HomeMy WebLinkAboutAPPROVED REVISED PLANS 052821ILL. 0 CL Q Q Lr1 77 In 00 N O 00 N zT 7 N N Lrn 0 w GENERAL NOTES SUMMARY OF WORK: 1. Project Description: New 1-story residence. 2. Work Involved: a. Roof: 5V-Crimp Metal Roof, Peel-n-Stick Roof Underlayment, exterior sheathing, pre-engineered trusses, R-38 Blown Insulation for A/C space. b. Walls: i. Exterior: 8" CMU walls with exterior stucco finish and min. 1" Thk rigid board insulation, 1X P.T. furring and 1/2" drywall at the interior side ii. Interior: Metal studs, batt insulation, with 1/2" drywall each side c. Ceiling: i. 5/8" drywall - see plans for trays, coffers and vaults ii. Exterior ceiling finish shall be 1/2" thick stucco on high rib lath attached per note on wall section. d. Foundation: Concrete thickened slab edge and 4" concrete floor slab e. Mechanical: i. Provide (1) unit per plans ii. Exhaust all bathrooms and dryer f. Electrical: i. Provide power and lighting per plans ii. Provide 200 amp service and 40 slot panel g. Plumbing: i. Provide water heater per plans ii. Provide sanitary lines per plans and risers iii. Provide plumbing fixtures per plan h. Work completed shall meet all local and state building code requirements. COORDINATION: 1. Contractor shall verify existing site conditions of project location prior to commencement of work. 2. Contractor shall coordinate and verify all utility requirements, compatibility and location of projected utilities of project, as shown on the drawings. 3. Contractor shall verify space requirements and location of project utilities. 4. Contractor shall field verify all dimensions of project. Do not scale drawings. 5. Contractor shall notify Architect of any discrepancies in drawings and/or specifications of project. Commencement of the work without proper notification to the Architect, the contractor will assume responsibility of work performed. 6. Contractor shall notify the Architect, when the full intent of the drawings and/or specifications is not clear. Commencement of the work without proper notification to the Architect, the contractor will assume responsibility of work performed. 7. Owner and Contractor shall coordinate Schedule of Values, Application of Payment, Construction Cost and any other fees related to this project. CHANGE PROCEDURES: 1. Architect will submit Supplemental Instructions for minor changes. 2. Contractor may propose changes by submitting a request for change to Architect. Architect and Owner shall give written approval for all changes made by the Contractor. Commencement of the work without written approval from Architect and Owner, the contractor will assume responsibility of work performed. SUBMITTAL: 1. Prior to construction Architect and Owner shall submit a list, to the Contractor of required shop drawings submittals for this project. 2. Prior to construction Architect and Owner shall submit a list, to the Contractor of all required testing for this project. Contractor shall be responsible for the cost of any testing requested by the Owner. TEMPORARY FACILITIES: 1. Contractor shall provide and maintain access to the site of the project. 2. Contractor shall coordinate with Owner for temporary facilities requirements, if required for this project. 3. Contractor shall be responsible for maintaining a clean and safe construction site. 4. Contractor is responsible for the removal of all construction debris. MATERIALS: 1. Store and protect all project products and materials in accordance with manufacturer instructions. Products and materials of this project shall be installed free of damage. DESIGN PARAMETERS TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ai GROUND SNOW LOAD WIND DESIGN SEISMIC DESIGN CATEGORYf SUBJECT TO DAMAGE FROM WINTER DESIGN TEMPe ICE BARRIER UNDERLAYMENT REQUIREDh FLOOD HAZARDS9 AIR FREEZING INDEX' MEAN ANNUAL TEMPI Speedd Topographic Special wind Wind-borne Weathering a Frost line Termite (mph) effectsk region) debris zone`n depthb NA See Fig. R301.2(4) NA Negligible NA Very inside DB670- NA Flood Hazard: X NA NA Heavy Design TD: 28° For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The weathering column shall be filled in with the weathering index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2(3). The grade of masonry units shall be determined from ASTM C34, C55, C62, C73, C90, C 129, C 145, C216 or C652. b. Reserved. c. Termite infestation per Figure R301.2(6) is `Very heavy." d. Wind speed shall be from the basic wind speed map [Figure R301.2(4)]. Wind exposure category shall be determined on a site -specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Florida Building Code, Plumbing. Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official. f. Reserved. The applicable governing body shall, by local floodplain management ordinance, specify (a) the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the Flood Insurance Study and (c) the panel numbers and dates of the currently effective FIRMs and FBFMs or other flood hazard map adopted by the authority having jurisdiction, as amended. h. Reserved. i. Reserved. J. Reserved. k. Reserved. 1. Reserved. m. Reserved. PROJECT INFORMATION DESIGN PARAMETERS: Florida Building Code (7th Edition, 2020) Florida Residential Code (7th Edition, 2020) Florida Existing Building Code (7th Edition, 2020) Florida Plumbing Code (7th Edition, 2020) Florida Mechanical Code (7th Edition, 2020) Florida Fuel Gas Code (7th Edition, 2020) 2017 National Electric Code 2012 Florida Accessibility Code (7th Edition, 2020) Florida Energy Code (7th Edition, 2020) Florida Fire Prevention Code (7th Edition) Building Design: Ultimate Wind Speed: Nominal Wind Speed: Building Category: Wind Importance/Use Factor: Internal Pressure Coefficient: Building Mean Height: Roof Overhang: Roof Pitch: Garage Design Pressure: 120 sqft. Door Design Pressure: 50 sqft. Window Design Pressure: 20 sqft. Exposure: Design Loads: Impact Protection: nrrl IDAI\IrV- R3 One -Family Residence CONSTRUCTION: Enclosed 160 mph 3 second gust 124 mph II 1.0 +/-0.18 15'-6" 1,-4" 5/12 Int. Zone (+26.3/-29.3) Ext. Zone (+30.0/-36.7) Int. Zone (+31.6/-34.6) Ext. Zone (+31.6/-39.8) Int. Zone (+33.7/-36.7) Ext. Zone (+33.7/-44.0) C Roof Dead Load/Live Load: 15/40 psf Floor Dead Load/Live Load: 15/30 psf Impact Resistant Windows and Doors Type V Unprotected, Unsprinklered Ext. brg walls - CMU Pre -fabricated wood roof trusses Int walls -metal stds & drywall AREA TABULATIONS: (include exterior walls A/C space: 1,817.5 gross sqft. Garage: 469 gross sqft. Covered Patio: 240 gross sqft. Front Entry 72 gross sqft. Total New Bldg. Area: 2,598.5 gross sqft. Product Approval Submittal Affidavit Bldg Address: 4090 Sunrise Blvd Contractor: Homecrete Homes Opening Schedule: Swing Doors, Overhead Doors, Sliding Doors, Fixed Glass, Windows, & Skylights: FL# or Product Model # Manufacturer Glass Attachment Method Type, Building Design Product Design Miami -Dade Description Size, Spacing, & Embedment Pressure Pressure FL# 5823.2 SINGLE -HUNG 8100 Vinyl Custom Windows Impact Resistant Installation shall stricty adhere to product approval See Cover Sheet +67.5 / -70.0 WINDOW SH LOW E and Doors 7/8" thk Type 'A' FL# 5823.2 into 1X P.T. wood buck 270 Impact Anchors: 3/16" anchors @ Head, Sill and Jamb Attachment: Head/Sill - 6" max from corners Head/Sill - (1) @ mid -span Head/Sill - (2) @ 4" from center Jamb - 6" max from corners Jamb - 16-9/16" max O.C. Jamb - (1) @ center Embedment: 1-1/4" min into concrete thru 1X Use 3/16" dia. Elco Ultracon Anchors FL# 16177.1 SINGLE -HUNG 8100 Vinyl Custom Windows Impact Resistant Installation shall stricty adhere to product approval See Cover Sheet +70.0 / -70.0 WINDOW SH LOW E and Doors 7/8" thk Type 'A' FL# 16177.1 into 1X P.T. wood buck 270 Impact Anchors: 3/16" anchors @ Head, Sill and Jamb Attachment: Head - 6" max from corners Head - 17" max O.C. Sill - Not Required Jamb - 6" max from top corners Jamb - (2) at 4" O.C. from bot corners Jamb - 10-1/2" max O.C. Jamb - 4" either side from center Embedment: 1-1/4" min into concrete thru 1X Use 3/16" dia. Elco Ultracon Anchors FL # 20468.4 FIBERGLASS Smooth Star Thermatru Corp. N/A Tapcons shall be spaced as per product approval See Cover Sheet +67.0 / -67.0 ENTRY DOOR Opaque on Sheet 8 of 11 Anchors: 1/4" X 3" Tapcons @ Head and Jamb Buck Attachment: Head - 4" max from corners Jamb - 4" max from corners Jamb - 13.00" max O.C. Frame Attachment: Head - 6" max from corners Jamb - 6" max from corners Jamb-14.00" max O.C. FL# 20838.1 S.G.D. 8800 PVC Custom Windows Impact Resistant Installation shall stricty adhere to product approval See Cover Sheet +65.0 / -65.0 IMPACT SGD and Doors 1" Overall FL# 20838.1 into 2X P.T. wood buck Anchors: 3/16" anchors @ Head, Sill and Jamb Attachment: Head/Sill - 6" max from corners Head/Sill - (1) mid -span of panel Head/Sill - 4" either side from center Jamb - 6" max from corners Jamb - 21" max O.C. Buck Embedment: 1-1/2" min into concrete Use 1/4" dia. ITW Tapcons. 