Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Design Pressure Report ( Jerilyn Wilson) - Galeforce Hurricane Shutters
06Ad& I'da W&UAPrce HURRICANE SHUTTERS, INC. PANELS • ACCORDIONS • BAHAMAS COLONIALS • ROLL UPS Property Information Building Information Owner: Jerilyn Wilson Wind Zone: 170 MPH. Address: 7752 Greenbrier Cir Exposure Category: B Port St Lucie,FL 34986 Minimum Building Dimension: 5 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 7 0.0 0.0 2 Int 59.5 61 7 29.3 -31.9 3 Int 62.75 69 7 28.9 -31.6 4 Int 85.5 69 7 28.3 -31.0 5 Int 62.75 69 7 28.9 -31.6 6 Int 43.25 69 7 29.7 -32.3 7 Int 62.75 69 7 28.9 -31.6 8 Int 43.25 69 7 29.7 -32.3 9 Int 0 0 7 29.7 -32.3 10 Int 43.25 69 7 29.7 -32.3 11 Int 62.75 69 7 28.9 -31.6 12 Int 43.25 69 7 29.7 -32.3 13 Int 43.25 78 7 29.4 -32.1 14 Int 43.25 57 7 30.1 -32.7 15 Int 43.25 69 7 29.7 -32.3 16 Int 7 29.7 -32.3 17 Int 43.25 69 7 29.7 -32.3 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page 1 of 1