Loading...
HomeMy WebLinkAbout5207 IDIAN BEND LN_PERMIT APP DOCSAll APPLICABLE INFO MUST BE OMPLETED FOR APPLICATION TO BE ACCEPTED Date`:— 25 2 Permit Number: • Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential X PERMIT TYPE: PLUMBING PROPOSED IMPROVEMENT LOCATION: Address: 5207 Indian Bend LN Property Tax ID #: 1312-800-0026-000-5 Site Plan Name: Project Name: WATER HEATER DETAILED DESCRIPTION OF WORK: 50- GALLON ELECTRIC WATER HEATER REPLACEMENT CONSTRUCTION INFORMATION: Additional work to be performed under this permit — check all that apply: Lot No. Block No. _Mechanical _ Gas Tank —Gas Piping _ Shutters _ Windows/Doors Electric Plumbing _Sprinklers _Generator _Roof Pitch Total Sq. Ft of Construction: Cost of Construction: $ 1813.75 Sq. Ft. of First Floor: Utilities: _ Sewer _ Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Yolanda Knowlton Name: RICHARD BASSOFF Address: 5207 Indian Bend LN Company: ADMIRAL PLUMBING SERVICES, A SERVICE EXPERTS COMPANY City: FORT PIERCE FL State: _ Zip Code: 34951 Fax: Phone No.772-332-0298 Address:2895 JUPITER PARK DR STE 700 City: JUPITER State: FL Zip Code: 33458 Fax: Phone No 561-746-1180 E-Mail: mikeknow@att.net Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail 208PERMITTING@SERVICEEXPERTS.COM State or County License CFC-1426115 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable Name: MORTGAGE COMPANY: Not Applicable Name: Address: Address: City: State: Zip: Phone City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: BONDING COMPANY: _Not Applicable Name: Address: Address: City: Zip: Phone: City: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." 6Z��-o / Z /// - Signature of Owner/ Lesse /C r ctor as Agent for Owner Signature of Contra r nse Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF PALM BEACH COUNTY OF PALM BEACH The forgoing instr ment,�was acknowledgedO'aibeyore me The forgoinginstr mental was acknowledged before me 2 b this�day of 20 b this day of J(Jf le.. 202 RICHARD BASSOFF RICHARD BASSOFF Name of person making statement. Name of person making statement. Personall Known OR Produced Identification Personally Known A_ OR Produced Identification Type of I ntificati Type of Identification Pr uce Produce d Q/1/t/////0 ------------------ (Si atureof u ie ofKbajda)lcState aFlonCe Jacqueline nature o N ublic tgrgpiFlo State aFlonda mot. GeorgescuMY C � 233150 T Ja ueline acu GGG+G 233150 Sg missio Epic mmission EY 21 a & 2022 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Hev. 2/7/19 x Adhdnd Admiral Plumbing Services PLUMBING SERVICES A Service Experts Company r A Service Experts Company 2895 Jupiter Park DR #700 Jupiter, FL 33458 C 561-746-1180 License: CFC 1426115 Billing Address Yolanda Knowlton 5207Indian Bend Lane Fort Pierce, FL 34951 USA Description of Work Installed 50 gallon water heater with expansion tank, ball valve, pan and plumbing permit no leaks Task# Description ELCWHSTD-L2 New Electric Water Heater -Standard Size 20-50 Gallon excluding 50 Gallon Low Tanks or Custom Sizes (See Premium / Custom Option) 6 Year Manufacturers Warranty (Upgrade to Premium for 10 Year) Access to heater is normal with no extraordinary installation requirements 'MUST ADD: Required Permit to Meet Local Municipal, County and State Building Codes ' MUST ADD: Installation Packages to meet Job Demands & Requirements Invoice 74773219 Invoice Date(OfS/2021 Terms COD ompleted DateV 5/2021 Customer PO Job Address Yolanda Knowlton 5207 Indian Bend Lane Fort Pierce, FL 34951 USA Quantity Your Price Your Total 3.00 $1.278.25 $1,278.25 ASK ABOUT OUR ADMIRAL ADVANTAGE BASIC PLAN — No worry hot water for only $32.99 ELCWHIP-STD ADMIRAL STANDARD INSTALLATION UTILIZING PRIMARILY EXISTING COMPONENTS IF ALL 1.00 $360.50 $360.50 ARE STILL IN GOOD CONDITION AND INSTALLED PROPERLY TO CODE Professional installation of New Electric Water Heater 'Retrofit Copper Piping 'Install to Code 'Haul off and Dispose / Recycle old Water Heater Permit WH Water Heater - Permit 1.00 $225.00 $225.00 'Required by Building Department Discount Discount- Website 1.00 $-50.00 $-50.00 Paid On Type Memo Amount (0 /5/2021 Visa $1,813.75 Sub -Total $1,813,75 Tax $0.00 Total Due $1,813.75 Payment $2,813.75 Balance Due $0.00 I hereby agree to have Admiral Plumbing Services A Service Experts Company complete the work described for the proposed price regardless of the time it takes to complete the work. �0 /5/2021 1 hereby acknowledge the satisfactory completion of the above described work. I authorize Admiral Plumbing Services A Service Experts Company to charge the agreed amount to my credit card provided herein. I agree that I Will pay for this purchase in accordance with the issuing bank cardholder agreement. f ' . _.�j, _ . _ _: c� . .... 1 I . _ ..• �. .�l .r.. _ � _ _ .l'. .. t � ... _ I.'� ... _ .. � 1 � . .. ... .. � it - . _ . .: �'_. �. ._. _ _._ .. 1 _ ._ � 1 .1 � ' a The new degree of comfort: Professional Classic® electric water heaters are engineered for longer life - resistored heating elements and premium grade anode rod Efficiency •.90-.93UEF • Isolated tank design reduces conductive heat loss • Resistored copper upper element and resistored Lifeguard" stainless steel lower element to prolong anode rod and tank life Performance • FHR: 45 - 67 gallons, based on gallon capacity • Recovery: 21 GPH at a 900 F rise System Sentinel (Available on selected models) • Exclusive diagnostic system with glowing LEDs that verify heating element operation. LEDs pin point the exact location of functioning or non- functioning heating elements Longer Life • Premium grade anode rod provides long-lasting tank protection Features • Electric junction box located above heating elements for easy installation • Over -temperature protector cuts off power in excess temperature situations • Automatic thermostat keeps water at desired temperature Plus... • Rheemglas9 tank lining resists corrosion and prolongs tank fife • EverMeen- self cleaning device fights harmful sediment build-up with a high -velocity spiraling water stream - helps operating efficiency by saving energy, money and improving tank life .rt • Enhanced -flow brass drain valve • Temperature and pressure relief valve included • HUD certified for manufactured housing and modular construction • Low lead compliant Warranty • 6-Year limited tank and parts warranty" • With ProtectionPlus- the 6-year limited tank warranty becomes 10-year 'See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to the AHRI Operations Manual and D.O.E. procedures. Units meet or exceed the energy effidency, requirements of NAECA, ASHRAE standard 90, Ice Code and all state energy efficiency performance criteria. Residential Electric Water Professional Classic Water Heaters Professional Classic 19.9 to 55-Gallon Capacities 240 Volt AC/Single Phase Double and Single Element Models Electric m See specifications chart on back. PRINTED IN USA. DWI M FORM NO. PROE RH N Rev. 8 1 1 The rew de ram of cai Professional Ciassic® Specifications Residential Electric Water Professional Classic Water Heaters DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO. T y P E NOMKU. WLLON CAPNCRY "TO) GALLON CARAC I, MODEL NUMaei i LIEF RFSrNWR Anni 6PN. ROy1Y ECR WO.RH. WFR19E TANK Nacarr A mmwm WAI WNM a pWAE191 C APPROL SNW W. 09a1 UNIWRM ENERGY FACmR PER Tell 30 27 PROE30 T2 RH95' 46 21 47-1/2 50. 8 19-1/4 92 0.92 Tall 40 36 PROE40 T2 RH95' 55 21 60-314 63-5/8 19-1/4 109 0.93 Tall SO 45 PROEO T2 AH951 63 21 58-6/8 61-5/8 20-1/4 121 0.93 Tall 55 55 PROE55 T2 RH94 72 21 57 59-3/4 22-1/4 128 0.92 Med. 30 27 PROE30 M2 RH95' 45 21 37-1/2 40-1/2 20-1/4 92 0.90 Mad. 40 36 PROE40 M2 RH95' 55 21 48-1/4 50-1/2 20-1/4 106 0.93 Mad. 50 45 PROE50 M2 RH95' 62 21 48 50-1/2 23 132 0.93 Short 199 - PROE20 S2 RH - 21 31-1/2 31-112 17 62 - Short 28 25 PROE28 S2 RH95 45 21 30 31-1/8 23 95 0.92 Short 30 27 PROE30 S2 RH956- 48 30-1/8 32 /g-V4 95 0.92 Short 38 33 PROE36 S2 RH95 46 2121 31-6 33 24-11 118 0.92 Short 38 35 PROE38 S2 RH95 8" 51 21 31-1/2 32-5/8 23 108 0.92 Short 4] 43 PRCE47 S2 RH95 54 21 32 34 26-1/4 149 0.93 Uniform Energy Factor and rated gallon capacity based on Department of Energy (00E] requirevrents. r System Sentinel optional. Add ECt to the and of the model number. System Sending not available on single element models, available on dual element models only. System Sentinel not available In excess of 5 kW on 20S y models. " Water Rasta drtellsons prior W mWing mutation bielket that is rdLced with wate'Iteater.. • Heaters falNled vM19Wtlartl 240 volt AC, angle phase non -a" a,x! ous Miring, and 450D watt upper End bwer heating eMme ts. • If heating Moments of different wattages than Grose shown are demanded by zone maul erverm. they must be specifically, requested. • Snge Element modals a✓alabe on specid order (601 max.). 3ubstituta"I' for'T in model rnunW.. • Special Wring Options -A tinted numher of special wing opuon5 are avalable. Consult factory fa Puce and availabiry. • Al models equipped win heat traps. Recovery = wa 101.2.42 x temp. rise °F. Example: 4500W =21 GPH 2.42 x 90° Recovery calculations used are based an 45M was elements used in non-vmuttaneow cpaaBm. DIAMETER WATER CONNECTIONS ALL 3/4" N.P.T. In keeping With ifs policy of continuous progress and product improvement Roses; reserves fhe nght to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com PRINTED IN U SA.OWIB WP FORM NO. PROE RH N Rea 8