Loading...
HomeMy WebLinkAboutDESIGN PRESSURE FOR WALLPi hi (c) 2v1!--huctures b1terneriwial, LL, Design Data Wind Velocity (mph) Risk Category Exposure Category Directionalitv Factor Internal Pressure Caeffcient +t_ Company: Hurricane Guard Prepared By: Neil Anderson Client Name: Edwards Job Description: 4 accordions Project Number: 4WIND WALL DESIGN PRESSURES FOR WALL COMPONENTS & CLADDING Building Data 164 Mean Roof Height 2 Building VV[dth (ft) D Building Length (ft) 0.86 Roof Slope (x:12) 0.18 Design pressures listed below are: mfoms t.ith AS•=E 7-1v 25 61 42 6 Allowable Stress OPENING MARK OPENING DESCRIPTION LOCATION ZONE OPENING ELEVATION OPENING DIMENSIONS NDTH INCHES HEIGHT INCHES 61AXIh1UM POSITIVE PRRSSURE PSF MAXIMUM NEGATIVE PRESSURE PSF 1 2 3 Accordion Accordion Accordion 4 5 5 5 15 15 77.625 285.75 495.75 104.375 92.75 93.75 41.4 37.7 34.8 -45.4 -44.b -39.7 4 Accordion 5 i5 70 93,75 42.1 -53.3 Width of End Zone (a) in feet = 4.2 STRUCTURES INTERNATIONAL. LLC 6/28/2021 1;08 PM OTCHazards by Location Search Information Address: 10751 S Ocean Dr, Jensen Beach, FL 34957, USA Coordinates: 27.269913,-80.2076809 Elevation: 4 ft Timestamp: 2021-06-21 T19:31:19.565Z Hazard Type: Wind ASCE 7-16 MRI 10-Year 88 mph MR125-Year 109 mph MRI50-Year 122 mph MRI 100-Year A 133 mph You are in a wind-borne debris region if you are also within 1 mile of the coastal mean high water line. Risk Category 1 150 mph Risk Category 11 A 164 mph You are in a wind-borne debris region. Risk Category III A 175 mph If the structure under consideration is a healthcare facility and you are also within 1 mile of the coastal mean high water line, you are in a wind-borne debris region. If other occupancy, use the Risk Category 11 basic wind speed contours to determine if you are in a wind-borne debris region. Risk Category IV A 186 mph You are in a wind-borne debris region. ASCE 7-10 T Grill & P'.Zzu HOW 4 ft tit St Lucie 9 Vistana Bee AIA 6" l 0 e% f_ _ � RMap data emi MRI 10-Year 89 mph MRI25-Year 109 mph MR150-Year 122 mph MRI 100-Year A 133 mph You are in a wind-borne debris region if you are also within 1 mile of the coastal mean high water line. Risk Category 1 150 mph Risk Category II A 164 mph You are in a wind-borne debris region. Risk Category III -IV A 175 mph If the structure under consideration is a healthcare facility and you are also within 1 mile of the coastal mean high water line, you are in a wind-borne debris region. If other occupancy, use the Risk Category II basic wind speed contours to determine if you are in a wind-borne debris region. ASCE 7-06 ASCE 7-05 Wind Speed A 143 mph You are in a wind-borne debris region The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design.