Protect Summary Entire House Lindstrom Air Conditioning 3581 W MCNAB RE), POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.corn Proiect Information For: HOMECRETE Notes: MARSAN Design Information Weather Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 21508 Btuh Ducts 3276 Btuh Central vent (52 cfm) 1586 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 26370 Btuh Infiltration Fort Pierce, FL, US Method Simplified Construction quality Average Fireplaces 0 Area Heatingg Coolingg (ft2 1817 1817 Volume ()ft3) 14538 14538 Air Chan�gges/hour 0.38 0.20 Equiv.AVF (cfm) 92 48 Heating Equipment Summary Make CARRIER Trade Model CH16NA036 AHRI ref Efficiency 8.5 HSPF Heating input Heating output 35000 Btuh @ 47°F Temperature rise 27 OF Actual air flow 1200 cfm Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Space thermostat Capacity balance point = 0 OF Backup: CARRIER 5 KW Input = 7 kW, Output = 24512 Btuh, 100 AFUE Job: Date: 4-2021 By: LINDSTROM Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity M 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 19493 Btuh Ducts 5435 Btuh Central vent (52 cfm) 850 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipment sensible load 0.95 24489 Btuh Latent Cooling Equipment Load Sizing Structure 3024 Btuh Ducts 1569 Btuh Central vent (52 cfm) 2153 Btuh Outside air Equipment latent load 6747 Btuh Equipment Total Load (Sen+Lat) 31235 Btuh Req. total capacity at 0.78 SHR 2.6 ton Cooling Equipment Summary Make CARRIER Trade Cond CH16NA036 Coil FX4DNF037 AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 27200 Btuh 7800 Btuh 35000 Btuh 1200 cfm 0.048 cfm/Btuh 0 in F120 0.79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -f- llr wrightso_ft- 2021-Apr-1216:43:13 •«• Right -Suite® Universal2019 19.0,12 RSU08398 Page 1 '�� ...JECTS ENERGYIA- MANUAL JIHOMECRETE - MARSAN.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Job: Entire House Date: 4-2021 -•-. Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD. POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.findstromair.com 1 2 Room name Exposed wall Entire House BED 1 3 Room height 175.5 ft 26.0 ft 4 Room dimensions 80 ft 8.0 ft heat/cool 5 Room area 1817.2 ft' 14.6 x 12.0 ft 175.2 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (BtutVft'-°F) (Btuhlft� or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/PIS Heat Cool 6 W 13A-6ocs 0.111 n 3.11 1.48 296 284 863 419 0 0 0 0 (� _G i D-h2om 0.870 n 24.36 22.27 12 0 292 267 0 0 0 0 1D-h2am 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-6ocs 0.111 a 3.11 1.48 506 365 1134 539 0 0 0 0 11 1 D-h2om 0.870 a 24.36 53.71 30 3 731 1611 0 0 0 0 1D-h2omd 0.870 a 24.36 27.91 96 159 2339 2680 0 0 0 0 1 D-h2om 0.870 a 24.36 22.27 15 30 365 334 0 0 0 0 13A-6ocs 0.111 s 3.11 1.48 304 265 824 391 96 96 298 142 1D-h2om 0.870 s 24.36 22.27 9 18 219 200 0 0 0 0 1D-h2om 0.870 s 24.36 22.27 15 30 365 334 0 0 0 0 ID-h2om 0.870 s 24.36 22.27 15 30 365 334 0 0 0 0 W 13A-6ocs 0.111 w 3.11 1.48 248 166 516 245 112 82 265 121 1D-h2om 0.870 w 24.36 53.71 30 3 731 1611 30 1 731 1611 1 D-h2om 0.870 w 24.36 23.53 30 58 731 706 0 0 0 0 11 DO 0.390 w 10.92 10.34 22 22 240 227 0 0 0 0 126-0bw 0.097 - 2.72 0.61 172 150 407 92 0 0 0 0 11 DO 0.390 s 10.92 10.34 22 22 240 227 0 0 0 0 C F 168-19ad 0.049 s 1.37 2.45 1817 1817 2493 4452 175 175 240 429 22A-tpm 1.180 s 33.04 0.00 1817 176 5799 0 175 26 859 0 6 c) AED excurs on 472 558 Envelope loss/gain 18675 15144 2383 2861 12 a) Infiltration b) Room ventilation 2833 799 435 123 0 0 0 0 13 Internal gains: Occupants Q 230 5 1150 1 230 Appliances/other 2400 0 Subtotal (lines 6 to 13) 21508 19493 2819 3214 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Ductloads 21508 19493 2819 3214 151/0 28% 3276 5435 15% 280% 429 896 Total room load Air required (cfrn) 24784 24928 3248 4110 1200 1200 1671 198 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -4d- wrigFstsottt^ 2021-A-1216:43:13 p• ACZ`/. Right-SuiteC Universal 2019 19.0.12 RSU08398 Page 1 JECTS ENERGYIA- MANUAL JIHOMECRETE - MARSAN.rup Cale = MJB Front Door faces: N Right-J@ Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954421-4117 Fax: 954-420-0064 Weh www r �d�f��mar�� m Job: Date: 4-2021 By: LINDSTROM 1 2 Room name Exposed wall BATH 2 BED 2 3 Room height 6.0 ft 8.0 ft heat/cool 26.0 ft 8.0 ft heat/cool 4 Room dimensions 6.0 x 10.0 ft 12.0 x 14.0 ft 5 Room area 60.0 ft2 168.0 ft, Ty Construction U-value Or HTM Area (ft') Load Area (ft� Load number (BtuNftl- °F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 VP 13A-6ccs 0.111 n 3.11 1.48 0 0 0 0 0 0 0 0 1D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 1D-h2cxn 0.870 n 0.00 0,00 0 0 0 0 0 0 0 0 13A-6ocs 0.111 a 3.11 1.48 90 90 280 133 112 112 M8 165 11 ID-h2om 0.870 a 24.36 63.71 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 a 24.36 27.91 0 0 0 0 0 0 0 0 ID-h2om 0.870 a 24.36 22.27 0 0 0 0 0 0 0 0 13A-6ccs 0.111 s 3.11 1.48 48 39 121 58 96 81 252 120 1 D-h2cm 0.870 s 24.36 22.27 9 9 219 200 0 0 0 0 1D-h2cm 0.870 s 24.36 22.27 0 0 0 0 15 15 365 334 1D-h2cm 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 13A-60cs 0.111 w 3.11 1.48 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 53.71 0 0 0 0 0 0 0 0 ID-h2om 0.870 w 24.36 23.53 0 0 0 0 0 0 0 0 11 DO 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 R T-D 12B-Obw 0.097 - 2.72 0.61 0 0 0 0 0 0 0 0 11 DO 0.390 s 10.92 10.$4 0 0 0 0 0 0 0 0 C 168-19ad 0.049 s 1.37 2.45 60 60 82 147 168 168 230 412 F 22A-tpm 1.180 s 33.04 0.00 60 6 198 0 168 26 859 0 61 c) AED excursion -42 -93 Envelope loss/gain 901 498 2055 938 12 a) Infiltration 289 81 435 123 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 1189 6781 2490 1290 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 1189 578 24110 1290 15% 28% 181 161 15% 28% 379 360 Total room load Air required (cfrn) 1371 7391 2869 1650 66 36 139 79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -1►- wrigt►tsoTt^ 2021-Apr-12 16:43:13 ��p` Right -Suite® Universal 2019 19.0.12 RSU08398 Page 2 ...JECTS ENERGYIA- MANUAL 4HOMECRETE - MARSAN.rup Calc = MJ8 Front Door faces: N ow Right-J® Worksheet°b' o«o-„o« Entire House Date: 4-2021 i-ipl By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromaircom 1 Room name DINING ROOM GREAT ROOM 2 Exposed wall ITT ft 14.0 ft 3 Room height 8.0 ft heaUcool 8.0 ft heat/cod 4 Room dimensF3rls 18.0 x 16.0 ft 15.0 x 15.0 ft 5 Room area 288.0 ft' 225.0 ft' Ty Construction U-value Or HTM Area (ftz) Load Area (ftj Load number (Btuh/ft- °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-6ocs 0.111 n 3.11 1.48 0 0 0 0 0 0 0 0 10•h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 1D-h2om 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 0.111 a 3.11 1.48 0 0 0 0 112 16 50 24 11TE�13A-6ocs 1 D-h2om 0.870 a 24.36 53.71 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 a 24.36 27.91 0 0 0 0 96 80 2339 2680 1 D-h2om 0.870 a 24.36 22.27 0 0 0 0 0 0 0 0 13A-6ocs 0.11 s 3.11 1. 0 0 0 0 0 0 0 0 1 D-h2om 0.8700 s 24.36 22.2727 0 0 0 0 0 0 0 0 1D-h2om 0.870 s 24.36 2227 0 0 0 0 0 0 0 0 1 D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 13A-6ocs 0.111 w 3.11 1.48 136 84 261 124 0 0 0 0 1D-h2om 0.870 w 24.36 53.71 0 0 0 0 0 0 0 0 1D-h2om 0.870 w 24.36 23.53 30 29 731 706 0 0 0 0 11 DO 0.390 w 10.92 10.34 22 22 240 227 0 0 0 0 F} g--D 12B-ObAt 0.097 - 2.72 0.61 0 0 0 0 0 0 0 0 11 DO 0,390 s 10,92 10.34 0 0 0 0 0 0 0 0 C 1613-19ad 0.049 s 1.37 2.45 288 288 395 706 225 225 309 551 F 22A-tpm 1.180 s 33.04 0.00 288 17 562 0 225 14 463 0 6 c) AED excursion 892 -224 Envelope loss/gain 2189 2655 3160 3031 12 a) Infiltration 285 60 234 66 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 0 Subtotal (lines 6 to 13) 2474 2735 3394 3097 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2474 2735 3394 3097 15 Duct loads 15% 28% 377 763 159/. 28% 517 864 Total room load 2850 34981 3911 3961 Air required (cfm) 138 168 1891 191 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ 44+- 2021-Apr-12 16:43:13 a Right -Suite® Universal 2019 19.0A2 RSU08398 Page 3 '� � ...JECT ENERGY\A- MANUAL J\HOMECRETE - MARSAN.rup Calc = MJ8 Front Door faces: N Right-JO Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-491-4117 Fw- ose-eon_nnan M k ,......., -A, Job: Date: 4-2021 By: LINDSTROM 1 Room name 2 Exposed wall KITCHEN LAUNDRY 3 Room height 8.0 ft 7.0 ft 4 Room dimensions 8.0 ft heat/cool 8.0 ft heat/cool 5 Room area 13.3 x 2o.o ft 10.0 x 7.0 ft 265.0 ftz 70.0 ft2 Ty Construction U-value Or HTM Area (ftx Load Area (ft� Load number (Btuh/ftz °F) (Btumv) or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-11ccs 0.111 n 3.11 1.48 0 0 0 0 0 0 1D-h2cm 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 0 1 D-112cm 13A-6ccs 0.870 0.111 n 0.00 0.00 0 0 0 0 0 0 0 0 0 11 1 D-h2cm 0.870 a a 3.11 24.36 1.48 53.71 80 0 65 0 202 96 0 0 0 0 1 D-h2cmd 0.870 a 24.36 27.91 0 0 0 0 0 0 0 0 0 0 0 0 1 D-h2cm 13A-60cs 0.870 0.111 a 24.38 22.27 15 15 365 334 0 0 0 0 0 0 1D-h2om 0.870 S s 3.11 24.36 1.48 22.27 0 0 0 0 0 0 0 0 0 0 0 0 ID-h2cm 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 13A-60cs 0.870 0.111 s 24.36 22.27 0 0 0 0 0 0 0 0 0 1D-h2om 0.870 w w 3.11 24,36 1.48 53.71 0 0 0 0 0 0 0 0 0 0 0 1 D-h2cm 0.870 w 24.36 23.53 0 0 0 0 0 0 0 0 0 0 0 0 11 DO 126-Obw 0.390 0.097 w - 10.92 2.72 10.34 0,61 0 0 0 0 0 0 0 0 0 11 DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 56 22 34 22 92 240 21 227 C F 16B-19ad 22A-tprn 0.049 s 1.37 2.45 265 265 364 649 70 70 96 172 1.180 s 33.04 0.00 265 6 264 0 70 7 231 0 6 c) AED excursion 172 28 Envelope loss/gain 1195 907 660 391 12 a) Infiltration b) Room ventilation 167 47 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 1 290 0 Appliances/other 0 1200 0 Subtotal (lines (3 to 13) 1363 2384 660 391 Less external Iced Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Ductloads 1363 2384 660 391 15% 28% 1 208 665 150/0 28% 101 109 Total room load Air required (cfm) 157 0 304976 760 501 147 37 24 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wri gtitsoYtN �^'�� Right -Suite® Universal 2019 19.0.12 RSU08398 2021-Apr-12 16:43:13 ... JECTS ENERGYL4- MANUAL JIHOMECRETE - MARSAN.rup Calc = MJB Front Door faces: N Page 4 Right-J® Worksheet Job: «w Entire house Date: 4-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954420-0064 Web: www.lindstromair.com 1 Room name MASTER TOILET MASTER BATH 2 Exposed wall 4.0 ft 23.5 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 4.0 x 6.5 ft 12.0 x 12.0 ft 5 Room area 26.0 ft2 144.0 ft' Ty Construction U-value Or HTM Area (ft') Lead Area (ftz) Load number (Btuhlftk'F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 13A-8ocs 0.111 n 3.11 1.48 0 0 0 0 104 92 286 136 1 D-h2om 0.870 n 24.36 22.27 0 0 0 0 12 0 292 267 1 D4h2om 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 13A-6ws 0.111 a 3.11 1.48 0 0 0 0 0 0 0 0 11 1 D-h2om 0.870 a 24.36 53.71 0 0 0 0 0 0 0 0 10-h2omd 0.870 a 24.36 27.01 0 0 0 0 0 0 0 0 1 D-h2om 0.870 a 24.36 22.27 0 0 0 0 0 0 0 0 s 3.11 1. 0 0 0 0 0 0 0 0 1D-h2om 0.870.870 s 24.36 22.2727 0 0 0 0 0 0 0 0 TE�13A-6o 1 D-h2om 0.870 s 24.35 22.27 0 0 0 0 0 0 0 0 1 D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 13A-6om w 3.11 1.71 0 0 0 0 0 0 0 0 TE� 1D-h2om 0.870 .871 w 24.36 53.71 D 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 23.53 0 0 0 0 0 0 0 0 11 DO 0,390 w 10.92 10.34 0 0 0 0 0 0 0 0 12B-Obw 0.097 - 2.72 0.61 32 32 87 20 84 84 228 51 11 DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-1990 0.049 s 1.37 2.45 26 26 36 64 144 144 198 353 F 22A-tpm lA80 s 33.04 0.00 26 4 132 0 144 24 T16 0 6 c) AED excursion -6 -139 Envelope loss/gain 255 78 1780 668 12 a) Infiltration 0 0 218 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1200 Subtotal (lines 6 to 13) 255 78 1998 1929 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 255 78 1998 1929 15 Duct loads 1 15% 28% 39 22 15% 28% 304 538 Total room load 294 99 2302 2467 Air required (cfm) 14 5 111 119 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �- wrightsoTC 2021-Apr-12 16:43:13 -�K Right -Suite® Universal 2019 19.0.12 RSU08398 Page 5 ..JECTS ENERG;Ia- MANUAL AHOMECRETE - MARSAN.rup Calc = MJ8 Front Door faces: N Right-JO Worksheet Entire Douse Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH. FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 W.h Job: Date: 4-2021 By: LINDSTROM 1 2 Room name Exposed wall WIC MASTER INT WIC MASTER E>CT 3 Room height 0 ft 8.0 ft 4 Room dimensions 8.0 ft heat/cool 8.0 ft heat/cool6.0 5 Room area x 8.0 ft 8.o x e.o ft 48.0 ft' 48.0 ft z Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load Load number (Btuh/f? °F) (Btuh/M or perimeter (ft) (Btuh) or perimeter (ft) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V6 13A-5ccs 0.111 n 3.11 1,48 0 0 0 0 64 64 199 1D-h2cm 0.870 n 24.36 22.27 0 0 0 0 0 0 0 94 1 D-h2om 13A-6ocs 0.870 0.111 n 0.00 0.00 0 0 0 0 0 0 0 0 0 11 1D-h2om 0.870 a e 3.11 24.36 1.48 53,71 0 0 0 0 0 0 0 0 0 0 0 0 1D-h2omd 0.870 a 24.36 27.91 0 0 0 0 0 0 0 0 0 1 D-h2om 0 870 a 24.36 22.27 0 0 0 0 0 0 0 0 0 13A-6ocs 0.111 s 3.11 1.48 0 0 0 0 0 0 0 1 D h2om 1 D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0,870 0.870 s s 24.36 24.36 22.27 22.27 0 0 0 0 0 0 0 0 0 0 W 13A-6ocs 0.111 w 3.11 1.48 0 0 0 0 0 0 0 0 0 0 0 1D-h2om 0.870 w 24.36 53.71 0 0 0 0 0 0 0 0 0 0 1D-h2om 0.870 w 24.36 23.63 0 0 0 0 0 0 0 0 11DO 126-Obw 0.390 0.097 w - 10.92 2.72 10.34 0.61 0 0 0 0 0 0 0 0 0 11 DO 0.390 s 10.92 10.34 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D C F 168-19ad 22A-tpm 0.049 1.180 s 1.37 2.45 48 48 66 118 48 48 0 66 0 118 s 33.04 0.00 48 0 0 0 48 8 264 0 6 c) AED excursion 8 17 Envelope loss/gain 66 110 529 195 12 a) Infiltration b) Room ventilation 0 0 134 38 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 Appliances/other 0 0 0 Subtotal (lines 6 to 13) 66 110 663 233 Less external load Less transfer p Q 0 0 Redistribution 14 Subtotal 0 0 0 0 15 Duct loads 15% 28% 66 10 110 31 15% 28% 663 101 233 65 Total room load 1 Air required (cfm) i 76 140 764 298 4 7 37 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ►�- wrtgF�tsott r-12 16:43:13 �" �� Right -Suite® Universal 2019 19.0.12 RSU06398 2021-AprPage 6 ..JECTS ENERGY\A- MANUAL J\HOMECRETE - MARSAN.rup Calc = MJ8 Front Door faces: N p Right-JO Worksheet Job: 2 Entire House Date: 4-2021 Lindstrom Air Conditioning By: LINDSTROM 3681 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name MASTER SUITE 2 Exposed wall 36.0 ft 3 Room he t 8 0 ft cool 4 Room chmensions 15.0 x 20.0ftheat 5 Room area 300.0 ft' U-value Or HTM Area (ftz) Load Area Load TCuOnLrfuction (13tuh/11MF) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat cool Gross N/P/S Heat CON 6 13A-6ocs 0.111 n 3.11 1.48 128 128 395 189 1 D-h2om 0.870 n 24.36 22.27 0 0 0 0 ID-h2om 0.870 n 0.00 0.00 0 0 0 0 13A-6ocs 0.111 a 3.11 1.48 112 82 255 121 11 1D-h2om 0.870 a 24.36 53.71 30 1 731 1611 1 D-h2omd 0.870 a 24.36 27.91 0 0 0 0 1 D4i2om 0.870 a 24.36 22.27 0 0 0 0 13A-6ocs 0.111 s 3.11 1.48 64 49 152 72 1D-h2om 0.870 s 24.36 22.27 0 0 0 0 1D-h2om 0.870 s 24.36 22.27 0 0 0 0 1D-h2om 0.870 s 24.36 22.27 15 15 365 334 13A-6ocs 0.111 w 3.11 1,48 0 0 0 0 150 1 D-h2om 0.870 w 24.36 53.71 0 0 0 0 1 D-h2om 0.870 w 24.36 23.53 0 0 0 0 11 DO 0.390 w 10.92 10.34 0 0 0 0 126.0bw 0.097 - 2.72 0.61 0 0 0 0 11 DO 0.390 s 10.92 10.34 0 0 0 0 C 1613-19ad 0.049 S 1.37 2.45 300 300 412 735 F 22A-tpm 1.180 s 33.04 0.00 300 36 1189 0 6 c) AED excursion -249 Envelope loss/Bain 3502 2814 12 a) Infiltration 636 179 b) Room ventilation 0 0 13 Internal gains: Occupants 230 2 460 Appliances/other 0 Subtotal (lines 6 to 13) 4138 3453 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 4138 3453 15 Duct loads 15% 25% 630 963 Total room load 4769 4416 Air required (cfrn) 231 213 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed - wrightsoity 2021-Apr-1216:43A3 Right-Sufte® Universal 2019 19.0.12 RSU08398 Page 7 ACZp` ...JECTS 'NERGYW MANUAL AHOMECRETE - MARSAN.rup Calc = MJ8 Front Door faces: N FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HOMECRETE - MARSAN Builder Name: HOMECRETE Street: SUNRISE BLVD Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: MARSAN RES. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1424.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=6.5 1264.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 160.00 ft2 c. NIA R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? No 11. Ceiling Types (1817.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 1817.00 ft2 6. Conditioned floor area above grade (ft2) 1817 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(237.0 sqft,,) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.29 141.00 ft2a. Sup: Attic, Ret: Attic, AH: Garage 6 300 SHGC: SHGC=0.29 b. U-Factor: Dbl, U=0.32 96.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.26 a. Central Unit 35.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 7.462 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.278 a. Electric Heat Pump 35.0 HSPF:8.50 8. Skylights Area C. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1817.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 '16. Credits Pstat Glass/Floor Area: 0.130 Total Proposed Modified Loads: 52.31 PASS Total Baseline Loads: 56.86 I hereby certify that the plans and specifications covered by Review of the plans and 0� SHE S7,q?�c+ this calculation are in compliance with t e Florida Fner y Code. Z) specifications covered by this calculation indicates compliance with the Florida Energy Code. •+:::,,'... °tom'.,°;.�,ti Q PREPARED BY: - Before construction is completed DATE: this building will be inspected for y compliance with Section 553.908 �� * C I hereby certify that ing, as designed, is in compliance Florida Statutes. - 6� with the Florida Enemy Code. C'QQ,•E�¢ OWNER/AGENT: j BUILDING OFFICIAL: DATE: -- � DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/12/2021 5:32 PM EnergyGaugee USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-202_ INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HOMECRETE - MARSAN Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot # Owner Name: MARSAN RES. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: HOMECRETE Rotate Angle: 135 Street: SUNRISE BLVD Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1817 18170 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BED '1 184 1840 No 1 3 1 No Yes Yes 2 BATH 2 60 600 No 0 1 No Yes Yes 3 BED 2 168 1680 No 1 1 No Yes Yes 4 DINING ROOM 256 2560 No 0 1 No Yes Yes 5 GREAT ROOM 225 2250 No 0 1 No Yes Yes 6 NOOK 88 880 No 0 1 No Yes Yes 7 KITCHEN 200 2000 No 0 1 No Yes Yes 8 LAUNDRY 70 700 No 0 1 No Yes Yes 9 MASTER TOILET 26 260 No 0 1 No Yes Yes 10 MASTER BATH 144 1440 No 0 1 No Yes Yes 11 WIC MASTER INT 48 480 No 0 1 No Yes Yes 12 WIC MASTER EXT 48 480 No 0 1 No Yes Yes 13 MASTER SUITE 300 3000 No 2 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 1 26 ft 0 174 ft2 0 0 1 2 Slab -On -Grade Edge Insulatio BATH 2 6 ft 0 60 ft2 _--- 1 0 0 3 Slab -On -Grade Edge Insulatio BED 2 26 ft 0 168 ft2 0 0 1 4 Slab -On -Grade Edge Insulatio DINING ROOM 17 ft 0 411 ft2 _-_- 1 0 0 4/12/2021 5:32 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPI IT CI IIIAUAL)V t-U=fl l ie-r ocpf%oT FLOODS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio GREAT ROOM 14 ft 0 70 ft2 ____ 0 0 1 6 Slab -On -Grade Edge Insulatio NOOK 19 ft 0 88 ft2 --__ 1 0 0 7 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 200 ft2 -___ 1 0 0 8 Slab -On -Grade Edge Insulatio LAUNDRY 7 ft 0 70 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulatio MASTER TOILET O ft 0 36 ft2 1 0 0 10SIab-On-Grade Edge Insulatio MASTER BATH 23.5 ft 0 144 ft2 ____ 1 0 0 11Slab-On-Grade Edge Insulatio WIC MASTER IN 1 ft 0 48 ft2 ___ 0 0 1 12SIab-On-Grade Edge Insulatio WIC MASTER EX 8 ft 0 48 ft2 -___ 0 0 1 13Slab-On-Grade Edge Insulatio MASTER SUITE 30 ft 0 300 ft2 _--_ 0 0 1 ROOF / V Roof # Type Materials Area Gable Area Roof Color Rad Barr Solar Absor. SA Emitt Tested Emitt Deck Tested Insul. Pitch (deg) 1 Hip Metal 1952 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 18.43 ATTIC % V Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1852 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BED 1 38 Blown 174 ft2 0.1 Wood 2 Under Attic (Vented) BATH 2 38 Blown 60 ft2 0.1 Wood 3 Under Attic (Vented) BED 2 38 Blown 168 ft2 0.1 Wood 4 Under Attic (Vented) DINING ROOM 38 Blown 411 ft2 0.1 Wood 5 Under Attic (Vented) GREAT ROOM 38 Blown 70 ft2 0.1 Wood 6 Under Attic (Vented) NOOK 38 Blown 88 ft2 0.1 Wood 7 Under Attic (Vented) KITCHEN 38 Blown 200 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 38 Blown 70 ft2 0.1 Wood 9 Under Attic (Vented) MASTER TOILET 38 Blown 36 ft2 0.1 Wood 10 Under Attic (Vented) MASTER BATH 38 Blown 144 ft2 0.1 Wood 11 Under Attic (Vented) WIC MASTER IN 38 Blown 48 ft2 0.1 Wood 12 Under Attic (Vented) WIC MASTER EX 38 Blown 48 ft2 0.1 Wood 13 Under Attic (Vented) MASTER SUITE 38 Blown 300 ft2 0.1 Wood 4/12/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT -RtIMMARV P.W1=('-k1 ICT RFPnRT WALLS a Adjacent Space Ornt To Cavity Width Height Sheathing Framing Solar Belowo 1 N=>SE Exterior Concrete Block - Int Insul BED 1 6.5 12 0 8 0 96.0 ft2 0 0 0.5 0 _ 2 E=>SW Exterior Concrete Block - Int Insul BED 1 6.5 14 0 8 0 112.0 ft2 0 0 0.5 0 3 N=>SE Exterior Concrete Block - Int Insul BATH 2 6.5 6 0 8 0 48.0 ft2 0 0 0.5 0 _ 4 N=>SE Exterior Concrete Block - Int Insul BED 2 6.5 12 0 8 0 96.0 ft2 0 0 0.5 0 _ 5 W=>NE Exterior Concrete Block - Int Insul BED 2 6.5 14 0 8 0 112.0 ft2 0 0 0.5 0 6 E=>SW Exterior Concrete Block - Int InSDIINING ROO 6.5 17 0 8 0 136.0 ft2 0 0 0.5 0 7 W=>NE Exterior Concrete Block - Int InsGIREAT ROO 6.5 14 0 8 0 112.0 ft2 0 0 0.5 0 8 N=>SE Exterior Concrete Block - Int Insul NOOK 6.5 8 0 8 0 64.0 ft2 0 0 0.5 0 - 9 W=>NE Exterior Concrete Block - Int Insul NOOK 6.5 10 0 8 0 80.0 ft2 0 0 0.5 0 _ 10 S=>NW Exterior Concrete Block - Int InsMASTER BA 6.5 13 0 8 0 104.0 ft2 0 0 0.5 0 _ 11 S=>NW Exterior Concrete Block - Int InsWIC MASTE 6.5 8 0 8 0 64.0 ft2 0 0 0.5 0 12 S=>NW Exterior Concrete Block - Int InsMASTER SUI 6.5 16 0 8 0 128.0 ft2 0 0 0.5 0 _ 13 W=>NE Exterior Concrete Block - Int InsMASTER SUI 6.5 14 0 8 0 112.0 ft2 0 0 0.5 0 14 E=>SW Garage Frame - Wood BED 1 11 20 8 160.0 ft2 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Wood BED 1 None .39 2.8 8 22.4 ft2 2 E=>SW Insulated DINING ROO None .46 3 8 24 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 135 degrees). / Wall Overhang 1/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E=>SW 2 Metal Double (Tinted) Yes 0.29 0.29 N 15.0 ft2 1 ft 6 in 1 ft 0 in None None 2 N=>SE 3 Metal Double (Tinted) Yes 0.29 0.29 N 9.0 ft2 1 ft 6 in 1 ft 0 in None None 3 N=>SE 4 Metal Double (Tinted) Yes 0.29 0.29 N 15.0 ft2 1 ft 6 in 1 ft 0 in None None 4 E=>SW 6 Metal Double (Tinted) Yes 0.29 0.29 N 30.0 ft2 7 ft 0 in 1 ft 0 in None None 5 W=>NE 7 Metal Double (Tinted) Yes 0.32 0.26 N 96.0 ft2 14 ft 6 in 1 ft 0 in None None 6 S=>NW 10 Metal Double (Tinted) Yes 0.29 0.29 N 12.0 ft2 1 ft 6 in 1 ft 0 in None None 7 S=>NW 12 Metal Double (Tinted) Yes 0.29 0.29 N 30.0 ft2 1 ft 6 in 1 ft 0 in None None 8 W=>NE 13 Metal Double (Tinted) Yes 0.29 0.29 N 30.0 ft2 1 ft 6 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 469 ft2 469 ft2 64 ft 8 ft 1 4/12/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 IMPI IT CI IIUIMAcv I-Uce-ier ioT o=nr-.nr .-11Vwl\I_I"I 114-r Vlll INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2119.8 116.3 218.34 .1381 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:8.5 35 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Sing] SEER: 16 35 kBtu/hr 1050 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Mode] # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / ---- Supply ---- V # Location R-Value Area -- Return---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 300 ft2 Attic 150 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Cooling Jan ] Feb [ MarA Heating tX� Jan f X) Feb [X� Mar Venting ( Jan l ]]]] Feb ((X Mar Ceiling Fans: Jul rj Aug Se j Apr I r Ma X Jun ri MayJun Jul AuSep E �X- ] Apr May [ Jun JulAug Se [ Oct Nov Nov Oct ki Oct Nov Dec Dec H Dec 4/12/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKL r REPORT Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 4 5 Cooling (WD) AM PM 78 80 78 78 78 78 80 78 78 78 Cooling (WEH) AM 78 78 78 78 78 PM 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 PM 68 68 68 68 68 Heating (WEH) AM 66 66 66 66 66 PM 68 68 68 68 68 Mass Type Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft, Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. MASS Area Thickness 0ft2 Oft ft2 ft ft2 ft ft2 ft ft2 ft ft2 ft ft2 ft ft2 ft ft2 ft ft2 ft ft2 ft ft2 ft ft2 ft Hours 6 7 8 9 10 11 78 78 78 80 080 78 78 78 78 i8 78 78 78 78 78 78 78 78 78 78 78 78 78 68 68 68 68 68 68 68 68 68 68 68 66 68 68 68 68 68 68 68 68 68 68 68 66 Furniture Fraction Space 0.3 BED 1 0.3 BATH 2 0.3 BED 2 0.3 DINING ROOM 0.3 GREAT ROOM 0.3 NOOK 0.3 KITCHEN 0.3 LAUNDRY 0.3 MASTER TOILET 0.3 MASTER BATH 0.3 WIC MASTER INT 0.3 WIC MASTER EXT _ 0.3 MASTER SUITE 78 78 68 66 4/12/2021 5:32 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.29 SHGC: SHGC=0.29 b. U-Factor; Dbl, U=0.32 SHGC: SHGC=0.26 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A SUNRISE BLVD, FORT PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Detached a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 3 d. N/A No 11. Ceiling Type and insulation level a. Under Attic (Vented) 1817 b. N/A Area c. N/A 141.00 ft2 12. Ducts, location & insulation level a. Sup: Attic, Ret: Attic, AH: Garage 96.00 ft2 13. Cooling systems ft2 a. Central Unit ft2 7.462 ft. 0.278 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1817.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installe liant feat Builder Signature: , Date: �'% ''/ 3 - Z. Address of New Home: nIlxi City/FL Zip: �I ` 3448,;>- Insulation Area R=6.5 1264.00 ft2 R=11.0 160.00 ft2 R= ft2 R= ft2 Insulation Area R=38.0 181 T00 ft2 R= ft2 R= ft2 R ft2 6 300 kBtu/hr Efficiency 35.0 SEER:16.00 kBtu/hr Efficiency 35.0 HSPF:8.50 Cap: 50 gallons EF: 0.95 Pstat 0 *CIE 5 4V ,D *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/12/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1