APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/SITE y(
ADDRESS: �h_
2. DETAILED DESCRIPTION OF PROJECT
l
REVISIONS:
3. CONTRACTOR INFORMATION: �1
STATE of FL REG./CERT.#: C�e�-� I ST.LUCIE COUNTY CERT.#:
BUSINESS NAME: rJ LL
QUALIFIERS NAME: -
ADDRESS: Z L .A-0� J
CITY: U i l / STATE: ZIP: IZ7iS
PHONE(DAYTIME): - S' f e FAX:
4. oW" UILDER,INFORMATION:1-" I NAME: �Llt'V�rl�-L q Z
ADDRESS: O 0
CITY: STATE: ZIP:
PHONE: FAX:
-r1
5. ARCHITECT/ENGINEER INFORMATION:
NAME: Sic
ADDRESS:
CITY: STATE: �_ ZIP:
PHONE(DAYTIME): FAX:
SLCCC:9/23/09
Revised 04/26/2010
�_ I
t
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 78
The lower the EnergyPerformance Index, the more efficient the home.
10701 S. OCEAN DRIVE, JENSEN BEACH, FL, 34957-
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 2257.40 ft2
b. Interior Frame-Wood, Interior R=13.0 442.50 ft2
3. Number of units,if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 2 d. N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=19.0 1138.00 ft2
6. Conditioned floor area(ft2) 1940 b. Under Attic(Vented) R=1.0 76.00 ft2
c. R= ft2
7. Windows- Description Area
a. U-Factor: Dbl,U=0.60 501.49 ft2 11. Ducts R ft2
a.Sup:Attic, Ret:STRS/HALL,AH:Garage 6 774
SHGC: SHGC=0.27
b. U-Factor: N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 46.0 SEER:20.00
SHGC:
d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency
SHGC: a. Electric Heat Pump 46.0 HSPF:8.20
Area Weighted Average Overhang Depth: 2.939 ft.
Area Weighted Average SHGC: 0.270
8. Floor Types Insulation Area 14. Hot water systems
a. Electric Cap:40 gallons
a.Crawlspace R=19.0 818.00 ft2EF:0.92
b. Raised Floor R=0.0 337.00 ft2 b. Conservation features
c. N/A R= ft2
None i
15.Credits I �/� ' PPYat
I certify that this home has complied with the Florida Energy Efficiency Code for Building �F TKE STA7�
Construction through the above energy saving features which will be installed (or exceeded) ti a _ 0
new EPL Display Card will be completed
in this home before final inspection. Otherwise, a .n
based on installed Code co ant fe tures.
Imo'
Builder Signature: Date:
Address of New Home: . Qw o 461 32 City/FL Zip:_-_T&2USeAJ 4WC44
34R s� moo WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
Mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
ST. LUCIE COUNTY
BUILDING DIVISION
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compli nt Software REVIEWED
FOR COM rCE
REVIEWED BY
DATE
PLANS AND PERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
Load Short Form Job: 1868
Date: July 30 2013
Entire House By: STEVEN FERRELL
Project Information
For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP
Design Information
Htg Clg Infiltration
Outside db (*F) 42 90 Method Simplified
Inside db (*F) 70 75 Construction quality Tight
Design TD ff) 28 15 Fireplaces 1 (Average)
Daily range - L
Inside humidity (%) 50 50
Moisture difference (gr/lb) 23 61
HEATING EQUIPMENT COOLING EQUIPMENT
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HCD448A**30 Cond 25HCD448A**30
AHRI ref 5845032 Coil FX4DN(B,F)049
AHRI ref 5845032
Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 32200 Btuh
Heating output 45500 Btuh @ 47°F Latent cooling 13800 Btuh
Temperature rise 27 °F Total cooling 46000 Btuh
Actual air flow 1533 cfm Actual air flow 1533 cfm
Air flow factor 0.066 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.90
ROOM NAME Area Htg load Clg load Htg AVF Cig AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
PDR. ROOM 29 1144 818 75 38
HALL 48 0 0 0 0
KITCHEN 201 1670 2960 110 137
GREAT ROOM 524 7723 14575 507 672
MASTER BEDROOM 337 5012 6513 329 301
4 WIC 128 1434 1325 94 61
SINK 36 82 75 5 3
LIN. 6 0 0 0 0
-LIN 6 0 0 0 0
TUB 47 0 0 0 0
TOILET/SHWR 50 532 603 35 28
DEN/BR 121 1524 2078 100 96
CLO. 21 0 0 0 0
STRS/ HALL 144 1726 1607 113 74
W/D 29 0 0 0 0
BEDROOM 2 129 2532 2680 166 124
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
"A;_ 2014-Jun-03 16:18:18 wrightSOft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1
ACCA ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE
r�
CLO 10 0 0 0 0
BATH 2 74 0 0 0 0
Entire House 1939 23378 33234 1533 1533
Other equip loads 739 396
Equip. @ 0.95 RSM 31948
Latent cooling 3893
TOTALS 1939 24116 35841 1533 1533
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Jun-03 16:18:18
"k- Wr19htSOft' Right-Suite®Universal2013 13.0.10 RSU11449 Page 2
ACCK ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=WEI Front Door faces:SE
Loads for Multiple Orientations Job: 1868
p Date: July 30 2013
Entire House By: STEVEN FERRELL
Project Information
For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUPU Ivy
F, �ZE
Design Conditions
Location: Indoor: Heating Cooling
Fort Pierce, FL, US Indoor temperature ff) 70 75
Elevation: 25 ft Design TD ('F) 28 15
Latitude: 27°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5
Dry bulb ('F) 42 90 Infiltration:
Daily range ('F) - 15 ( L )
Wet bulb ('F) - 78
Wind speed (mph) 15.0 7.5
Front Door North Northeast East Southeast South Southwest West Northwest
Sensible Load (Btuh) 23642 22999 27936 31948 27792 23354 26858 27517
Latent Load (Btuh) 3893 3893 3893 3893 3893 3893 3893 3893
Total Load (Btuh) 27535 26892 31829 35841 31685 27247 30752 31411
Heating AVF (cfm) 1187 1187 1367 1533 1367 1187 1367 1367
Cooling AVF (cfm) 1187 1187 1367 1533 1367 1187 1367 1367
Building Orientation Cooling Load
40000
2
30000
m_
D
A
O
J
O)
0 20000
O
U
m
0
f-
10000
0 —� --
N NE E SE S SW W NW
Direction Front Door faces
Current Orientation: Front Door faces Southeast
Highest Cooling Load: Front Door faces Southeast
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Jun-03 16:18:18
WrlghtSOft Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1
A CA...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=W8 Front Door faces:SE
Buildin Anal sis Job: 1868
g Y Date: July 30 2013
Entire House By: STEVEN FERRELL
Project Information
For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP
Design Conditions-----
Location: Indoor: Heating Cooling
Fort Pierce, FL, US Indoor temperature (°F) 70 75
Elevation: 25 ft Design TD (°F) 28 15
Latitude: 27°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5
Dry bulb (°F) 42 90 Infiltration:
Daily range °F) - 15 ( L ) Method Simplified
Wet bulb (°F) - 78 Construction quality Ti ht
Wind speed (mph) 15.0 7.5 Fireplaces 1 ?Average)
mmme
Component Btuh/ft2 Btuh % of load
Walls 4.0 8657 35.9
Glazing 16.8 8425 34.9
Doors 16.8 353 1.5
Ceilings 1.6 1911 7.9
Floors 1.4 2104 8.7
Infiltration 0.9 1928 8.0
Ducts 0 0
Piping 0 0
Humidification 0 0
Ventilation 739 3.1
Adjustments 0
Total 24116 1 100.0
Component Btuh/ft2 Btuh % of load
Walls 3.2 7022 20.9 -
Glazing 36.3 18193 54.1
Doors 17.4 365 1.1
Ceilings 1.5 1775 5.3
Floors 0.7 1127 3.4
Infiltration 0.2 352 1.0
Ducts 0 0
Ventilation 396 1.2
Internal gains 4400 13.1
Blower 0 0
Adjustments 0
-Total 1336291 100.0
Latent Cooling Load = 3893 Btuh
Overall U-value = 0.231 Btuh/ft2-°F
WARNING: window to floor area ratio = 25.9% - more than 25%.
WI'1 htsoft 2014-Jun-03 16:18:20
9 Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1
/ .CA ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE
Component Constructions Job: 1868
p Date: July 30 2013
Entire House By: STEVEN FERRELL
Project • •
For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROU
ii cAry
U�
Design Conditions
Location: Indoor: Heating Cooling
Fort Pierce, FL, US Indoor temperature (°F) 70 75
Elevation: 25 ft Design TD (°F) 28 15
Latitude: 27°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5
Dry bulb (°F) 42 90 Infiltration:
Daily range (°F) - 15 ( L ) Method Simplified
Wet bulb ( F) - 78 Construction quality Tight
Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ft Btuh/R'-'F ft-'FBtuh BtuhW Btuh BtuhM Btuh
Walls
Blk wall,stucco ext,r-4 ext bd ins,8"thk, 1/2"gypsum board int fnsh: ne 105 0.157 5.0 4.40 462 3.77 396
Blk wall,stucco ext,r-4 ext bd ins,8"thk, 1/2"gypsum board int fnsh se 663 0.157 5.0 4.40 2917 3.77 2501
s 25 0.157 5.0 4.40 109 3.77 94
sw 44 0.157 5.0 4.40 193 3.77 165
w 256 0.157 5.0 4.40 1126 3.77 965
nw 468 0.157 5.0 4.40 2061 3.77 1767
all 1560 0.157 5.0 4.40 6868 3.77 5887
Blk wall,stucco ext,r-5 ext bd ins,8"thk, 1/2"gypsum board int fnsh: se 81 0.136 6.0 3.80 306 3.26 262
Blk wall,stucco ext,r-5 ext bd ins,8"thk, 1/2"gypsum board int fnsh nw 93 0.136 6.0 3.80 355 3.26 305
all 174 0.136 6.0 3.80 662 3.26 567
Partitions
12C-Osw:Frm wall,stucco ext,r-13 cav ins,2"x4"wood frm 443 0.091 13.0 2.55 1127 1.28 568
Windows
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: ne 27 0.600 0 16.8 451 27.5 739
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk; se 42 0.600 0 16.8 699 20.7 862
NFRC rated(SHGC=0.27);2 ft overhang(5.2 ft window ht, 1 It sep.); w 52 0.600 0 16.8 874 32.4 1683
6.67 ft head ht nw 37 0.600 0 16.8 619 27.5 1013
all 157 0.600 0 16.8 2643 27.3 4297
4A3-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, se 30 0.600 0 16.8 504 18.6 557
1/4"thk;NFRC rated(SHGC=0.27);50%blinds 45',medium;2 ft
overhang(5 ft window ht, 1 ft sep.);6.67 ft head ht
2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: se 6 0.600 0 16.8 101 14.2 85
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;
NFRC rated(SHGC=0.27);50%blinds 45°,medium;2 ft overhang(3 ft
window ht, 1 ft sep.);6.67 ft head ht
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: s 10 0.600 0 16.8 175 14.7 152
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;
NFRC rated(SHGC=0.27); 15 ft overhang(5.2 ft window ht, 1 ft sep.);
6.67 ft head ht
2014-Jun-03 16:18:20
14h_ wrightSOft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1
/�i+v� ...AN RICHARDS RESIDENCEMIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE
4A3-2ovd:2 glazing,cir low-e outr,air gas,vnl frm mat,cir innr, 1/4" sw 46 0.600 0 16.8 776 14.7 677
gap, 1/4"thk;NFRC rated(SHGC=0.27); 10 ft overhang(7.7 ft window
-ht, 1 ft sep.);6.67 ft head ht
4A3-2ovd:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4" w 71 0.600 0 16.8 1198 30.1 2148
gap, 1/4"thk;NFRC rated(SHGC=0.27);50%blinds 45°,medium;2 ft
overhang(8 ft window ht,1 ft sep.);6.67 ft head ht
4B3-2fv:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, w 137 0.600 0 16.8 2293 29.6 4041
1/4"thk;NFRC rated(SHGC=0.27);50%blinds 45°,medium;2 ft
overhang(6 ft window ht,1 ft sep.);6.67 ft head ht
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: nw 8 0.600 0 16.8 134 27.5 220
2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr, 1/4"gap, 1/4"thk;
NFRC rated(SHGC=0.27);2 ft overhang(2 ft window ht, 1 ft sep.);
6.67 ft head ht
2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr, 1/4"gap, 1/4"thk: nw 7 0.600 0 16.8 118 27.5 192
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;
NFRC rated(SHGC=0.27);2 ft overhang(3.5 ft window ht, 1 ft sep.);
6.67 ft head ht
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: nw 17 0.600 0 16.8 286 24.8 421
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;
NFRC rated(SHGC=0.27);50%blinds 45°,medium;6.67 ft head ht
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: nw 12 0.600 0 16.8 197 24.8 291
2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;
NFRC rated(SHGC=0.27);50%blinds 45°,medium;2 ft overhang(4.7
ft window ht, 1 ft sep.);6.67 ft head ht
Doors
11JO:Door,mtl fbrgl type se 21 0.600 6.3 16.8 353 17.4 365
Ceilings
16X19-Oad:Attic ceiling,asphalt shingles roof mat,r-20 roof ins, 1/2" 1137 0.408 19.0 1.59 1803 1.49 1690
gypsum board int fnsh
C part ceiling,:C part ceiling,carpet flr fnsh,frm flr, 12"thkns, 1/2" 76 0.221 1.0 1.42 108 1.12 85
gypsum board int fnsh
Floors
19A-Obscp:Part floor,carpet flr fnsh,frm flr, 12"thkns, 1/2"gypsum 337 0.295 0 3.10 1046 1.66 560
board int fnsh
19A-19cvtp:Flr floor,frm flr,8"thkns,r-19 cav ins,leaky crwl ovr 802 0.049 19.0 1.08 862 0.58 462
19C-19cscp:Flr floor,frm flr,6"thkns,carpet flr fnsh,r-2 ext ins,r-19 412 0.049 30.0 0.48 196 0.25 105
cav ins,tight crwl ovr,r-11 wall insul
2014-Jun-03 16:18:20
Wi99htsoft" Right-Suite®Universal 2013 13.0.10 RSU11449 Page 2
XCCK ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE
Pro ect Summa Job: 1868
J � Date: July
30 2013
Entire House By: STEVEN FERRELL
Project Information
For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP
4
Notes:
� r C
Design Information
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 *F Outside db 90 °F
Inside db 70 *F Inside db 75 °F
Design TD 28 *F Design TD 15 °F
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 23378 Btuh Structure 33234 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (24 cfm) 739 Btuh Central vent (24 cfm) 396 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 24116 Btuh Use manufacturer's data In
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 31948 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Tight
Fireplaces 1 (Average) Structure 2891 Btuh
Ducts 0 Btuh
Heating Cooling Central vent (24 cfm) 1003 Btuh
Area (ft2) 1939 1939 Equipment latent load 3893 Btuh
Volume ft') 18279 18279
Air changes/hour 0.21 0.07 Equipment total load 35841 Btuh
Equiv.AVF (cfm) 63 21 Req. total capacity at 0.70 SHR 3.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HCD448A**30 Cond 25HCD448A**30
AHRI ref 5845032 Coil FX4DN(B,F)049
AHRI ref 5845032
Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 32200 Btuh
Heating output 45500 Btuh @ 47°F Latent cooling 13800 Btuh
Temperature rise 27 °F Total cooling 46000 Btuh
Actual air flow 1533 cfm Actual air flow 1533 cfm
Air flow factor 0.066 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.90
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Jun-03 16:18:20
-� Wf IghtSOft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1
...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE
AED Assessment Job: 1868
Date: July 30 2013
Entire House By: STEVEN FERRELL
Project Information
For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP
Design Conditions
Location: Indoor: Heating Cooling
Fort Pierce, FL, US Indoor temperature (°F) 70 75
Elevation: 25 ft Design TD (°F) 28 15
Latitude: 27°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5
Dry bulb (°F) 42 90 Infiltration:
Daily range (°F) - 15 ( L )
Wet bulb (°F) - 78
Wind speed (mph) 15.0 7.5
Test forAdequate Exposure
Hourly Glazing Load 19 ' ,
M1 C
22,000 �V a�Q
20,
18,000
16,000
14.000
B
p 12,000
8
10,000
8.
s,o0o
4,000
z,00o
8 9 10 11 12 13 14 15 16 17 18 19 20
Hoy.or oay
Maximum hourly glazing load exceeds average by 71.7%.
House does not have adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 5112 Btuh (PFG - 1.3*AFG)
2014-Jun-03 16:18:20
wrightSOft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1
ACQ\ ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE
ti
Level 2
Sup Riser
10 x 10 16
CLO 16-W/D i
O.
7 '
STRS/HALL 12
BEDROOM 2 9"
10x10 1 14 x10 14x14 14x14
Y.
10 x 6 LIN. LIN
10x10 6 10x10
TUB 4' 4 x 8 MASTER BEDROOM
BATH 2 SI 9"
DEN/BR
4^
8 x 4 0
ILET/SHW R
6"
WIC
10x6
Job#: 1868 Scale: 1 : 101
Performed by STEVEN FERRELL for: Pagel
MIKE&SUSAN RICHARDS Right-Suite®Universal2013
13.0.10 RSU11449
2014-Jun-03 16:22:28
.IDENCE\MIKE&SUSAN RICHARD...
N
COPY
Level 1
ST Riser PDR. ROOM
16"
STORAGE
6'
HALL 10 x 6
24x24 10x10 10x10
9
9"
GARAGEq16
"
TCHEN
EAT ROOM
7
10 x 10 14"
8"
9"
10x10
Job#: 1868 Scale: 1 : 101
Performed by STEVEN FERRELL for: Page 2
MIKE&SUSAN RICHARDS Right-Suite®Universal 2013
13.0.10 RSU 11449
2014-Jun-03 16:22:28
IDENCBMIKE&SUSAN RICHARD
I
Duct System Summary Job: 1868
Date: July 30 2013
Entire House By: STEVEN FERRELL
Project Information
For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP FilLE CO VmY
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0.09 in H2O 0.09 in H2O
Available static pressure 0.41 in H2O 0.41 in H2O
Supply/ return available pressure 0.349 / 0.061 in H2O 0.349 / 0.061 in H2O
Lowest friction rate 0.099 in/100ft 0.099 in/100ft
Actual air flow 1533 cfm 1533 cfm
Total effective length (TEL) 415 ft
Supply Branch DetailTable
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk
BEDROOM 2 h 2532 166 124 0.128 7.0 Ox 0 VIFx 41.9 230.0 st5
DEN/BR h 1524 100 96 0.114 6.0 Ox0 VIFx 51.9 255.0 st6
GREAT ROOM c 4858 169 224 0.104 9.0 Ox 0 VIFx 30.8 305.0 st3
GREAT ROOM-A c 4858 169 224 0.104 9.0 Ox 0 VIFx 30.1 305.0 st3
GREAT ROOM-B c 4858 169 224 0.099 9.0 Ox 0 VIFx 37.9 315.0 st3
KITCHEN c 2960 110 137 0.149 7.0 Ox 0 VIFx 18.8 215.0 st2
MASTER BEDROOM h 5012 329 301 0.108 9.0 Ox 0 VIFx 62.9 260.0 st6
PDR. ROOM h 1144 75 38 0.146 6.0 Ox 0 VIFx 23.5 215.0 st2
SINK h 82 5 3 0.112 4.0 Ox0 VIFx 55.8 255.0 st6
STIRS/HALL h 1726 113 74 0.110 6.0 Ox 0 VIFx 57.8 260.0 st6
TOILET/SHWR h 532 35 28 0.114 4.0 Ox0 VIFx 52.1 255.0 st6
wlc h 1434 94 61 0.108 6.0 Ox0 VIFx 66.5 255.0 st6
Supply Trunk Detail • -
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st3 Peak AVF 507 672 0.099 629 14.0 0 x 0 VinlFlx st1A
st2 Peak AVF 185 174 0.146 529 8.0 0 x 0 VinlFlx st1
st1A Peak AVF 507 672 0.099 629 14.0 0 x 0 RectFbg st1
st1 Peak AVF 1533 1533 0.099 581 22.0 0 x 0 RectFbg
st6 Peak AVF 676 563 0.108 632 14.0 0 x 0 VinlFlx st5
st5 Peak AVF 842 687 0.108 603 16.0 0 x 0 VinlFlx st4
st4 Peak AVF 842 687 0.108 603 16.0 0 x 0 VinlFlx st1
Bold/italic values have been manually overridden
2014-Jun-03 16:18:20
W1.19htsoft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1
ACCK ...AN RICHARDS RESIDENCEWIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE
Return Branch Detail Table
Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk
• rb1 24x40 1533 1533 62.0 0.099 868 1&0 0x 0 VIFx
lir�t�1
Bold/italic values have been manually overridden
2014-Jun-03 16:18:20
wrightsoft Right-Suite®Universal2013 13.0.10 RSU11449 Page 2
ACCA AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE
FORM 405 10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
• , Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MIKE&SUSAN RICHARDS Builder Name:
Street: 10701 S.OCEAN DRIVE Permit Office:
City,State,Zip: JENSEN BEACH , FL,34957- Permit Number: j
Owner: MIKE&SUSAN RICHARDS Jurisdiction: �J
Design Location: FL,ST_LUCIE_CO_INTL ■
1. New construction or existing New(From Plans) 9. Wall Types(2699.9 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 2257.40 ft2
b. Interior Frame-Wood, Interior R=13.0 442.50 ft2
3. Number of units,if multiple family 1 c. N/A
R= 2 ft
4. Number of Bedrooms 2 d. N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (1214.0 sqft.) Insulation Area
a.Under Attic(Vented) R=19.0 1138.00 ft2
6. Conditioned floor area above grade(ft2) 1940 b.Under Attic(Vented) R=1.0 76.00 ft2
Conditioned floor area below grade(ft2) 0 c. N/A R= ft2
11. Ducts R ft2
7. Windows(501.5 sqft.) Description Area a. Sup:Attic, Ret:STIRS/HALL,AH:Garage 6 774
a. U-Factor: Dbl,U=0.60 501.49 ft2
SHGC: SHGC=0.27
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 46.0 SEER:20.00
c. U-Factor: N/A ft2
SHGC: 13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Heat Pump 46.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.939 ft.
Area Weighted Average SHGC: 0.270 14. Hot water systems
8. Floor Types (1155.0 sqft.) Insulation Area a. Electric Cap:40 gallons
a.Crawlspace R=19.0 818.00 ft2 b. Conservation features EF:0.920
b.Raised Floor R=0.0 337.00 ft2 None
c. N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.258 f1J�7
Total Proposed Modified Loads: 39.53 PASS
Total Standard Reference Loads: 50.40
1 hereby certify that the plans and specifications covered by Review of the plans and 0
4Zk1E S743,
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. h rr,r„ ':;: .';•`'„
PREPARED BY Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this buil 'ng, as designed, is in compliance Florida Statutes.
with the Florida Energy Codal COp WFJ
OWNER/AG N _ BUILDING OFFICIAL:
DATE: _ -- DATE: - -- -
Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7
PROJECT
Title: MIKE&SUSAN RICHARDS Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1940 Lot#
Owner: MIKE&SUSAN RICHARDS Total Stories: 2 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: 10701 S.OCEAN DRIV
Permit Office: Cross Ventilation: No County: ST. LUCIE
Jurisdiction: Whole House Fan: No City,State,Zip: JENSEN BEACH,
Family Type: Single-family FL, 34957-
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,ST_LUCIE_CO_INTL FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 58 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1940 18284.2
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 PDR.ROOM 29 290 No 0 1 Yes Yes Yes
2 HALL 48 480 No 0 1 Yes Yes Yes
3 KITCHEN 201 2010 Yes 2 1 Yes Yes Yes
4 GREAT ROOM 524 5240 No 4 1 Yes Yes Yes
5 MASTER BEDROO 337 3033 No 2 1 1 Yes Yes Yes
6 WIC 128 1152 No 0 1 Yes Yes Yes
7 SINK 36 324 No 0 1 No Yes Yes
8 LIN. 6 54 No 0 1 No Yes Yes
9 LIN 6 50 No 0 1 No Yes Yes
10 TUB 47 423 No 0 1 No Yes Yes
11 TOILET/SHWR 50 450 No 0 1 Yes Yes Yes
12 DEN/BR 121 1089 No 1 1 Yes Yes Yes
13 CLO. 21 189 No 0 1 Yes Yes Yes
14 STRS/HALL 144 1296 No 0 1 Yes Yes Yes
15 W/D 29 261 No 0 1 Yes Yes Yes
16 BEDROOM 2 129 1161 No 1 1 1 Yes Yes Yes
17 CLO 10 90 No 0 1 Yes Yes Yes
18 BATH 2 74 688.2 No 0 1 Yes Yes Yes
� � 7
6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7
I
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Crawlspace PDR.ROOM 6.8 ft 0 28.7 ft2 19 0 1 0
2 Crawlspace HALL 4 ft 0 48 ft2 19 0 1 0
3 Crawlspace KITCHEN 10.5 ft 0 201.3 ft2 19 0 1 0
4 Crawlspace GREAT ROOM 72 ft 0 524.2 ft2 19 0 1 0
5 Raised Floor MASTER BEDRO -__- ---- 337 ft2 0 0 0 1
6 Crawlspace TUB 1 ft 0 15.8 ft2 19 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 1250 ft2 152 ft2 Medium 0.9 No 0.9 No 0 14
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC
1 Full attic Vented 300 1213 ft2 N N
CEILING
# Ceiling Type Space R-Value Area Framing Frac Truss Type
1 Under Attic(Vented) KITCHEN 1 1 ft2 0.1 Wood
2 Under Attic(Vented) GREAT ROOM 1 75 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BEDRO 19 337 ft2 0.1 Wood
4 Under Attic(Vented) WIC 19 128 ft2 0.1 Wood
5 Under Attic(Vented) SINK 19 36 ft2 0.1 Wood
6 Under Attic(Vented) LIN. 19 6 ft2 0.1 Wood
7 Under Attic(Vented) LIN 19 6 ft2 0.1 Wood
