Loading...
HomeMy WebLinkAboutAPPROVED PA-02 FL22250.1 ES-EL100 SH5/25/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquYPIHVa8bqMVi1pAYax0qm2pkqQ5LL2oUZ4sfz1TixOw%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL22250-R4 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer E.S. Windows, Inc. Address/Phone/Email 10653 NE Quaybridge Ct. Miami, FL 33138 (305) 624-7775 achamorro@eswllc.com Authorized Signature Jalal Farooq veronica@afceng.com Technical Representative Manuel Perez Address/Phone/Email 10653 NE Quaybridge Ct. Miami, FL 33138 maph@bellsouth.net Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Jalal Farooq Florida License PE-81223 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/16/2025 Validated By JAVAD AHMAD PE, INC. Validation Checklist - Hardcopy Received Certificate of Independence FL22250_R4_COI_SS - Certificate of Independence.pdf Referenced Standard and Year (of Standard)Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Sections from the Code 5/25/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquYPIHVa8bqMVi1pAYax0qm2pkqQ5LL2oUZ4sfz1TixOw%3d%3d 2/2 Product Approval Method Method 1 Option D Date Submitted 12/21/2020 Date Validated 12/21/2020 Date Pending FBC Approval 12/30/2020 Date Approved 02/09/2021 Summary of Products FL #Model, Number or Name Description 22250.1 Series ES-EL100 Aluminum Single Hung Window Large missile impact resistant aluminum single hung window. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-80 Other: See attached drawing W17-39 for installation instructions. Installation Instructions FL22250_R4_II_SS - ES-EL100 SH (LMI) DWG W17-39 (2020 R1).pdf Verified By: Jalal Farooq PE # 81223 Created by Independent Third Party: Yes Evaluation Reports FL22250_R4_AE_SS - ES-EL100 SH (LMI)- PAE (2020-R1).pdf Created by Independent Third Party: Yes 22250.2 Series ES-EL100 Aluminum Single Hung Window Non-Impact resistant aluminum single hung window. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +80/-80 Other: See attached drawing 20-62F for installation instructions. Installation Instructions FL22250_R4_II_SS - ES-EL100 SH (NI) DWG 20-62F (2020).pdf Verified By: Jalal Farooq PE #81223 Created by Independent Third Party: Yes Evaluation Reports FL22250_R4_AE_SS - ES-EL100 SH (NI)- PAE 2020.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 9360 Sunset Drive Ste 220 | Miami, FL 33173 | T: 305.264.8100 | F: 305.262.6978 | www.afceng.com | alfarooq@afceng.com PRODUCT APPROVAL EVALUATION RULE CHAPTER #61G20-3 • METHOD 1 OPTION D FL 22250 Date: 12/21/2020 Detailed Product Description: Manufacturer: E.S. WINDOWS, LLC. Manufacturer Address: 3550 N.W. 49 STREET – MIAMI, FL. 33142 Model Name: SERIES ES-EL100 ALUMINUM SINGLE HUNG WINDOW Maximum Load: +80 PSF, -80 PSF (Large Missile Impact) Installation Drawings # W17-39 This product complies with the High Velocity Hurricane Zone (HVHZ) testing requirements. For maximum sizes, combination of span vs loads and anchor type refer to installation drawings. Comparative analysis used _ Yes X No Mandatory Tests (Tested in accordance with AAMA 101/I.S.2/NAFS/TAS-202) TEST DESCRIPTION TEST LOCATION TEST REPORT DATE TEST REPORT # TEST SEALED BY ASTM E283 Air Infiltration Leakage Blackwater Testing Inc. Architectural Testing Inc. Fenestration Testing Lab. 03/31/2017 04/23/2020 BT-ESW-17-018 F9504.01-450-18 FTL-11027 Constantin Bortes, PE Justin McDonald, PE Idalmis Ortega, PE ASTM E331 OR ASTM 547 & TAS 202 Water Penetration Blackwater Testing Inc. Architectural Testing Inc. Fenestration Testing Lab. 03/31/2017 04/23/2020 BT-ESW-17-018 F9504.01-450-18 FTL-11027 Constantin Bortes, PE Justin McDonald, PE Idalmis Ortega, PE ASTM E330 & TAS 202 Uniform Static Air Press. Blackwater Testing Inc. Architectural Testing Inc. Fenestration Testing Lab. 03/31/2017 04/23/2020 12/18/2020 BT-ESW-17-018 F9504.01-450-18 FTL-11027 FTL-12413 Constantin Bortes, PE Justin McDonald, PE Idalmis Ortega, PE Idalmis Ortega, PE ASTM F588 Forced Entry Blackwater Testing Inc. Architectural Testing Inc. 03/31/2017 BT-ESW-17-018 F9504.01-450-18 Constantin Bortes, PE Justin McDonald, PE 1235 SW 87th Avenue | Miami, FL 33174 | T: 305.264.8100 | F: 305.262.6978 | www.afceng.com | alfarooq@afceng.com Supplemental Tests (Tested in accordance with TAS-201 and TAS-203) TEST DESCRIPTION TEST LOCATION TEST REPORT DATE TEST REPORT # TEST SEALED BY FBC 1626.2 (TAS 201 & 203) Large Missile Impact & Cyclic Blackwater Testing Inc. Architectural Testing Inc. Fenestration Testing Lab. 03/31/2017 04/23/2020 12/18/2020 BT-ESW-17-018 F9504.01-450-18 FTL-11027 FTL-12413 Constantin Bortes, PE Justin McDonald, PE Idalmis Ortega, PE Idalmis Ortega, PE Under the limitations of the attached installation drawings, to the best of my knowledge and ability, the above product conforms to the requirements of the 2020 Florida Building Code. Evaluation Report Engineer: Jalal Farooq PE # 81223 Al-Farooq Corporation EB # 3538 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20 Sealed: 12/21/20