HomeMy WebLinkAboutAPPROVED Plan- page 2 of 2H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
MAX. WIDTH:
MIN. DEPTH:
15'
SHAPE:
FILL FROM EXCAVATION:
TILE:FILTER:
PUMP HP:
LIGHTS:
TRNFORM:
MAIN DRAIN:
SKIMMER:
RETURNS:
VALVED VAC LINE:
DISCHARGE LINE:
CHLORINATOR:
HANDRAIL:
DIVING BOARD:
HEATER:
VACUUM HEAD:
VACUUM HOSE:
LEAF SKIMMER:
TREE / STUMP REMOVAL:
REMOVE EXISITING CONCRETE:
PUMP POOL PATIO:
ELECTRICAL:
POOL PATIO:
EXISTING PATIO:
DECK DRAIN:
POOL CAPACITY:
TURN-OVER RATE:
TERMITE TREAT:BARRIER:
MAX. LENGTH:43'4"
3'MAX. DEPTH:6'
CUST
STOCKPILE
ELEVATION:TBD
INTERIOR FINISH:GEM CS200
POOL SPA
POOL 5 COLOR LED SPA 1
POOL SPA
POOL 1 SPA 1
2
POOL 4 SPA 2
JETS:POOL NA SPA 8
INCL FILL LINE:INCL
TO GROUND
AP 1400 SALT
NA LADDER:NA
NA SLIDE:NA
THERMEAU TH 140
INCL
INCL
INCL
POLE:
BRUSH:
TEST KIT:
INCL
INCL
INCL
NA
NA
SCREEN ENCLOSURE:
EDS ELECTRIC
TRAVERTINE BY TAURUS
INCL.
6-HRS.
INCL FENCE
NA
MAX. WATER VELOCITY:
MIN. SKIMMER FLOW:
SURFACE AREA OF POOL:
SPECIFICATIONS
2HP PHPM
300 W 100 W
TRAVERTINE OVERLAY
PUMP MAKE PER FBC 4501.20
1.5HP VS JEP
FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011
AARON H. ALLEN PE, FL REG. NO. 86620 FL
A. ALLEN ENGINEERING LLC, CA NO. 33042
2367 7TH STREET, LA VERNE, CA 91750
TO THE BEST OF MY KNOWLEDGE, THESE
DRAWINGS AND SPECIFICATIONS COMPLY WITH
THE APPLICABLE MINIMUM BUILDING CODES
18,999-GAL.
SPA CAPACITY:898-GAL
6 FPS FROM TRUNK
25 GPM
635 SQFT.
PERIMETER OF POOL: 112 LINFT
SEAL:
BUILDER/JOB NAME:
PERMIT NO.:
DATE DRAWN:
TBD
03/04/2021
DRAWN BY:
CHECKED BY:
APPROVED BY:
MELVILLE
ADDRESS:7827 SABAL LAKE DR
JASON BARAN
AARON H. ALLEN
SCALE:¼” = 1'
CITY:PORT ST LUCIE, FL
JOB INFORMATION
BY PIONEER
SECTION THRU POOL 1
AScale: NTS
MAIN DRAIN
SKIMMER
COLOR LED
VACUUM LINE
SYMBOL LEGEND
DECO DRAIN
EXISTING FACILITY CHANNEL
DRAIN
ELEVATION MARKER
B BUBBLER
JANDY UPLIGHTUL
DOOR/WINDOW ALARM
BABY BARRIER
XX.X’
x
0 ft.2 ft. 4.8 in.4 ft.8 ft.
REVISION DATE:NA
· APPROVED WITH THE 2020 FLORIDA BUILDING CODE FOR
RESIDENTIAL 7TH EDITION AND THE ANSI/APSP-7 2013 FOR
SUCTION ENTRAPMENT AVOIDANCE
TO 8FPS SUCTION LINES,10FPS MAX RETURN
8880 GLADES CUT OFF ROAD
PORT ST. LUCIE, FL 34986
CUSTOMER APPROVAL:
REVISION
VERIFY EXACT
LOCATION OF EQ PAD
WITH KOLTER FIELD
SUPERVISOR
30" CLEARANCE IN
FRONT
OF SUBPANEL
EQ. LAYOUTNO SCALE
F
P2
P1
HE
SALT
BURIED POWER
LINES
*LOCATION OF GFI
RECEPTACLE
TO BE DETERMINED IN
FIELD PER NEC 680
43'4"
0
FLOOR SLOPES
#3 STEEL @ 12" O/C E.W.
WATERLINE TILE
MAIN DRAIN
12'
6"
6'
3'
4-½”
10" MIN.
STEP NOTES:
1. TREAD IS MIN. OF 10" WIDE.
2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED.
3. ALL STEPS TO BE SOLID GUNITE 4000 PSI.
4. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER
OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY
NOTES:
1. (5.6.1) THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1
FOOT IN 7 FEET TO THE POINT OF THE FIRST SLOPE CHANGE
2. (5.6.2) CHANGES IN SLOPE BETWEEN SHALLOW AND DEEP AREAS SHALL BE AT A MINIMUM WATER DEPTH OF 2 FEET 9
INCHES AND BE AT LEAST 6 FEET FROM THE SHALLOW END
3. (5.6.3) THE SLOPE OF THE FLOOR FROM THE POINT OF THE FIRST SLOPE CHANGE TOWARD THE DEEP END SHALL NOT
EXCEED 1 FOOT IN 3 FEET
4. WALLS SHALL NOT SLOPE > 11 DEGREES
5. HAND HOLD TO BE INSTALLED WHERE DECK RAISED +6" ABOVE POOL
12" MAX
12" MAX
12" MAX
4'
PAGE 2 OF 2
· BUILDER IS MIKE DIFRANCESCO. CELL IS: 772-
201-7797
· TRAVERTINE DECK AND 4" ROCK BASE BY
TAURUS CONSTRUCTION
· SCREEN ENCLOSURE BY PIONEER SCREEN
· ELECTRIC BY ED’S ELECTRIC
DIRECTIONS:
GLADES CUTOFF ROAD SOUTH TO RESERVE
BLVD, GO THROUGH GUARD GATE, FIRST RIGHT
ONTO SADDLEBROOK DR, LEFT ON
MYRTLEWOOD LANE, THE LEFT ON SABAL LAKE
DRIVE
DECO DRAIN
CHILD SAFETY
BARRIER FENCE NO
CLOSER THAN 20"
FROM WATERLINE7 ft.5 ft.
5 ft.3 ft.5 ft.8 ft.
25 ft.60 ft. 5 in.60 ft. 4 in.SKIMMER WITH
AUTOFILL AND
OVERFLOW 6' DEEP
BEACH
ENTRY
COLOR LED
VAC LINE
COLOR LED
COLOR LED
COLOR LED
COLOR LED
SKIMMER
5'x8' SPA RAISED 12"
WITH 8 HYDRO JETS,
2HP JET PUMP, COLOR
LED LIGHT, JANDY RS6
AUTOMATION, 2
MARBLE SPILLWAYS
SPA SIDE WALL RAISED
18" WITH 24" SHEER
DESCENT ON EACH
WALL
TILED STEP
EDGES 3' DEEP
10 ft.4 ft. 9 in.4 ft. 9 in.
(4) BUBBLERS AT
BEACH ENTRY, 1
UMBRELLA SLEEVE
SAFETY BARRIER PER FRC R4501.17.1-
R4501.17.3 & ASTM5034-95, ASTM D3787-
89, ASTM 653-96
POOL BARRIER PER FRC R4501.17.1-
R4501.1.17.3 AND ANSI/NSPI-5-1995
EQ.
EQUIPMENT PAD
PER FBC
4501.22(9.2)
POOL EQUIPMENT
ANCHORED PER
FBC 2020 7TH
EDITION
R
R
R
R
R R
H
H
H
H
H
HHH2.5"
2.5"
3"3"
1"
R
S
6
1"
1.5"
1.5"
1.5"
2"
1.5"
1.5"
1.5"
1.5"
1"
1"
2"
1"
1"
3"
1.5"
1"
2"
1.5"1.5"1.5"1.5"
1 ft.43 ft. 4 in.15 ft.