Loading...
HomeMy WebLinkAboutCompaction Test � C1t JML_Jiva KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN(772)337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN(772)589-0712 PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093 C.A.: 5693 FAX(772)589-6469 April 5, 2019 Drew Dunlap Dunlap Construction Group LLC 1708 Old Dixie Highway Vero Beach, Florida 32960 Re: Ocean Resorts 5101 Highway A1A Fort Pierce, Florida aoo Permit#: 1812-0035 1a_Uy KSM Project#: 190553-2d Dear Mr. Dunlap: Enclosed, please find the nuclear density test results performed on the footer pads for the club house repair at the above referenced project. tf t7lif / Sal�otlfcyoiVr�,any questions, please feel free to contact us. RECEIVED N t .o d JUN 0 8 2021 r • ♦♦ •re JEI�Lt�l+ll/tt�k a` E-mail to: drewdunlap@dunlap-construction.com Fax and Mail to: St. Lucie County Building Department Ronald G. Keller, P.E.:37293/SI Lic. No.:860 / Julie E. Keller, P.E.:68366 � C1t A%L_L7iva KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN(772)337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN(772)589-0712 PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772) 229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED: April 4th, 2019 KSM JOB #: 190553-2d/SS/ct PERMIT #: 1812-0035 CONTRACTOR: Dunlap Construction Group LLC JOB LOCATION: Ocean Resorts 5101 Highway A1A Fort Pierce, Florida MATERIAL: Fine Tan Sand ITEM TESTED: Footer Pads for the Club House Repair - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - TEST DEPTH MOIS- PEN DRY MAX. DRY PERCENT LOCATION TURE READ DENSITY PROCTOR COMPACTION VALUE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1. North 0" — 12" 7.3 43 105.7 106.0 99.7 2. N. Center 19 1140 103.9 it98.0 3. S. Center 42 104.4 it98.5 4. South it it43 105.1 1199.2 Ronald G. Keller, P.E.: 37293/SI Lic. No.: 860 / Julie E. Keller, P.E.:68366 L%17 JLVL KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN(772)337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN(772)589-0712 PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 MOISTURE-DENSITY RELATIONSHIP MODIFIED PROCTOR (ASTM D 1557) DATE TESTED: April 4th, 2019 KSM JOB #: 190553-2p PERMIT #: 1812-0035 CONTRACTOR: Dunlap Construction Group LLC JOB LOCATION: Ocean Resorts 5101 Highway A1A Fort Pierce, Florida 107 T - - T - - 7 - - -1- - -I- - - r - - T - - -T - - � I I I I I I I I I I I I I I I I I I 106L _ _ 1 _ _ 1 _ _ J_ _ _I_ _ 1 _ _ 1 _ _ J I I I I I I I I I 105 -t- - - f - - -t - - -j- - I- - - + - � - - -{ U I I I I I I I I I a I I I I I I I I w I 1 I I I I I I 103 � - - � - - - - - - -1- - - - - - - -� - - � I 1 I I I I I I I I I I I I I I I I I I I I I I I I 102 T- - - T- - - T - - -1- - -1- - - r - - T - - -t - - -1 I I I I I I I I I I I I I i I I I I 101 - - �- - - - - - - - - - - - - - - � - - � 7 8 9 10 11 12 13 14 15 Moisture- Percent of Dry Weight Soil Description: Fine Tan Sand Max. Dry Density: 106.0 P.C.F. Optimum Moisture: 12.0 Percent Julie E. Keller, P.E. President Ronald G. Keller, P.E.:37293/SI Lic. No.: 860 / Julie E. Keller, P.E.:68366