Loading...
HomeMy WebLinkAbout211011-1d Compaction - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net February 8, 2021 KSM JOB # :211011-1d/SH/jo CONTRACTOR:South Florida Land Clearing 15701 Orange Avenue Fort Pierce, Florida JOB LOCATION:Mueller Road Fort Pierce, Florida PERMIT #: To Whom it may concern, Should you have any question, please feel free to contact our office. Respectfully, Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 02/08/21 Email to: sflcgw@gmail.com Enclosed, please find the nuclear density test results performed on the main house compacted foundation fill at the above referenced project. Proudly Serving Florida since 1990 Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB # :211011-1d/SH/jo NUC #456 South Florida Land Clearing Nuc Model:MC-1 Elite Mueller Road Nuc Serial #:31456 Fort Pierce, Florida Compacted Foundation Fill #TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F.) PERCENT COMPACTION Main House 1 N.E.0" - 12"41 110.3 113.3 97.4% 2 S.E."43 112.3 "99.1% 3 Center "44 112.7 "99.5% 4 S.W."42 111.6 "98.5% 5 N.W."43 111.7 "98.6% Proctor Optimum Moisture: @ Test Locations the Density & 2/8/2021 Proudly Serving Florida since 1990 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test.KSM is not responsible if the tested area has been altered from the approved inspected condition. 113.3 Penetrometer reading indicate the for Unstaked Foundation Bryan E. Dahlke, P.E. V.P. of Engineering SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 Soil Description: Yellow Shelled Sand with Clay In Place Moisture: Proctor Max. Dry Density: P.C.F. 12.0% 8.6% February 5, 2021 PE # 81439 DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: ITEM TESTED: Degree of Compaction Meets Minimum Requirement Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB # :211011-1d/SH/jo PERMIT #: CONTRACTOR:South Florida Land Clearing JOB LOCATION:Mueller Road Fort Pierce, Florida Soil Description: Yellow Shelled Sand with Clay Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 113.3 Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 2/8/2021 SOIL COMPACTION REPORT ASTM D 1557 Proudly Serving Florida since 1990 February 5, 2021 108.0 109.0 110.0 111.0 112.0 113.0 114.0 115.0 7 8 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight