Loading...
HomeMy WebLinkAboutAPPROVED TRUSSLYTTag line =LIFE SAFETY WARNING This symbol identifies Life Saiety Warnings that should be read and given spe..ial attention to all persons installing Trusses. SPACING NOTE All trusses are to be s(;t 2`-0" on center except as Doted. MULTIPLE PLY TRUSSES MU37 BE FASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWING ,A TO DETERMINE fF MULTIPLE PLY. A • DON'T LIFT TRUSSUS WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' SDdn or less 60 degrees or less I s I Bar v 7notmatch. �� NO, Nwe E` 112 span Tag iirn Fr4x 213 to �-.+� 1 approx. 112 yr Span. REFER TO BCREFER TO SCSI Truss must be set this way it Truss must be set this way if crane is used. Truss is an example, your trusTruss is an example, your truss may not match. Insist crane operator sets truss this way. Insist crane operator sets truss this way. All load bearing wC.11s, headers, beams, & lintels must be In place at indicated height before trusses are installed. A I • AIR HANDLER NOTE Unless noted elsewhere on this layout, these trusses are not designed for air handlers in the r)of or for any other A/C requirements. This may be in conflict with building code and A/C Design requirements. Consult with B .gilding Department and A/C Contracto WARNING ! The size of these trusses makes it necessary t iat they a set by a profeesional builder familiar with and experienced in the problems ar d dangers of setting large span trusses. The builder and erector should consult with an Ingineer licensed in Florida specializing in wood roof trusses about the safe erection of t iese trusses. The engineer should be at the job site when trusses are erected tc provide supervision and advice. REPRESENTS THE LEFT SIDE OF EACH TRUSS DRAWING SEAT PLATES BY CF:AMBERS TRUSS REPRESENTS A HANGER HANGER SCHEDULE USE HUS26 FOR 2X4, SUH46 FOR 4X2 Ek CEPT AS SHOWN CARRIED TRUSS CARRYING TRUSS HANGER ID FASTENER FOR CARRIED 1 7USS FASTENER FOR CARRYING TRUSS "'Please refer to Standard Engineering package for general nstuction on installing hangers I Gd=D.148" x 3" 16d-0.162" x 3 1 2" Hatch Leaend CEILING AT 10'-8" CEILING AT 1 T-4" LOAD BEARING +t AT 10'-0" LOAD BEARING AT 12'-8" HIP VALLEYS ARE DIFFICULT TO INSTALL, PROBLEMS CAN BE ADDRESSED BY CUTTING HIP VALLEYS IN HALF & FINDING CORRECT LOCATION. Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers !! &ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 28' - WIN LENGTH!! 55-06-00 viir re. ii r o rrr�vs.� vdir s sss�srve�, if sa. rirsiiv�i� M IN alb e,� ---- it i..rr i i JIM Mimi ILI VIN 1 i I NIL .1 r� o �p .■��rii��ii iaviv ��isriiiyiivir is NIM Ell IR, Ns t %/1d. Mimi . . . . . . . ...... NOTES: " ALL B�AMS ARE BY OTHERS. * BUILD R TO UNDER FRAME CEILINGS AS NEEDED. i HIP CARRIER LOCATED AS DIMENSIONED ON KAYO LIT I v F WRNDER JACZ{B ARE NOT BEV-' EO. SEE STANDARD �. ENGUEERING. Oar c�vU� N 24^ O.C, THRu CORNER JACKS ONLY 24" i' T-11ta CORNER DETAIL OVERHANGS NOT SHOWN FOR CLARITY (PLUMB CUT END 2X4 TOP CHORD WALL HEIGHT VARIES END DETAIL: TYPICAL 4-0t M 12 5r FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT iS SIGNET} & RETURNED The undersigned acknowledges and agrees: 1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for determining successful fabrication of the trusses. 2. All dimensions in this layout have been verified by t'1e undersigned. 3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the undersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss shall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option. After 10 days of delivery remedy will be according to Florida statute 558. 4. The undersigned acknowledges receipt of "BCSI" summary sheet by TPI & WTCA 5. Delivery is to job site, It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has the sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will be responsible for dump delivery only. The buyer iS responsible for additional delivery expenses if Chambers Truss has to redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses Buyer is .responsible to Chambers Truss for towing costs due to site conditions. 6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour fee for revisions may be charged by Chambers Truss. 7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price. Invoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of delivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss reasonable attorneys fee for collections in event of payment not timely made. 1-1I2 % per month service charge will be added for all sums not paid within terms. 8. Signature oT initials anywhere on this sheet constitutes agreement to all terms herein. 9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees payment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the undersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the recipient. 10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to herein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida. 11. Design responsibilities are per IoNafional Standard And Recommended Guidelines On Responsibilities For Construction Using Metal Plate Connected WoDd Trusses ANSIITP11WTCA 4 - 2002-01 12, Warranty is per Chambers Truss Warranty attached. :DATED SIGNED FOR _ _TITLE A spreader bar may be required per "BCSI" to prevent injury I& damage. Multiple ply trusses must be fastened together per engineering before they are set, failure to do so can result in roof collapse. Temporary and permanent bracing are equired and can save life an property and is the responsibility of the truss erector. Study the contents of the information packet included on delivery before setting trusses. Trusses must be set and braced per design to prevent injury & damage. Trusses must be set plumb and square Do not set bunks or stack of plywood, roofing material or any other concentrated loads on trusses, this can cause collapse. DO NOT INSTALL TRUSSES USING THIS USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS INC i can er Avenue Fort Pierce, Florida 34982.6423 800.551.5932 Fort Pierce 772.465.2012 Fax 772-465.8711 Vero Beach 772.569-2012 Stuart 772-286-3302 Web Site: CHAMBERSTRUSS.COM Email: MAIL@CHAMBERSTRUSS.COM O NA CTED O 4REVIEWED AS #TOTED O REVISE AND RE•smrr ARCHITECT Ej Zca�oZl MrrEiC VERSION 74-1-4M LOADINGWESIGN CRITERIA REDUCIBLE DESIGN CRITERIA PER CODE SUCH AS SIBC 1604,6.1 County ST. LUCK Building Department ST. LUCIE COUNTY Wind Design Criteria ASCE 2010 Wind Design Method MWFRS(Directianal)1C-C hybrid Wind ASCE 7-16 Roofing Material Shingle or Shake Loading in PSF Roof R.D.L. Floor Top Chord Live 20 0 Top Chord Dead 7 4.2 0 Bottom Chord Live '10-Non Conccurent D Bottom Chord Dead 10 3 0 Total Load 47 7.2 0 Duration Factor 1.25 0 Wind Speed 160mph Top Chord C.B. Sheathing by builder Bottom Chord C.B. Sheathing by builder Highest Mean Height 15-15" Building Type Enclosed Building Category 11: Non Restrictive Exposure Category C>Open Terrain with scattered obstructions Miles from Ocean 5 Conforms to Florida Building Code 2020 R.D.L.=Restraining Dead Load C-B.=Continuous Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Engineer of Record Chambers Truss Inc. Drawing Name: 77373 SCALE: 114" = 1'-0" 149 total trusses, 48 unique designs Designer: RLC Reviewed by: RLC Date: 03/25/21 FOR HOMECRETE HOMES INC. DESCRIPTION: 40*90 SUNRISE/ MARSAN Page 1 of 1 CUSTOMER INITIALS EACH PAGE 77373