3" from corner, 8" o.c. stag. Window Embedment: 1-3/8" min into 2X Use #12 wood screw anchors FL# 16546.5 GARAGE CLOPAY CLOPAY N/A Attach track as per Product Approval and Track See Cover Sheet +36.0 / -42.0 DOOR MODEL 73 W6 Supplement Guide - Attach Buck W/ 5/8" 0 x 6" sleeve anchors @ 18" O.C. FL# 11602-R10 ROOF TITANIUM Owens Corning N/A Installation shall stricty adhere to product approval See Cover Sheet -45.0 UNDERLAYMENT ROOF Roofing and Asphalt FL# 11602-R10 UNDERLAYMENT PSU-30 Self -Adhered and back nailed 6" O.C. max with 12 ga. galvanized annular ring shank nails through 32 ga. 1-5/8"0 tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. Product Model # Manufacturer Attachment Method Type, Building Design Product Design Size, Spacing, & Embedment Pressure Pressure Mullions Tube Mullion Custom Windows 3" Tube Mullion - Installation shall strictly adhere See Cover Sheet +65.0 / -65.0 FL # 9520.1 and Doors to Product Approval FL# 9520.1 Use 3/16" dia. ITW Tapcons at each hole Provide a minimum of 1-1/4" embedment Roof 26 GA Extreme Provide #10 x 1-1/2" Hex -Washer Head wood screw See Cover Sheet N/A 5V-Crimp Metal Fabricators to penetrate 3/16" min. thru deck or 5/8" embedment Panel into wood plank FL # 17022.1 Siding Stucco - 5/8" Thick Light Textured Stucco on Typical Concrete Block Const. See Cover Sheet N/A Soffit Stucco - Stucco finish over high rib lathe See Cover Sheet N/A provide 7" x 24" soffit vents - refer to sheet S1 I have reviewed the above product approval information and and approved it. Name: Nicole L. Norton/n2 architecture + design Signature: Certification Number: AR 91827/ AA26002853 Date: INDEX OF DRAWINGS Revised 28-May-21 Sheet Sheet Title IS C1 Cover Sheet, General Information + Notes ■ ■ Al Floor Plan, Details + Notes ■ A2 Foundation Plan Details + Notes ■ A3 Building Elevations ■ S1 Roof Framing Plan ■ S2 Structural Details ■ ■ P1 Plumbing Plan, Schedules + Notes ■ E1 Electrical Plan Schedules + Notes ■ SYMBOLS Nicole L Digitally signe( • Nicole L. Norto O Window Q DetailNorton ## Door ## Keyed Note Ex] Room Name XX.X Interior Elevation O Wall Type XX.X Exterior Elevation AX.X Wall Section AX.X Building Section 0 Revision 0 Miscellaneous Key PROJECT CONTACTS OWNER/CONTRACTOR: Homecrete Homes Robert Cenk 2162 NW Reserve Park Trace Port St Lucie, Florida 34986 (772) 873-6707 ARCHITECT: n2 architecture + design Niki L. Norton, R.A. 2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 (772) 220-4411 uate: 2w-wb. 09:21:22 -04'01 C t O C U O} N w T } U u) L O L i O O C O Q O C a 3 0 �t +� O N L O w O L to i "O a-+ O cn rp -0 M ui N ❑- o Tvui +' C OLL 01 fo N � _T >L L > Q �'m���3 o, „ n 3 ^ 2 1 �' U U 3 U U 0 0 CL 1) L a }' 7 C -0M C U C C U U Q ou Q 6 E a Q 4i= U Iy cM O (n 64 LJL N U) �� C v cc -� �CU 0�� L w E� E o + O N U U N U s_ (6 pt L NOR7- 7�' a AR91827 signed ano Sealed by fVl{DLI: NORTON, K LFED AP using a Digital. 5ignatineand Date. Printed Copies are nca considered stgned and sealed and ehe signature most be verified on any elecVonfc coplts- W U U L IN 00 LL �I M _ (n Vw I (10 `, (3)_ V L.L O 00 2LL 110 I U �.