Loading...
HomeMy WebLinkAboutAPPROVED A6.10 SchedulesProject: C D00K SCHEDULE w coLULU z 0 POOR 51ZE POOR FRAME o w � = .. � <� � L w M z_ U- v w < o � < = Q :2o LU m z o M 0 w 0) Q ll- LU Q Q w Q - z_ U_ DETAIL5 (5EE KEMAKK5)Lu � m o z Q ~ o w _ WIDTH X HEIGHT THICKNESS FIRST FLOOR 100A 14'-0" X 14'-0" - D 5T - F - - - - - - - - - 08 STEEL ROLL-UF D00R 100A 1005 3'-0" X 7-0" 1 5/4" A HM - F A HM F 51 J1 - H1 ADA - 02 1005 100C 30'-0" X 20'-0" - F 5T - F - - - - - - - - - 08 STEEL ROLL-UF D00R 100C loop 3'-0" X 7-0" 1 3/4" A HM - F A HM F 51 J1 - H1 ADA - 02 loop 100E N 0 T U 5 E D 100E - - - - - - - - - - 10OF 14'-0" X 14'-0" - D 5T - F - - - - - - - - - 08 STEEL ROLL-UF D00R 10OF 10OG 3'-0" X 7-0" 1 5/4" A HM - F A HM F 51 J1 - H1 ADA - 02 10OG 100H 14'-0" X 14'-0" - D 5T - F - - - - - - - - - 08 STEEL ROLL-UF D00R 100H 1001 14'-0" X 14'-0" - D 5T - F - - - - - - - - - 08 STEEL ROLL-UF D00R 1001 100J 3'-0" X 7-0" 1 3/4" A HM - F A HM F 51 J1 - H1 ADA - 02 10oJ 100K 10'-0" X 10'-0" - E 5T - F - - - - - - - - - 08 STEEL ROLL-UF D00R 100K 100L 30'-0" X 20'-0" - F 5T - F - - - - - - - - - 08 STEEL ROLL-UF D00R 100L 100M 3'-0" X 7-0" 1 5/4" A HM - F A HM F 51 J1 - H1 ADA - 02 lo0M 10ON 14%0" X 14'-0" - D 5T - F - - - - - - - - - 08 STEEL ROLL-UF D00R 10ON 101A 3'-0" X 7-0" 1 3/4" A HM - F 13 HM F 51 J2 - H2 ADA - 02 101A 10113 3'-0" X 7-0" 1 5/4" C HM RG F 13 HM F 52 J2 - H2 - 90 MIN 06 10113 101C 3'-0" X 7-0" 1 5/4" C HM RG F 13 HM F 52 J2 - H2 - 90 MIN 06 101C 102 3'-0" X 7-0" 1 3/4" A HM - F 13 HM F 52 J2 - H2 - - 05 102 103 3'-0" X 7-0" 1 5/4" A HM - F 13 HM F 52 J2 - H2 - - 05 103 104 3'-0" X 7-0" 1 3/4" A HM - F 13 HM F 52 J2 - H2 - - 07 104 105 3'-0" X 7-0" 1 5/4" A HM - F 13 HM F 52 J2 - H2 - - 07 105 106 3'-0" X 7-0" 1 3/4" 13 HM - F 13 HM F 52 J2 - H2 - - 04 106 107 (2) 3'-0" X 7-0" 1 3/4" A HM - F C HM F 52 J2 - H2 - - 03 107 108 3'-0" X 7-0" 1 5/4" C HM TF F 13 HM F 52 J2 - H2 - - 04 108 109 (2) 3'-0" X 7-0" 1 5/4" 13 HM - F C HM F 51 J2 - H2 ADA - 01 109 LVR = FULLY LOUVERED HCW = HOLLOW CORE WOOD WD = WOOD GYP = GYPSUM I30ARD AN = ANODIZED KG = RATED GLA55 K = KYNAR (FIRELITE PLUS) GS = GALVANIZED STEEL 5CW = SOLID CORE WOOD MTL = METAL MRB = MOISTURE RE51TANT GYF. FL = PLASTIC LAMINATE- F = FACTORY FIN15H FG = FIDERGLA55 WD = WOOD TF = TEMPERED IG = GREY TINTED, IMPACT I3V = BIRCH VENEER F = FAINT RESISTANT GLA55 0 3'-0" DOOR TYPE 'A' 0 iml �I • • DOOR TYPE 'C' DOOR TYf E 'D' 02/1-1 D00K pIZOFILES I [111011110# DOOR TYf E 'E' 5CALE: 1/4" = 1'-0" jL ROOM FINISH SCHEDULE FLOCK 13A5E WALL CEILING NORTH EAST 5OUTH WE5T Q < Q Q < < Q z w w w = w = w = w = w = � = d z o Q < Q Q < < Q w z z z z z w o ROOM NAME / LOCATION :2 :2 :2 U U U U- :2 U_ _ 100 SHOP CONC - - F/P - F - - - - EXP F 29'+/- 100 101 BREAK ROOM C5 - CMU P CMU P CMU P CMU P DW P VARIES 101 102 OFFICE C5 - CMU IF CMU IF CMU IF CMU IF EXP F VARIES 102 103 OFFICE C5 - CMU P CMU IF CMU IF CMU IF EXP F VARIES 103 104 MEN C5 - CMU EF CMU EF CMU EF CMU EF EXF F VARIES 104 105 WOMEN C5 - CMU EF CMU EF CMU EF CMU EF EXP F VARIES 105 106 JANITOR C5 - CMU EF CMU EF CMU EF CMU EF EXP F VARIES 106 107 STORAGE C5 - CMU P CMU P CMU P CMU P EXP F VARIES 107 108 CLEAN ROOM C5 - CMU EF CMU EF CMU EF CMU EF EXP F VARIES 108 109 ELEC./AIR COMPRESSOR C5 - CMU IF CMU IF CMU IF CMU P EXP F VARIES 109 110 COVERED AREA C5 - - - - - - - - - EXP F 29'+/- 110 FLOOR 13A5E WALL CEILING WD -WOOD (LAMINATE) LF -LINOLEUM FLOORING WS -5-1/2" WOOD 5A5E GYP -GYPSUM 5OAR0 P-1 -LATEX PAINT ACT -24 X 24 ACCOU5TICAL TILE CPT -CARPET EF -EPDXY FLOORING CTS -CERAMIC TILE BASE MR5 -MOISTURE RESISTANT BOARD SASE COLOR GYP -GYPSUM BOARD CT -CERAMIC TILE C5 -CONCRETE SEALER EX -EXISTING BASE EF -EPDXY PAINT 12-2 -LATEX PAINT EX -EXISTING DRYWALL VCT -VINYL CUT TILE ECC -EPDXY COATED CONCRETE PTS -PORCELIN TILE BASE F -FACTORY FINISH ACCENT COLOR EXP -EXPOSED STRUCTURE PT -PORCELAIN TILE EX -EXISTING VS 46" VINYL BASE CMU -GONG. MAS. UNIT (STRUCK BLOCK FINISH) F -FACTORY FINISH KF -RUBBER FLOORING CONC -CONCRETE E5 -6" EPDXY SASE P -LATEX PAINT 5C -SKY CEILING 5Y "SKY FACTORY" MS -METAL SLDG. P -LATEX PAINT 5TC -STUCCO DOOR HAKDWAKE 5 C H E D U L E HARDWARE GROUP NO. 01 - EXTERIOR PAIR - LOUVERED HARDWARE GROUP NO. 04 - INTERIOR - CLEAN RM/JANITOR 109 106 108 Provide each PR door(s) with the following: Provide each SGL door(s) with the following: QTY DESCRIPTION CATALOG NUMBER FINISH MFR QTY DESCRIPTION CATALOG NUMBER FINISH MFR 6 EA HINGE 513131 4.5 X 4.5 NRP 630 IVE 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 2 EA SURFACE BOLT SB360 12" T 604 IVE 1 EA STOREROOM LOCK T581 P6 DAN 626 FAL 1 EA STOREROOM LOCK T581 P6 DAN 23981152 626 FAL 1 EA SURFACE CLOSER SC81 REG OR PA AS REQ 689 FAL 2 EA SURFACE CLOSER SC71 HDPA 689 FAL 1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE 1 EA RAIN DRIP 142AA AA ZER 1 EA WALL STOP WS406/407CVX 630 IVE 1 EA CONTACT SEAL PS-074 AS REQUIRED PER NOA STE 3 EA SILENCER SR64 GRY IVE 2 EA DOOR BOTTOM FAS-SEAL STE 1 EA THRESHOLD 566A-223 A ZER FBC NOA FL10356.2 BASIS OF DESIGN HARDWARE GROUP NO. 05 - INTERIOR - OFFICE 102 103 Provide each SGL door(s) with the following: HARDWARE GROUP NO. 02 - EXTERIOR SHOP - SINGLE QTY DESCRIPTION CATALOG NUMBER FINISH MFR 101A 100B 10OG 100J 100M 100D 3 EA HINGE 5BB14.5X4.5 652 IVE Provide each SGL door(s) with the following: 1 EA ENTRY LOCK T501 P6 DANE 626 FAL QTY DESCRIPTION CATALOG NUMBER FINISH MFR 1 EA SURFACE CLOSER SC81 REG OR PA AS REQ 689 FAL 3 EA HINGE 5BB1 4.5 X 4.5 NRP 630 IVE 1 EA WALL STOP WS406/407CVX 630 IVE 1 EA STOREROOM LOCK T581 P6 DAN 23981152 626 FAL 3 EA SILENCER SR64 GRY IVE 01 1 EA SURFACE CLOSER SC71 HDPA 689 FAL 10 1 EA RAIN DRIP 11A A ZER 1 EA GASKETING 139A-S A ZER HARDWARE GROUP NO. 06 - INTERIOR - BREAKROOM - RATED 1 EA RAIN DRIP 142AA AA ZER 101B 101C H3 1 EA GASKETING 188SBK PSA BK ZER Provide each SGL door(s) with the following: 1 EA DOOR SWEEP 328AA AA ZER QTY DESCRIPTION CATALOG NUMBER FINISH MFR A6.11 1 EA GASKETING 475AA-S AA ZER 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA DOOR BOTTOM FAS-SEAL STE 1 EA PASSAGE SET T101S DANE 626 FAL _ 1 EA THRESHOLD 566A-223 A ZER 1 EA SURFACE CLOSER SC81 REG OR PA AS REQ 689 FAL O FBC NOA FL10356.5 BASIS OF DESIGN 1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE N 1 EA WALL STOP WS406/407CVX 630 IVE 3 EA GASKETING 488SBK PSA BK ZER HARDWARE GROUP NO. 03 - INTERIOR PAIR - STORAGE 53 107 Provide each PR door(s) with the following: HARDWARE GROUP NO. 07 - INTERIOR - RESTROOM d A6.11 QTY DESCRIPTION CATALOG NUMBER FINISH MFR 104 105 6 EA HINGE 513131 4.5 X 4.5 652 IVE Provide each SGL door(s) with the following: 2 EA MANUAL FLUSH BOLT FB458 626 IVE QTY DESCRIPTION CATALOG NUMBER FINISH MFR 1 EA DUST PROOF STRIKE DP2 626 IVE 3 EA HINGE 5BB1 4.5 X 4.5 652 IVE 1 EA STOREROOM LOCK T581 P6 DAN 626 FAL 1 EA PUSH PLATE 8200 4" X 16" 630 IVE 2 EA SURFACE CLOSER SC81 REG OR PA AS REQ 689 FAL 1 EA PULL PLATE 8303 10" 4" X 16" 630 IVE 2 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE 1 EA SURFACE CLOSER SC81 REG OR PA AS REQ 689 FAL 2 EA SILENCER SR64 GRY IVE 1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE ASTRAGAL BY DOOR SUPPLIER 1 EA WALL STOP WS406/407CVX 630 IVE 3 EA SILENCER SR64 GRY IVE WINDOW TYPE 'A' FIXED ALUMINUM HARDWARE GROUP NO. 08 - EXTERIOR OVERHEAD DOOR 100A 100C 100E 10OF 100H 1001 STOREFRONT - LMI 100K 100L 10ON Provide each RU door(s) with the following: QTY DESCRIPTION CATALOG NUMBER FINISH MFR ALL HARDWARE BY DOOR SUPPLIER 01 WINDOW F 1z0 F I L E 30'-0" DOOR TYf E 'F' DOOR FRAME DOOR FRAME TYf E 'A' TYPE 'B' 03 DOOR FKAME f ROFILES FKOp05ED BUILDING FOR D&D WELDING 5500 SOUTH STEEL P LVD. FT. FIEKCE, FLORIDA Key Flan: 155ue5: No.: Date: Description: A. 04/14/20 CLIENT REVIEW B. 02/1 /21 ERMIT T C. 06/29/21 OWNER REV1510N5 A rc h itect: DONADIO & Associates, Architects P.A. 2001 9th Avenue, Suite 308 Vero Beach, FL 32960 Tol.772.794.2929 Fax.772.562.8600 License No. AA0002238 www.donadio-arc,h.com 5CALE: 1/4" =1'-0" GonSultant: Drawing Title: SCHEDULES Drrn: Dwg. File: �►*f• MT n g Y DI it +�• �' Chd: XREF File: :. y * + • AJD by Antimony J.�t� roject No.: Plot File: DOOR FRAME J Don • =. �• 2019-54 TYFE ,�, • Date:. •' ,29 Sheet No.: Donadio 08:541 A6.10 Date Signed: 5CALE: 1/4" =1'-0" Copyright © 2020, Donadio & Associates, Architects, P.A.