace HALL 4 ft 0 48 ft2 19 0 1 0 3 Crawlspace KITCHEN 10.5 ft 0 201.3 ft2 19 0 1 0 4 Crawlspace GREAT ROOM 72 ft 0 524.2 ft2 19 0 1 0 5 Raised Floor MASTER BEDRO ____ ____ 337 ft2 0 0 0 1 6 Crawlspace TUB 1 ft 0 15.8 ft2 19 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1250 ft2 152 ft2 Medium 0.9 No 0.9 No 0 14 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1213 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) KITCHEN 1 1 ft2 0.1 Wood 2 Under Attic(Vented) GREAT ROOM 1 75 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BEDRO 19 337 ft2 0.1 Wood 4 Under Attic(Vented) WIC 19 128 ft2 0.1 Wood 5 Under Attic(Vented) SINK 19 36 ft2 0.1 Wood 6 Under Attic(Vented) LIN. 19 6 ft2 0.1 Wood 7 Under Attic(Vented) LIN 19 6 ft2 0.1 Wood 8 Under Attic(Vented) TUB 19 47 ft2 0.1 Wood 9 Under Attic(Vented) TOILET/SHWR 19 50 ft2 0.1 Wood 10 Under Attic(Vented) DEN/BR 19 121 ft2 0.1 Wood 11 Under Attic(Vented) CLO. 19 21 ft2 0.1 Wood 12 Under Attic(Vented) STRS/HALL 19 144 ft2 0.1 Wood 13 Under Attic(Vented) W/D 19 29 ft2 0.1 Wood 14 Under Attic(Vented) BEDROOM 2 19 129 ft2 0.1 Wood 15 Under Attic(Vented) CLO 19 10 ft2 0.1 Wood 16 Under Attic(Vented) BATH 2 19 74 ft2 0.1 Wood 12/16/20131:29 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 SE Exterior Concrete Block-Int InsWDR.ROOM 5 6 9 10 0 67.5 ft2 0 0 0.8 0 _ 2 SW Interior Frame-Wood PDR.ROOM 13 4 3 10 0 42.5 ft2 0 0.25 0.8 0 _ 3 SE Exterior Concrete Block-Int Insul HALL 5 4 0 10 0 40.0 ft2 0 0 0.8 0 _ ,C NW Interior Frame-Wood HALL 13 7 9 10 0 77.5 ft2 0 0.25 0.8 0 5 NE PDR.RO Interior Frame-Wood HALL 13 8 3 10 0 82.5 ft2 0 0.25 0.8 0 _ 6 NW Exterior Concrete Block-Int InsulKITCHEN 5 10 6 10 0 105.0 ft2 0 0 0.8 0 _ 7 NE PDR.RO Interior Frame-Wood KITCHEN 13 14 6 10 0 145.0 ft2 0 0.25 0.8 0 _ 8 SE PDR.RO Interior Frame-Wood KITCHEN 13 5 3 10 0 52.5 ft2 0 0.25 0.8 0 9 SE Exterior Concrete Block-Int InsCRREAT ROO 5 27 9 10 0 277.5 ft2 0 0 0.8 0 10 W Exterior Concrete Block-Int InsCRREAT ROO 5 33 5 10 0 334.2 ft2 0 0 0.8 0 11 NW Exterior Concrete Block-Int InsCRREAT ROO 5 10 10 10 0 108.3 ft2 0 0 0.8 0 12 NE PDR.RO Interior Frame-Wood GREAT ROO 13 4 3 10 0 42.5 ft2 0 0.25 0.8 0 _13 SE Exterior Concrete Block-Int InsUASTER BE 5 10 0 9 0 90.0 ft2 0 0 0.8 0 _14 S Exterior Concrete Block-Int InsUASTER BE 5 3 11 9 0 35.3 ft2 0 0 0.8 0 15 SW Exterior Concrete Block-Int InsUASTER BE 5 10 0 9 0 90.0 ft2 0 0 0.8 0 _16 W Exterior Concrete Block-Int InsUASTER BE 5 13 8 9 0 123.0 ft2 0 0 0.8 0 _17 W Exterior Concrete Block-Int Insul WIC 5 6 6 9 0 58.5 ft2 0 0 0.8 0 _18 NW Exterior Concrete Block-Int Insul WIC 5 16 11 9 0 152.3 ft2 0 0 0.8 0 _19 NW Exterior Concrete Block-Int InsZDILET/SHW 5 6 11 9 0 62.3 ft2 0 0 0.8 0 _20 NW Exterior Concrete Block-Int Insul DEN/BR 5 10 6 9 0 94.5 ft2 0 0 0.8 0 21 SE Exterior Concrete Block-Int Insul CLO. 5 5 0 9 0 45.0 ft2 0 0 0.8 0 22 SE Exterior Concrete Block-Int InsiSTRS/HALL 5 14 9 9 0 132.8 ft2 0 0 0.8 0 23 SE Exterior Concrete Block-Int Insul W/D 5 6 6 9 0 58.5 ft2 0 0 0.8 0 24 NE Exterior Concrete Block-Int InsBEDROOM 2 5 10 6 9 0 94.5 ft2 0 0 0.8 0 25 SE Exterior Concrete Block-Int InsBEDROOM 2 5 12 3 9 0 110.3 ft2 0 0 0.8 0 26 SE Exterior Concrete Block-Int Insul CLO 5 2 3 9 0 20.3 ft2 0 0 0.8 0 27 NE Exterior Concrete Block-Int Insul BATH 2 5 4 0 9 4 37.3 ft2 0 0 0.8 0 28 NW Exterior Concrete Block-Int Insul BATH 2 5 12 11 9 4 120.6 ft2 0 0 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Wood HALL None .6 3 7 21 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. -7 Wall Overhang v , # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 SE 1 None Low-E Double Yes 0.6 0.27 6.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 2 NW 6 None Low-E Double Yes 0.6 0.27 11.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 3 SE 9 Vinyl Low-E Double Yes 0.6 0.27 30.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 4 W 10 Vinyl Low-E Double Yes 0.6 0.27 71.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 5 W 10 Vinyl Low-E Double Yes 0.6 0.27 26.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 6 W 10 Vinyl Low-E Double Yes 0.6 0.27 25.5 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 12/16/2013 1:29 PM EnergyGauge D USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 7 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 7 W 10 Vinyl Low-E Double Yes 0.6 0.27 57.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 8 W 10 Vinyl Low-E Double Yes 0.6 0.27 28.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None • 9 NW 11 None Low-E Double Yes 0.6 0.27 17.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds None 10 SE 13 None Low-E Double Yes 0.6 0.27 10.4 ft2 2 ft 0 in 1 ft 0 in None None 11 S 14 None Low-E Double Yes 0.6 0.27 10.4 ft2 15 ft 0 in 1 ft 0 in None None 12 SW 15 Vinyl Low-E Double Yes 0.6 0.27 46.2 ft2 10 ft 0 in 1 ft 0 in None None 13 W 16 None Low-E Double Yes 0.6 0.27 52.0 ft2 2 ft 0 in 1 ft 0 in None None 14 NW 18 None Low-E Double Yes 0.6 0.27 10.0 ft' 2 ft 0 in 1 ft 0 in None None 15 NW 19 None Low-E Double Yes 0.6 0.27 8.0 ft2 2 ft 0 in 1 ft 0 in None None 16 NW 20 None Low-E Double Yes 0.6 0.27 26.9 ft2 2 ft 0 in 1 ft 0 in None None 17 SE 22 None Low-E Double Yes 0.6 0.27 20.8 ft2 2 ft 0 in 1 ft 0 in None None 18 NE 24 None Low-E Double Yes 0.6 0.27 26.9 ft2 2 ft 0 in 1 ft 0 in None None 19 SE 25 None Low-E Double Yes 0.6 0.27 10.4 ft2 2 ft 0 in 1 ft 0 in None None 20 NW 28 None Low-E Double Yes 0.6 0.27 7.0 ft2 2 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 432 ft2 432 ft2 53 ft loft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0003 1526.6 83.81 157.61 .277 5.0107 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Heat Pump None HSPF:8.2 46 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit Split SEER:25 46 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 50 gal 120 deg None 12/16/2013 1:29 PM EnergyGaugeG USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ' —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 774 ft2 SIRS/HALL 774 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ �Jan Feb [[ �Mar ( � r ( ]Ma [X]Jun Jul [X A rl Se Oct Nov HDec Heatin [X]Jan Feb [X]Mar [1 Apr [ ]May [ ]Jun ri Jul [ Aug WOd MNov Dec Ventin [[ ]]Jan Feb [[XX�]Mar [X] r [ ]Ma [ ]Jun Jul [ ]]]Au Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/16/2013 1:29 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 10701 S. OCEAN DRIVE PERMIT#: JENSEN BEACH, FL, 34957- MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors& outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403-2-2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403-3-3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff(gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 12/16/2013 129 PM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 7 of 7 Load Short Form Job: 1868 Date: Nov 11,2011 'rmStralg Entire House By: STEVEN FERRELL alremnq, Project • • For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP Design Information Htg Cig Infiltration Outside db (°F) 42 90 Method Simplified Inside db (°F) 70 75 Construction quality Tight Design TD (°F) 28 15 Fireplaces 1 (Average) Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 23 61 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade BASE 13 PURON HP Trade BASE 13 PURON HP Model 25HBB342(A,W)30 Cond 25HBB342(A,W)30 AHRI ref no3684354 Coil FX4DN(B,F)043 AHRI ref no3684354 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 29050 Btuh Heating output 42000 Btuh @ 47°F Latent cooling 12450 Btuh Temperature rise 28 °F Total cooling 41500 Btuh Actual air flow 1383 cfm Actual air flow 1383 cfm Air flow factor 0.070 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (w) (Btuh) (Btuh) (cfm) (cfm) PDR. ROOM 29 1067 724 75 36 HALL 48 0 0 0 0 KITCHEN 201 1675 2915 118 146 GREAT ROOM 450 5875 10276 413 515 MASTER BEDROOM 337 3627 5577 255 280 WIC 128 1326 1224 93 61 SINK 36 82 74 6 4 LIN. 6 0 0 0 0 LIN 6 0 0 0 0 -TUB 47 0 0 0 0 TQILET/SHWR 50 500 553 35 28 DEN/BR 121 1477 2026 104 102 CLO. 21 0 0 0 0 STRS/ HALL 144 1634 1575 115 79 W/D 29 0 0 0 0 BEDROOM 2 129 2412 2648 170 133 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .` + wrightSOft Right-Sude®Universal 8-0.18 RSU11449 2011-Nov 11 162 1 ACCN _20111MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=W8 Front Door faces Page 1 CLO 10 0 0 0 0 BATH 2 74 0 0 0 0 Entire House 1865 19673 27591 1383 1383 Other equip loads 739 396 Equip. @ 0.95 RSM 26588 Latent cooling 3857 TOTALS 1865 20412 30445 1383 1383 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2011-Nov 11 1 Wright5Oft' Right-Sude®Universal 8.0.18 RSU11449 Page 2 ACCK --2011VAKE&SUSAN RICHARDS RESIDENCE NKE&SUSAN RICHARDS.rup Calc=M18 Front Door faces: r Job: 1868 �--� Building Analysis Date: Nov 11,2011 'ANF�Tvyw; Entire House By: STEVEN FERRELL Project I • • For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (OF) 70 75 Elevation: 25 ft Design TD (OF) 28 15 Latitude: 27'N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb (OF) 42 90 Infiltration: Daily range (OF) - 15 ( L ) Method Simplified Wet bulb (OF) - 78 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) MEMO Component Btuh/ft2 Btuh % of load Walls 3.5 7709 37.8 Glazing 16.8 6954 34.1 Doors 16.8 353 1.7 Ceilings 1.6 1806 8.8 Floors 0.9 978 4.8 Infiltration 0.9 1874 9.2 Ducts 0 0 Piping 0 0 Humidification 0 0 Al! Ventilation 739 3.6 Adjustments 0 Total 204121 100.0 Component Btuh/ft2 Btuh % of load Walls 2.9 6209 22.2 Glazing 34.0 14064 50.3 Doors 17.4 365 1.3 Ceilings 1.5 1692 6.0 Floors 0.5 524 1.9 Infiltration 0.2 337 1.2 Ducts 0 0 Ventilation 396 1.4 . Internal gains 4400 15.7 Blower 0 0 Adjustments 0 Total 27987 100.0 Latent Cooling Load = 3857 Btuh Overall U-value = 0.216 Btuh/ft2-°F Data entries checked. W rl F1tSOft 2011-Nov-1 16:20:19 9 Right-Sud,8 Universal RSU11449 Page 1 ACCK ...2011\MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=W8 Front Doorfaces: Component Constructions Job: 1868Date: Nov 11,2011 N=rm 9 Entire House By: STEVEN FERRELL At 4 HF:-T nl. • Project • • For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (°F) 70 75 Elevation: 25 ft Design TD (°F) 28 15 Latitude: 27°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb (°F) 42 90 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 78 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Bhtff-°F W-°FBth BIWR' Bhh BIWff Bhh Walls Blk wall,stucco ext,r-5 ext bd ins,8"thk, 1/2"gypsum board int fnsh: ne 103 0.136 6.0 3.80 391 3.26 335 Blk wall,stucco ext,r-5 ext bd ins,8"thk, 1/2"gypsum board int fnsh se 666 0.136 6.0 3.80 2535 3.26 2173 s 62 0.136 6.0 3.80 235 3.26 202 sw 94 0.136 6.0 3.80 358 3.26 307 w 247 0.136 6.0 3.80 939 3.26 804 nw 558 0.136 6.0 3.80 2124 3.26 1820 all 1730 0.136 6.0 3.80 6581 3.26 5641 Partitions 12C-Osw:Frm wall,stucco ext, r-13 cav ins,2"x4"wood frm 443 0.091 13.0 2.55 1127 1.28 568 Windows 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: ne 29 0.600 0 16.8 486 27.5 796 2 glazing,cir low-e outr,air gas,vnl frm mat,Or innr, 1/4"gap, 1/4"thk; se 57 0.600 0 16.8 954 27.7 1572 NFRC rated(SHGC=0.27) s 13 0.600 0 16.8 210 15.8 197 w 136 0.600 0 16.8 2281 34.9 4746 nw 84 0.600 0 16.8 1409 27.5 2306 all 318 0.600 0 16.8 5341 30.3 9617 4A3-2ovd:2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr, 1/4" sw 96 0.600 0 16.8 1613 14.7 1407 gap, 1/4"thk;NFRC rated(SHGC=0.27); 10 ft overhang(8 ft window ht,2 ft sep.) Dpors 11JO:Qoor,mtl fbrgl type se 21 0.600 6.3 16.8 353 17.4 365 Ceilings 1M19-Oad:Attic ceiling,asphalt shingles roof mat,r-20 roof ins, 1/2" 1137 0.408 19.0 1.59 1803 1 A9 1690 gypsuM board int fnsh C part ceiling,:C part ceiling,carpet flr fnsh,frm fir, 12"thkns, 1/2" 2 0.221 1.0 1.42 3 1.12 2 gypsum board int fnsh Floors 19A-19cvtp:Flr floor,frm flr,8"thkns,r-19 cav ins, leaky crwl ovr 728 0.049 19.0 1.08 782 0.58 419 2011-Nov-11 16:20:19 wrightsoft Right-Suitee Universal 8.0.18 RSU11449 Page 1 ACCK ..2011\MIKE&SUSAN RICHARDS RESIDENCEIMIKE&SUSAN RICHARDS.rup Cal=W8 Front Door faces Job: 1868 Project Summary Date: Nov 11,2011 Entire House By: STEVEN FERRELL Project • • For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19673 Btuh Structure 27591 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (24 cfm) 739 Btuh Central vent (24 cfm) 396 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20412 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 26588 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Average) Structure 2855 Btuh Ducts 0 Btuh Heating Cooling Central vent (24 cfm) 1003 Btuh Area (ft') 1865 1865 Equipment latent load 3857 Btuh Volume (ft') 17534 17534 Air changes/hour 0.21 0.07 Equipment total load 30445 Btuh Equiv.AVF (cfm) 61 20 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade BASE 13 PURON HP Trade BASE 13 PURON HP Model 25HBB342(A,W)30 Cond 25HBB342(A,W)30 •AHRI ref no3684354 Coil FX4DN(B,F)043 AHRI ref no3684354 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 29050 Btuh "Heating output 42000 Btuh @ 47°F Latent cooling 12450 Btuh Temperature rise 28 OF Total cooling 41500 Btuh Actual air flow 1383 cfm Actual air flow 1383 cfm Air flow factor 0.070 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ^� 2011-Nov 11 16 '�"�"�" wrightsoft Right-Suite®Universal 8.0.18 RSU11449 Page 11 �CF' ._2011\MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces: AED Assessment Job:Date: Nov Nov 11,2011 =rmstrong Entire House By: STEVEN FERRELL Alk ti F1F Sll ry,, Project • • For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (OF) 70 75 Elevation: 25 ft Design TD (OF) 28 15 Latitude: 27ON Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb (OF) 42 90 Infiltration: Daily range (OF) - 15 ( L ) Wet bulb (OF) - 78 Wind speed (mph) 15.0 7.5 Test forAdequate Exposure Hourly Glazing Load 18, 16, 14, 12, 1U .._... _.__. 0 8, 6, 4, 2, p I I 8 9 10 11 12 13 14 15 16 17 18 19 20 eau m oav Maximum hourly glazing load exceeds average by 59.6%. • House does not have adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 3040 Btuh (PFG - 1.3*AFG) 2011-Nov-11 1620:19 1 + wrightsoft Right-Suite®Universal 8.0.18 RSU11449 Page 1 MCA ._2011\MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=W8 Front Door faces f g. FYr{ a ` y y g. • j` I _ Fri IS r y e •��gp, , i i Right-J®Worksheet Job: 1868 ,R*►59 Entire House Date: Nov 11,2011 By: STEVEN FERRELL 1r Room name Entire House PDR. ROOM 2 Exposed wall 230.3 ft 6.8 ft 3 Ceiling height 9.4 ft 10.0 ft heat/cool 4 Room dimensions 6.8 x 4.3 ft 5 Room area 1864.9 ft' 28.7 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft') Load number (Btuh/W°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WJ Blk wall,stucco ext 0.136 ne 3.80 3.26 132 103 391 335 0 0 0 0 �--G 2 glazing,clr low-e 0.600 ne 16.80 27.50 29 0 486 796 0 0 0 0 Blk wall, stucco ext 0.136 se 3.80 3.26 744 666 2535 2173 68 68 257 220 2 glazing,clr low-e 0.600 se 16.80 27.68 57 0 954 1572 0 0 0 0 11 11.10 0.600 se 16.80 17.40 21 21 353 365 0 0 0 0 Blk wall, stucco ext 0.136 s 3.80 3.26 74 62 235 202 0 0 0 0 2 glazing,clr low-e 0.600 s 16.80 15.78 13 0 210 197 0 0 0 0 Blk wall, stucco ext 0.136 sw 3.80 3.26 190 94 358 307 0 0 0 0 4A3-2ovd 0,600 sw 16.80 14.66 96 192 1613 1407 0 0 0 0 �j Blk wall,stucco ext 0.136 w 3.80 3.26 383 247 939 804 0 0 0 0 --.L' 2 glazing,cir low-e 0.600 w 16.80 34.94 136 0 2281 4746 0 0 0 0 Blk wall,stucco ext 0.136 nw 3.80 3.26 642 558 2124 1820 0 0 0 0 2 glazing,clr low-e 0.600 nw 16.80 27.50 84 0 1409 2306 0 0 0 0 P 12C-0sw 0.091 2.55 1.28 443 443 1127 568 43 43 108 55 C 16X19-0ad 0.408 1.59 1.49 1137 1137 1803 1690 0 0 0 0 C C part ceiling, 0.221 1.42 1.12 2 2 3 2 0 0 0 0 F 19A-19cvtr) 0.049 1.08 0.58 728 728 782 419 29 29 31 17 F 19C-19cscp 0.049 0.48 0.25 412 412 196 105 0 0 0 0 6 c)AED excursion 3040 -9 Envelope loss/gain 17799 22854 396 282 .12 a) Infiltration 1874 337 58 11 .b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 10 2300 0 0 Appliances/other 2100 0 .Subtotal(lines 6 to 13) 19673 27591 454 293 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 613 431 14 Subtotal 19673 27591 1067 724 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Total room load 19673 27591 1067 724 Air required(cfm) 1383 1383 75 36 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriightsoft Right-Suite®Universal 8.0.18 RSU11449 2011-Nov 11 16: ge 1 AC,CA Page 1 _2011\MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS rup Cak:=MJ8 Front Door faces: I Right-J® Worksheet Job: 1868 w:r„��„e Entire House Date: Nov 11,2011 U By: STEVEN FERRELL 1 Room name HALL KITCHEN 2 Exposed wall 4.0 ft 10.5 ft 3 Ceiling height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 48.0 ft 1.0 x 201.3 ft 5. Room area 48.0 ft' 201.3 W Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (Btuh/W°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk wall,stucco ext 0.136 ne 3,80 3,26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.600 ne 16.80 27.50 0 0 0 0 0 0 0 0 tl Blk wall, stucco ext 0.136 se 3.80 3.26 40 19 72 62 0 0 0 0 2 glazing,clr low-e 0.600 se 16.80 27.68 0 0 0 0 0 0 0 0 11 11J0 0.600 se 16.80 17.40 21 21 353 365 0 0 0 0 1qJ Blk wall,stucco ext 0.136 s 3.80 3.26 0 0 0 0 0 0 0 0 1---G 2 glazing,clr low-e 0.600 s 16.80 15.78 0 0 0 0 0 0 0 0 �j Blk wall,stucco ext 0.136 sw 3.80 3.26 0 0 0 0 0 0 0 0 t-C 4A3-2ovd 0.600 sw 16.80 14.66 0 0 0 0 0 0 0 0 Blk wall,stucco ext 0.136 w 3.80 3.26 0 0 0 0 0 0 0 0 t-G 2 glazing,clr low-e 0.600 w 16.80 34.94 0 0 0 0 0 0 0 0 V�I Blk wall,stucco ext 0.136 nw 3.80 3.26 0 0 0 0 105 93 354 304 L---G 2 glazing,clr low-e 0.600 nw 16.80 27.50 0 0 0 0 12 0 202 330 P 12C-0sw 0.091 2.55 1.28 160 160 408 205 198 198 503 253 C 16X19-0ad 0.408 1.59 1.49 0 0 0 0 0 0 0 0 C C part ceiling, 0.221 1.42 1.12 0 0 0 0 1 1 2 1 F 19A-19cvtp 0.049 1.08 0.58 48 48 52 28 201 201 216 116 F 19C-19cscp 0.049 0.48 0.25 0 0 0 0 0 0 0 0 6 c)AED excursion -20 19 Envelope loss/gain 884 640 1277 1023 12 a) Infiltration 35 6 91 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 1200 -Subtotal(lines 6 to 13) 919 646 1368 2699 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -919 -646 306 215 14 Subtotal 0 0 1675 2915 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 0 0 1675 2915 Air required(cfm) 0 01 118 146 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrii htsoft 2011-Nov-1116:20:19 9 Right-Suite®Universal 8.0.18 RSU11449 Page 2 ACCA 2011\MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS rup Calc=W8 Front Door faces: J Right-M Worksheet Job: 1868 Entire House Date: Nov 11,2011 By: STEVEN FERRELL 1 Room name WIC SINK 2 Exposed wall 23.3 ft 0 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 127.9 ft 5.8 x 6.3 ft 5 Room area 127.9 ft' 35.9 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft�°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross NIP/S Heat Cool Gross I N/P/S Heat Cool 6 VN Blk wall,stucco ext 0.136 ne 3.80 3.26 0 0 0 0 0 0 0 0 �G 2 glazing,clr low-e 0.600 ne 16.80 27.50 0 0 0 0 0 0 0 0 T� Blk wall,stucco ext 0.136 se 3.80 3.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.600 se 16.80 27.68 0 0 0 0 0 0 0 0 1 1 11 JO 0.600 se 16.80 17.40 0 0 0 0 0 0 0 0 V�I Blk wall,stucco ext 0.136 s 3.80 3.26 0 0 0 0 0 0 0 0 -- 2 glazing,dr low-e 0.600 s 16.80 15.78 0 0 0 0 0 0 0 0 �j Blk wall,stucco ext 0.136 sw 3.80 3.26 0 0 0 0 0 0 0 0 G 4A3-2ovd 0.600 sw 16.80 14.66 0 0 0 0 0 0 0 0 Blk wall,stucco ext 0.136 w 3.80 3.26 58 58 222 190 0 0 0 0 2 glazing,clr low-e 0.600 w 16.80 34.94 0 0 0 0 0 0 0 0 �yJ Blk wall,stucco ext 0.136 nw 3.80 3.26 152 142 538 462 0 0 0 0 L--G 2 glazing,clr low-e 0.600 nw 16.80 27.50 11 0 180 295 0 0 0 0 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 1.59 1,49 128 128 203 190 36 36 57 53 C C part ceiling, 0.221 1.42 1.12 0 0 0 0 0 0 0 0 F 19A-19cvtp 0.049 1.08 0.58 0 0 0 0 0 0 0 0 F 19C-19cscp 0,049 0.48 0.25 0 0 0 0 0 0 0 0 6 c)AED excursion 54 1 -2 Envelope loss/gain 1144 1191 57 52 12 a) Infiltration 182 33 0 0 •b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1326 1224 57 52 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 25 22 14 Subtotal 1326 1224 82 74 15 Dud loads -0% 0% 0 0 -0% 0% 0 0 Total room load 1326 1224 82 ::74 Air required (cfm) 93 61 6 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �.11 wri htsoft g 2011-Nov-1116.2019 TT..T 9 Ri ht-Suite®Universal 8.0.18 RSU11449 Page 4 Acc-,N _ 2011\MIKE 8 SUSAN RICHARDS RESIDENCEWIKE 8 SUSAN RICHARDS rup Calc=W8 Front Door faces: I Right-J®Worksheet Job: 1868 -strong Date: Nov 11,2011 Entire House By: STEVEN FERRELL 1 'Room name LIN. LIN 2 Exposed wall O ft O ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 3.0 x 2.0 ft 2.8 x 2.0 ft 5 ,Room area 6.0 ft2 5.5 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft� Load number (Btuh/ft'°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WJ Blk wall,stucco ext 0.136 ne 3.80 3.26 0 0 0 0 0 0 0 0 L--1 2 glazing,clr low-e 0,600 ne 16.80 27.50 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0.136 se 3.80 3.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.600 se 16.80 27.68 0 0 0 0 0 0 0 0 11 11J0 0.600 se 16.80 17.40 0 0 0 0 0 0 0 0 1qJ Blk wall, stucco ext 0.136 s 3.80 3.26 0 0 0 0 0 0 0 0 L-G 2 glazing,clr low-e 0.600 s 16.80 15.78 0 0 0 0 0 0 0 0 Blk wall,stucco ext 0.136 sw 3.80 3.26 0 0 0 0 0 0 0 0 4A3-2ovd 0.600 sw 16.80 14.66 0 0 0 0 0 0 0 0 Blk wall,stucco ext 0.136 w 3.80 3.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.600 w 16.80 34.94 0 0 0 0 0 0 0 0 V�I Blk wall,stucco ext 0.136 nw 3.80 3.26 0 0 0 0 0 0 0 0 I---G 2 glazing,clr low-e 0.600 nw 16.80 27.50 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 1.59 1.49 6 6 10 9 6 6 9 8 C C part ceiling, 0.221 1.42 1.12 0 0 0 0 0 0 0 0 F 19A-19cvtp 0.049 1.08 0.58 0 0 0 0 0 0 0 0 F 19C-19cscp 0.049 0.48 0.25 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 10 9 9 8 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 ,Subtotal(lines 6 to 13) 10 9 9 8 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -10 -9 -9 -8 14 Subtotal 0 0 0 0 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 0 0 0 0 Air required(cfm) 01 01 0 D Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .1. wri htsot;t 2011-Nov-1116.20:19 f' 9 Right-Suite®Universal 8.0.18 RSU11449 Page 5 ACCA 2011\MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS rup Cak:=MJ8 Front Door faces Right-J® Worksheet Job: Entire House Date: Nov Nov 11,2011 By: STEVEN FERRELL 1 .Room name TUB TOILET/SHWR 2 Exposed wall 0 ft 6.8 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 6.5 x 7.3 ft 1.0 x 49.6 ft 5 •Room area 47.1 ftz 49.6 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft� Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 t Blk wall,stucco ext 0.136 ne 3.80 3.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.600 ne 16.80 27.50 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0.136 se 3.80 3.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.600 se 16.80 27.68 0 0 0 0 0 0 0 0 11 11J0 0.600 se 16.80 17.40 0 0 0 0 0 0 0 0 V�/ Blk wall,stucco ext 0.136 s 3.80 3.26 0 0 0 0 0 0 0 0 L--G 2 glazing,clr low-e 0.600 s 16.80 15.78 0 0 0 0 0 0 0 0 v�v Blk wall, stucco ext 0.136 sw 3.80 3.26 0 0 0 0 0 0 0 0 �--( 4A3-2ovd 0.600 sw 16.80 14.66 0 0 0 0 0 0 0 0 �j Blk wall,stucco ext 0.136 w 3.80 3.26 0 0 0 0 0 0 0 0 `-G 2 glazing,clr low-e 0.600 w 16.80 34.94 0 0 0 0 0 0 0 0 Blk wall,stucco ext 0.136 nw 3.80 3.26 0 0 0 0 62 54 205 176 2 glazing,clr low-e 0.600 nw 16.80 27.50 0 0 0 0 8 0 134 220 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 1.59 1.49 47 47 75 70 50 50 79 74 C C part ceiling, 0.221 1.42 1.12 0 0 0 0 0 0 0 0 F 19A-19cvtp 0.049 1.08 0.58 0 0 0 0 0 0 0 0 F 19C-19cscp 0.049 0.48 0-25 16 16 7 4 16 16 7 4 61 c)AED excursion -2 52 Envelope loss/gain 82 72 425 525 12 a) Infiltration 0 0 54 10 -b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 82 72 479 535 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -82 -72 21 18 14 Subtotal 0 0 500 553 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 0 0 500 553 Air required(cfm) 1 01 01 135 28 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriightsaft Right-SuRe®Universal 8.0.18 RSU11449 2011-Nov 11 1 Pa0e 6 AC CA 2011\MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Cak:=W8 Front Door faces: g Right-.1® Worksheet Job: 1868 Entire House Date: Nov 11,2011 �f By: STEVEN FERRELL 1 Room name DEN/BR CLO. 2 Exposed wall 10.5 ft 5.0 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 121.3 ft 1.0 x 21.2 ft 5 .Room area 121.3 ft' 21.2 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft'-*F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk wall,stucco ext 0.136 ne 3.80 3.26 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.600 ne 16.80 27.50 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0.136 se 3.80 3.26 0 0 0 0 45 45 171 147 2 glazing,clr low-e 0.600 se 16.80 27.68 0 0 0 0 0 0 0 0 11 11J0 0.600 se 16.80 17.40 0 0 0 0 0 0 0 0 1/� Blk wall, stucco ext 0.136 s 3.80 3.26 0 0 0 0 0 0 0 0 --G 2 glazing,cir low-e 0.600 s 16.80 15.78 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0.136 sw 3.80 3.26 0 0 0 0 0 0 0 0 4A3-2ovd 0.600 sw 16.80 14.66 0 0 0 0 0 0 0 0 Blk wall,stucco ext 0.136 w 3.80 3.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.600 w 16.80 34.94 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0.136 nw 3.80 3.26 95 66 250 214 0 0 0 0 t--G 2 glazing,clr low-e 0.600 nw 16.80 27.50 29 0 486 796 0 0 0 0 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 1.59 1_49 121 121 192 180 21 21 34 31 C C part ceiling, 0.221 1.42 1.12 0 0 0 0 0 0 0 0 F 19A-19cvtp 0.049 1.08 0.58 0 0 0 0 0 0 0 0 F 19C-19cscp 0.049 0.48 0.25 120 120 57 31 0 0 0 0 61 c)AEDexcursion 196 -6 Envelope loss/gain 985 1416 205 173 12 a) Infiltration 82 15 39 7 •b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1067 1661 244 180 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 410 365 -244 -180 14 Subtotal 1477 2026 0 0 15 Duct loads I -0% 0% 0 0 _0% 0% 0 0 Total room load 1477 2026 0 0 Air required(cfm) 104 102 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2011-Nov-11 16.20.19 44- wrightsoft Right-Suite®Universal 8 0.18 RSU11449 Page 7 �'� p _20MMIKE&SUSAN RICHARDS RESIDENCEIMIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces. Right-J® Worksheet Job: 1868 �6 =nnstron9 Date: Nov 11,2011 -- Entire House By: STEVEN FERRELL 1 Room name STRS/HALL W/D 2 Exposed wall 14.8 ft 6.5 ft 3 Ceiling height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 144.3 ft 6.5 x 4.5 ft 5 Room area 144.3 ft' 29.3 ft' Ty Construction U-value Or HTM Area (ft� Load Area (" Load number (Btuh/W-'F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 V1J Blk wall, stucco ext 0.136 ne 3.80 3.26 0 0 0 0 0 0 0 0 L--G 2 glazing,clr low-e 0.600 ne 16.80 27.50 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0.136 se 3.80 3.26 133 110 420 360 59 59 223 191 2 glazing,clrlow-e 0.600 se 16.80 27,68 22 0 376 620 0 0 0 0 11 11JO 0,600 se 16,80 17.40 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0.136 s 3.80 3.26 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.600 s 16.80 15.78 0 0 0 0 0 0 0 0 Blk wall, stucco ext 0,136 sw 3,80 3,26 0 0 0 0 0 0 0 0 4A3-2ovd 0.600 sw 16.80 14.66 0 0 0 0 0 0 0 0 �j Blk wall,stucco ext 0.136 w 3.80 3.26 0 0 0 0 0 0 0 0 t--G 2 glazing,clr low-e 0.600 w 16.80 34.94 0 0 0 0 0 0 0 0 �q1 Blk wall,stucco ext 0.136 nw 3.80 3.26 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-e 0.600 nw 16.80 27.50 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 1.59 1.49 144 144 229 214 29 29 46 43 C C part ceiling, 0.221 1.42 1.12 0 0 0 0 0 0 0 0 F 19A-19cvto 0,049 1.08 0.58 0 0 0 0 0 0 0 0 F 19C-19c5cp 0.049 0.48 0.25 38 38 18 10 10 10 5 3 6 c)AEDexcursion -4 -7 Envelope loss/gain 1043 1200 274 229 F12 a) Infiltration 115 21 51 9 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1158 1221 324 238 Less external bad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 476 354 -324 -238 14 Subtotal 1634 1575 0 0 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load T1634 1575 0 0 Air required(cfm) 115 79 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2011-Nov-11 16-2019 Right-Suite®Universal 8.0.18 RSU11449 Page 8 4CCA 2011\MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS rup Calc=W8 Front Door faces System Summary Job: Duct S Y � Nov Date: Nov 11,2011 rmstrong Entire House By: STEVEN FERRELL For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP Heati ng Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.09 in H2O 0.09 in H2O Available static pressure 0.41 in H2O 0.41 in H2O Supply / return available pressure 0.20 / 0.20 in H2O 0.20 / 0.20 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 1383 cfm 1383 cfm Total effective length (TEL) 0 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BEDROOM 2 h 2648 170 133 0 0 OX0 VIFx 0 0 DEN/BR h 2026 104 102 0 0 OX0 VIFx 0 0 GREAT ROOM c 5138 207 258 0 0 OX0 VIFx 0 0 GREAT ROOM-B c 5138 207 258 0 0 OX0 VIFx 0 0 KITCHEN c 2915 118 146 0 0 OX0 VIFx 0 0 MASTER BEDROOM c 5577 255 280 0 0 OX0 VIFx 0 0 PDR. ROOM h 724 75 36 0 0 OX0 VIFx 0 0 SINK h 74 6 4 0 0 OX0 VIFx 0 0 STIRS/HALL h 1575 115 79 0 0 OX0 VIFx 0 0 TOILET/SHWR h 553 35 28 0 0 OX0 VIFx 0 0 WIC h 1224 93 61 0 0 OX0 VIFx 0 0 Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct ame Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 OX0 1383 1383 0 0 0 0 Ox 0 VIFx 2011-Nov-11 16 20.21 L + wrightsoft Right-Suite®Universal 8 0.18 RSU11449 Page 1 gCCA _2011\MIKE&SUSAN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Cab=W8 Front Door faces. Joseph P. McCarty,Architect, Inc. 900 East Osceola Street Stuart, Florida, 34994 772-287-6735 fax: 772-287-4618 DPR Registration Number 9639 December 17, 2013 St. Lucie County Code Zoning Department 2300 Virginia Avenue f. Fort Perce, Florida 34962 qj— RE: 10701 South Ocean Drive, Permit 1202-0207 To whom it may concern: Please 3-0 x 8-0 20 minute fire rated solid core door has been added between garage and the entry v stibule. The door will be on a six inch platform from the garage. Sincerely, Josep JOSEPH P. McCARTY, ARCHITECT, Inc. 900 EAST OSCEOLA STREET 287-6735 STUART FLO JDA D.P.R. Registration Number 9639 3/4N fa1.7WD. ON 2 x 4 JOf8T8 m 16° O,G, l�1 � x 8 HDRB, 9 e e I � o 0 2 x 12 GpNT, po7. f'"TF OR E!XIZT. CONC, {. u. �4r