Loading...
HomeMy WebLinkAboutAPPROVED Design Pressure Report ( Jerilyn Wilson) - Galeforce Hurricane ShuttersProperty Information Owner: Jerilyn Wilson Address: 7752 Greenbrier Cir Port St Lucie, FL 34986 Building Information Wind Zone:170 MPH. Exposure Category:B Minimum Building Dimension:5 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 7 0.0 0.0 2 Int 59.5 61 7 29.3 -31.9 3 Int 62.75 69 7 28.9 -31.6 4 Int 85.5 69 7 28.3 -31.0 5 Int 62.75 69 7 28.9 -31.6 6 Int 43.25 69 7 29.7 -32.3 7 Int 62.75 69 7 28.9 -31.6 8 Int 43.25 69 7 29.7 -32.3 9 Int 0 0 7 29.7 -32.3 10 Int 43.25 69 7 29.7 -32.3 11 Int 62.75 69 7 28.9 -31.6 12 Int 43.25 69 7 29.7 -32.3 13 Int 43.25 78 7 29.4 -32.1 14 Int 43.25 57 7 30.1 -32.7 15 Int 43.25 69 7 29.7 -32.3 16 Int 7 29.7 -32.3 17 Int 43.25 69 7 29.7 -32.3 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1