HomeMy WebLinkAboutAPPROVED Design Pressure Report (Sparky Aldridge) - Master Craft Aluminum ProductsProperty Information Owner:Sparky Aldridge Address:8291 Red Cedar Dr Port St Lucie, Fl 34952 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:30 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 36 62 7 31.6 -34.3 2 Int 73 62 7 30.1 -32.8 3 Int 36 120 7 29.9 -32.7 4 Int 73 62 7 30.1 -32.8 5 Int 38 62 7 31.4 -34.2 6 Int 53 62 7 30.7 -33.5 7 Int 36 62 7 31.6 -34.3 8 Int 53 62 7 30.7 -33.5 9 Int 36 80 7 31.0 -33.8 10 Int 62 80 7 29.9 -32.6 11 Int 74 62 7 30.0 -32.8 12 Int 53 62 7 30.7 -33.5 13 Int 36 49 7 32.1 -34.8 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1