HomeMy WebLinkAboutAPPROVED, PROJ-37436 - Somers Residence SealedREVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEG-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951 9.86kW PV SYSTEMCODES AND STANDARDS5621 SPANISH RIVER RD,FORT PIERCE, FL 34951SOMERS RESIDENCEVICINITY MAPSHEET INDEXG-01COVER SHEETPROJECT SITEPROJECT DESCRIPTION:OWNERHOUSE PHOTOEQUIPMENT SUMMARY27 LG NEON: LG365N1C-A6 (365W) MODULES27ENPHASE IQ7PLUS-72-2-US MICROINVERTERS27x365 LG NEON: LG365N1C-A6 (365W) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESGOVERNING CODES :FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 EDITION (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)NATIONAL ELECTRICAL CODE 2017 (NEC)ASCE 7-16A-01ROOF PLANS-01MODULE LAYOUTSHEET SHEET DESCRTOCOVER SHEETA-00NOTES AND DESCRIPTIONI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020,CHAPTER 3. BUILDING STRUCTURE WILL SAFELYACCOMMODATE WIND LATERAL AND UPLIFTFORCES, AND EQUIPMENT DEAD LOADS.ELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION:I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107.DESIGN FACTORS:WIND SPEED (ULT): 160WIND SPEED (ASD): 124RISK CATEGORY:IIEXPOSURE:CPROJECT SITESS-01.1ARTAL RESSURE AD MODULES EXOSURESUNPRO SOLAR4492-4494 EAGLE FALLS PLACETAMPA, FL 33619PH:(813) 285-5439INSTALLERCastillo Engineering Services LLC620 N. Wymore Road, Suite 250,Maitland, FL 32751TEL: (407) 289-2575Ermocrates E. CastilloLicense#: FL PE 52590ENGINEERSOMERS, STEPHENRACKING: UNIRAC LIGHT RAILATTACHMENT: UNIRAC FLASHKIT TILE REPLACEMENTS-02ATTACHMET DETALS-02.1STRUCTURE CALCULATOE-01ELECTRCAL LE DAGRAME-02WRG CALCULATOSE-03SYSTEM LABELGDS-01-06DATA SHEETSSYSTEM SIZE:9.86 kW DC STCARRAY AREA #1:234.04 SQ FT.ARRAY AREA #2:253.55 SQ FT.ARRAY AREA #3:39.01 SQ FT.
System DescriptionThis system is a grid-tied, PV system, with PV generation consisting of 27 LGNEON: LG365N1C-A6 (365W) MODULES with a combined STC rated dc outputpower of 9855 W. The modules are connected into 27 ENPHASE IQ7PLUS-72-2-USMICROINVERTERS. The inverter has electronic maximum power point tracking tomaximize energy captured by the PV modules. The inverter also has an internalground fault detection and interruption device that is set to disconnect the array inthe event that a ground fault that exceeds one ampere should occur. The inverterhas DC and AC disconnect integrated system and labels are provided as required bythe National Electrical CodeWhen the sun is shining, power from the PV array is fed into the inverter,where it is converted from DC to AC. The inverter output is then used to contributeto the power requirements of the occupancy. If PV power meets the requirementsof the loads of the occupancy, any remaining PV power is sold back to the utility.When utility power is available, but PV power is not available, building loads aresupplied by the utility.The inverter meets the requirements of IEEE 1547 and UL 1741.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxFigure 1: PV System Block DiagramSection..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........AC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBACDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberVent, Attic fan(Roof obstruction)PV Roof AttachmentTrussesConduitFire AccessAC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCB Combiner BoxDC Direct CurrentACD AC DisconnectDISC Disconnect(E) ExistingEL ElevationEQ EqualJB Junction BoxMCB Main Combiner BoxMFR ManufacturerMIN MinimumMISC Miscellaneous(N) NewOCPD OverCurrent Protection DevicePOCC Point Of Common CouplingPV PhotovoltaicSF Squarefoot/feetSTC Standard Test ConditionsTBD To Be DeterminedTYP TypicalUnless Noted Otherwise VIF Verify In FieldWP Weather ProofTesla PowerwallBATUtility meterUMGPGeneration PanelMDPMain Distribution PanelSoladeckSDNVAD North American Vertical datumUN0MID Microgrid Interconnect DeviceREVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-00CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951NOTES ANDDESCRIPTIONSymbols:Abbreviations:LG NEON:LG365N1C-A6(365W) MODULES68.5"41"RAILS IN THISPOSITION UNOFALL PROTECTION:ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENTMUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT ORSUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDSPER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:·AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICHMAINTAINS A SAFETY FACTOR OF AT LEAST TWO.·UNDER THE SUPERVISION OF A QUALIFIED PERSONADDITIONAL INFORMATION·29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.·1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES···1926.502(D)(15)ALLOWABLE DESIGN PRESSUREPSFDOWN PRESSURE125UPLIFT PRESSURE, 2 RAILS88
UMCBACDMDPSDSDSD30'-0"5'-0"
4'-8"21'-0"114'-0"51'-0"114'-0"51'-0"REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951ROOF PLANROOF PLAN WITH FIRE SETBACKSAND PROPERTY LINESA-01SCALE: 3/32" = 1'-0"11" IMC, RMC, FMC, LFMC, PVC,HDPE, NUCC, RTRC, LFNC, FMT,ENT OR EMT CONDUIT RUN(N) SOLADECK (TYP.)(N) (27) ENPHASE IQ7PLUS-72-2-USMICROINVERTERSSPANISH RIVER RD1-STORYHOUSEROOF #2(13) LG NEON: LG365N1C-A6 (365W)MODULES(E) UTILITY METER(E) MAIN DISTRIBUTION PANEL(N) AC DISCONNECT(N) ENPHASE IQ COMBINER BOXROOF #1(12) LG NEON: LG365N1C-A6 (365W) MODULESEXISTINGDRIVEWAYROOF #3(02) LG NEON: LG365N1C-A6(365W) MODULES
60'-1"4'-0"(TYP.)4'-0"(TYP.)43'-6"REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951MODULE LAYOUTMODULE LAYOUTS-01SCALE: 3/32" = 1'-0"1MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES =27 MODULESMODULE TYPE = LG NEON: LG365N1C-A6 (365W) MODULESWEIGHT = 41.01LBS / 18.6 KG.MODULE DIMENSIONS = 68.5" x 41" = 19.50 SFUNIT WEIGHT OF ARRAY = 2.10 PSFLEGEND- NON- EXPOSED MODULE- MIN. MODULE EDGE DISTANCE LINE- EDGE MODULE- MODULE EXPOSURE LINE- EXPOSED MODULE- WIND ZONE 1 (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 3e (TYP)- MISSING MODULEGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED ASSHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS.2) EXISTING RESIDENTIAL BUILDING IS A W-TILE ROOF WITH MEANROOF HEIGHT IS 15 FT AND SYP 2"X4" ROOF TRUSSES SPACED 24" O.C.EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS 22.6DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TOTHE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS ANDIN FIELD CONDITIONS.* I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3. BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFT WINDLOADS AND EQUIPMENT DEAD LOADS. *WINDZONESNON-EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 14' - 0"1' - 4"4' - 0"1' - 4"ZONE 1'XXXXZONE 2e4' - 0"1' - 4"2' - 0"0' - 8"ZONE 2nXXXXZONE 2r4' - 0"1' - 4"2' - 0"0' - 8"ZONE 3e4' - 0"1' - 4"2' - 0"0' - 8"ZONE 3rXXXXROOFROOF TYPEARRAYAREA(Sq. Ft.) ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZETRUSSSPACING#1W-TILE234.04475.6449.2122.6°270°2"X4"24" O.C.#2W-TILE253.55660.1838.4122.6°180°2"X4"24" O.C.#3W-TILE39.01781.154.9922.6°0°2"X4"24" O.C.(76) PV ROOF ATTACHMENT @ 24" & 48" O.C. MAX.(SEE SHEET S-02 FOR ATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIAL PRESSURE OFTHE MODULE)(N) UNIRAC LIGHT RAIL (TYP.)(E) FRONT YARD
(E) BACK YARDROOF #1TILT - 22.6°AZIM. - 270°ROOF #2TILT - 22.6°AZIM. - 180°(N) (27) ENPHASE IQ7PLUS-72-2-USMICROINVERTERSROOF #2(13) LG NEON: LG365N1C-A6 (365W)MODULESROOF #1(12) LG NEON: LG365N1C-A6 (365W) MODULESROOF #3(02) LG NEON: LG365N1C-A6(365W) MODULESROOF #3TILT - 22.6°AZIM. - 0°
8'-1"13'-4"7'-7"7'-3"7'-10"7'-9"P1P16P17P2P3P18P4P5P6P19P7P8P9P10P11P12P13P20P14P15REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951ARTAL RESSURE ADMODULES EXOSUREPARTIAL PRESSURE AND MODULES EXPOSURES-01.1SCALE: 3/32" = 1'-0"1NOTE : PARTIAL PRESSURES OF THE WIND ZONES ONALL MODULES HAVE BEEN VERIFIED AND ARE WITHINTHE ALLOWABLE PER THE MANUFACTURERSPECIFICATION, INSTALLER SHOULD FOLLOW THELAYOUT TO AVOID HIGHER ZONAL PARTIALPRESSURES. ANY CHANGES IN LAYOUT SHOULD BEREPORTED BACK TO THE ENGINEER OF RECORD.2h2DISTANCE : 10"0.5hDISTANCE : 7' - 6"2h20.5hLEGEND- NON- EXPOSED MODULE- MIN. MODULE EDGE DISTANCE LINE- EDGE MODULE- MODULE EXPOSURE LINE- EXPOSED MODULE- WIND ZONE 1 (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 3e (TYP)- MISSING MODULENON-EXPOSED MODULES:(E) FRONT YARD
(E) BACK YARD
ROOF #2(13) LG NEON: LG365N1C-A6 (365W)MODULESROOF #1(12) LG NEON: LG365N1C-A6(365W) MODULESROOF #3(02) LG NEON: LG365N1C-A6(365W) MODULESEXPOSED MODULES:ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS: 88 PSFALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS: 88 PSF
5''REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951ATTACHMET DETAL2S-02SCALE: NTSATTACHMENT DETAIL(ENLARGED SECTION VIEW)L-FOOT(E) ROOF SHEATHINGFLASHKIT TILEREPLACEMENTSOLAR MODULEMODULE MID/END CLAMPUNIRAC LIGHT RAIL (TYP.)2 STAINLESS STEEL LAG BOLTSL-FOOT(E)W-TILE ROOFFLASHKIT TILE REPLACEMENT(E) ROOF SHEATHINGATTACHMENT DETAILSCALE - 1'' = 1'-0''S-021EPDM WASHERTIERED RISERMODULE MID/END CLAMP(E) 2"X4" TRUSSES @ 24" O.C.h25/16"DIA. X 3"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMING(E) 2"X4" TRUSSES @ 24" O.C.(4"X4") TRUSS SPANNER ORBLOCKING FOR MISSED TRUSSATTACHMENT (IF REQUIRED)MAINTAIN 3/4" DISTANCE FROMTHE EDGE PER NDS 2018MAINTAIN 3/4" DISTANCE FROMTHE EDGE PER NDS 2018UNIRAC LIGHT RAIL (TYP.)TILE REPLACEMENT
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951STRUCTURECALCULATO
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951ELECTRCALLE DAGRAMSOLAR ARRAY (9.86 KW-DC STC) TOTAL(27) LG NEON: LG365N1C-A6 (365W) MODULES(03) STRINGS OF 09 MODULESL2L1NL2L1GN20A/2PG10A (N) 125A ENPHASE IQ COMBINER 3(X-IQ-AM1-240-3) [WITH UPTO (4)2-POLE BREAKERS AND ENVOYCOMMUNICATION GATEWAY]1ELECTRICAL LINE DIAGRAME-01SCALE: NTS(N) SOLADECK600 V, NEMA 3RUL LISTEDQ CABLES(3) 12/2 ROMEX RUN IN ATTICOR(3) #12 AWG THWN-2 - RED(3) #12 AWG THWN-2 - BLACK(1) #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT, OR EMTCONDUIT RUNGGGG(N) JUNCTION BOX600 V, NEMA 3UL LISTEDGGL1L2L1L2GGGGPV MODULESENPHASE IQ7PLUS-72-2-USMICROINVERTERS(3) #12 AWG THWN-2(3) #12 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNGGL2L120A/2PL1L2L1L2GGGGGGGGGGGGGGGGGGL2L120A/2PL1L2L1L2(3) #6 