HomeMy WebLinkAboutAPPROVED Savage-engineeringDESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS 1. THE 2020 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-16 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFERENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = C FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 43 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 34 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 12 PSF VERTICAL PRESSURES ON SOLID SURFACES = 36 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = •88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 FOUNDATION DESIGN (1) PROPOSED 24"X24"X24" ISOLATED FOOTERS W/ (3) #5 REBAR EACH WAY 3000 PSI W/ FIBERMESH MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1"X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6' FROM ENDS RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTURALLY SOUND. 4. CONTRACTOR TO PROVIDE NOA'S & INSTALL ALL MATERIALS AS PER MANUFACTURER'S SPECIFICATIONS. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. SHEET NO. DRAWING INDEX S/01 GENERAL NOTES S/02 PLAN/ ELEVATIONS S/03 FOUNDATION PLAN S/04 DETAILS NEW ALUMINUM ROOF CANOPY SEE FOUNDATION PLAN SHEET-03 ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2"4.044" 2 x 3: 2"x3"x0.050" 2 x 4: 2"x4"x0.050" 2 x 5: 2"x5"x0.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"x0.044" 1 x 3: 1 "x3"x0.045" SNAP SECTIONS 2 x 2 SNAP: 2"x2"x0.045" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 2x4"x0.044"x0.109' 2 x 5 SMB: 2x5"0.050"0.100" 2 x 6 SMB: 2x6"x0.050"x0.129' 2 x 7 SMB: 20"0.0570.129' 2 x 8 SMB: 2"x8"x0.072"x0.124' 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2x10"x0.092"x0.398" DETAIL A a V J � O N I- ch ZZo O n-/ U LLJ -1 0ao- � L1J � d7 Z� LLi 0 a� w Q N Q Q 2 0 O co ry J a - IL 0 o� c�a w a c CoS 0 E u.i w rn N O T_ N O z H U W O ry a_ 0 Y W W U LL W W >U fr-D Uj W J W o (D F- >o� QCO w U) I- W 0 IL 25% O/H OF LAST PANEL WIDTH ALONG SIDES, TYP. 36" (MAX.) O/H AT FRONT ATTACHED TO HOUSE (FASCIA MOUNT) o g i 3" X .032" X 11-6 Q I COMPOSITE PANELS o i 3003-H154 `� 0G 1/4"-1' SLOPE (MIN.) oz (FL.# 7561.1-R5 OLu 0 o ; ■= 3X3X.125 \gyp U I 2X8SM B O 01 19'-0" Ln N a --I X m x m 0 2X8SMB 19'-0" ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH # 12 SCREWS 6' FROM ENDS & 24" CENTER TO CENTER. # 10 SCREW 6' FROM ENDS & 12" CENTER TO CENETER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 7. 1 "X2" & 1 "X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. 8. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. i 16'-0"l \\\��1111111;;///////� \\ �\` a� / �N� o .pC� . �� o CD N C o IL 6 O J W C- _ co m '0/IIII11 111``\\\\\\ � 0 3" X .032" X 1LB COMPOSITE PANELS 3003-H154 �1/4"-1' SLOPE (MIN.) (FL.# 7561.1-R5 FOUNDATION DESIGN (1PSIW/ 1) POROPOS F BERMES" 24" ISOLATED FOOTERS W/ (3) #5 REBAR EACH WAY SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OR NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE 1 - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING +/- 1 %- ASTM C 260 iv. WATER REDUCING AGENT - ASTM C 494 v. CLEAN POTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM A 185 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. f. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE AREA FOR TERMITES IN COMPLIANCE WITH THE FBC. FOR RISK CATEGORY II, III, & IV STRUCTURES ONLY. g. CONCRETE SLAB SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. (SLAB ONLY) 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #4 X 8" REBAR INTO EX. FOUNDATION EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 6. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. COLUMN (SEE PAGE-2 FOR SIZE) FOR SURFACE MOUNT POST: SEE PROVIDED OPTIONS 24" X 24" X 24' ISOLATED CONCRETE FOOTING (3) #5 REBARS EACH (1) #5 REBAR THROUGH COL. WAY (6 TOTAL) 24" �(3) #5 REBARS EACH WAY (6 TOTAL) 24"x24"x24" ISOLATED FOOTING DETAIL SCALE: N.T.S. HOUSE WALL as i o N L.L0 6� W co�!/ o J _ LLI ate•• GV C7 W co ix H O 0 d� Z°� U> '> cn t c Q ui LLJ CONCRETE LEGEND HATCH INDICATES HOST/ EXIST. 0 NEW FOOTING - NEW SLAB AREA EXISTING RAFTER OR TRUSS C O #14x1/2"S.M.S.W/INTEGRAL 3/4"0 O C WASHER AND NEOPRENE GASKET @ 1 Z' O.C., TOP & BOTTOM EXTRUDED OR BRAKE -FORMED ROOF HEADER OR RECEIVING CHANNEL (0.044"MIN. THICKNESS) SECURE FASCIA TO EACH WITH MIN. 1-1 /Z' BEARING LEG. RAFTER TAIL W/ (1) 1 /4" 0 x 4" LONG PAN HEAD LAG SCREWS (1) 1 /4" 0 x Z' LAG SCREW @ 24" O.C. BEFORE ATTACHING REC. CHANNEL ENTIRE LENGTH OF RECEIVING CHANNEL ROOF PANEL ATTACHMENT - WOOD FRAME SCALE: N.T.S. :ARRIER BEAM SEE PAGE-2 OR SIZE) 1/8" DIA. MACHINE TS THRU CARRIER M & POST BEAM TO POST CONNECTION OPTION # 1 SCALE: N.T.S. 024 FLASHING SEALED TO -I/ WALL (TYP.) zov #14x1/Z'S.M.S.W/INTEGRAL 3/4-0WASHER AND NEOPRENE GASKET @ 12" O.C., TOP & BOTTOM. O IF CLEARANCE PROHIBITS INSTALLATION OF TOP FASTENERS USE #14x4"S.M.S. W/ 1-114' 0 FENDER WASHER AND NEOPRENE GASKET @ 12' O.C. Al \ EXTRUDED OR BRAKE -FORMED ROOF HEADER OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) WITH MIN. 1-1/2' BEARING LEG. HOST STRUCTURE 1/4" 0 x 2-1 /2" LONG WOOD LAG SCREW OR MASONRY OR WOOD 1/4" 0 x 2-1 /4" LONG MASONRY ANCHORS @ 24" O.C. MAX. ROOF PANEL ATTACHMENT - MASONRY SCALE: N.T.S. CARRIER BEAM (SEE PAGE-2 FOR SIZE) 3/8" DIA. MACHINE )LTS THRU CARRIER AM & POST BEAM TO POST CONNECTION OPTION #2 SCALE: N.T.S. (4) 1/4'k3-1/4"TAPCON THRU BOTTOM LEG OF ANGLE INTO CONC. (2) 3/8" DIA. MACHINE BOLTS w/ WASHERS 3-3/4" FROM EDG OF SLAB/ FTG. 44 MAY USE (3) #14xl"TEK TOP VIEW IN LIEU OF THRUBOLTS 3'x&' POST PER PLAN (2) 3/8" DIA. MACHINE BOLTS w/ WASHERS t /8'k2k3° (LENGTH) ANGLE (4) 1/4"6-1/4"TAPCON (INTERNAL) THRU BOTTOM LEG OF ANGLE INTO CONC. 3000 PSI CONC. - SLAB/FTG. 6x6-1Ox10 WWM ° OR FIBERMESH FRONT VIEW 3"x3" POST CONNECTION DETAIL (INTERNAL BASE) SCALE: N.T.S. ROOF PER PLAN # 14x4" S.M.S. w/ 1-1 /4" 0 FENDER WASHER AND NEO-PRENE GASKET @ 12' O.C. # 12 X 9/16" W/ 5/8" NEO-WASHER (3) PER PAN FOR PANS COVER END OF PANEL CARRIER BEAM (SEE PAGE-2 FOR SIZE) Lu `(2) 3/9-DIA. MACHINE BOLTS THRU CARRIER BEAM & POST `OPTIONAL EXTRUDED GUTTER IS ATTACHED TO 3" INSULATED ROOF POST W/# 12x1" 6" FROM ENDS 24" O.C. POST TO CARRIER BEAM CONNECTION SCALE: N.T.S. ROOF PER PLAN # 14x4" S.M.S. w/ 1-1 /4" O FENDER WASHER AND NEO-PRENE GASKET @ 12' O.C. # 12 X 9/16" W/ 5/8" NEO-WASHER (3) PER PAN FOR PANS COVER END OF PANEL 3"XZ'X.050"MIN. (SEE PLAN) ROOF PANEL TO CARRIER BEAM CONNECTION SCALE: N.T.S. 2'XZ X.125' ANGLE W/ #14x3/4"THRU ANGLE LEG `INTO BEAM EA. SIDE TYP. / SEE TABLE FOR QUANTITY �2"XZ'X.125" ANGLE W/ (3) 114" X 2-1/4" TAPCONS @ Z' o.c. THRU ANGLE LEG INTO HOST WALL 3 / TOP VIEW w U H F- 0 BEAM PER PLAN (2X7SMB ILLUSTRATED) 0 Z'XZ'X.125" ANGLE W/ 0 #14x3/4"THRU ANGLE LEG INTO BEAM EA. SIDE TYP. 0 SEE TABLE FOR QUANTITY N O i Z'XZ'X.125" ANGLE W/ 2 (3) 1 /4" X 2-1/4" TAPCONS @ 2' o.c. THRU ANGLE LEG INTO HOST WALL SIDE VIEW BEAM TO HOST WALL CONNECTION SCALE: N.T.S. 04 ........... _N 4(0 �Z:c4D o O O J a N :Z o U cmI. Lu �:Q_ c Lu Deco" FASTENER NOTES: MAINTAIN 1/2"SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8" MIN, FASTENER SEPARATION FROM EDGE. FASTENERS MAY BE STAGGERED TO ENSURE PROPER QUANTITY PERMITTED (PATTERN MAY APPEAR DIFFERENT FROM ILUSTRATION) BEAM TO WALL W/ 1/8" ANGLE TABLE BEAM SIZE QUANTITY/ SIZE PER LEG TO BEAM QUANTITY ANCHOR PER LEG TO WALL 2X4 (4) #12 - (2) #16 (2) 1 /4" TAPCON 2X5 (5) #12- (3) #16 (2) 1/4"TAPCON 2X6 (5) #12- (3) #16 (3) 1/4"TAPCON 2X7 (6) #14- (4) #16 (3) 1/4"TAPCON 2X8 (7) #14-(4) #16 (4) 1/4"TAPCON 2X9 (8) #14- (5) #16 (4) 1/4"TAPCON 2X10 (9) #14-(6) #16 (5) 1/4"TAPCON FOR WOOD APPLICATION IN LIEU OF MASONRY ANCHORS USE: 1/4" X 3" GALV. LAGS (4)3/8"x4"TAPCONTHRU MAY USE: (4) 3/8"x5"TAPCON BOTTOM LEG OF ANGLE IN LIEU OF 1 /2" DIA. BOLTS MAY USE: (2) 3/8"x4" TAPCON INTO CONC. F, (2) 1/2' DIA. EXPANSION BOLTS (3) 1/4" DIA. MACHINE IN LIEU OF 3/8" DIA. BOLTS SEE NOTE #2 THIS PAGE (2) 3/8" DIA. EXPANSION BOLTS (3) 1/4"DIA. MACHINE ® ® BOLTS w/ WASHERS (2) BOLTS DIA. MACHINE BOLTS w/ WASHERS 7' FOR BOLT PLACEMENT SEE NOTE # 1 THIS PAGE BOLTS w/ WASHERS FOR BOLT PLACEMENT ® Z' FROM EDGE Z' FROM EDGE OF SLAB/ FTG. OF SLAB/ FROM EDG 1" OF SLAB/ FROM EDGE OF SLAB/ FTG. OF SLAB/ FTG. OF SLAB/ FROM EDGE-1OF SLAB/ FTG. OF SLAB/ FTG. TOP VIEW MAY USE (4) #14xl"TEK TOP VIEW (3) 1/4"DIA. MACHINE (2) 3/8" DIA. MACHINE IN LIEU OF THRUBOLTS BOLTS w/ WASHERS TOP VIEW BOLTS w/ WASHERS 3"x3" POST COLUMN PER PLAN 4'k4" POST (SEE PAGE-2 (3) 1 /4"DIA. MACHINE (SEE PAGE-2 (2) 3/8" DIA. EXPANSION BOLTS FOR SIZE) BOLTS w/ WASHERS 12) 1/2' DIA. EXPANSION f FOR SIZE) SEE NOTE #1 THIS PAGE BOLTS SEE NOTE #2 FOR BOLT PLACEMENT I/8'k2'kKn3-3/4" THIS PAGE FOR BOLT LN Y USE 4 # 14x1 TEK MAY USE (3) #14x1"TEK (LENGTH) ANGLE PLACEMENT ( ) IN LIEU OF THRUBOLTS (4) 3/8'k4"TAPCON (INTERNAL) LIEU OF THRUBOLTS THRU BOTTOM LEG 3'k3'k0.125 ANGLE OF ANGLE INTO CONC. 2NNNO.125 ANGLE 3000 PSI CONC. ° e 3000 PSI CONC. ° " 3000 PSI CONC. SLAB/ FTG. SLAB/ FTG. SLAB/ FTG. ° 6x6-1Ox10 WWM 6x6-10x10 WWM 6x6-1Ox10 WWM OR FIBERMESH OR FIBERMESH OR FIBERMESH FRONT VIEW FRONT VIEW FRONT VIEW 3"x3" POST CONNECTION DETAIL 4X4 COLUMN ALT. BASE ATTACHMENT 4"x4" POST CONNECTION DETAIL SCALE: NTS DETAIL SCALE: NTS SCALE: NTS U � J c:) N Lo J rn co M z z o O L1. p U LuJO05�, LU < J 01) LL Lo Z ~_F-Mc LIJ 0 (U UI Z w Q O J G r 0 � J O CL LL Z_ _J in O U O Lu OQ<, J r Co z O 0 DESIGN DATE: REVISION 1: REVISION 2: DRAWN BY: SCALE: N 00 r- 0 m �i LU C) 0 w rn N CO O T_ N Y W W Q' J UW LU W uj W J W o U�F- 0 Qco0 LLJ (n I— D- O 0: a 02/16/2021 03/23/2021 DATE I SHEET: 04 NTT S