HomeMy WebLinkAboutDESIGN PRESSURE FOR WALLPi hi
(c) 2v1!--huctures b1terneriwial, LL,
Design Data
Wind Velocity (mph)
Risk Category
Exposure Category
Directionalitv Factor
Internal Pressure Caeffcient +t_
Company: Hurricane Guard
Prepared By: Neil Anderson
Client Name: Edwards
Job Description: 4 accordions
Project Number:
4WIND WALL
DESIGN PRESSURES FOR WALL COMPONENTS & CLADDING
Building Data
164
Mean Roof Height
2
Building VV[dth (ft)
D
Building Length (ft)
0.86
Roof Slope (x:12)
0.18
Design pressures listed below are:
mfoms t.ith AS•=E 7-1v
25
61
42
6
Allowable Stress
OPENING
MARK
OPENING
DESCRIPTION
LOCATION
ZONE
OPENING
ELEVATION
OPENING DIMENSIONS
NDTH INCHES HEIGHT INCHES
61AXIh1UM POSITIVE
PRRSSURE PSF
MAXIMUM NEGATIVE
PRESSURE PSF
1
2
3
Accordion
Accordion
Accordion
4
5
5
5
15
15
77.625
285.75
495.75
104.375
92.75
93.75
41.4
37.7
34.8
-45.4
-44.b
-39.7
4
Accordion
5
i5
70
93,75
42.1
-53.3
Width of End Zone (a) in feet = 4.2
STRUCTURES INTERNATIONAL. LLC
6/28/2021 1;08 PM
OTCHazards by Location
Search Information
Address:
10751 S Ocean Dr, Jensen Beach, FL 34957,
USA
Coordinates:
27.269913,-80.2076809
Elevation:
4 ft
Timestamp:
2021-06-21 T19:31:19.565Z
Hazard Type: Wind
ASCE 7-16
MRI 10-Year 88 mph
MR125-Year 109 mph
MRI50-Year 122 mph
MRI 100-Year A 133 mph
You are in a wind-borne debris region if
you are also within 1 mile of the coastal
mean high water line.
Risk Category 1 150 mph
Risk Category 11 A 164 mph
You are in a wind-borne debris region.
Risk Category III A 175 mph
If the structure under consideration is a
healthcare facility and you are also within
1 mile of the coastal mean high water
line, you are in a wind-borne debris
region. If other occupancy, use the Risk
Category 11 basic wind speed contours to
determine if you are in a wind-borne
debris region.
Risk Category IV A 186 mph
You are in a wind-borne debris region.
ASCE 7-10
T Grill & P'.Zzu
HOW 4 ft tit St Lucie
9 Vistana Bee
AIA
6"
l 0
e% f_ _ � RMap data emi
MRI 10-Year 89 mph
MRI25-Year 109 mph
MR150-Year 122 mph
MRI 100-Year A 133 mph
You are in a wind-borne debris region
if you are also within 1 mile of the
coastal mean high water line.
Risk Category 1 150 mph
Risk Category II A 164 mph
You are in a wind-borne debris
region.
Risk Category III -IV A 175 mph
If the structure under consideration is
a healthcare facility and you are also
within 1 mile of the coastal mean high
water line, you are in a wind-borne
debris region. If other occupancy, use
the Risk Category II basic wind speed
contours to determine if you are in a
wind-borne debris region.
ASCE 7-06
ASCE 7-05 Wind Speed A 143 mph
You are in a wind-borne debris region
The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the
building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction
before proceeding with design.