HomeMy WebLinkAbout204330-1pd Pool Backfill - signedHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB # :200957-1pd/MR/bm
PERMIT #:21020067
CONTRACTOR:A & G Pools NUC #215
Nuc Model:MC-1DR-P
465 SE Veranda Avenue Nuc Serial #:MD80404215
Port St Lucie, Florida
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE
PERCENT
COMPACTION
1 East 0'-1'14D 108.9 111.1 98.0%
2 1'-2'13D -"95.0% +
3 2'-3'15D -"95.0% +
4 3'-4'15D -"95.0% +
5 South 0'-1'13D 109.0 111.1 98.1%
6 1'-2'14D -"95.0% +
7 2'-3'15D -"95.0% +
8 3'-4'15D -"95.0% +
9 N.W.0'-1'13D 109.5 111.1 98.6%
10 1'-2'15D -"95.0% +
11 2'-3'15D -"95.0% +
12 3'-4'16D -"95.0% +48
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
6/28/2021
Pool Backfill Compaction
for Plumbed Backfill
JOB LOCATION:
Bryan E. Dahlke, P.E. V.P. of Engineering
Degree of Compaction Meets
DATE TESTED:
Shell Fragments
In Place Moisture:
Respectfully Submitted:
PO:
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
13.0%
June 25, 2021
ITEM TESTED :
Soil Description:
111.1
Penetrometer reading indicate the
TEST LOCATION
OF SAMPLE
Cuesta / 2101009
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE
13.0%
PE # 81439
Disclaimer:Contractor is responsible to maintain the pool
backfill in the condition that KSM completed the indicated
passed compaction test.KSM is not responsible if the
poolbackfill has been altered from the approved inspected
condition.
Clayed Brown Sand with Some
Minimum Requirement
Email to: Abirmingham@AnGPools.com
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
106.0
107.0
108.0
109.0
110.0
111.0
112.0
113.0
8 9 10 11 12 13 14 15 16
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight