Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED A-7 Rev1
FA 5 5 4 4 , 5><><>< 5 ALLOWABLE PRESSURES ARE FOR WINDOWS AND DOORS, FRAMING, ROOFING AND OTHER �0 BUILDING COMPONENTS AND CLADDING. ROOF ZONES: 1 THRU 3 WALL ZONES: 4 AND 5 W*1 n d Z o n e s WCHS PRODUCT APPROVAL Approval Number Product Model Number Manufacturer Glass Type Attachment Method Building Rated Design Pressures Product Rated Design Pressures N A 2 -061 .0 S 'n D ron Estate WINDOOR 6" from ends and 24" o.c. e h' e +/- 90 NOA# 20-0814.03 SGD Series 8100 WINDOOR Impact (3)-1/4" x 1 1 /4" min embedment Tapcon anchors C�? 16" o.c. max. See This Sheet 70 NOA# 20-0722.16 Swing Door eries 60 CGI Impact n i o X d u s 1- ed e t into concre e. 6 max at Jambs 3 Max at corners 6 max at head and sills See This Sheet + -80 1 NOA# 20-0519.14 Fixed Window Series 238 WINDOOR Impact 1 4 Tapcons into 1x bucks or masonry w 1-1 4 minimum embedment 6" max ©Corners 8c 17" max © Jambs 18" max Head and Sill See This Sheet 63.2 NOA# 20-0519.09 Fixed Window Series 130 WINDOOR Impact 1/4" Tapcons into 1 Bucks w 1-1 4 Min Embedment into Concrete„ & 6" Max at Corners, 16" Max. Straight Sides and 16 max To and Bottom Straight Sides See This Sheet +/-80 1/4" Tapcons into 1" Bucks w/1-1/4" Min Embedment NOA# 20-0722.09 Single Hung Series 110 WINDOOR Impact into Concrete & 5-1 /2" Max at Corners, 13-1 /2" Max. at Jambs 10 Max at Stiles 8c 20-9 16 Max Head and Sill See This Sheet +/- 75 /4" Elco Crete -flex ss4 t\Thru 1" Bucks w/Min Embedment FL#: 261.1 Mullion Standard Mullion PGT Impact f 1-14 into concrete 8c 2-1/2" Mi �dqe Distance with 4-3/4' separation at Head and 2-1 %2 Min Edge Distance See This Sheet +/- 70.0 Minimum and 4-13/16" & 4-15/32" seperation WIND DESIGN PRESSURES END WIND TRIB. ZONES - PSF 1 2 3 4 5 ZONE SPEED AREA <10 S.F. -30.6 -53.8 -78.8 +33.5 +33.5 -36.3 -44.8 20 S.F. -29.8 -49.0 -73.6 +31.9 +31.9 4 FT. 160 -34.8 -41.8 50 S.F. -28.6 -43.3 -66.9 +29.9 -32.7 +29.9 -37.8 MPH 100 S.F. -27.7 -39.1 -61.8 +28.5 +28,5 -31.3 -34.8 500 S.F. +24.9 +24.9 -27.7 -27.7 ,,>> SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN I. MASKOL FL PE #66080 Brian Digitally signed by Brian Maskol, Maskol P.E. i Date: E P.E. P 2021.06.25 • • 10:03:41-04'00' Ln z w z � O o a � � z w U w � o a a w 0 z 0 J_ Z) co N � Q O Z O U w w z Qw ��LL Q0 0�� _j w�U °C 0 � oo J _j�Q Q CL 0 N 0 z Q� _jQ Q= > U 0 w °C z a0 Q N U D 0 0 DATE DESIGNED BIM 03-01-21 DRAWN MIN 03-01-21 CHECKED JOB NO. 2021-030 A�7