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUN(E) MAIN DISTRIBUTIONPANEL, 200A RATED, 240VEXISTING GROUNDINGELECTRODE SYSTEMBI-DIRECTIONALUTILITY METER1-PHASE, 240VTO UTILITY GRIDL2L1L2L1GL2L1L2L1L2L1L2L1L1L2NL1L2N(N) MAIN BREAKER175A/2P, 240VNINTERCONNECTION120% RULE - NEC 705.12(B)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED175A + 60A = 235ABUSS RATING x 120%200A x 120% = 240ALOAD TAP USING INSULATIONPIERCING PER NEC 705.12(B)L2L1L2L1NNGG(N) AC DISCONNECT:240V, 60AMPNEMA 3R, UL LISTED WITH 60A FUSESLOCKABLE AND FUSIBLENOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TOMEET THE REQUIREMENTS OF THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATION, INCLUDING MAXIMUMNUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULEMANUFACTURER AND MODEL NUMBER, INVERTERMANUFACTURER AND MODEL NUMBER, AS APPLICABLE2. PROVIDE TAP BOX IN COMPLIANCE WITH NEC 312.8 IFPANEL GUTTER SPACE IS INADEQUATE.3. IF THE FUSED AC DISCONNECT WIRE RUN EXCEEDS10 FT FROM THE POINT OF INTERCONNECTION, CABLELIMITERS OR CURRENT-LIMITED CIRCUIT BREAKERSMUST BE INSTALLED FOR EACH UNGROUNDEDCONDUCTOR PER NEC 705.31.4. ALL PANELS DOWNSTREAM OF LOAD TAP TO BEPROTECTED BY A SUITABLE OCPD PER NEC 408.36.5. LOAD CALCULATIONS PRIOR TO MAIN BREAKERRE-RATE TO BE PROVIDED BY INSTALLER ORELECTRICAL CONTRACTOR.
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951WRG CALCULATOSAC CONDUCTOR AMPACITY CALCULATIONS:FROM ROOF TOP SOLADECK TO LOAD CENTERAC CONDUCTOR AMPACITY CALCULATIONS:FROM AC COMBINER BOX TO MSPELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR75 DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).ENPHASE IQ7PLUS-72-2-US MICROINVERTERInput Data (DC)Output Data (AC)Recommended Input Power (STC)Maximum Input DC VoltagePeak Power Tracking VoltageOperating RangeMin. / Max. Start VoltageMax DC Short Circuit CurrentMaximum Output PowerNominal Output CurrentNominal Voltage / RangeNominal Frequency / RangeExtended Frequency / RangePower Factor at rated powerMaximum unit per 20A Branch Circuit245-400W +60V27V-45V16V-60V22V / 60V15A290W1.21A240V/211-264V60 Hz47-68 Hz1.013 (240 VAC)
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951SYSTEM LABELGPHOTOVOLTAIC SYSTEMWITH RAPIDSHUTDOWN SWITCHLABEL LOCATION:AC DISCONNECT(PER CODE: NEC690.56(C)(3))LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED.· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 32.6 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!NOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC690.52)DATA PER PANELTURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSAC DISCONNECT9.86 KW SOLARDISCONNECT LOCATEDPHOTOVOLTAICSYSTEM MICROINVERTERSLOCATED UNDER EACHPV MODULE INROOF TOP ARRAYAC COMBINER BOXLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)SOLAR CONNECTIONLINE SIDE TAP SOLARBREAKERLABEL LOCATION:COMBINER BOX(PER CODE: NEC690.52)LABEL LOCATION:INVERTER(PER CODE: NEC690.52)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)LABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(A))LABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-04CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-05CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951DATA SHEET
REVSHEET NAMESHEET SIZESHEET NUMBERSOMERS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-06CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC5621 SPANISH RIVER RD,
FORT PIERCE, FL 34951DATA SHEET