�00 L (5 Lna� fU E C:L N 1 ` _ U0 U_ Rev. # Date 28-May-21 Building Dept. Comments Project Number 21-0711 Status CD Issue date 01-Apr-21 Sheet C 1 Cover Sheet U_ 0 a a� 0 Q Q 0 Ln 0 a; N 0 00 0 N L L!1 7 N N Lr, CD w PLYWOOD EDGE 161 1•1 1061 1 1 1e1 • • • • • • • • •• • • • • • • • 19/32" THK EXT. PLYWOOD SHEATHING EXPOSURE 'C' - 160 MPH WIND SPEED I. •• FASTENERS (RING SHANK NAILS): •• • ASTM F1667 RSRS-03 (2-1/2" X 0.131") EDGE OF WALL ASTM F1667 RSRS-04 (3" X 0.120") BELOW • .. NAILING PATTERN: .. • RAFTER/TRUSS SG = 0.42 - 4" O.C. EDGE & FIELD • RAFTER/TRUSS SG = 0.49 - 6" O.C. EDGE & FIELD ROO.. '� @ 2JO ISTS .. . .. . . . . .lei . . . . .lei. . . . . . ... . . . . EDGE OF ROOF @ OVER HANG 1 - ROOF PLYWOOD SHEATHING NAILING PATTERN 2 - ARCH DETAIL #5 CORNER BAR WITH SCALE: 3/4" = 1'-0" 15" MINIMUM OVERLAP #5 VERTICAL REINF. (TYP) #5 HORIZONTAL REINF. (TYP) Ar 1 1 CORNER BAR 3 - BLOCK TRANSITION DETAIL 2 -WIND LOADING DIAGRAM SCALE: 3/4" = 1'-0" FAI O 20 SQFT +17.8/-32.8 50 SQFT +14.0/-27.2 100 SQFT +11.2/-22.9 O 20 SQFT +17.8/-45.6 50 SQFT +14.0/-38.4 100 SQFT +11.2/-33.0 +20.6/-51.0 VALUES BASED ON TABLE R301.2(2) - FBCR 2020, 7TH EDITION SCALE : NTS 8" CMU WALL VERTICAL STEEL REINFORCING HORIZONTAL STEEL REINFORCING WINDOW AS PER SCHEDULE WINDOW AS PER SCHEDULE CAULK AT FRAME CONT. FLUID APPLIED WATER PROOFING/FLASHING AT ALL OPENINGS (TYP.) SHALL COMPLY WITH AAMA 714 REFER TO FBC R703.4 PRE -CAST CONCRETE WINDOW SILL 8" CMU WALL VERTICAL STEEL REINFORCING WINDOW AS PER SCHEDULE 8" CMU WALL VERTICAL STEEL REINFORCING SILL WINDOW )OD BUCK W/ LIQUID AS PER FBC AS PER )DUCT APPROVAL 3 FASTENER AS PER N.O.A./PRODUCT APPROVAL SEE NOTES FASTENER AS PER N.O.A./PRODUCT APPROVAL SEE NOTES 1X P.T. WOOD BUCK W/ LIQUID FLASHING AS PER FBC 5 - WINDOW H-S-1 DETAIL 2" SCALE: 1-1/2" = V-0" 36" HIGH BY 2" DIAMETER STEEL CRASH POST FLOOR FLANGE W/ (4) 3/8" EXPANSION BOLTS INTO SLAB 7 -CRASH POST DETAIL SCALE: 1-1/2" = 1'-0" DOOR AND WINDOW ATTACHMENTS SINGLE -HUNG SINGLE -HUNG FRONT ENTRY S.G.D. DOOR Instal ation shall stricty adhere to product approval lM.2 Installation shall stricty adhere to product approval Tapcons shall be spaced as per product approval Installation shall stricty adhere to product approval FL# 5into 1X P.T. wood buck FL# 16177.1 into 1X P.T. wood buck on Sheet 8 of 11 FL# 20838.1 into 2X P.T. wood buck Anchors: 3/16" anchors @ Head, Sill and Jamb Anchors: 3/16" anchors @ Head, Sill and Jamb Anchors: 1/4" X 3" Tapcons @ Head and Jamb Anchors: 3/16" anchors @ Head, Sill and Jamb Attachment: Head/Sill - 6" max from corners Attachment: Head - 6" max from corners Buck Attachment: Head 4" max from corners Attachment: Head/Sill - 6" max from corners Head/Sill - (1) @mid -span Head - max O.C. Jamb - 4" max from corners Head/Sill - (1) mid -span of panel Head/Sill - (2) @ 4" from center Sill -Not Required t R Jamb - 13.00" max O.C. Head/Sill - 4" either side from center Jamb - 6" max from corners Jamb - 6" max from top corners Jamb - 6" max from corners Jamb - 16-9/16" max O.C. Jamb - (2) at 4" O.C. from bot corners Frame Attachment: Head - 6" max from corners Jamb - 21" max O.C. Jamb - (1) @ center Jamb - 10-1/2" max O.C. Jamb - 6" max from corners Embedment: 1-1/4" min into concrete thru 1X Jamb - 4" either side from center Jamb-14.00' max O.C. Buck Embedment: 1-1/2" min into concrete Use 3/16" dia. Elco Ultracon Anchors Use 1/4" dia. ITW Tapcons. 3" from corner, 8" o.c. stag. Embedment: 1-1/4" min into concrete thru 1X Use 3/16" dia. Elco Ultracon Anchors Window Embedment: 1-3/8" min into 2X Use #12 wood screw anchors NFnn 8" CMU WALL VERTICAL STEEL REINFORCING HORIZONTAL STEEL REINFORCING CAULK AT FRAME CONT. DOOR AS PER SCHEDULE EXTERIOR DOOR AS PER SCHEDULE CAULK AT FRAME CONT. FLUID APPLIED WATER PROOFING/FLASHING AT ALL OPENINGS (TYP.) SHALL COMPLY WITH AAMA 714 REFER TO FBC R703.4 8" CMU WALL VERTICAL STEEL REINFORCING SILL DOOR AS PER SCHEDULE 6 - DOOR H-S-J DETAILS 2X P.T. WOOD BUCK W/ LIQUID FLASHING PER FBC FASTENER AS PER N.O.A./PRODUCT APPROVAL SEE NOTES INTERIOR FASTENER AS PER N.O.A./PRODUCT APPROVAL SEE NOTES 2X P.T. WOOD BUCK W/ LIQUID FLASHING PER FBC INSTALL THRESHOLD AS PER N.O.A./PRODUCT APPROVAL - SEE NOTES FASTENER AS PER N.O.A./PRODUCT APPROVAL SEE NOTES BOND BEAMS AS PER SCHEDULE �12'-8" TRUSS BRG HORIZONTAL REINFORCING SHALL BEND AND TURN INTO BEAMS AS SHOWN 10'-0" TRUSS BRG PRECAST LINTEL AS PER SCHEDULE STUCCO CEILING FINISH SEE NOTE BELOW #5 BARS AT 24" O.C. HOOKED TOP & BOT. BOND BEAMS AS PER SCHEDULE PRECAST LINTEL AS PER SCHEDULE #5 VERTICAL REINFORCING SHALL HOOK INTO FOUNDATION BELOW AND BEAM ABOVE 8" CMU WALL �o -0' TOP OF SLAB 8" CMU WALL VERTICAL STEEL REINFORCING HORIZONTAL STEEL REINFORCING CAULK AT FRAME CONT. DOOR AS PER SCHEDULE EXTERIOR DOOR AS PER SCHEDULE CAULK AT FRAME CONT. FLUID APPLIED WATER PROOFING/FLASHING AT ALL OPENINGS (TYP.) SHALL COMPLY WITH AAMA 714 REFER TO FBC R703.4 8" CMU WALL VERTICAL STEEL REINFORCING DOOR AS PER SCHEDULE NFnn SILL 2X P.T. WOOD BUCK W/ LIQUID FLASHING PER FBC FASTENER AS PER N.O.A./PRODUCT APPROVAL SEE NOTES INTERIOR FASTENER AS PER N.O.A./PRODUCT APPROVAL SEE NOTES 2X P.T. WOOD BUCK W/ LIQUID FLASHING PER FBC INSTALL THRESHOLD AS PER N.O.A./PRODUCT APPROVAL - SEE NOTES FASTENER AS PER N.O.A./PRODUCT APPROVAL SEE NOTES SCALE: 1-1/2" = 1'-0" �i t'--—————— - ———— I 'i i r r r r r •- --- ----a--- ---------' r � r � � •'--- - - - - -'------' -a 1----6 e - --------------i�ia/�i/,/�i/ / NOTE: ASTM C 1063, 7.10.2.3: EXPANDED 3/8" (9.51MM) RIB LATHE SHALL BE ATTACHED TO HORIZONTAL AND VERTICAL WOOD FRAMING MEMBERS WITH NAILS OR STAPLES TO PROVIDE NOT LESS THAT 1-3/4" (44.5 MM) PENETRATION INTO HORIZONTAL WOOD FRAMING MEMBERS, AND 3/4" (19.1 MM) PENETRATION INTO VERTICAL WOOD FRAMING MEMBERS. 9 - SECTION AT FRONT ENTRY SCALE: 1/2" = 1'-0" C t O C U O} N T } U 0 s o - c o ( W - c L � 3 (0,cQ s +� CL N L O w O L L 7 fl O C N O aO'' C C-: 'U" '0' 21 L ra fu o"3' �% -0 L c c O c O N _T >L 0-0 L f -0> Q 3 _21 .3 N o iEC: u' 0—C ru U 3 ? 3 u pY aCU C U C C U U Q ouQ-a Eaw (n N - LJL U) N > If N L L c v cis �04 0) U ID .O .U) L O LU U) E — E O + O N U G� U L CIO Of FL O y< AR91827 ED signed ano sealed by NICOLE NORTON, PA, LEER AP using a Digital Signature and Date. Printed Copies are not ccnstcl�ered stigned and sealed and ehe signature must be verified on arty elmmonic Copies- U V L -0 00 I M •� fl) L.L O 0 O = -0 I (3) N ! Co Q L L U N a) 00 .-. E L N0 ON Rev. # Date 28-May-21 Building Dept. Comments Project Number 21-0711 Status CD Issue date 01-Apr-21 Sheet S2 Structural Details