February 8, 2021 KSM JOB # :211011-1d/SH/jo
CONTRACTOR:South Florida Land Clearing
15701 Orange Avenue
Fort Pierce, Florida
JOB LOCATION:Mueller Road
Fort Pierce, Florida
PERMIT #:
To Whom it may concern,
Should you have any question, please feel free to contact our office.
Respectfully,
Bryan E. Dahlke, P.E.
V.P. of Engineering
PE # 81439 02/08/21
Email to: sflcgw@gmail.com
Enclosed, please find the nuclear density test results performed on the main house compacted foundation fill at
the above referenced project.
Proudly Serving Florida since 1990
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB # :211011-1d/SH/jo
NUC #456
South Florida Land Clearing Nuc Model:MC-1 Elite
Mueller Road Nuc Serial #:31456
Fort Pierce, Florida
Compacted Foundation Fill
#TEST LOCATION
OF SAMPLE DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F.)
PERCENT
COMPACTION
Main House
1 N.E.0" - 12"41 110.3 113.3 97.4%
2 S.E."43 112.3 "99.1%
3 Center "44 112.7 "99.5%
4 S.W."42 111.6 "98.5%
5 N.W."43 111.7 "98.6%
Proctor Optimum Moisture:
@ Test Locations the Density &
2/8/2021
Proudly Serving Florida since 1990
Disclaimer:Contractor is responsible to
maintain the tested area in the condition that
KSM completed the indicated passed
compaction test.KSM is not responsible if the
tested area has been altered from the approved
inspected condition.
113.3
Penetrometer reading indicate the
for Unstaked Foundation
Bryan E. Dahlke, P.E.
V.P. of Engineering
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
Soil Description:
Yellow Shelled Sand
with Clay
In Place Moisture:
Proctor Max. Dry Density: P.C.F.
12.0%
8.6%
February 5, 2021
PE # 81439
DATE TESTED:
PERMIT #:
CONTRACTOR:
JOB LOCATION:
ITEM TESTED:
Degree of Compaction Meets
Minimum Requirement
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:KSM JOB # :211011-1d/SH/jo
PERMIT #:
CONTRACTOR:South Florida Land Clearing
JOB LOCATION:Mueller Road
Fort Pierce, Florida
Soil Description:
Yellow Shelled Sand
with Clay
Proctor Optimum Moisture:
12.0%
Proctor Max. Dry Density: P.C.F.
113.3
Bryan E. Dahlke, P.E.
V.P. of Engineering
PE # 81439 2/8/2021
SOIL COMPACTION REPORT
ASTM D 1557
Proudly Serving Florida since 1990
February 5, 2021
108.0
109.0
110.0
111.0
112.0
113.0
114.0
115.0
7 8 9 10 11 12 13 14 15
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight