Loading...
HomeMy WebLinkAboutHealth Dept FinalSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Steven Dunn AGENT: Brian Davis Septic PROPERTY ADDRESS: TBD Slash Pine Trl Fort Pierce, FL 34951 APPLICATION #:AP1452309 PERMIT #:56-SF-2015031 DOCUMENT # : FI 1647164 DATE PAID:' 1/08/2019 FEE PAID:430.00 RECEIPT #:56-PID-4228191 LOT: BLOCK: SUBDIVISION: ID# : 1407-342-0025-000-4 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [21 [ ] [27] SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [281 DITCHES 49 FT [ ] [031 OUTLET DEVICE [ ] [29] PRIVATE WELLS 88 FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11DC4 2. [ ] (321 POTABLE WATER 51 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 7 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 22 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [11 509.4 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 8.00 2. [ ] [38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 06/17/2021 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 2.00 [ ] [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [181 DOSING PUMPS [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [47] CONTRACTOR Brian Davis (Brian Davis Sept [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. 1 CONSTRUCTION I APPROVED / r St. Lucie CHD DISAPPROVED Envira mental Specialist IIOan J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ AppgOVED / DISAPPROVED ]: St. Lucie CHD Environmental Specialist Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1452309 EID2015031 DATE: 11 /17/2020 DATE: 06/17/2021 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1452309 PERMIT #:56-SF-2015031 DOCUMENT #:F11647164 DATE PAID :11 /08/2019 FEE PAID:430.00 RECEIPT #:56-PID-4228191 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST, filter, and 5x6+3x5 long BED DF installed. No violations, system ok to cover. Contractor notified via email. Well inspected at construction inspection. Needs final inspection for mound system and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1452309 EID2015031