Loading...
HomeMy WebLinkAboutAPPROVED design pressure calcsPARADISEEXTERILORS "Building Our QualityReputation One Customer At A Time SCC131150472 Property Information Building Information Owner: SUSAN MCMAHON Wind Zone: 170 MPH. Address: 8006 LAI ELAND BLVD Exposure Category: C FORT PIERCE, FL 34951 Minimum Building Dimension: 32 ft. Mean Roof Height: 12 ft. Risk Category: It Design Pressure Calculations Openings m Location Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psfl Pressure (psi I Int 37 81 7 36.0 -39, 2 2 Int - 23 60 7 37.8 -41.0 3 Int 49 60 7 36.0 -39.2 4 Int 23 60 7 _ 37.8 -41.0 5 End 72 61 7 35.1 -45.1 6 Int 72 61 7 35.1 -38.3 7 11-it 35 -- 36- 7 37.8 41.0 8 Int 74 80 7 34.3 -3 T 5 9 End 71 80 7 34.4 -43.9 10 End 24 36 7 37.8 -50.6 11 Int 35 36 7 37.8 -41.0 12 Int 33 80 7 36.3 -39.5 Prepared in accardcurce with: ASCI: 7-1 G, Chapter 30. Wind Loads - Components and Cladding. 7tk Edition (2020) Florida Building Cade. Page I of 1