HomeMy WebLinkAboutFord revised plans with larger deckMIN. VERTICAL:2'-3" SHALLOW END3'-8" DEEP END#3 BARS @ 12" O.C. E.W. CENTERED IN CONCRETE PLASTER FINISH, GEM COAT OR EQUIVALENT 6" 6" WATERLINE TILE R 8" 8" 4" THICK CONCRETE SLAB 6x6 - W1.4/W1.4 WWM OR FIBERMESH W/ EXISTING SOILS COMPACTED TO 95% MAX. COMPACTIONDECK WIDTH VARIES #5 BAR W/ OVERLAP AT END OF REBAR 1:3 MAX. SLOPE STEEL TEX. OR EQUIVALENT WIDTH VARIES FROM 4" - 6" NOTES:1.)IF NO SCREEN ENCLOSURE IS PROPOSED NO FOOTER IS REQUIRED, HOWEVER, SLOPE SHALL BE STARTED 2 FEET FROM EDGE OF PAVEMENT 2.)FOOTER SHOWN IS SUFFICIENT FOR STANDARD SINGLE STORY SCREEN ENCLOSURE. ALTERNATE DESIGNS, INCLUDING BUT NOT LIMITED TO NO FOOTER REQUIRED, PROVIDED BY ENGINEER FOR SCREEN ENCLOSURE SHALL TAKE PRECEDENCE OVER THIS DESIGN. 3.) PAVERS MAY BE SUBSTITUTED FOR CONCRETE DECK. HOWEVER, FOOTER MUST STILL BE CONCRETE IN DIMENSIONS AND REINFORCEMENTS DEPICTED 4.) WALLS OVER 6' IN HEIGHT SHALL BE REINFORCED PER WALL OPTIONS TABLE BELOW 2- #3 BARS AT TOP TIED TO VERT. STEEL 11° SLOPE MAX. (TYP.)11° SLOPE MAX. (TYP.)MAIN DRAIN LOCATION WATER LINE 1 3 MAX. 1 7 18'-0"2'-0" 3'-6" 5'-0" 20'-0"1-1/2" TO AUX.POOL JETS1-1/2" TO AUX.POOL JETS1-1/2" TO AUX.FLOOR RETURN1-1/2" TOACCESSORYFILTER SYSTEM W/ PRESSURE GAGE AND AIR RELEASE VALVE MAIN RETURN LINE POOL 2" SKIMMER POOL DRAINS2.5" SCH.40 PVC1-1/2" CLEANERLINEPUMP WITH HAIR AND LINT STRAINER (SEE ATTACHED CALCULATIONS) WASTE (RETAIN ON SITE) CHECK VALVE 2-WAY VALVE FLOW DIRECTION LEGEND 8" MIN. 48" MIN. 18" MIN. JUNCTION BOX WATER LINE 12V LIGHT W/ LOW WATER CUTOFF DEVICE POOL WALL AND DECK (SEE TYPICAL SECTION) TO ELEC. SERVICE VIA WATER PROOF G.F.I. NO MORE THAN 20' FROM POOL EDGE AND NOT WITHIN 10' OF POOL EDGE PANEL TO PUMP TO PUMP 2 (IF APPLICABLE) TO BLOWER (IF APPLICABLE) TO HEATER (IF APPLICABLE) 12V TRANS. SPST TOGGLE SWITCH 3 #8 WIRES IN 1" CONDUIT 3 - #12 WIRES IN 3/4" CONDUIT 3 - #12 WIRES IN 3/4" CONDUIT 1" NON-CORROSIVE CONDUIT WP MANUAL STARTER SWITCH (TYP.) POOL DECK 6" MAX. 18"-24"MIN. FOUR (4) CONNECTIONS (ONE EACH SIDE) W/ #8 BARE AWG COPPER W/ APPROVED CLAMPS MIN. #8 BARE AWG COPPER AROUND PERIMETER OF POOL CONNECT PERIMETER GROUND WIRE TO GROUND SYSTEM STAINLESS STEEL HANDRAIL (SAME BONDING FOR LADDER) CONNECT #8 BARE AWG COPPER WITH APPROVED BOND CLAMP CONNECT #8 BARE AWG COPPER WITH APPROVED BOND CLAMP LIGHT NICHE NOTE: BONDING PER 250.8 AND 680.26(B) OF NFPA 70, NATIONAL ELECTRICAL CODE. GRATE TO BE ATTACHED WITH SCREWS WELL POINT THREADED PVC PIPE 3/4" ROCK BED (MIN 3YDS. ROCK TO STABILIZE SOIL) HYDROSTATIC LINE (1-1/2") REMOVE GRATE AND WELL POINT LINE FROM MAIN DRAIN, AND ATTACH AUX. PUMP LINE WHEN EMPTYING ANGLE OF REPOSE = 1.5:1 0' - 3' 3' - 6' 6' - 9' 8" THICK WALL W/ #3 BARS @ 6" O.C.E.W. 6" THICK WALL W/ #3 REBAR @ 12" O.C.E.W. 5" THICK WALL W/ #3 REBAR @ 12" O.C.E.W. 3' NOTE: SEE TYPICAL WALL SECTION WHEN WALL FALLS OUTSIDE OF THE ANGLE OF REPOSE SEE TYPICAL WALL SECTION FOR REINFORCEMENT 12" MAX. 18"12" MIN.12" MIN. 12" MAX. 12" MAX. NOTE: ALL STAIRS SHALL BE UNIFORM IN HEIGHT EXCEPT FOR THE TOP AND BOTTOM RISE WHICH MAY VARY FROM THE UNIFORM HEIGHT. 18" 18" POOL DECK WATER LINE BEAM OPTIONAL SINGLE CONNECTION OR HYDROSTATIC VALVE SINGLE PIPE CONNECTION ON ANY OF THREE PORTS. 1-1/2". 2", 2-1/2". 3" OR GREATER PIPE PLUG PORTS NOT BEING USED GRAVEL TO PUMP FRAME / MUD-RINGINTERIOR POOL FINISH SHOTCRETE/GUNNITE EARTH LONGITUDINAL POOL SECTION PLUMBING DIAGRAM ELECTRICAL DIAGRAM N.T.S. N.T.S. N.T.S. N.T.S. EQUIPOTENTIAL BONDING GRID DETAIL N.T.S. TYPICAL WALL AND DECK SECTION (MAX. 6' HEIGHT) ALTERNATE WALL OPTIONS (WALL HEIGHT GREATER THAN 6') N.T.S. VERT. REINFORCEMENT #3 BARS @ 12" O.C. REQ. WALL THICKNESS HORIZ. REINFORCEMENT #3 BARS @ 9" O.C. #3 BARS @ 6" O.C. #3 BARS @ 3" O.C. MAXIMUM WALL HEIGHTS N/A N/A N/A N/A N/A 6' - 6" 7' - 6" 7' - 0" 8' - 0" 6' - 6" 7' - 6" 8' - 6" 6' - 6" 7' - 0" 8' - 0" 9' - 0" #3 BARS @ 12" O.C.#3 BARS @ 12" O.C.#3 BARS @ 9" O.C.#3 BARS @ 6" O.C. 4" THICK 5" THICK 6" THICK 8" THICK NOTE: PIPE SIZING TO BE DETERMINED BY HYDRAULIC CALCULATIONS POOL LAYOUT SCALE: 1/4" = 1' REQUIREMENTS APPLY TO EXISTING POOL REPLACEMENTS/ADDITIONS AND NEW CONSTRUCTION DOESN'T APPLY TO COMMERCIAL POOLS IS THE PUMP MOTOR USED TO FILTER WATER? CANNOT BE SPLIT-PHASE, SHADED POLE OR CAPACITOR START-INDUCTION TYPES DOESN'T APPLY TO CIRCULATION WITHOUT FILTRATION IS THE TOTAL HORESPOWER ONE OR LARGER? TOTAL HP = PUMP HP x SERVICE FACTOR ALSO FOLLOW THESE REQUIREMENTS: - PUMP AND PUMP MOTORS MUST BE TWO OR MORE SPEEDS. -CONTROLS NED TO BE CAPABLE OF OPERATING AT A MINIMUM OF TWO SPEEDS. -DEFAULT CIRCULATION MUST BE THE RESIDENTIAL FILTRATION SPEED. THE HIGHER SPEED OVERRIDE IS NOT TO EXCEED ONE NORMAL CYCLE OR 24 HOURS, WHICHEVER IS LESS. -SOLAR POOL HEATING SYSTEMS ARE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE HEAT GAIN. SINGLE SPPED PUMP PERMITTED. ADDITIONAL REQUIREMENTS MAY APPLY CONTINUE ON. IS THIS NEW CONSTRUCTION? ADDITIONAL REQUIREMENTS PER APSP-15:. -SIZE THE PUMP BASED ON: --POOL GALLONS / 360 MIN. AND SELECTING PUMP FROM DATABASE WITH CURVE A OR C LISTED FLOWRATE EQUAL TO OR LESS THAN CIRCULATED FILTRATION FLOWRATE. -A TIME SWITCH MUST BE INSTALLED TO ALLOW POOL OWNERS TO RUN THE POOL FILTRATION PUMP ONLY DURING THE OFF-PEAK PERIOD AND FOR THE MINIMUM TIME NECESSARY TO MAINTAIN THE WATER IN THE CONDITION REQUIRED BY APPLICABLE PUBLIC HEALTH STANDARDS. -FILTERS MUST HAVE A MINIMUM AREA BASED ON THE 6 HOUR TURNOVER FLOW RATE. --POOL GAL. / 360 MIN. = FLOW RATE (IN GPM) --DIVIDE GPM BY A NUMBER SHOWN TO FIND THE FILTER'S MIN. SQUARE FOOTAGE. (CARTRIDGE = .375, SAND = 15, DE = 2) -MIN. DIAMETER OF BACKWASH VALVES MUST BE TWO INCHES OR THE DIAMETER OF THE RETURN PIPE WHICHEVER IS GREATER. -SWEEP ELBOWS ARE RECOMMENDED. -(REMEMBER: RESIZE PIPING SO VELOCITY AT MAX FLOW DOES NOT EXCEED 8 FPS IN THE SUCTION LINE AND 6 FPS IN THE SUCTION LINE, AND ALSO MEETS VGB/ANSI-7 ENTRAPMENT AVOIDANCE REQUIREMENTS.) NO ADDITIONAL REQUIREMENTS ARE IN PLACEYESNOYESNO YES NO YES NO NOTE: LAYOUT PROVIDED BY CONTRACTOR NOTE: SEE ATTACHED HYDRAULIC CALCULATIONS FOR ADDITIONAL DETAILS REGARDING PUMP FLOW RATES AND TOTAL DYNAMIC HEAD CALCULATIONS. SELECTED EQUIPMENT CALCULATIONS N.T.S. Pipe Size 8 fps (in.)GPM Loss (ft/ft) 2.0 82 0.10 2.5 117 0.09 3.0 181 0.07 WELLPOINT N.T.S. POOL PUMP CURVE POOL EQUIPMENT POOL RETURN PIPING POOL TRUNK PIPING GENERAL NOTES 1.ALL FLOORS AND WALLS OF POOL TO BE CONSTRUCTED USING PNEUMATICALLY APPLIED CONCRETE WITH 28 DAY STRENGTH OF 2500 PSI. 2.REINFORCING STEEL SHALL CONFORM TO A.S.T.M. 615 GRADE 60 3.PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL. 4.POOLS TO BE CONSTRUCTED ONLY ON CLEAN SAND OR ROCK. SOILS IN FINAL BACKFILL SHALL BE COMPACTED TO PROVIDE A MINIMUM BEARING CAPACITY OF 1000 PSF. ALL UNSUITABLE MATERIALS SHALL BE REMOVED AND REPLACED WITH CLEAN SAND PLACED AND COMPACTED IN 12" LIFTS. 5.ALL BACKFILL SHALL BE PLACED WITH CARE IN ORDER TO ENSURE THAT PLUMBING IS NOT DISTURBED. ALL FILL SHALL BE CLEAN SAND PLACED IN 12" LIFTS AND COMPACTED TO 98% OF MAXIMUM DENSITY. 6.THE CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS IN ORDER TO PROTECT EXISTING STRUCTURES AFFECTED BY THE CONSTRUCTION. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. 7.ENGINEERING PLOT PLANS WERE NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES WHEN NECESSARY. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. AS SUCH, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS. 8.CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES ON SITE AND SHALL MAINTAIN MINIMUM SEPARATIONS AS REQUIRED BY LOCAL REGULATIONS. GENERALLY, ELECTRICAL LINES SHALL BE A MINIMUM OF 10 FEET FROM OPEN WATER. 9.ALL UNSCREENED POOLS SHALL HAVE A FENCE A MINIMUM OF 4 FEET IN HEIGHT WITH SELF-LOCKING GATES. 10.WHERE POOLS ABUT OR ARE PLACED NEAR SEAWALLS OR BULKHEADS SPECIAL CARE SHOULD BE TAKEN. NOTIFY ENGINEER OF THIS CONDITION FOR ANALYSIS AND RE-DESIGN IF NECESSARY. 11.PATIO DESIGN MAY BE NOTED TO BE COMPLETED BY OTHERS. WHEN NOTED, ANY DETAILS REFERRING TO PATIO DESIGN ARE NOT APPLICABLE. THE TYPICAL WALL SECTIONS OF POOL ARE NOT APPLICABLE TO PAVEMENT DESIGN. 12.VACUUM LINE SHALL INCLUDE A SPRING LOADED SELF CLOSING COVER. 13.THE SWIMMING POOL HAS BEEN DESIGNED TO BE COMPLIANT WITH THE 2017 FLORIDA BUILDING CODE 6TH EDITION, AS WELL AS THE 2014 NATIONAL ELECTRIC CODE, ANSI/APSP-7, AND SHALL BE ANSI 15 COMPLIANT. 14.BASE MATERIAL THICKNESS MUST BE 125% OF CONCRETE FASTENER EMBEDMENT. 15.HOMEOWNER MUST BE AWARE OF THE POSSIBILITY OF EROSION AND SHALL BE RESPONSIBLE FOR MAINTENANCE IN ORDER TO PREVENT FAILURE. 16.WATER VELOCITY MAXIMUM 8 FT/SEC AS PER FBC 2017-R4501.6.3 17.POOL BARRIER TO COMPLY WITH FBC 2017-R4501.17 18.SKIMMERS TO COMPLY WITH FBC 2017-4501.21.2 19.EQUIPMENT FOUNDATION CONCRETE SLAB, MIN. 3.5" THICK, POUR IN PLACE. 20.WATER HEATING EQUIPMENT TO COMPLY WITH FBC 2017-R4501 21.ALL DECK AND SLAB CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 P.S.I. IN 28 DAYS UNLESS OTHERWISE NOTED. 2014 NEC POOL PUMP ENERGY EFFICIENCY REQUIREMENTS IS IT A RESIDENTIAL POOL? (NOT A SPA) SAFETY NOTES 1.NO DIVING BOARD OR DIVING IS ALLOWED IN ANY POOL WITH A DEPTH LESS THAN 8'-8" AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL DOES NOT CONFORM TO THESE REQUIREMENTS AND NO DIVING SHALL BE PERMITTED 2.THIS POOL TO BE EQUIPPED WITH _______ CHILD SAFETY FENCE AROUND THE PERIMETER OF THE POOL OR __ ____ ALARMS AT THE ENTRANCES TO THE POOL (ONE TO BE CHECKED). ANGLE OF REPOSE N.T.S. STAIRS DETAIL N.T.S. SWIMOUT DEPTH DETAIL N.T.S. CHANNEL DRAIN INSTALLATION DETAIL N.T.S. CUSTOM MOLDED PRODUCTS 32" CHANNEL DRAIN VGB-2009 COMPLIANT - MODEL: CMP 25506-32X NOTE: THE MAXIMUM FLOW RATING FOR THIS SUCTION FITTING AS CONFIGURED WITH OUTER PORTS PLUGGED AND CENTER PORT OPEN IS 200 GPM (FLOOR) WHEN USING 2.5" PLUMBING AND 184 GPM WHEN USING 2" PLUMBING. NOTE: 2.5" (POOL) CONNECTION ON THIS INSTALLATION ENGINEERING DESIGN, LLC. 4727 N. Hwy A1A Phone: (772) 226-0224 Vero Beach, FL 32963 E-Mail: rpengdesignllc@gmail.comCLINTON J. RAHJES, P.E.DATE FL. LICENSE No. 70170 L.B./C.O.A. No. 29080 PROJ. NO.: DATE: 7N0170o. T TAE OFSFLORID ALIC E N SECLINTON J.RAHJ ESPROFESSIONA L E N GINEER11/3/20 20-83 PIPELINE POOL AND PAVERS, INC. FORD RESIDENTIAL POOL 7705 LOCKWOOD DR FORT PIERCE, FL 34951 POOL LAYOUT AND DETAILS SHEET 1 OF 1 6/23/21 Rev. 1: Revised pool deck layout per contractor and added footer for future screen enclosure. 6/22/21