HomeMy WebLinkAboutAPPROVED Juan Pablo Calderon Residence - Shop Drawings (6-2-2021)DRAWNDRAWING TITLEDATECHECKED BYSHEETREV BYDATE DESCRIPTION05.10.2021SD-0.06/2/2021 10:00 AMs:\sde's\2021\residential\04.26.2021 - jp calderon\dwg\juan pablo calderon residence.dwg
4851 N.W. 36th AVE.MIAMI, FL 33142O: 305.269.3999F: 305.260.5114WWW.READYWINDOWS.COMPROJECT NAME:
LOCATION:
JUAN PABLO CALDERON RESIDENCE
4100 N. HIGHWAY A1A.
HUTCHINSON ISLAND, FL 34949SCALEPROJECT No:21-174-NO-JUAN PABLOCALDERONRESIDENCEDHNOSHOP DRAWING CHECKED FOR STRUCTURALREQUIREMENTS ONLY.WIMAL SUARIS, P.E.DLG ENGINEERINGFLA. P.E. # 37369CA #28476COVER SHEETJUAN PABLO CALDERON RESIDENCE4100 N. HIGHWAY A1A.HUTCHINSON ISLAND, FL 34949.1.E.S. WINDOWS - SERIES "EL100" ALUMINUM SINGLEHUNG WINDOW- L.M.I.FL#. 22250.1GLAZED WITH LAMINATED GLASS TYPE "1i", COMPOSED OF:1/8" CLEAR TEMPERED GLASS SB703/8" AIR SPACE1/8" CLEAR HEAT STREN'D GLASS0.090" CLEAR INTERLAYER TROSIFOL PVB BY 'KURARAYAMERICA, INC'1/8" BRONZE HEAT STREN'D GLASSAND1/8" BRONZE TEMPERED GLASS3/8" AIR SPACE1/8" CLEAR HEAT STREN'D GLASS0.090" CLEAR INTERLAYER TROSIFOL PVB BY 'KURARAYAMERICA, INC'1/8" CLEAR HEAT STREN'D GLASS2.E.S. WINDOWS - SERIES "EL300" ALUMINUM OUTSWINGENTRANCE DOOR- L.M.I.FL# 22551.1GLAZED WITH LAMINATED GLASS TYPE "A1", COMPOSED OF:3/16" CLEAR HEAT STREN'D GLASS SB703/8" AIR SPACE3/16" CLEAR HEAT STREN'D GLASS0.090" CLEAR INTERLAYER TROSIFOL PVB BY 'KURARAYAMERICA, INC'3/16" BRONZE HEAT STREN'D GLASSAND3/16" BRONZE HEAT STREN'D GLASS3/8" AIR SPACE3/16" CLEAR HEAT STREN'D GLASS0.090" TRANSLUCENT WHITE INTERLAYER TROSIFOL PVB BY'KURARAY AMERICA, INC'3/16" CLEAR HEAT STREN'D GLASS3.E.S. WINDOWS - SERIES "EL400" ALUMINUM SLIDINGGLASS DOOR - L.M.I.NOA No.20-1118.06GLAZED WITH LAMINATED GLASS TYPE "A1", COMPOSED OF:3/16" BRONZE TEMPERED GLASS3/8" AIR SPACE3/16" CLEAR HEAT STREN'D GLASS0.090" CLEAR INTERLAYER TROSIFOL PVB BY 'KURARAYAMERICA, INC'3/16" CLEAR HEAT STREN'D GLASS4.E.S. WINDOWS - CLIPPED, EXTRUDED ALUMINUM TUBEMULLION - L.M.I.NOA No. 20-1118.13N.T.S.INDEX OF DRAWINGS:SD-0.0COVER SHEETSD-1.0 APT #334 ENLARGED FLOOR PLAN (LEVEL 3)SD-2.0 WINDOW & DOOR SCHEDULEGENERAL NOTES:1.ANCHOR SHOULD BE AS LISTED, SPACED AS PER PRODUCT APPROVALEMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING ORSTUCCO2.ALUMINUM SURFACES IN CONTACT WITH LIME-MORTAR, CONCRETE, OROTHER MASONRY MATERIALS SHALL BE PROTECTED WITH ANALKALI-RESISTANT COATING, SUCH AS HEAVY - BODIED BITUMINOUSPAINT OR WEATHER WHITE METHACRYLATE LACQUER.3.ALL STEEL IN CONTACT WITH ALUMINUM TO BE PAINTED OR PLATED.4.EXISTING STRUCTURE MUST SUPPORT THE LOADS IMPOSED BY GLAZINGSYSTEMS.5.EXTERIOR PERIMETER CAULKING INCLUDED. INTERIOR CAULKING NOT BYREADY WINDOW.6.INTERIOR WINDOWS OR DOORS ARE NOT INCLUDED, UNLESS OTHERWISENOTED.7.DIMENSIONS SHOWN ARE NOMINAL, GLAZING FABRICATOR TO OBTAINFIELD DIMENSIONS PRIOR TO FABRICATION.8.SCOPE IS LIMITED TO GLAZING PRODUCTS AND ANCHORAGEVERIFICATION.9.GLASS COLOR SHALL BE CLEAR SB70 & BRONZE.10.ALUMINUM FINISH WILL BE DURANAR BERMUDA BRONZE .11.WOOD BUCKS TO BE 1X OR 2X FULL DEPTH OF GLAZING FRAMES TOSUBSTRATE AS FOLLOWS: 1/4" TAPCON WITH 1-1/4" EMBEDMENT AT 12"O.C. INTO CONCRETE OR #14 SMS/TEKS AT 12" O.C. INTO METAL. PROVIDECLUSTER OF (2) AT JAMB ENDS AND EACH SIDE OF MULLION, AND MUSTADHERE TO EDGE DISTANCE AND SPACING LIMITATIONS. ALLOW 2-1/2" MIN.SPACING BETWEEN WOOD BUCK CONNECTION ANCHORS AND ANCHORSUSED TO CONNECT GLAZING SYSTEM TO THE SUBSTRATE.12.ALL WINDOW OPENINGS IDENTIFIED AS EGRESS SHALL BEUNOBSTRUCTED AND SHALL HAVE A MINIMUM NET CLEAR OPENINGHEIGHT OF 24", A NET CLEAR OPENING WIDTH OF 20" AND A MINIMUM NETCLEAR OPENING AREA 5.7 S.F. (5.0 S.F. FOR GRADE LEVEL WINDOWS).13.ALL EGRESS WINDOWS SHALL HAVE A SILL HEIGHT NOT TO EXCEED 44"ABOVE FINISHED FLOOR.14.ALL WINDOWS SHALL NOT HAVE A SILL HEIGHT LESS THAN 36" ABOVEFINISHED FLOOR, UNLESS A CODE APPROVED PROTECTIVE BARRIER ISPROVIDED (BY OTHERS).15.IT IS THE EXCLUSIVE RESPONSABILITY OF THE WINDOW COMPANY TOPROVIDE PRODUCTS THAT MEET OR EXCEED THE ENERGY VALUESMANDATED BY THE STATE OF FLORIDA. COMPLIANCE WITH ENERGYREQUIREMENT IS BEYOND THE SCOPE OF THESE DRAWINGS.16.ALL SHIMS TO BE AS PER PRODUCT APPROVAL.17.G.C. TO PROVIDE OR REPLACE FIRE PROTECTION ON ALL STRUCTURALMEMBER, NEW AND EXISTING, AS NECESSARY, TO MEET FIRE RATINGREQUIREMENTS BY APPLICABLE CODES.18.G.C. IS RESPONSIBLE TO VERIFY THAT THE SUBSTRATES MEET THEREQUIREMENTS SPECIFIED IN PRODUCT APPROVALS AND DETAILS INTHESE DRAWINGS.WIND LOADS BASED ON THEFOLLOWING DESIGN CRITERIA:·ALL WIND PRESSURES ARE BASED ON ASCE 7-16 (FBC2020)·RISK CATEGORY= II·EXPOSURE = D·WIND VELOCITY 160 MPH (124 MPH SERVICE)·MEAN ROOF HEIGHT = 57 FT·Kd = 0.85LARGE MISSILE IMPACT RESISTANCE PRODUCTS (L.M.I):
GENERAL NOTES:1.G.C. TO VERIFY ALL M.O. DIMENSIONS2.FOR GENERAL NOTES REFER TO SHEET SD-0.03.ONLY LABELED DOORS AND WINDOWS ARE PART OF THIS PERMITLEGEND WINDOW ABOVE MARK SLIDING GLASS DOOR MARK OUTSWING DOOR MARK WIND ZONE 5 (a=110") WINDOW MARK SGD -DR ---TOPBALCONYABHMULLFEDHMULLGXDR 1SGD 3W.I.C.LIVING ROOMDINING ROOMKITCHENMASTERBEDROOMMASTERBATHROOMBEDROOM #2BEDROOM #3BATHBATHXDR 2SCALE: N.TS.APT#334 ENLARGED FLOOR PLAN (LEVEL 3)CEGRESSEGRESSEGRESSAPT #334 ENLARGEDFLOOR PLAN (LEVEL 3)DRAWNDRAWING TITLEDATECHECKED BYSHEETREV BYDATE DESCRIPTION05.10.2021SD-1.06/2/2021 10:00 AMs:\sde's\2021\residential\04.26.2021 - jp calderon\dwg\juan pablo calderon residence.dwg
4851 N.W. 36th AVE.MIAMI, FL 33142O: 305.269.3999F: 305.260.5114WWW.READYWINDOWS.COMPROJECT NAME:
LOCATION:
JUAN PABLO CALDERON RESIDENCE
4100 N. HIGHWAY A1A.
HUTCHINSON ISLAND, FL 34949SCALEPROJECT No:21-174-NO-JUAN PABLOCALDERONRESIDENCEDHNOSHOP DRAWING CHECKED FOR STRUCTURALREQUIREMENTS ONLY.WIMAL SUARIS, P.E.DLG ENGINEERINGFLA. P.E. # 37369CA #28476N.T.S.
WINDOW & DOOR SCHEDULEMARKQUANTITYGLASSTYPEFRAME SIZEZONEALLOWABLELOADSDESIGN LOADSPRODUCT DESCRIPTIONNOA No.FL No.REMARKS+PSF-PSF+PSF-PSFA11i37" X 72 38"560.080.046.962.5SERIES "EL100" ALUMINUM SINGLE HUNGWINDOW - L.M.I22250.1OXSB70EGRESSB137" X 72 38"560.080.046.962.5OXSB70EGRESSC137" X 72 38"560.080.046.962.5OXSB70EGRESSDEGRESS137" X 72 38"460.080.046.950.8OXSB70EGRESSEEGRESS137" X 72 38"460.080.046.950.8OXSB70EGRESSFEGRESS137" X 72 38"560.080.046.962.5OXSB70EGRESSG137" X 72 38"460.080.046.950.8OXNO SB70EGRESSH MULL2-1" X 4" X 18" X 75"4/563.963.946.962.5CLIPPED, EXTRUDED ALUMINUM TUBE MULLION -L.M.I20-1118.13MULLVERTICALDR 11A172" X 96"580.080.046.962.5SERIES "EL300" ALUMINUM OUTSWING ENTRANCEDOOR - L.M.I22551.1XXDOBLE LEAFSB70DR 2172" X 81 12"480.080.046.950.8XXDOBLE LEAFNO SB70FROSTEDSGD 31A167 58" X 91"560.060.046.950.8SERIES "EL400" ALUMINUM SLIDING GLASS DOOR -L.M.I20-1118.06XXNO SB70GENERAL NOTES:1.G.C. TO VERIFY ALL M.O. DIMENSIONS2.FOR GENERAL NOTES REFER TO SHEET SD-0.03.WIND LOADS WERE DESIGNED IN ACCORDANCE WITH THE FBC2020/ ASCE 7-16, AND HAVE BEEN REDUCED TO SERVICE LOADS.WINDOW & DOORSCHEDULEDRAWNDRAWING TITLEDATECHECKED BYSHEETREV BYDATE DESCRIPTION05.10.2021SD-2.06/2/2021 10:00 AMs:\sde's\2021\residential\04.26.2021 - jp calderon\dwg\juan pablo calderon residence.dwg
4851 N.W. 36th AVE.MIAMI, FL 33142O: 305.269.3999F: 305.260.5114WWW.READYWINDOWS.COMPROJECT NAME:
LOCATION:
JUAN PABLO CALDERON RESIDENCE
4100 N. HIGHWAY A1A.
HUTCHINSON ISLAND, FL 34949SCALEPROJECT No:21-174-NO-JUAN PABLOCALDERONRESIDENCEDHNOSHOP DRAWING CHECKED FOR STRUCTURALREQUIREMENTS ONLY.WIMAL SUARIS, P.E.DLG ENGINEERINGFLA. P.E. # 37369CA #28476N.T.S.