8 Under Attic(Vented) TUB 19 47 ft2 0.1 Wood
9 Under Attic(Vented) TOILET/SHWR 19 50 ft2 0.1 Wood
10 Under Attic(Vented) DEN/BR 19 121 ft2 0.1 Wood
11 Under Attic(Vented) CLO. 19 21 ft2 0.1 Wood
12 Under Attic(Vented) STRS/HALL 19 144 ft2 0.1 Wood
13 Under Attic(Vented) W/D 19 29 ft2 0.1 Wood
14 Under Attic(Vented) BEDROOM 2 19 129 ft2 0.1 Wood
15 Under Attic(Vented) CLO 19 10 ft2 0.1 Wood
16 Under Attic(Vented) BATH 2 19 74 ft2 0.1 Wood
to 51
FILEIC' u-j' y
I6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7
WALLS
Adjacent Ornt To Wall Type Space Cavity Width In Height Sheathing Framing Solar Below
Ft
1 SE Exterior Concrete Block-Int InsdRDR.ROOM 4.1 6 9 10 0 67.5 ft2 0 0 0.8 0
2 SW Interior Frame-Wood PDR.ROOM 13 4 3 10 0 42.5 ft2 0 0.25 0.8 0
3 SE Exterior Concrete Block-Int Insul HALL 4.1 4 0 10 0 40.0 ft2 0 0 0.8 0
4 NW PDR. RO Interior Frame-Wood HALL 13 7 9 10 0 77.5 ft2 0 0.25 0.8 0
5 NE PDR. RO Interior Frame-Wood HALL 13 8 3 10 0 82.5 ft2 0 0.25 0.8 0
6 NW Exterior Concrete Block-Int InsulKITCHEN 4.1 10 6 10 0 105.0 ft2 0 0 0.8 0
7 NE PDR. RO Interior Frame-Wood KITCHEN 13 14 6 10 0 145.0 ft2 0 0.25 0.8 0
8 SE PDR. RO Interior Frame-Wood KITCHEN 13 5 3 10 0 52.5 ft2 0 0.25 0.8 0
9 SE Exterior Concrete Block-Int InsQREAT ROO 4.1 27 9 10 0 277.5 ft2 0 0 0.8 0
10 W Exterior Concrete Block-Int InsCRREAT ROO 4.1 33 5 10 0 334.2 ft2 0 0 0.8 0
11 NW Exterior Concrete Block-Int InsGREAT ROO 4.1 10 10 10 0 108.3 ft2 0 0 0.8 0
12 NE PDR. RO Interior Frame-Wood GREAT ROO 13 4 3 10 0 42.5 ft2 0 0.25 0.8 0
13 SE Exterior Concrete Block-Int InsiMASTER BE 4.1 10 0 9 0 90.0 ft2 0 0 0.8 0
14 S Exterior Concrete Block-Int InsMASTER BE 4.1 3 11 9 0 35.3 ft2 0 0 0.8 0
15 SW Exterior Concrete Block-Int InsMASTER BE 4.1 10 0 9 0 90.0 ft2 0 0 0.8 0
16 W Exterior Concrete Block-Int InsMASTER BE 4.1 13 8 9 0 123.0 ft2 0 0 0.8 0
17 W Exterior Concrete Block-Int Insul WIC 4.1 6 6 9 0 58.5 ft2 0 0 0.8 0
18 NW Exterior Concrete Block-Int Insul WIC 4.1 16 11 9 0 152.3 ft2 0 0 0.8 0
19 NW Exterior Concrete Block-Int InsSDILET/SHW 4.1 6 11 9 0 62.3 ft2 0 0 0.8 0
20 NW Exterior Concrete Block-Int Insul DEN/BR 4.1 10 6 9 0 94.5 ft2 0 0 0.8 0
21 SE Exterior Concrete Block-Int Insul CLO. 4.1 5 0 9 0 45.0 ft2 0 0 0.8 0
22 SE Exterior Concrete Block-Int InsSTRS/HALL 4.1 14 9 9 0 132.8 ft2 0 0 0.8 0
23 SE Exterior Concrete Block-Int Insul W/D 4.1 6 6 9 0 58.5 ft2 0 0 0.8 0
24 NE Exterior Concrete Block-Int InsBIEDROOM 2 4.1 10 6 9 0 94.5 ft2 0 0 0.8 0
25 SE Exterior Concrete Block-Int InsBIEDROOM 2 4.1 12 3 9 0 110.3 ft2 0 0 0.8 0
26 SE Exterior Concrete Block-Int Insul CLO 4.1 2 3 9 0 20.3 ft2 0 0 0.8 0
27 NE Exterior Concrete Block-Int Insul BATH 2 4.1 4 0 9 4 37.3 ft2 0 0 0.8 0
28 NW Exterior Concrete Block-Int Insul BATH 2 4.1 12 11 9 4 120.6 ft2 0 0 0.8 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 SE Wood HALL None .6 3 7 21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 SE 1 None Low-E Double Yes 0.6 0.27 6.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None
2 NW 6 None Low-E Double Yes 0.6 0.27 11.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None
