Loading...
HomeMy WebLinkAboutRevision-engery calcs FFICE USE ONLY: . .DATE FILED: ��4r-4 PEW__. 1 c REVISION FEE: RECEIPT# i - PLANNING& D VELOP�VIENT SERVICES If BUILDING&CODE REGIbLATION DIVISION 2300 VIRGINIA AVENUF FORT PIERCE,FL 34982--%52y,,,+"' (772)462-1553 ry APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE y( ADDRESS: �h_ 2. DETAILED DESCRIPTION OF PROJECT l REVISIONS: 3. CONTRACTOR INFORMATION: �1 STATE of FL REG./CERT.#: C�e�-� I ST.LUCIE COUNTY CERT.#: BUSINESS NAME: rJ LL QUALIFIERS NAME: - ADDRESS: Z L .A-0� J CITY: U i l / STATE: ZIP: IZ7iS PHONE(DAYTIME): - S' f e FAX: 4. oW" UILDER,INFORMATION:1-" I NAME: �Llt'V�rl�-L q Z ADDRESS: O 0 CITY: STATE: ZIP: PHONE: FAX: -r1 5. ARCHITECT/ENGINEER INFORMATION: NAME: Sic ADDRESS: CITY: STATE: �_ ZIP: PHONE(DAYTIME): FAX: SLCCC:9/23/09 Revised 04/26/2010 �_ I t ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the EnergyPerformance Index, the more efficient the home. 10701 S. OCEAN DRIVE, JENSEN BEACH, FL, 34957- 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 2257.40 ft2 b. Interior Frame-Wood, Interior R=13.0 442.50 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=19.0 1138.00 ft2 6. Conditioned floor area(ft2) 1940 b. Under Attic(Vented) R=1.0 76.00 ft2 c. R= ft2 7. Windows- Description Area a. U-Factor: Dbl,U=0.60 501.49 ft2 11. Ducts R ft2 a.Sup:Attic, Ret:STRS/HALL,AH:Garage 6 774 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 46.0 SEER:20.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 46.0 HSPF:8.20 Area Weighted Average Overhang Depth: 2.939 ft. Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14. Hot water systems a. Electric Cap:40 gallons a.Crawlspace R=19.0 818.00 ft2EF:0.92 b. Raised Floor R=0.0 337.00 ft2 b. Conservation features c. N/A R= ft2 None i 15.Credits I �/� ' PPYat I certify that this home has complied with the Florida Energy Efficiency Code for Building �F TKE STA7� Construction through the above energy saving features which will be installed (or exceeded) ti a _ 0 new EPL Display Card will be completed in this home before final inspection. Otherwise, a .n based on installed Code co ant fe tures. Imo' Builder Signature: Date: Address of New Home: . Qw o 461 32 City/FL Zip:_-_T&2USeAJ 4WC44 34R s� moo WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient Mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ST. LUCIE COUNTY BUILDING DIVISION EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compli nt Software REVIEWED FOR COM rCE REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE Load Short Form Job: 1868 Date: July 30 2013 Entire House By: STEVEN FERRELL Project Information For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP Design Information Htg Clg Infiltration Outside db (*F) 42 90 Method Simplified Inside db (*F) 70 75 Construction quality Tight Design TD ff) 28 15 Fireplaces 1 (Average) Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 23 61 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HCD448A**30 Cond 25HCD448A**30 AHRI ref 5845032 Coil FX4DN(B,F)049 AHRI ref 5845032 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 32200 Btuh Heating output 45500 Btuh @ 47°F Latent cooling 13800 Btuh Temperature rise 27 °F Total cooling 46000 Btuh Actual air flow 1533 cfm Actual air flow 1533 cfm Air flow factor 0.066 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.90 ROOM NAME Area Htg load Clg load Htg AVF Cig AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) PDR. ROOM 29 1144 818 75 38 HALL 48 0 0 0 0 KITCHEN 201 1670 2960 110 137 GREAT ROOM 524 7723 14575 507 672 MASTER BEDROOM 337 5012 6513 329 301 4 WIC 128 1434 1325 94 61 SINK 36 82 75 5 3 LIN. 6 0 0 0 0 -LIN 6 0 0 0 0 TUB 47 0 0 0 0 TOILET/SHWR 50 532 603 35 28 DEN/BR 121 1524 2078 100 96 CLO. 21 0 0 0 0 STRS/ HALL 144 1726 1607 113 74 W/D 29 0 0 0 0 BEDROOM 2 129 2532 2680 166 124 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. "A;_ 2014-Jun-03 16:18:18 wrightSOft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1 ACCA ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE r� CLO 10 0 0 0 0 BATH 2 74 0 0 0 0 Entire House 1939 23378 33234 1533 1533 Other equip loads 739 396 Equip. @ 0.95 RSM 31948 Latent cooling 3893 TOTALS 1939 24116 35841 1533 1533 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Jun-03 16:18:18 "k- Wr19htSOft' Right-Suite®Universal2013 13.0.10 RSU11449 Page 2 ACCK ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=WEI Front Door faces:SE Loads for Multiple Orientations Job: 1868 p Date: July 30 2013 Entire House By: STEVEN FERRELL Project Information For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUPU Ivy F, �ZE Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature ff) 70 75 Elevation: 25 ft Design TD ('F) 28 15 Latitude: 27°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb ('F) 42 90 Infiltration: Daily range ('F) - 15 ( L ) Wet bulb ('F) - 78 Wind speed (mph) 15.0 7.5 Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 23642 22999 27936 31948 27792 23354 26858 27517 Latent Load (Btuh) 3893 3893 3893 3893 3893 3893 3893 3893 Total Load (Btuh) 27535 26892 31829 35841 31685 27247 30752 31411 Heating AVF (cfm) 1187 1187 1367 1533 1367 1187 1367 1367 Cooling AVF (cfm) 1187 1187 1367 1533 1367 1187 1367 1367 Building Orientation Cooling Load 40000 2 30000 m_ D A O J O) 0 20000 O U m 0 f- 10000 0 —� -- N NE E SE S SW W NW Direction Front Door faces Current Orientation: Front Door faces Southeast Highest Cooling Load: Front Door faces Southeast Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Jun-03 16:18:18 WrlghtSOft Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1 A CA...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=W8 Front Door faces:SE Buildin Anal sis Job: 1868 g Y Date: July 30 2013 Entire House By: STEVEN FERRELL Project Information For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP Design Conditions----- Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (°F) 70 75 Elevation: 25 ft Design TD (°F) 28 15 Latitude: 27°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb (°F) 42 90 Infiltration: Daily range °F) - 15 ( L ) Method Simplified Wet bulb (°F) - 78 Construction quality Ti ht Wind speed (mph) 15.0 7.5 Fireplaces 1 ?Average) mmme Component Btuh/ft2 Btuh % of load Walls 4.0 8657 35.9 Glazing 16.8 8425 34.9 Doors 16.8 353 1.5 Ceilings 1.6 1911 7.9 Floors 1.4 2104 8.7 Infiltration 0.9 1928 8.0 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 739 3.1 Adjustments 0 Total 24116 1 100.0 Component Btuh/ft2 Btuh % of load Walls 3.2 7022 20.9 - Glazing 36.3 18193 54.1 Doors 17.4 365 1.1 Ceilings 1.5 1775 5.3 Floors 0.7 1127 3.4 Infiltration 0.2 352 1.0 Ducts 0 0 Ventilation 396 1.2 Internal gains 4400 13.1 Blower 0 0 Adjustments 0 -Total 1336291 100.0 Latent Cooling Load = 3893 Btuh Overall U-value = 0.231 Btuh/ft2-°F WARNING: window to floor area ratio = 25.9% - more than 25%. WI'1 htsoft 2014-Jun-03 16:18:20 9 Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1 / .CA ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE Component Constructions Job: 1868 p Date: July 30 2013 Entire House By: STEVEN FERRELL Project • • For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROU ii cAry U� Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (°F) 70 75 Elevation: 25 ft Design TD (°F) 28 15 Latitude: 27°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb (°F) 42 90 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb ( F) - 78 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft Btuh/R'-'F ft-'FBtuh BtuhW Btuh BtuhM Btuh Walls Blk wall,stucco ext,r-4 ext bd ins,8"thk, 1/2"gypsum board int fnsh: ne 105 0.157 5.0 4.40 462 3.77 396 Blk wall,stucco ext,r-4 ext bd ins,8"thk, 1/2"gypsum board int fnsh se 663 0.157 5.0 4.40 2917 3.77 2501 s 25 0.157 5.0 4.40 109 3.77 94 sw 44 0.157 5.0 4.40 193 3.77 165 w 256 0.157 5.0 4.40 1126 3.77 965 nw 468 0.157 5.0 4.40 2061 3.77 1767 all 1560 0.157 5.0 4.40 6868 3.77 5887 Blk wall,stucco ext,r-5 ext bd ins,8"thk, 1/2"gypsum board int fnsh: se 81 0.136 6.0 3.80 306 3.26 262 Blk wall,stucco ext,r-5 ext bd ins,8"thk, 1/2"gypsum board int fnsh nw 93 0.136 6.0 3.80 355 3.26 305 all 174 0.136 6.0 3.80 662 3.26 567 Partitions 12C-Osw:Frm wall,stucco ext,r-13 cav ins,2"x4"wood frm 443 0.091 13.0 2.55 1127 1.28 568 Windows 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: ne 27 0.600 0 16.8 451 27.5 739 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk; se 42 0.600 0 16.8 699 20.7 862 NFRC rated(SHGC=0.27);2 ft overhang(5.2 ft window ht, 1 It sep.); w 52 0.600 0 16.8 874 32.4 1683 6.67 ft head ht nw 37 0.600 0 16.8 619 27.5 1013 all 157 0.600 0 16.8 2643 27.3 4297 4A3-2ov:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, se 30 0.600 0 16.8 504 18.6 557 1/4"thk;NFRC rated(SHGC=0.27);50%blinds 45',medium;2 ft overhang(5 ft window ht, 1 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: se 6 0.600 0 16.8 101 14.2 85 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk; NFRC rated(SHGC=0.27);50%blinds 45°,medium;2 ft overhang(3 ft window ht, 1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: s 10 0.600 0 16.8 175 14.7 152 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk; NFRC rated(SHGC=0.27); 15 ft overhang(5.2 ft window ht, 1 ft sep.); 6.67 ft head ht 2014-Jun-03 16:18:20 14h_ wrightSOft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1 /�i+v� ...AN RICHARDS RESIDENCEMIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE 4A3-2ovd:2 glazing,cir low-e outr,air gas,vnl frm mat,cir innr, 1/4" sw 46 0.600 0 16.8 776 14.7 677 gap, 1/4"thk;NFRC rated(SHGC=0.27); 10 ft overhang(7.7 ft window -ht, 1 ft sep.);6.67 ft head ht 4A3-2ovd:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4" w 71 0.600 0 16.8 1198 30.1 2148 gap, 1/4"thk;NFRC rated(SHGC=0.27);50%blinds 45°,medium;2 ft overhang(8 ft window ht,1 ft sep.);6.67 ft head ht 4B3-2fv:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, w 137 0.600 0 16.8 2293 29.6 4041 1/4"thk;NFRC rated(SHGC=0.27);50%blinds 45°,medium;2 ft overhang(6 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: nw 8 0.600 0 16.8 134 27.5 220 2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr, 1/4"gap, 1/4"thk; NFRC