3 SE 9 Vinyl Low-E Double Yes 0.6 0.27 30.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None
4 W 10 Vinyl Low-E Double Yes 0.6 0.27 71.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None
5 W 10 Vinyl Low-E Double Yes 0.6 0.27 26.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None
6 W 10 Vinyl Low-E Double Yes 0.6 0.27 25.5 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None
aL Cf
U y
6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 7
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
7 W 10 Vinyl Low-E Double Yes 0.6 0.27 57.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None
8 W 10 Vinyl Low-E Double Yes 0.6 0.27 28.0 ft2 2 It 0 in 1 It 0 in Drapes/blinds None
9 NW 11 None Low-E Double Yes 0.6 0.27 17.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None
10 SE 13 None Low-E Double Yes 0.6 0.27 10.4 ft2 2 ft 0 in 1 ft 0 in None None
11 S 14 None Low-E Double Yes 0.6 0.27 10.4 ft2 15 It 0 in 1 ft 0 in None None
12 SW 15 Vinyl Low-E Double Yes 0.6 0.27 46.2 ft2 10 It 0 in 1 ft 0 in None None
13 W 16 None Low-E Double Yes 0.6 0.27 52.0 112 2 ft 0 in 1 ft 0 in None None
14 NW 18 None Low-E Double Yes 0.6 0.27 10.0 ft2 2 ft 0 in 1 ft 0 in None None
15 NW 19 None Low-E Double Yes 0.6 0.27 8.0 ft2 2 ft 0 in 1 ft 0 in None None
16 NW 20 None Low-E Double Yes 0.6 0.27 26.9 112 2 ft 0 in 1 ft 0 in None None
17 SE 22 None Low-E Double Yes 0.6 0.27 20.8 112 2 ft 0 in 1 It 0 in None None
18 NE 24 None Low-E Double Yes 0.6 0.27 26.9 ft2 2 ft 0 in 1 It 0 in None None
19 SE 25 None Low-E Double Yes 0.6 0.27 10.4 ft2 2 ft 0 in 1 It 0 in None None
20 NW 28 None Low-E Double Yes 0.6 0.27 7.0 ft2 2 ft 0 in 1 It 0 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 432 ft2 432 ft2 53 It loft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess .0003 1526.6 83.81 157.61 .277 5.0107
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.2 46 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:20 46 kBtu/hr cfm 0.7 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.92 40 gal 50 gal 120 deg None
I6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7
l
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 774 ft2 STIRS/HALL 774 ft2 Default Leakage Garage (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr Ma rX Jun X Jul Au Se Oct Nov Dec
Heatin Jan Feb Mar Apr f May [ Jun Jul jXj
AujXj
SeP Oct NNov Dec
Ventin Jan Feb X Mar [Xl A r [ Ma [[[ ]]]Jun Jul Aug Se Oct Nov H Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
I6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7
l
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 10701 S. OCEAN DRIVE PERMIT#:
JENSEN BEACH, FL, 34957-
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and
P P 9
controls cooling system. Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of= 1
&Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70%of heat from
site-recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat>10kW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting.
1 y
fl
r
/2014 4:43 PM Energy augeCR UTA-Fla s2010 Section 405.4.1 Compliant Software Page 7 of 7