rated(SHGC=0.27);2 ft overhang(2 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,cir innr, 1/4"gap, 1/4"thk: nw 7 0.600 0 16.8 118 27.5 192 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk; NFRC rated(SHGC=0.27);2 ft overhang(3.5 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: nw 17 0.600 0 16.8 286 24.8 421 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk; NFRC rated(SHGC=0.27);50%blinds 45°,medium;6.67 ft head ht 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk: nw 12 0.600 0 16.8 197 24.8 291 2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk; NFRC rated(SHGC=0.27);50%blinds 45°,medium;2 ft overhang(4.7 ft window ht, 1 ft sep.);6.67 ft head ht Doors 11JO:Door,mtl fbrgl type se 21 0.600 6.3 16.8 353 17.4 365 Ceilings 16X19-Oad:Attic ceiling,asphalt shingles roof mat,r-20 roof ins, 1/2" 1137 0.408 19.0 1.59 1803 1.49 1690 gypsum board int fnsh C part ceiling,:C part ceiling,carpet flr fnsh,frm flr, 12"thkns, 1/2" 76 0.221 1.0 1.42 108 1.12 85 gypsum board int fnsh Floors 19A-Obscp:Part floor,carpet flr fnsh,frm flr, 12"thkns, 1/2"gypsum 337 0.295 0 3.10 1046 1.66 560 board int fnsh 19A-19cvtp:Flr floor,frm flr,8"thkns,r-19 cav ins,leaky crwl ovr 802 0.049 19.0 1.08 862 0.58 462 19C-19cscp:Flr floor,frm flr,6"thkns,carpet flr fnsh,r-2 ext ins,r-19 412 0.049 30.0 0.48 196 0.25 105 cav ins,tight crwl ovr,r-11 wall insul 2014-Jun-03 16:18:20 Wi99htsoft" Right-Suite®Universal 2013 13.0.10 RSU11449 Page 2 XCCK ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE Pro ect Summa Job: 1868 J � Date: July 30 2013 Entire House By: STEVEN FERRELL Project Information For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP 4 Notes: � r C Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 *F Outside db 90 °F Inside db 70 *F Inside db 75 °F Design TD 28 *F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23378 Btuh Structure 33234 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (24 cfm) 739 Btuh Central vent (24 cfm) 396 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24116 Btuh Use manufacturer's data In Rate/swing multiplier 0.95 Infiltration Equipment sensible load 31948 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Average) Structure 2891 Btuh Ducts 0 Btuh Heating Cooling Central vent (24 cfm) 1003 Btuh Area (ft2) 1939 1939 Equipment latent load 3893 Btuh Volume ft') 18279 18279 Air changes/hour 0.21 0.07 Equipment total load 35841 Btuh Equiv.AVF (cfm) 63 21 Req. total capacity at 0.70 SHR 3.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HCD448A**30 Cond 25HCD448A**30 AHRI ref 5845032 Coil FX4DN(B,F)049 AHRI ref 5845032 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 32200 Btuh Heating output 45500 Btuh @ 47°F Latent cooling 13800 Btuh Temperature rise 27 °F Total cooling 46000 Btuh Actual air flow 1533 cfm Actual air flow 1533 cfm Air flow factor 0.066 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.90 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Jun-03 16:18:20 -� Wf IghtSOft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1 ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE AED Assessment Job: 1868 Date: July 30 2013 Entire House By: STEVEN FERRELL Project Information For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP Design Conditions Location: Indoor: Heating Cooling Fort Pierce, FL, US Indoor temperature (°F) 70 75 Elevation: 25 ft Design TD (°F) 28 15 Latitude: 27°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 23.2 61.5 Dry bulb (°F) 42 90 Infiltration: Daily range (°F) - 15 ( L ) Wet bulb (°F) - 78 Wind speed (mph) 15.0 7.5 Test forAdequate Exposure Hourly Glazing Load 19 ' , M1 C 22,000 �V a�Q 20, 18,000 16,000 14.000 B p 12,000 8 10,000 8. s,o0o 4,000 z,00o 8 9 10 11 12 13 14 15 16 17 18 19 20 Hoy.or oay Maximum hourly glazing load exceeds average by 71.7%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 5112 Btuh (PFG - 1.3*AFG) 2014-Jun-03 16:18:20 wrightSOft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1 ACQ\ ...AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE ti Level 2 Sup Riser 10 x 10 16 CLO 16-W/D i O. 7 ' STRS/HALL 12 BEDROOM 2 9" 10x10 1 14 x10 14x14 14x14 Y. 10 x 6 LIN. LIN 10x10 6 10x10 TUB 4' 4 x 8 MASTER BEDROOM BATH 2 SI 9" DEN/BR 4^ 8 x 4 0 ILET/SHW R 6" WIC 10x6 Job#: 1868 Scale: 1 : 101 Performed by STEVEN FERRELL for: Pagel MIKE&SUSAN RICHARDS Right-Suite®Universal2013 13.0.10 RSU11449 2014-Jun-03 16:22:28 .IDENCE\MIKE&SUSAN RICHARD... N COPY Level 1 ST Riser PDR. ROOM 16" STORAGE 6' HALL 10 x 6 24x24 10x10 10x10 9 9" GARAGEq16 " TCHEN EAT ROOM 7 10 x 10 14" 8" 9" 10x10 Job#: 1868 Scale: 1 : 101 Performed by STEVEN FERRELL for: Page 2 MIKE&SUSAN RICHARDS Right-Suite®Universal 2013 13.0.10 RSU 11449 2014-Jun-03 16:22:28 IDENCBMIKE&SUSAN RICHARD I Duct System Summary Job: 1868 Date: July 30 2013 Entire House By: STEVEN FERRELL Project Information For: MIKE & SUSAN RICHARDS, THE HAGEDORN GROUP FilLE CO VmY Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.09 in H2O 0.09 in H2O Available static pressure 0.41 in H2O 0.41 in H2O Supply/ return available pressure 0.349 / 0.061 in H2O 0.349 / 0.061 in H2O Lowest friction rate 0.099 in/100ft 0.099 in/100ft Actual air flow 1533 cfm 1533 cfm Total effective length (TEL) 415 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BEDROOM 2 h 2532 166 124 0.128 7.0 Ox 0 VIFx 41.9 230.0 st5 DEN/BR h 1524 100 96 0.114 6.0 Ox0 VIFx 51.9 255.0 st6 GREAT ROOM c 4858 169 224 0.104 9.0 Ox 0 VIFx 30.8 305.0 st3 GREAT ROOM-A c 4858 169 224 0.104 9.0 Ox 0 VIFx 30.1 305.0 st3 GREAT ROOM-B c 4858 169 224 0.099 9.0 Ox 0 VIFx 37.9 315.0 st3 KITCHEN c 2960 110 137 0.149 7.0 Ox 0 VIFx 18.8 215.0 st2 MASTER BEDROOM h 5012 329 301 0.108 9.0 Ox 0 VIFx 62.9 260.0 st6 PDR. ROOM h 1144 75 38 0.146 6.0 Ox 0 VIFx 23.5 215.0 st2 SINK h 82 5 3 0.112 4.0 Ox0 VIFx 55.8 255.0 st6 STIRS/HALL h 1726 113 74 0.110 6.0 Ox 0 VIFx 57.8 260.0 st6 TOILET/SHWR h 532 35 28 0.114 4.0 Ox0 VIFx 52.1 255.0 st6 wlc h 1434 94 61 0.108 6.0 Ox0 VIFx 66.5 255.0 st6 Supply Trunk Detail • - Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 507 672 0.099 629 14.0 0 x 0 VinlFlx st1A st2 Peak AVF 185 174 0.146 529 8.0 0 x 0 VinlFlx st1 st1A Peak AVF 507 672 0.099 629 14.0 0 x 0 RectFbg st1 st1 Peak AVF 1533 1533 0.099 581 22.0 0 x 0 RectFbg st6 Peak AVF 676 563 0.108 632 14.0 0 x 0 VinlFlx st5 st5 Peak AVF 842 687 0.108 603 16.0 0 x 0 VinlFlx st4 st4 Peak AVF 842 687 0.108 603 16.0 0 x 0 VinlFlx st1 Bold/italic values have been manually overridden 2014-Jun-03 16:18:20 W1.19htsoft' Right-Suite®Universal 2013 13.0.10 RSU11449 Page 1 ACCK ...AN RICHARDS RESIDENCEWIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk • rb1 24x40 1533 1533 62.0 0.099 868 1&0 0x 0 VIFx lir�t�1 Bold/italic values have been manually overridden 2014-Jun-03 16:18:20 wrightsoft Right-Suite®Universal2013 13.0.10 RSU11449 Page 2 ACCA AN RICHARDS RESIDENCE\MIKE&SUSAN RICHARDS.rup Calc=MJ8 Front Door faces:SE FORM 405 10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION • , Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MIKE&SUSAN RICHARDS Builder Name: Street: 10701 S.OCEAN DRIVE Permit Office: City,State,Zip: JENSEN BEACH , FL,34957- Permit Number: j Owner: MIKE&SUSAN RICHARDS Jurisdiction: �J Design Location: FL,ST_LUCIE_CO_INTL ■ 1. New construction or existing New(From Plans) 9. Wall Types(2699.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 2257.40 ft2 b. Interior Frame-Wood, Interior R=13.0 442.50 ft2 3. Number of units,if multiple family 1 c. N/A R= 2 ft 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1214.0 sqft.) Insulation Area a.Under Attic(Vented) R=19.0 1138.00 ft2 6. Conditioned floor area above grade(ft2) 1940 b.Under Attic(Vented) R=1.0 76.00 ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(501.5 sqft.) Description Area a. Sup:Attic, Ret:STIRS/HALL,AH:Garage 6 774 a. U-Factor: Dbl,U=0.60 501.49 ft2 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 46.0 SEER:20.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 46.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.939 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems 8. Floor Types (1155.0 sqft.) Insulation Area a. Electric Cap:40 gallons a.Crawlspace R=19.0 818.00 ft2 b. Conservation features EF:0.920 b.Raised Floor R=0.0 337.00 ft2 None c. N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.258 f1J�7 Total Proposed Modified Loads: 39.53 PASS Total Standard Reference Loads: 50.40 1 hereby certify that the plans and specifications covered by Review of the plans and 0 4Zk1E S743, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. h rr,r„ ':;: .';•`'„ PREPARED BY Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this buil 'ng, as designed, is in compliance Florida Statutes. with the Florida Energy Codal COp WFJ OWNER/AG N _ BUILDING OFFICIAL: DATE: _ -- DATE: - -- - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7 PROJECT Title: MIKE&SUSAN RICHARDS Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1940 Lot# Owner: MIKE&SUSAN RICHARDS Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 10701 S.OCEAN DRIV Permit Office: Cross Ventilation: No County: ST. LUCIE Jurisdiction: Whole House Fan: No City,State,Zip: JENSEN BEACH, Family Type: Single-family FL, 34957- New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST_LUCIE_CO_INTL FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 58 Medium BLOCKS Number Name Area Volume 1 Entire House 1940 18284.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 PDR.ROOM 29 290 No 0 1 Yes Yes Yes 2 HALL 48 480 No 0 1 Yes Yes Yes 3 KITCHEN 201 2010 Yes 2 1 Yes Yes Yes 4 GREAT ROOM 524 5240 No 4 1 Yes Yes Yes 5 MASTER BEDROO 337 3033 No 2 1 1 Yes Yes Yes 6 WIC 128 1152 No 0 1 Yes Yes Yes 7 SINK 36 324 No 0 1 No Yes Yes 8 LIN. 6 54 No 0 1 No Yes Yes 9 LIN 6 50 No 0 1 No Yes Yes 10 TUB 47 423 No 0 1 No Yes Yes 11 TOILET/SHWR 50 450 No 0 1 Yes Yes Yes 12 DEN/BR 121 1089 No 1 1 Yes Yes Yes 13 CLO. 21 189 No 0 1 Yes Yes Yes 14 STRS/HALL 144 1296 No 0 1 Yes Yes Yes 15 W/D 29 261 No 0 1 Yes Yes Yes 16 BEDROOM 2 129 1161 No 1 1 1 Yes Yes Yes 17 CLO 10 90 No 0 1 Yes Yes Yes 18 BATH 2 74 688.2 No 0 1 Yes Yes Yes � � 7 6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7 I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Crawlspace PDR.ROOM 6.8 ft 0 28.7 ft2 19 0 1 0 2 Crawlspace HALL 4 ft 0 48 ft2 19 0 1 0 3 Crawlspace KITCHEN 10.5 ft 0 201.3 ft2 19 0 1 0 4 Crawlspace GREAT ROOM 72 ft 0 524.2 ft2 19 0 1 0 5 Raised Floor MASTER BEDRO -__- ---- 337 ft2 0 0 0 1 6 Crawlspace TUB 1 ft 0 15.8 ft2 19 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1250 ft2 152 ft2 Medium 0.9 No 0.9 No 0 14 ATTIC V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC 1 Full attic Vented 300 1213 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) KITCHEN 1 1 ft2 0.1 Wood 2 Under Attic(Vented) GREAT ROOM 1 75 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BEDRO 19 337 ft2 0.1 Wood 4 Under Attic(Vented) WIC 19 128 ft2 0.1 Wood 5 Under Attic(Vented) SINK 19 36 ft2 0.1 Wood 6 Under Attic(Vented) LIN. 19 6 ft2 0.1 Wood 7 Under Attic(Vented) LIN 19 6 ft2 0.1 Wood 8 Under Attic(Vented) TUB 19 47 ft2 0.1 Wood 9 Under Attic(Vented) TOILET/SHWR 19 50 ft2 0.1 Wood 10 Under Attic(Vented) DEN/BR 19 121 ft2 0.1 Wood 11 Under Attic(Vented) CLO. 19 21 ft2 0.1 Wood 12 Under Attic(Vented) STRS/HALL 19 144 ft2 0.1 Wood 13 Under Attic(Vented) W/D 19 29 ft2 0.1 Wood 14 Under Attic(Vented) BEDROOM 2 19 129 ft2 0.1 Wood 15 Under Attic(Vented) CLO 19 10 ft2 0.1 Wood 16 Under Attic(Vented) BATH 2 19 74 ft2 0.1 Wood to 51 FILEIC' u-j' y I6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7 WALLS Adjacent Ornt To Wall Type Space Cavity Width In Height Sheathing Framing Solar Below Ft 1 SE Exterior Concrete Block-Int InsdRDR.ROOM 4.1 6 9 10 0 67.5 ft2 0 0 0.8 0 2 SW Interior Frame-Wood PDR.ROOM 13 4 3 10 0 42.5 ft2 0 0.25 0.8 0 3 SE Exterior Concrete Block-Int Insul HALL 4.1 4 0 10 0 40.0 ft2 0 0 0.8 0 4 NW PDR. RO Interior Frame-Wood HALL 13 7 9 10 0 77.5 ft2 0 0.25 0.8 0 5 NE PDR. RO Interior Frame-Wood HALL 13 8 3 10 0 82.5 ft2 0 0.25 0.8 0 6 NW Exterior Concrete Block-Int InsulKITCHEN 4.1 10 6 10 0 105.0 ft2 0 0 0.8 0 7 NE PDR. RO Interior Frame-Wood KITCHEN 13 14 6 10 0 145.0 ft2 0 0.25 0.8 0 8 SE PDR. RO Interior Frame-Wood KITCHEN 13 5 3 10 0 52.5 ft2 0 0.25 0.8 0 9 SE Exterior Concrete Block-Int InsQREAT ROO 4.1 27 9 10 0 277.5 ft2 0 0 0.8 0 10 W Exterior Concrete Block-Int InsCRREAT ROO 4.1 33 5 10 0 334.2 ft2 0 0 0.8 0 11 NW Exterior Concrete Block-Int InsGREAT ROO 4.1 10 10 10 0 108.3 ft2 0 0 0.8 0 12 NE PDR. RO Interior Frame-Wood GREAT ROO 13 4 3 10 0 42.5 ft2 0 0.25 0.8 0 13 SE Exterior Concrete Block-Int InsiMASTER BE 4.1 10 0 9 0 90.0 ft2 0 0 0.8 0 14 S Exterior Concrete Block-Int InsMASTER BE 4.1 3 11 9 0 35.3 ft2 0 0 0.8 0 15 SW Exterior Concrete Block-Int InsMASTER BE 4.1 10 0 9 0 90.0 ft2 0 0 0.8 0 16 W Exterior Concrete Block-Int InsMASTER BE 4.1 13 8 9 0 123.0 ft2 0 0 0.8 0 17 W Exterior Concrete Block-Int Insul WIC 4.1 6 6 9 0 58.5 ft2 0 0 0.8 0 18 NW Exterior Concrete Block-Int Insul WIC 4.1 16 11 9 0 152.3 ft2 0 0 0.8 0 19 NW Exterior Concrete Block-Int InsSDILET/SHW 4.1 6 11 9 0 62.3 ft2 0 0 0.8 0 20 NW Exterior Concrete Block-Int Insul DEN/BR 4.1 10 6 9 0 94.5 ft2 0 0 0.8 0 21 SE Exterior Concrete Block-Int Insul CLO. 4.1 5 0 9 0 45.0 ft2 0 0 0.8 0 22 SE Exterior Concrete Block-Int InsSTRS/HALL 4.1 14 9 9 0 132.8 ft2 0 0 0.8 0 23 SE Exterior Concrete Block-Int Insul W/D 4.1 6 6 9 0 58.5 ft2 0 0 0.8 0 24 NE Exterior Concrete Block-Int InsBIEDROOM 2 4.1 10 6 9 0 94.5 ft2 0 0 0.8 0 25 SE Exterior Concrete Block-Int InsBIEDROOM 2 4.1 12 3 9 0 110.3 ft2 0 0 0.8 0 26 SE Exterior Concrete Block-Int Insul CLO 4.1 2 3 9 0 20.3 ft2 0 0 0.8 0 27 NE Exterior Concrete Block-Int Insul BATH 2 4.1 4 0 9 4 37.3 ft2 0 0 0.8 0 28 NW Exterior Concrete Block-Int Insul BATH 2 4.1 12 11 9 4 120.6 ft2 0 0 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Wood HALL None .6 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 SE 1 None Low-E Double Yes 0.6 0.27 6.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 2 NW 6 None Low-E Double Yes 0.6 0.27 11.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 3 SE 9 Vinyl Low-E Double Yes 0.6 0.27 30.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 4 W 10 Vinyl Low-E Double Yes 0.6 0.27 71.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 5 W 10 Vinyl Low-E Double Yes 0.6 0.27 26.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 6 W 10 Vinyl Low-E Double Yes 0.6 0.27 25.5 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None aL Cf U y 6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 7 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 7 W 10 Vinyl Low-E Double Yes 0.6 0.27 57.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds None 8 W 10 Vinyl Low-E Double Yes 0.6 0.27 28.0 ft2 2 It 0 in 1 It 0 in Drapes/blinds None 9 NW 11 None Low-E Double Yes 0.6 0.27 17.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 10 SE 13 None Low-E Double Yes 0.6 0.27 10.4 ft2 2 ft 0 in 1 ft 0 in None None 11 S 14 None Low-E Double Yes 0.6 0.27 10.4 ft2 15 It 0 in 1 ft 0 in None None 12 SW 15 Vinyl Low-E Double Yes 0.6 0.27 46.2 ft2 10 It 0 in 1 ft 0 in None None 13 W 16 None Low-E Double Yes 0.6 0.27 52.0 112 2 ft 0 in 1 ft 0 in None None 14 NW 18 None Low-E Double Yes 0.6 0.27 10.0 ft2 2 ft 0 in 1 ft 0 in None None 15 NW 19 None Low-E Double Yes 0.6 0.27 8.0 ft2 2 ft 0 in 1 ft 0 in None None 16 NW 20 None Low-E Double Yes 0.6 0.27 26.9 112 2 ft 0 in 1 ft 0 in None None 17 SE 22 None Low-E Double Yes 0.6 0.27 20.8 112 2 ft 0 in 1 It 0 in None None 18 NE 24 None Low-E Double Yes 0.6 0.27 26.9 ft2 2 ft 0 in 1 It 0 in None None 19 SE 25 None Low-E Double Yes 0.6 0.27 10.4 ft2 2 ft 0 in 1 It 0 in None None 20 NW 28 None Low-E Double Yes 0.6 0.27 7.0 ft2 2 ft 0 in 1 It 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 432 ft2 432 ft2 53 It loft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0003 1526.6 83.81 157.61 .277 5.0107 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 46 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:20 46 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 50 gal 120 deg None I6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7 l SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 774 ft2 STIRS/HALL 774 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr Ma rX Jun X Jul Au Se Oct Nov Dec Heatin Jan Feb Mar Apr f May [ Jun Jul jXj AujXj SeP Oct NNov Dec Ventin Jan Feb X Mar [Xl A r [ Ma [[[ ]]]Jun Jul Aug Se Oct Nov H Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I6/3/2014 4:43 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7 l FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 10701 S. OCEAN DRIVE PERMIT#: JENSEN BEACH, FL, 34957- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and P P 9 controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 1 y fl r /2014 4:43 PM Energy augeCR UTA-Fla s2010 Section 405.4.1 Compliant Software Page 7 of 7